3 resultados para Object control

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

30.00% 30.00%

Publicador:

Resumo:

When a hand-held object is moved, grip and load force are accurately coordinated for establishing grasp stability. In the present work, the question was raised whether patients with Gilles de la Tourette syndrome (TS), who show tic-like movements, are impaired in grip-load force control when executing a manipulative task. To this end, we assessed force regulation during action patterns that required rhythmical unimanual or bimanual (iso-directional/anti-directional) movements. Results showed that the profile of grip-load force ratio was characterized by maxima and minima that were realized at upward and downward hand positions, respectively. TS patients showed increased force ratios during unimanual and bimanual movements, compared with control subjects, indicative of an inaccurate specification of the precision grip. Functional imaging data complemented the behavioural results and revealed that secondary motor areas showed no (or greatly reduced) activation in TS patients when executing the movement tasks as compared with baseline conditions. This indicates that the metabolic level in the secondary motor areas was equal during rest and task performance. At the neuronal level, this observation suggests that these cortical areas were continuously involved in movement preparation. Based on these data, we conclude that the ongoing activation of secondary motor areas may be explained by the TS patients' involuntary urges to move. Accordingly, interference will prevent an accurate planning of voluntary behaviour. Together, these findings reveal modulations in movement organization in patients with TS and exemplify degrading consequences for manual function.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECT: Ultrasound may be a reliable but simpler alternative to intraoperative MR imaging (iMR imaging) for tumor resection control. However, its reliability in the detection of tumor remnants has not been definitely proven. The aim of the study was to compare high-field iMR imaging (1.5 T) and high-resolution 2D ultrasound in terms of tumor resection control. METHODS: A prospective comparative study of 26 consecutive patients was performed. The following parameters were compared: the existence of tumor remnants after presumed radical removal and the quality of the images. Tumor remnants were categorized as: detectable with both imaging modalities or visible only with 1 modality. RESULTS: Tumor remnants were detected in 21 cases (80.8%) with iMR imaging. All large remnants were demonstrated with both modalities, and their image quality was good. Two-dimensional ultrasound was not as effective in detecting remnants<1 cm. Two remnants detected with iMR imaging were missed by ultrasound. In 2 cases suspicious signals visible only on ultrasound images were misinterpreted as remnants but turned out to be a blood clot and peritumoral parenchyma. The average time for acquisition of an ultrasound image was 2 minutes, whereas that for an iMR image was approximately 10 minutes. Neither modality resulted in any procedure-related complications or morbidity. CONCLUSIONS: Intraoperative MR imaging is more precise in detecting small tumor remnants than 2D ultrasound. Nevertheless, the latter may be used as a less expensive and less time-consuming alternative that provides almost real-time feedback information. Its accuracy is highest in case of more confined, deeply located remnants. In cases of more superficially located remnants, its role is more limited.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A large body of research analyzes the runtime execution of a system to extract abstract behavioral views. Those approaches primarily analyze control flow by tracing method execution events or they analyze object graphs of heap snapshots. However, they do not capture how objects are passed through the system at runtime. We refer to the exchange of objects as the object flow, and we claim that object flow is necessary to analyze if we are to understand the runtime of an object-oriented application. We propose and detail Object Flow Analysis, a novel dynamic analysis technique that takes this new information into account. To evaluate its usefulness, we present a visual approach that allows a developer to study classes and components in terms of how they exchange objects at runtime. We illustrate our approach on three case studies.