239 resultados para OCCLUSION
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
The coronary collateral circulation has a beneficial role regarding all-cause and cardiac mortality. Hitherto, the underlying mechanism has not been clarified. The aim of this prospective study was to assess the effect of the coronary collateral circulation on electrocardiogram (ECG) QTc time change during short-term myocardial ischaemia.
Resumo:
Mechanical thrombectomy in ischemic stroke is of increasing interest as it is a promising strategy for fast and efficient recanalization. Several thrombectomy devices have been introduced to the armentarium of mechanical thrombectomy. Currently, new devices are under development and are continuously added to the neurointerventional tool box. Each device advocated so far has a different design and mechanical properties in terms of thrombus-device interaction. Therefore, a systematic evaluation under standardized conditions in vivo of these new devices is needed. The purpose of this study was to evaluate the efficiency, thrombus-device interaction, and potential complications of the novel Phenox CRC for distal mechanical thrombectomy in vivo. The device was evaluated in an established animal model in the swine. Recanalization rate, thromboembolic events, vasospasm, and complications were assessed. Radiopaque thrombi (2 cm length) were used for the visualization of thrombus-device interaction during retrieval. The Phenox CRC (4 mm diameter) was assessed in 15 vessel occlusions. For every occlusion a maximum of 3 retrieval attempts were performed. Complete recanalization (TICI 3/TIMI 3) was achieved in 86.7% of vessel occlusions. In 66.7% (10/15), the first retrieval attempt was successful, and in 20% (3/15), the second attempt led to complete recanalization of the parent artery. In 2 cases (13.3%) thrombus retrieval was not successful (TICI 0/TIMI 0). In 1 case (6.7%) a minor embolic event occurred in a small side branch. No distal thromboembolic event was observed during the study. Thrombus-device interaction illustrated the entrapment of the thrombus by the microfilaments and the proximal cage of the device. No significant thrombus compression was observed. No vessel perforation, dissection, or fracture of the device occurred. In this small animal study, the Phenox CRC was a safe and effective device for mechanical thrombectomy. The unique design with a combination of microfilaments and proximal cage reduces thrombus compression with a consequently high recanalization and low complication rate.
Resumo:
In ischemic stroke, the site of arterial obstruction has been shown to influence recanalization and clinical outcomes. However, this has not been studied in randomized controlled trials, nor has the impact of arterial obstruction site on reperfusion and infarct growth been assessed. We studied the influence of site and degree of arterial obstruction patients enrolled in the Echoplanar Imaging Thrombolytic Evaluation Trial (EPITHET).
Resumo:
Intravenous thrombolysis (IVT) for stroke seems to be beneficial independent of the underlying etiology. Recent observations raised concern that IVT might cause harm in patients with strokes attributable to small artery occlusion (SAO).
Resumo:
Delayed occlusion time in parent artery occlusion of brain-supplying vessels might carry risk for thromboembolic complications. Vascular plug devices are successfully used in cardiopulmonary and peripheral interventions to occlude high-flow lesions and have been adapted for use in neurointerventions. The purpose of the present study was to experimentally evaluate the immediate occlusion time of the AMPLATZER vascular plug (AVP) II-a second-generation cylindrical, self-expandable, resheathable nitinol wire mesh consisting of three lobes-in the carotid artery.
Resumo:
Randomized trials suggested a different benefit of intravenous thrombolysis (IVT) and intra-arterial thrombolysis (IAT) between men and women with anterior circulation stroke because of a worse outcome of women in the control group.
Resumo:
Diagnostic coronary balloon occlusion (CBO) is mandatory for collateral function assessment, during angioscopy and optical coherence imaging, and when using certain coronary protection devices against emboli. Thus far, the safety of diagnostic CBO regarding procedural and long-term complications in normal coronary arteries has not been studied. In 316 patients, diagnostic CBO was performed for collateral function measurement in 426 angiographically normal vessels. The angioplasty balloon was inflated for 60 to 120 seconds using inflation pressures of 1 to 3 atm, followed by control angiography during and after CBO. Patients were divided into groups with entirely normal (n = 133) and partially normal (n = 183) vessels. Primary end points were procedural and long-term complications. De novo stenosis development was assessed by quantitative coronary angiography in 35% of the patients. Secondary end points were cardiac events at 5 years of follow-up. Procedural complications occurred in 1 patient (0.2%). In 150 repeat angiographic procedures in 92 patients (follow-up duration 10 +/- 15 months), quantitative coronary angiography revealed no difference in percentage diameter narrowing between baseline and follow-up (4.1% vs 3.9%, p = 0.69). During follow-up periods of 14 and 72 months, respectively, a new stenotic lesion was detected in 1 patient in each group (1.3%). Major cardiac events and percutaneous coronary intervention for stable angina were less frequent in the group with entirely normal than with partially normal vessels (0.8% vs 5.5%, p = 0.02, and 0.8% vs 18%, p <0.0001). In conclusion, low-inflation pressure diagnostic CBO in angiographically normal coronary arteries bears a minimal risk for procedural and long-term complications and can therefore be regarded as a safe procedure.
Resumo:
Many people with acute myocardial infarction die from sudden cardiac arrest before reaching the hospital. The current clinical understanding of the mechanisms and risk factors surrounding sudden cardiac death is limited. However, 2 factors related to sudden death, namely the occluded coronary vessel (right coronary, left circumflex, or left anterior descending artery) and the extent of collateral circulation, are of potential relevance. Recent data suggest that the risk differs between the different coronary arteries and that coronary collateral circulation seems to have an important protective 'antiarrhythmic' effect. This editorial will address possible mechanisms and potential implications in clinical practice.
Resumo:
The European PLAATO (Percutaneous Left Atrial Appendage Transcatheter Occlusion) study was performed to determine the safety and efficacy of left atrial appendage occlusion by catheter technique. Embolic stroke due to atrial fibrillation is a common observation, especially in the elderly. Most thrombi in atrial fibrillation form in the left atrial appendage (LAA), its occlusion may therefore reduce the incidence of stroke in these patients.
Resumo:
Intra-arterial thrombolysis can be used for treatment of basilar artery occlusion. Predictors of outcome before initiation of treatment are of special interest.
Resumo:
The use of self-expanding retrievable stents is an emerging and promising treatment strategy for acute stroke treatment. The concept combines the advantages of stent deployment with immediate flow-restoration and of mechanical thrombectomy with definitive thrombus removal. The present study was performed to gain more knowledge about the principle of combined flow restoration and thrombectomy in an established animal model using radiopaque thrombi evaluating efficiency, thrombus-device interaction and possible complications of the first dedicated flow-restoration and mechanical thrombectomy device.
Resumo:
To date, there is limited data on intra-arterial thrombolysis (IAT) and intravenous thrombolysis (IVT) for isolated posterior cerebral artery (PCA) occlusion. We aimed to evaluate recanalization, outcome and quality of life in patients who undergo thrombolysis for isolated PCA occlusion.
Resumo:
The purpose of this study was to analyze predictive factors for best-corrected visual acuity (BCVA) after anti-VEGF treatment in patients with macular edema (ME) secondary to central retinal vein occlusion (CRVO).