27 resultados para Non-magnetic Nanosized Spinel Oxides

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Many metabolites in the proton magnetic resonance spectrum undergo magnetization exchange with water, such as those in the downfield region (6.0-8.5 ppm) and the upfield peaks of creatine, which can be measured to reveal additional information about the molecular environment. In addition, these resonances are attenuated by conventional water suppression techniques complicating detection and quantification. To characterize these metabolites in human skeletal muscle in vivo at 3 T, metabolite cycled non-water-suppressed spectroscopy was used to conduct a water inversion transfer experiment in both the soleus and tibialis anterior muscles. Resulting median exchange-independent T(1) times for the creatine methylene resonances were 1.26 and 1.15 s, and for the methyl resonances were 1.57 and 1.74 s, for soleus and tibialis anterior muscles, respectively. Magnetization transfer rates from water to the creatine methylene resonances were 0.56 and 0.28 s(-1) , and for the methyl resonances were 0.39 and 0.30 s(-1) , with the soleus exhibiting faster transfer rates for both resonances, allowing speculation about possible influences of either muscle fibre orientation or muscle composition on the magnetization transfer process. These water magnetization transfer rates observed without water suppression are in good agreement with earlier reports that used either postexcitation water suppression in rats, or short CHESS sequences in human brain and skeletal muscle.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study is to develop a new simple method for analyzing one-dimensional transcranial magnetic stimulation (TMS) mapping studies in humans. Motor evoked potentials (MEP) were recorded from the abductor pollicis brevis (APB) muscle during stimulation at nine different positions on the scalp along a line passing through the APB hot spot and the vertex. Non-linear curve fitting according to the Levenberg-Marquardt algorithm was performed on the averaged amplitude values obtained at all points to find the best-fitting symmetrical and asymmetrical peak functions. Several peak functions could be fitted to the experimental data. Across all subjects, a symmetric, bell-shaped curve, the complementary error function (erfc) gave the best results. This function is characterized by three parameters giving its amplitude, position, and width. None of the mathematical functions tested with less or more than three parameters fitted better. The amplitude and position parameters of the erfc were highly correlated with the amplitude at the hot spot and with the location of the center of gravity of the TMS curve. In conclusion, non-linear curve fitting is an accurate method for the mathematical characterization of one-dimensional TMS curves. This is the first method that provides information on amplitude, position and width simultaneously.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Evaluation of a novel non-invasive tool for postoperative follow-up of patients postelective saphenous vein coronary artery bypass graft (CABG) was performed. Ten patients were included. Their bypass grafts supplied the right coronary artery (7), marginal branches (1), diagonal branches (2), and the circumflex artery (n=1). Each bypass was examined intraoperatively using Doppler flow measurement. Patients were examined with a 3-Tesla magnetic resonance imaging (MRI) scanner (MAGNETOM Verio, Siemens, Erlangen, Germany) within one week postsurgery using MR-angiography with an intravasal contrast agent and velocity encoded phase-contrast flow measurements. Intraoperative Doppler flow measurements revealed regular flow patterns in all vascular territories supplied. The median intraoperative flow rate was 50 ml/min with an inter-quartile range (IQR) of 42-70 ml/min. The clinical postoperative course was uneventful. MRI showed all grafts to be patent. The median postoperative flow rate was 50 ml/min (IQR: 32-65 ml/min). MRI flow rates agreed well with intraoperative Doppler flow measurements (mean difference: -2.8±20.1 ml/min). This initial study demonstrates that 3-Tesla MRI flow measurements correlated well with Doppler thus reconfirming the graft patency postCABG. Further refinement and broader application of this technique may facilitate follow-up postCABG potentially replacing empiric clinical judgment by reliable non-invasive imaging.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Magnetic resonance spectroscopy enables insight into the chemical composition of spinal cord tissue. However, spinal cord magnetic resonance spectroscopy has rarely been applied in clinical work due to technical challenges, including strong susceptibility changes in the region and the small cord diameter, which distort the lineshape and limit the attainable signal to noise ratio. Hence, extensive signal averaging is required, which increases the likelihood of static magnetic field changes caused by subject motion (respiration, swallowing), cord motion, and scanner-induced frequency drift. To avoid incoherent signal averaging, it would be ideal to perform frequency alignment of individual free induction decays before averaging. Unfortunately, this is not possible due to the low signal to noise ratio of the metabolite peaks. In this article, frequency alignment of individual free induction decays is demonstrated to improve spectral quality by using the high signal to noise ratio water peak from non-water-suppressed proton magnetic resonance spectroscopy via the metabolite cycling technique. Electrocardiography (ECG)-triggered point resolved spectroscopy (PRESS) localization was used for data acquisition with metabolite cycling or water suppression for comparison. A significant improvement in the signal to noise ratio and decrease of the Cramér Rao lower bounds of all metabolites is attained by using metabolite cycling together with frequency alignment, as compared to water-suppressed spectra, in 13 healthy volunteers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Novel magnetic resonance imaging sequences have and still continue to play an increasing role in neuroimaging and neuroscience. Among these techniques, diffusion-weighted imaging (DWI) has revolutionized the diagnosis and management of diseases such as stroke, neoplastic disease and inflammation. However, the effects of aging on diffusion are yet to be determined. To establish reference values for future experimental mouse studies we tested the hypothesis that absolute apparent diffusion coefficients (ADC) of the normal brain change with age. A total of 41 healthy mice were examined by T2-weighted imaging and DWI. For each animal ADC frequency histograms (i) of the whole brain were calculated on a voxel-by-voxel basis and region-of-interest (ROI) measurements (ii) performed and related to the animals' age. The mean entire brain ADC of mice <3 months was 0.715(+/-0.016) x 10(-3) mm2/s, no significant difference to mice aged 4 to 5 months (0.736(+/-0.040) x 10(-3) mm2/s) or animals older than 9 months 0.736(+/-0.020) x 10(-3) mm2/s. Mean whole brain ADCs showed a trend towards lower values with aging but both methods (i + ii) did not reveal a significant correlation with age. ROI measurements in predefined areas: 0.723(+/-0.057) x 10(-3) mm2/s in the parietal lobe, 0.659(+/-0.037) x 10(-3) mm2/s in the striatum and 0.679(+/-0.056) x 10(-3) mm2/s in the temporal lobe. With advancing age, we observed minimal diffusion changes in the whole mouse brain as well as in three ROIs by determination of ADCs. According to our data ADCs remain nearly constant during the aging process of the brain with a small but statistically non-significant trend towards a decreased diffusion in older animals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Transcranial magnetic stimulation has evolved into a powerful neuroscientific tool allowing to interfere transiently with specific brain functions. In addition, repetitive TMS (rTMS) has long-term effects (e.g. on mood), probably mediated by neurochemical alterations. While long-term safety of rTMS with regard to cognitive functioning is well established from trials exploring its therapeutic efficacy, little is known on whether rTMS can induce changes in cognitive functioning in a time window ranging from minutes to hours, a time in which neurochemical effects correlated with stimulation have been demonstrated. This study examined effects of rTMS on three measures of executive function in healthy subjects who received one single rTMS session (40 trains of 2 s duration 20 Hz stimuli) at the left dorsolateral prefrontal cortex (DLPFC). Compared to a sham condition one week apart, divided attention performance was significantly impaired about 30-60 min after rTMS, while Stroop-interference and performance in the Wisconsin Card Sorting Test was unaffected after rTMS. Repetitive TMS of the left DLPFC, at stimulation parameters used in therapeutic studies, does not lead to a clinically relevant impairment of executive function after stimulation. However, the significant effect on divided attention suggests that cognitive effects of rTMS are not limited to the of acute stimulation, and may possibly reflect known neurochemical alterations induced by rTMS. Sensitive cognitive measures may be useful to trace those short-term effects of rTMS non-invasively in humans.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: To analyse the results of recent studies not yet included in a 2003 report of the International Commission on Non-Ionizing Radiation Protection (ICNIRP) on occupational exposure to low-frequency electromagnetic fields as potential risk factor for neurodegenerative diseases. METHODS: A literature search was conducted in the online databases of PubMed, ISI Web of Knowledge, DIMDI and COCHRANE, as well as in specialised databases and journals. Eight studies published between January 2000 and July 2005 were included in the review. RESULTS: The findings of these studies contribute to the evidence of an association between occupational magnetic field exposure and the risk of dementia. Regarding amyotrophic lateral sclerosis, the recent results confirm earlier observations of an association with electric and electronic work and welding. Its relationship with magnetic field exposure remains unsolved. There are only few findings pointing towards an association between magnetic field exposure and Parkinson's disease. CONCLUSIONS: The epidemiological evidence for an association between occupational exposure to low-frequency electromagnetic fields and the risk of dementia has increased during the last five years. The impact of potential confounders should be evaluated in further studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Triggered event-related functional magnetic resonance imaging requires sparse intervals of temporally resolved functional data acquisitions, whose initiation corresponds to the occurrence of an event, typically an epileptic spike in the electroencephalographic trace. However, conventional fMRI time series are greatly affected by non-steady-state magnetization effects, which obscure initial blood oxygen level-dependent (BOLD) signals. Here, conventional echo-planar imaging and a post-processing solution based on principal component analysis were employed to remove the dominant eigenimages of the time series, to filter out the global signal changes induced by magnetization decay and to recover BOLD signals starting with the first functional volume. This approach was compared with a physical solution using radiofrequency preparation, which nullifies magnetization effects. As an application of the method, the detectability of the initial transient BOLD response in the auditory cortex, which is elicited by the onset of acoustic scanner noise, was used to demonstrate that post-processing-based removal of magnetization effects allows to detect brain activity patterns identical with those obtained using the radiofrequency preparation. Using the auditory responses as an ideal experimental model of triggered brain activity, our results suggest that reducing the initial magnetization effects by removing a few principal components from fMRI data may be potentially useful in the analysis of triggered event-related echo-planar time series. The implications of this study are discussed with special caution to remaining technical limitations and the additional neurophysiological issues of the triggered acquisition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIMS: To investigate the relationship between extremely low frequency magnetic field (ELF-MF) exposure and mortality from leukaemia and brain tumour in a cohort of Swiss railway workers. METHODS: 20,141 Swiss railway employees with 464,129 person-years of follow-up between 1972 and 2002 were studied. Mortality rates for leukaemia and brain tumour of highly exposed train drivers (21 muT average annual exposure) were compared with medium and low exposed occupational groups (i.e. station masters with an average exposure of 1 muT). In addition, individual cumulative exposure was calculated from on-site measurements and modelling of past exposures. RESULTS: The hazard ratio (HR) for leukaemia mortality of train drivers was 1.43 (95% CI 0.74 to 2.77) compared with station masters. For myeloid leukaemia the HR of train drivers was 4.74 (95% CI 1.04 to 21.60) and for Hodgkin's disease 3.29 (95% CI 0.69 to 15.63). Lymphoid leukaemia, non-Hodgkin's disease and brain tumour mortality were not associated with magnetic field exposure. Concordant results were obtained from analyses based on individual cumulative exposure. CONCLUSIONS: Some evidence of an exposure-response association was found for myeloid leukaemia and Hodgkin's disease, but not for other haematopoietic and lymphatic malignancies and brain tumours.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Proton magnetic resonance spectroscopy (MRS) allows the assessment of various cerebral metabolites non-invasively in vivo. Among 1H MRS-detectable metabolites, N-acetyl-aspartate and N-acetyl-aspartyl-glutamate (tNAA), trimethylamines (TMA), creatine and creatine phosphate (tCr), inositol (Ins) and glutamate (Gla) are of particular interest, since these moieties can be assigned to specific neuronal and glial metabolic pathways, membrane constituents, and energy metabolism. In this study on 94 subjects from a memory clinic population, 1H MRS results (single voxel STEAM: TE 20 ms, TR 1500 ms) on the above metabolites were assessed for five different brain regions in probable vascular dementia (VD), probable Alzheimer's disease (AD), and age-matched healthy controls. In both VD and AD, ratios of tNAA/tCr were decreased, which may be attributed to neuronal atrophy and loss, and Ins/tCr-ratios were increased indicating either enhanced gliosis or alteration of the cerebral inositol metabolism. However, the topographical distribution of the metabolic alterations in both diseases differed, revealing a temporoparietal pattern for AD and a global, subcortically pronounced pattern for VD. Furthermore, patients suffering from vascular dementia (VD) had remarkably enhanced TMA/tCr ratios, potentially due to ongoing degradation of myelin. Thus, the metabolic alterations obtained by 1H MRS in vivo allow insights into the pathophysiology of the different dementias and may be useful for diagnostic classification.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Because of superior soft-tissue contrast compared to other imaging techniques, non-invasive abdominal magnetic resonance imaging (MRI) is ideal for monitoring organ regeneration, tissue repair, cancer stage, and treatment effects in a wide variety of experimental animal models. Currently, sophisticated MR protocols, including technically demanding procedures for motion artefact compensation, achieve an MRI resolution limit of < 100 microm under ideal conditions. However, such a high spatial resolution is not required for most experimental rodent studies. This article describes both a detailed imaging protocol for MR data acquisition in a ubiquitously and commercially available 1.5 T MR unit and 3-dimensional volumetry of organs, tissue components, or tumors. Future developments in MR technology will allow in vivo investigation of physiological and pathological processes at the cellular and even the molecular levels. Experimental MRI is crucial for non-invasive monitoring of a broad range of biological processes and will further our general understanding of physiology and disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Theta burst transcranial magnetic stimulation (TBS) may induce behavioural changes that outlast the stimulation period. The neurophysiological basis of these behavioural changes are currently under investigation. Given the evidence that cortical information processing relies on transient synchronization and desynchronization of neuronal assemblies, we set out to test whether TBS is associated with changes of neuronal synchronization as assessed by surface EEG. In four healthy subjects one TBS train of 600 pulses (200 bursts, each burst consisting of 3 pulses at 30 Hz, repeated at intervals of 100 ms) was applied over the right frontal eye field and EEG synchronization was assessed in a time-resolved manner over 60 min by using a non-overlapping moving window. For each time step the linear cross-correlation matrix for six EEG channels of the right and for the six homotopic EEG channels of the left hemisphere were computed and their largest eigenvalues used to assess changes of synchronization. Synchronization was computed for broadband EEG and for the delta, theta, alpha, beta and gamma frequency bands. In all subjects EEG synchronization of the stimulated hemisphere was significantly and persistently increased relative to EEG synchronization of the unstimulated hemisphere. This effect occurred immediately after TBS for the theta, alpha, beta and gamma frequency bands and 10-20 min after TBS for broadband and delta frequency band EEG. Our results demonstrate that TBS is associated with increased neuronal synchronization of the cerebral hemisphere ipsilateral to the stimulation site relative to the unstimulated hemisphere. We speculate that enhanced synchronization interferes with cortical information processing and thus may be a neurophysiological correlate of the impaired behavioural performance detected previously.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: Ultra-high-field whole-body systems (7.0 T) have a high potential for future human in vivo magnetic resonance imaging (MRI). In musculoskeletal MRI, biochemical imaging of articular cartilage may benefit, in particular. Delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) and T2 mapping have shown potential at 3.0 T. Although dGEMRIC, allows the determination of the glycosaminoglycan content of articular cartilage, T2 mapping is a promising tool for the evaluation of water and collagen content. In addition, the evaluation of zonal variation, based on tissue anisotropy, provides an indicator of the nature of cartilage ie, hyaline or hyaline-like articular cartilage.Thus, the aim of our study was to show the feasibility of in vivo dGEMRIC, and T2 and T2* relaxation measurements, at 7.0 T MRI; and to evaluate the potential of T2 and T2* measurements in an initial patient study after matrix-associated autologous chondrocyte transplantation (MACT) in the knee. MATERIALS AND METHODS: MRI was performed on a whole-body 7.0 T MR scanner using a dedicated circular polarization knee coil. The protocol consisted of an inversion recovery sequence for dGEMRIC, a multiecho spin-echo sequence for standard T2 mapping, a gradient-echo sequence for T2* mapping and a morphologic PD SPACE sequence. Twelve healthy volunteers (mean age, 26.7 +/- 3.4 years) and 4 patients (mean age, 38.0 +/- 14.0 years) were enrolled 29.5 +/- 15.1 months after MACT. For dGEMRIC, 5 healthy volunteers (mean age, 32.4 +/- 11.2 years) were included. T1 maps were calculated using a nonlinear, 2-parameter, least squares fit analysis. Using a region-of-interest analysis, mean cartilage relaxation rate was determined as T1 (0) for precontrast measurements and T1 (Gd) for postcontrast gadopentate dimeglumine [Gd-DTPA(2-)] measurements. T2 and T2* maps were obtained using a pixelwise, monoexponential, non-negative least squares fit analysis; region-of-interest analysis was carried out for deep and superficial cartilage aspects. Statistical evaluation was performed by analyses of variance. RESULTS: Mean T1 (dGEMRIC) values for healthy volunteers showed slightly different results for femoral [T1 (0): 1259 +/- 277 ms; T1 (Gd): 683 +/- 141 ms] compared with tibial cartilage [T1 (0): 1093 +/- 281 ms; T1 (Gd): 769 +/- 150 ms]. Global mean T2 relaxation for healthy volunteers showed comparable results for femoral (T2: 56.3 +/- 15.2 ms; T2*: 19.7 +/- 6.4 ms) and patellar (T2: 54.6 +/- 13.0 ms; T2*: 19.6 +/- 5.2 ms) cartilage, but lower values for tibial cartilage (T2: 43.6 +/- 8.5 ms; T2*: 16.6 +/- 5.6 ms). All healthy cartilage sites showed a significant increase from deep to superficial cartilage (P < 0.001). Within healthy cartilage sites in MACT patients, adequate values could be found for T2 (56.6 +/- 13.2 ms) and T2* (18.6 +/- 5.3 ms), which also showed a significant stratification. Within cartilage repair tissue, global mean values showed no difference, with 55.9 +/- 4.9 ms for T2 and 16.2 +/- 6.3 ms for T2*. However, zonal assessment showed only a slight and not significant increase from deep to superficial cartilage (T2: P = 0.174; T2*: P = 0.150). CONCLUSION: In vivo T1 dGEMRIC assessment in healthy cartilage, and T2 and T2* mapping in healthy and reparative articular cartilage, seems to be possible at 7.0 T MRI. For T2 and T2*, zonal variation of articular cartilage could also be evaluated at 7.0 T. This zonal assessment of deep and superficial cartilage aspects shows promising results for the differentiation of healthy and affected articular cartilage. In future studies, optimized protocol selection, and sophisticated coil technology, together with increased signal at ultra-high-field MRI, may lead to advanced biochemical cartilage imaging.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Clinical magnetic resonance imaging (MRI) is the method of choice for the non-invasive evaluation of articular cartilage defects and the follow-up of cartilage repair procedures. The use of cartilage-sensitive sequences and a high spatial-resolution technique enables the evaluation of cartilage morphology even in the early stages of disease, as well as assessment of cartilage repair. Sequences that offer high contrast between articular cartilage and adjacent structures, such as the fat-suppressed, 3-dimensional, spoiled gradient-echo sequence and the fast spin-echo sequence, are accurate and reliable for evaluating intrachondral lesions and surface defects of articular cartilage. These sequences can also be performed together in reasonable examination times. In addition to morphology, new MRI techniques provide insight into the biochemical composition of articular cartilage and cartilage repair tissue. These techniques enable the diagnosis of early cartilage degeneration and help to monitor the effect and outcome of various surgical and non-surgical cartilage repair therapies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Non-invasive imaging methods are increasingly entering the field of forensic medicine. Facing the intricacies of classical neck dissection techniques, postmortem imaging might provide new diagnostic possibilities which could also improve forensic reconstruction. The aim of this study was to determine the value of postmortem neck imaging in comparison to forensic autopsy regarding the evaluation of the cause of death and the analysis of biomechanical aspects of neck trauma. For this purpose, 5 deceased persons (1 female and 4 male, mean age 49.8 years, range 20-80 years) who had suffered odontoid fractures or atlantoaxial distractions with or without medullary injuries, were studied using multislice computed tomography (MSCT), magnetic resonance imaging (MRI) and subsequent forensic autopsy. Evaluation of the findings was performed by radiologists, forensic pathologists and neuropathologists. The cause of death could be established radiologically in three of the five cases. MRI data were insufficient due to metal artefacts in one case, and in another, ascending medullary edema as the cause of delayed death was only detected by histological analysis. Regarding forensic reconstruction, the imaging methods were superior to autopsy neck exploration in all cases due to the post-processing possibilities of viewing the imaging data. In living patients who suffer medullary injury, follow-up MRI should be considered to exclude ascending medullary edema.