17 resultados para Non-line-of-sight

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Many location-based services target users in indoor environments. Similar to the case of dense urban areas where many obstacles exist, indoor localization techniques suffer from outlying measurements caused by severe multipath propaga??tion and non-line-of-sight (NLOS) reception. Obstructions in the signal path caused by static or mobile objects downgrade localization accuracy. We use robust multipath mitigation techniques to detect and filter out outlying measurements in indoor environments. We validate our approach using a power-based lo??calization system with GSM. We conducted experiments without any prior knowledge of the tracked device's radio settings or the indoor radio environment. We obtained localization errors in the range of 3m even if the sensors had NLOS links to the target device.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study deals with indoor positioning using GSM radio, which has the distinct advantage of wide coverage over other wireless technologies. In particular, we focus on passive localization systems that are able to achieve high localization accuracy without any prior knowledge of the indoor environment or the tracking device radio settings. In order to overcome these challenges, newly proposed localization algorithms based on the exploitation of the received signal strength (RSS) are proposed. We explore the effects of non-line-of-sight communication links, opening and closing of doors, and human mobility on RSS measurements and localization accuracy. We have implemented the proposed algorithms on top of software defined radio systems and carried out detailed empirical indoor experiments. The performance results show that the proposed solutions are accurate with average localization errors between 2.4 and 3.2 meters.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Indoor localization systems become more interesting for researchers because of the attractiveness of business cases in various application fields. A WiFi-based passive localization system can provide user location information to third-party providers of positioning services. However, indoor localization techniques are prone to multipath and Non-Line Of Sight (NLOS) propagation, which lead to significant performance degradation. To overcome these problems, we provide a passive localization system for WiFi targets with several improved algorithms for localization. Through Software Defined Radio (SDR) techniques, we extract Channel Impulse Response (CIR) information at the physical layer. CIR is later adopted to mitigate the multipath fading problem. We propose to use a Nonlinear Regression (NLR) method to relate the filtered power information to propagation distances, which significantly improves the ranging accuracy compared to the commonly used log-distance path loss model. To mitigate the influence of ranging errors, a new trilateration algorithm is designed as well by combining Weighted Centroid and Constrained Weighted Least Square (WC-CWLS) algorithms. Experiment results show that our algorithm is robust against ranging errors and outperforms the linear least square algorithm and weighted centroid algorithm.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Attractive business cases in various application fields contribute to the sustained long-term interest in indoor localization and tracking by the research community. Location tracking is generally treated as a dynamic state estimation problem, consisting of two steps: (i) location estimation through measurement, and (ii) location prediction. For the estimation step, one of the most efficient and low-cost solutions is Received Signal Strength (RSS)-based ranging. However, various challenges - unrealistic propagation model, non-line of sight (NLOS), and multipath propagation - are yet to be addressed. Particle filters are a popular choice for dealing with the inherent non-linearities in both location measurements and motion dynamics. While such filters have been successfully applied to accurate, time-based ranging measurements, dealing with the more error-prone RSS based ranging is still challenging. In this work, we address the above issues with a novel, weighted likelihood, bootstrap particle filter for tracking via RSS-based ranging. Our filter weights the individual likelihoods from different anchor nodes exponentially, according to the ranging estimation. We also employ an improved propagation model for more accurate RSS-based ranging, which we suggested in recent work. We implemented and tested our algorithm in a passive localization system with IEEE 802.15.4 signals, showing that our proposed solution largely outperforms a traditional bootstrap particle filter.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Acute non-specific abdominal pain (NSAP) is prevalent in 6-25% of the general population and is a common cause of admission to the emergency department (ED). Despite involvement of substantial financial and human resources, there are few data on long-term outcome after initial diagnosis. The aim of this study was to evaluate long-term outcome of patients initially admitted with NSAP to an ED.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Not all clinical trials are published, which may distort the evidence that is available in the literature. We studied the publication rate of a cohort of clinical trials and identified factors associated with publication and nonpublication of results. METHODS: We analysed the protocols of randomized clinical trials of drug interventions submitted to the research ethics committee of University Hospital (Inselspital) Bern, Switzerland from 1988 to 1998. We identified full articles published up to 2006 by searching the Cochrane CENTRAL database (issue 02/2006) and by contacting investigators. We analyzed factors associated with the publication of trials using descriptive statistics and logistic regression models. RESULTS: 451 study protocols and 375 corresponding articles were analyzed. 233 protocols resulted in at least one publication, a publication rate of 52%. A total of 366 (81%) trials were commercially funded, 47 (10%) had non-commercial funding. 346 trials (77%) were multi-centre studies and 272 of these (79%) were international collaborations. In the adjusted logistic regression model non-commercial funding (Odds Ratio [OR] 2.42, 95% CI 1.14-5.17), multi-centre status (OR 2.09, 95% CI 1.03-4.24), international collaboration (OR 1.87, 95% CI 0.99-3.55) and a sample size above the median of 236 participants (OR 2.04, 95% CI 1.23-3.39) were associated with full publication. CONCLUSIONS: In this cohort of applications to an ethics committee in Switzerland, only about half of clinical drug trials were published. Large multi-centre trials with non-commercial funding were more likely to be published than other trials, but most trials were funded by industry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Adherence to guidelines is associated with improved outcomes of patients with acute coronary syndrome (ACS). Clinical registries developed to assess quality of care at discharge often do not collect the reasons for non-prescription for proven efficacious preventive medication in Continental Europe. In a prospective cohort of patients hospitalized for an ACS, we aimed at measuring the rate of recommended treatment at discharge, using pre-specified quality indicators recommended in cardiologic guidelines and including systematic collection of reasons for non-prescription for preventive medications. METHODS In a prospective cohort with 1260 patients hospitalized for ACS, we measured the rate of recommended treatment at discharge in 4 academic centers in Switzerland. Performance measures for medication at discharge were pre-specified according to guidelines, systematically collected for all patients and included in a centralized database. RESULTS Six hundred and eighty eight patients(54.6%) were discharged with a main diagnosis of STEMI, 491(39%) of NSTEMI and 81(6.4%) of unstable angina. Mean age was 64 years and 21.3% were women. 94.6% were prescribed angiotensin converting enzyme inhibitors/angiotensin II receptor blockers at discharge when only considering raw prescription rates, but increased to 99.5% when including reasons non-prescription. For statins, rates increased from 98% to 98.6% when including reasons for non-prescription and for beta-blockers, from 82% to 93%. For aspirin, rates further increased from 99.4% to 100% and from to 99.8% to 100% for P2Y12 inhibitors. CONCLUSIONS We found a very high adherence to ACS guidelines for drug prescriptions at discharge when including reasons for non-prescription to drug therapy. For beta-blockers, prescription rates were suboptimal, even after taking into account reason for non-prescription. In an era of improving quality of care to achieve 100% prescription rates at discharge unless contra-indicated, pre-specification of reasons for non-prescription for cardiovascular preventive medication permits to identify remaining gaps in quality of care at discharge.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

During infections, Giardia lamblia undergoes a continuous change of its major surface antigens, the variant-specific surface proteins (VSPs). Many studies on antigenic variation have been performed using G. lamblia clone GS/M-83-H7, which expresses surface antigen VSP H7. The present study was focused on the identification and characterization of vsp gene sequences within the genome of the clonal G. lamblia GS/M-83-H7 line. For this purpose, we applied a PCR which specifically amplified truncated sequences from the 3'-terminal region of the vsp genes. Upon cloning, most of the vsp gene amplification products were shown to be approximately identical in size and thus could not be distinguished from each other by conventional gel electrophoresis. In order to pre-estimate the sequence complexity within the large panel of vsp clones isolated, we elaborated a novel concept which facilitated our large-scale genetic screening approach: PCR products from cloned DNA molecules were generated and then subjected to a DNA melting profile assay based on the use of the LightCycler Instrument. This high-throughput assay system proved to be well suited to monitor sequence differences between the amplification products from closely related vsp genes and thus could be used for the primary, sequence-related discrimination of the corresponding clones. After testing 50 candidates, vsp clones could be divided into five groups, each characterized by an individual DNA melting profile of the corresponding amplification products. Sequence analysis of some of these 50 candidates confirmed data from the aforementioned assay in that clones were demonstrated to be identical within, but different between, the distinct groups. The nucleotide and deduced amino acid sequences of five representative vsp clones showed high similarities both among each other and also with the corresponding gene segment of the variant-specific surface antigen (VSP H7) expressed by the original GS/M-83-H7 variant type. Furthermore, three of the genomic vsp sequences turned out to be identical to vsp sequences that represented previously characterized transcription products from in vivo- or in vitro-switched GS/M-83-H7 trophozoites. In conclusion, the DNA melting profile assay seems to be a versatile tool for the PCR-based genotyping of moderately or highly diversified sequence orthologues.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Concurrent analysis of antibiotic resistance of colonising and invasive Streptococcus pneumoniae gives a more accurate picture than looking at either of them separately. Therefore, we analysed 2,129 non-invasive and 10,996 invasive pneumococcal isolates from Switzerland from 2004 to 2014, which spans the time before and after the introduction of the heptavalent (PCV7) and 13-valent (PCV13) conjugated pneumococcal polysaccharide vaccines. Serotype/serogroup information was linked with all antibiotic resistance profiles. During the study period, the proportion of non-susceptible non-invasive and invasive isolates significantly decreased for penicillin, ceftriaxone, erythromycin and trimethoprim/sulfamethoxazole (TMP-SMX). This was most apparent in non-invasive isolates from study subjects younger than five years (penicillin (p = 0.006), erythromycin (p = 0.01) and TMP-SMX (p = 0.002)). Resistant serotypes/serogroups included in PCV7 and/or PCV13 decreased and were replaced by non-PCV13 serotypes (6C and 15B/C). Serotype/serogroup-specific antibiotic resistance rates were comparable between invasive and non-invasive isolates. Adjusted odds ratios of serotype/serogroup-specific penicillin resistance were significantly higher in the west of Switzerland for serotype 6B (1.8; 95% confidence interval (CI): 1.4-4.8), 9V (3.4; 95% CI: 2.0-5.7), 14 (5.3; 95% CI: 3.8-7.5), 19A (2.2; 95% CI: 1.6-3.1) and 19F (3.1; 95% CI: 2.1-4.6), probably due to variations in the antibiotic consumption.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: The aim of this study is to implement augmented reality in real-time image-guided interstitial brachytherapy to allow an intuitive real-time intraoperative orientation. METHODS AND MATERIALS: The developed system consists of a common video projector, two high-resolution charge coupled device cameras, and an off-the-shelf notebook. The projector was used as a scanning device by projecting coded-light patterns to register the patient and superimpose the operating field with planning data and additional information in arbitrary colors. Subsequent movements of the nonfixed patient were detected by means of stereoscopically tracking passive markers attached to the patient. RESULTS: In a first clinical study, we evaluated the whole process chain from image acquisition to data projection and determined overall accuracy with 10 patients undergoing implantation. The described method enabled the surgeon to visualize planning data on top of any preoperatively segmented and triangulated surface (skin) with direct line of sight during the operation. Furthermore, the tracking system allowed dynamic adjustment of the data to the patient's current position and therefore eliminated the need for rigid fixation. Because of soft-part displacement, we obtained an average deviation of 1.1 mm by moving the patient, whereas changing the projector's position resulted in an average deviation of 0.9 mm. Mean deviation of all needles of an implant was 1.4 mm (range, 0.3-2.7 mm). CONCLUSIONS: The developed low-cost augmented-reality system proved to be accurate and feasible in interstitial brachytherapy. The system meets clinical demands and enables intuitive real-time intraoperative orientation and monitoring of needle implantation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE To evaluate a low-cost, inertial sensor-based surgical navigation solution for periacetabular osteotomy (PAO) surgery without the line-of-sight impediment. METHODS Two commercial inertial measurement units (IMU, Xsens Technologies, The Netherlands), are attached to a patient's pelvis and to the acetabular fragment, respectively. Registration of the patient with a pre-operatively acquired computer model is done by recording the orientation of the patient's anterior pelvic plane (APP) using one IMU. A custom-designed device is used to record the orientation of the APP in the reference coordinate system of the IMU. After registration, the two sensors are mounted to the patient's pelvis and acetabular fragment, respectively. Once the initial position is recorded, the orientation is measured and displayed on a computer screen. A patient-specific computer model generated from a pre-operatively acquired computed tomography scan is used to visualize the updated orientation of the acetabular fragment. RESULTS Experiments with plastic bones (eight hip joints) performed in an operating room comparing a previously developed optical navigation system with our inertial-based navigation system showed no statistically significant difference on the measurement of acetabular component reorientation. In all eight hip joints the mean absolute difference was below four degrees. CONCLUSION Using two commercially available inertial measurement units we show that it is possible to accurately measure the orientation (inclination and anteversion) of the acetabular fragment during PAO surgery and therefore to successfully eliminate the line-of-sight impediment that optical navigation systems have.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: Testosterone (T) is a therapeutic option for women with hypoactive sexual desire disorder. T may have an impact on the mammary gland by altering local estrogen synthesis. The aim of the present study was to measure the effect of T on estrone-sulfate (E1S)-sulfatase (STS) expression, and activity using hormone-dependent BC cells with high and low aggressive potential (BT-474, MCF-7), and HBL-100 as a breast cell line of non-malignant origin. METHODS: Cells were incubated in RPMI 1640 medium containing 5% steroid-depleted fetal calf serum for 3d, and subsequently incubated in absence or presence of T alone, and combined with anastrozole (A) at 10(-8)M, and 10(-6)M at 37 degrees C for either 24h or directly in cell extracts ("direct"). STS protein expression was measured by dot-blot (immunoblotting), and STS, HSD17B1 and HSD17B2 mRNA levels by quantitative RT-PCR. STS activity was evaluated by incubating homogenized breast cells with [(3)H]-E1S and separating the products E1, and E2 by thin layer chromatography. RESULTS: Basal STS mRNA expression did not reveal group differences. However, STS mRNA was decreased by T+A in MCF-7 cells. 17HSDB1 expression was decreased by T+A in BT-474 cells, and 17HSDB2 expression was decreased by A and T+A treatment in MCF-7 cells. Basal and T treated STS protein expression was significantly higher in malignant compared to non-malignant breast cells. However, T did not induce significant intra-cell line differences. Similarly, basal and T treated STS activity was significantly higher in highly malignant compared to non-malignant breast cells. Regardless of cell lines, T slightly decreased STS activity after "direct" incubation, but led to an increase of local estrogen formation after 24h which was attenuated, and partly reversed by A, respectively. CONCLUSIONS: The more aggressive the breast cell line, the higher the local estrogen formation. The transition from normal to malignant seems to be accompanied by an altered autoregulation. The given local endocrine milieu seems to be essential for response to T.