14 resultados para Non-isothermal method
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
The present study validated the accuracy of data from a self-reported questionnaire on smoking behaviour with the use of exhaled carbon monoxide (CO) level measurements in two groups of patients. Group 1 included patients referred to an oral medicine unit, whereas group 2 was recruited from the daily outpatient service. All patients filled in a standardized questionnaire regarding their current and former smoking habits. Additionally, exhaled CO levels were measured using a monitor. A total of 121 patients were included in group 1, and 116 patients were included in group 2. The mean value of exhaled CO was 7.6 ppm in the first group and 9.2 ppm in the second group. The mean CO values did not statistically significantly differ between the two groups. The two exhaled CO level measurements taken for each patient exhibited very good correlation (Spearman's coefficient of 0.9857). Smokers had a mean difference of exhaled CO values of 13.95 ppm (p < 0.001) compared to non-smokers adjusted for the first or second group. The consumption of one additional pack year resulted in an increase in CO values of 0.16 ppm (p = 0.003). The consumption of one additional cigarette per day elevated the CO measurements by 0.88 ppm (p < 0.001). Based on these results, the correlations between the self-reported smoking habits and exhaled CO values are robust and highly reproducible. CO monitors may offer a non-invasive method to objectively assess current smoking behaviour and to monitor tobacco use cessation attempts in the dental setting.
Resumo:
The three-dimensional documentation of footwear and tyre impressions in snow offers an opportunity to capture additional fine detail for the identification as present photographs. For this approach, up to now, different casting methods have been used. Casting of footwear impressions in snow has always been a difficult assignment. This work demonstrates that for the three-dimensional documentation of impressions in snow the non-destructive method of 3D optical surface scanning is suitable. The new method delivers more detailed results of higher accuracy than the conventional casting techniques. The results of this easy to use and mobile 3D optical surface scanner were very satisfactory in different meteorological and snow conditions. The method is also suitable for impressions in soil, sand or other materials. In addition to the side by side comparison, the automatic comparison of the 3D models and the computation of deviations and accuracy of the data simplify the examination and delivers objective and secure results. The results can be visualized efficiently. Data exchange between investigating authorities at a national or an international level can be achieved easily with electronic data carriers.
Resumo:
Aerosols are the most promising non-injectable method of measles vaccination studied so far and their efficacy is thought to be comparable to injected vaccine. We conducted a systematic review up to May 2006 to examine the immunogenicity and safety of aerosolized measles vaccine (Edmonston-Zagreb or Schwarz strains) 1 month or more after vaccination. Where possible we estimated pooled serological response rates and odds ratios (with 95% confidence intervals, CI) comparing aerosolized and subcutaneous vaccines in children in three age groups and adults. We included seven randomized trials, four non-randomized trials and six uncontrolled studies providing serological outcome data on 2887 individuals. In children below 10 months, the studies were heterogeneous. In four comparative studies, seroconversion rates were lower with aerosolized than with subcutaneous vaccine and in two of these the difference was unlikely to be due to chance. In children 10-36 months, the pooled seroconversion rate with aerosolized vaccine was 93.5% (89.4-97.7%) and 97.1% (92.4-100%) with subcutaneous vaccine (odds ratio 0.27, 0.04-1.62). In 5-15-year olds the studies were heterogeneous. In all comparative studies aerosolized vaccine was more immunogenic than subcutaneous. Reported side effects were mild. Aerosolized measles vaccine appears to be equally or more immunogenic than subcutaneous vaccine in children aged 10 months and older. Large randomized trials are needed to establish the efficacy and safety of aerosolized measles vaccine as primary and booster doses.
Resumo:
Annually laminated (varved) sediments of proglacial Lake Silvaplana (46 ̊27’N, 9 ̊48’E, 1791 m a.s.l., Engadine, eastern Swiss Alps) provide an excellent archive for quantitative high-resolution (seasonal – annual) reconstruction of high- and lowfrequency climate signals back to AD 1580. The chronology of the core is based on varve counting, Cs-137, Pb-210 and event stratigraphy. In this study we present a reconstruction based on in-situ reflectance spectroscopy. In situ reflectance spectroscopy is known as a cost- and time-effective non destructtive method for semi-quantitative analysis of pigments (e.g., chlorines and carotenoids) and of lithoclastic sediment fractions. Reflectance-dependent absorption (RDA) was measured with a Gretac Macbeth spectrolino at 2 mm resolution. The spectral coverage ranges from 380 nm to 730 nm at 10 nm band resolution. In proglacial Lake Silvaplana, 99% of the sediment is lithoclastic prior to AD 1950. Therefore, we concentrate on absorption features that are characteristic for lithoclastic sediment fractions. In Lake Silvaplana, two significant correlations that are stable in time were found between RDA typical for lithoclastics and meteorological data: (1) the time series R 570 /R 630 (ratio between RDA at 570 nm and 630 nm) of varves in Lake Silvaplana and May to October temperatures at nearby station of Sils correlate highly significantly (calibration period AD 1864 – 1951, r = 0.74, p < 0.01 for 5ptsmoothed series; RMSE is 0.28 ̊C, RE = 0.41 and CE = 0.38), and (2) the minimum reflectance within the 690nm band (min690) data correlate with May to October (calibration period AD 1864 – 1951, r = 0.68, p < 0.01 for 5pt-smoothed series; RMSE = 0.22 ̊C, RE = 0.5, CE = 0.31). Both proxy series (min690nm and R 570 /R 630 values) are internally highly consistent (r = 0.8, p < 0.001). In proglacial Lake Silvaplana the largest amount of sediment is transported by glacial meltwater. The melting season spans approximately from May to October, which gives us a good understanding of the geophysical processes explaining the correlations between lithoclastic proxies and the meteorological data. The reconstructions were extended back to AD 1580 and show a broad corresponddence with fully independent reconstructions from tree rings and documentary data.
Resumo:
BACKGROUND The diagnostic performance of biochemical scores and artificial neural network models for portal hypertension and cirrhosis is not well established. AIMS To assess diagnostic accuracy of six serum scores, artificial neural networks and liver stiffness measured by transient elastography, for diagnosing cirrhosis, clinically significant portal hypertension and oesophageal varices. METHODS 202 consecutive compensated patients requiring liver biopsy and hepatic venous pressure gradient measurement were included. Several serum tests (alone and combined into scores) and liver stiffness were measured. Artificial neural networks containing or not liver stiffness as input variable were also created. RESULTS The best non-invasive method for diagnosing cirrhosis, portal hypertension and oesophageal varices was liver stiffness (C-statistics=0.93, 0.94, and 0.90, respectively). Among serum tests/scores the best for diagnosing cirrhosis and portal hypertension and oesophageal varices were, respectively, Fibrosis-4, and Lok score. Artificial neural networks including liver stiffness had high diagnostic performance for cirrhosis, portal hypertension and oesophageal varices (accuracy>80%), but were not statistically superior to liver stiffness alone. CONCLUSIONS Liver stiffness was the best non-invasive method to assess the presence of cirrhosis, portal hypertension and oesophageal varices. The use of artificial neural networks integrating different non-invasive tests did not increase the diagnostic accuracy of liver stiffness alone.
Resumo:
Chronic heart transplant rejection, i.e. cardiac allograft vasculopathy (CAV) is a major adverse prognostic factor after heart transplantation (HTx). This study tested the hypothesis that the relative myocardial blood volume (rBV) as quantified by myocardial contrast echocardiography accurately detects severe CAV as defined by coronary intravascular ultrasound (IVUS).
Resumo:
Objectives: To investigate substance loss and bond strength capacity of sclerotic, non-carious cervical dentin after airborne-particle abrasion or diamond bur preparation. Methods: Fifteen non-sclerotic dentin specimens were made from crowns of extracted human incisors of which the labial surfaces had been ground with silicon carbide papers (non-sclerotic control; Group 1). Forty-five sclerotic dentin specimens (n=15/group) were made from the labial, non-carious cervical root part of extracted human incisors and underwent either no pre-treatment (sclerotic control; Group 2), pre-treatment with airborne-particle abrasion (CoJet Prep [3M ESPE] and 50 µm aluminium oxide; Group 3), or with diamond bur preparation (40 µm grit size; Group 4). Substance loss after pre-treatment was measured in Groups 3 and 4. Subsequently, Scotchbond Universal (3M ESPE) and resin composite (CeramX [DENTSPLY DeTrey]) were applied on the treated dentin surfaces. The specimens were stored at 37°C and 100% humidity for 24 h. After storage, shear bond strength (SBS) was measured and data analyzed with nonparametric ANOVA followed by Wilcoxon rank sum tests. Results: Substance loss (medians) was 19 µm in Group 3 and 113 µm in Group 4. SBS-values (MPa; medians) in Group 2 (9.24) were significantly lower than in Group 1 (13.15; p=0.0069), Group 3 (13.05; p=0.01), and Group 4 (13.02; p=0.0142). There were no significant differences in SBS between Groups 1, 3, and 4 (p≥0.8063). Conclusion: Airborne-particle abrasion and diamond bur preparation restored bond strength of Scotchbond Universal to sclerotic dentin to the level of non-sclerotic dentin, with airborne-particle abrasion being less invasive than diamond bur preparation.