30 resultados para Non book materials

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: To assess the reliability of computed tomography (CT) numbers, also known as Hounsfield-units (HU) in the differentiation and identification of forensically relevant materials and to provide instructions to improve the reproducibility of HU measurements in daily forensic practice. MATERIALS AND METHODS: We scanned a phantom containing non-organic materials (glass, rocks and metals) on three different CT scanners with standardized parameters. The t-test was used to assess the influence of the scanner, the size and shape of different types of regions-of-interest (ROI), the composition and shape of the object, and the reader performance on HU measurements. Intra-class correlation coefficient was used to assess intra- and inter-reader reliability. RESULTS: HU values did not change significantly as a function of ROI-shape or -size (p>0.05). Intra-reader reliability reached ICC values >0.929 (p<0.001). Inter-reader reliability was also excellent with an ICC of 0.994 (p<0.001). Four of seven objects yielded significantly different CT numbers at different levels within the object (p<0.05). In 6/7 objects the HU changed significantly from CT scanner to CT scanner (p<0.05). CONCLUSION: Reproducible CT number measurements can be achieved through correct ROI-placement and repeat measurements within the object of interest. However, HU may differ from CT-scanner to CT-scanner. In order to obtain comparable CT numbers we suggest that a dedicated Forensic Reference Phantom be developed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The history of cerebral aneurysm surgery owes a great tribute to the tenacity of pioneering neurosurgeons who designed and developed the clips used to close the aneurysms neck. However, until the beginning of the past century, surgery of complex and challenging aneurysms was impossible due to the lack of surgical microscope and commercially available sophisticated clips. The modern era of the spring clips began in the second half of last century. Until then, only malleable metal clips and other non-metallic materials were available for intracranial aneurysms. Indeed, the earliest clips were hazardous and difficult to handle. Several neurosurgeons put their effort in developing new clip models, based on their personal experience in the treatment of cerebral aneurysms. Finally, the introduction of the surgical microscope, together with the availability of more sophisticated clips, has allowed the treatment of complex and challenging aneurysms. However, today none of the new instruments or tools for surgical therapy of aneurysms could be used safely and effectively without keeping in mind the lessons on innovative surgical techniques provided by great neurovascular surgeons. Thanks to their legacy, we can now treat many types of aneurysms that had always been considered inoperable. In this article, we review the basic principles of surgical clipping and illustrate some more advanced techniques to be used for complex aneurysms.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Summary The first part of this review examined ISO approval requirements and in vitro testing. In the second part, non-standardized test methods for composite materials are presented and discussed. Physical tests are primarily described. Analyses of surface gloss and alterations, as well as aging simulations of dental materials are presented. Again, the importance of laboratory tests in determining clinical outcomes is evaluated. Differences in the measurement protocols of the various testing institutes and how these differences can in?uence the results are also discussed. Because there is no standardization of test protocols, the values determined by different institutes cannot be directly compared. However, the ranking of the tested materials should be the same if a valid protocol is applied by different institutes. The modulus of elasticity, the expansion after water sorption, and the polishability of the material are all clinically relevant, whereas factors measured by other test protocols may have no clinical correlation. The handling properties of the materials are highly dependent on operators' preferences. Therefore, no standard values can be given.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Peri-implantitis is common in patients with dental implants. We performed a single-blinded longitudinal randomized study to assess the effects of mechanical debridement on the peri-implant microbiota in peri-implantitis lesions. MATERIALS AND METHODS: An expanded checkerboard DNA-DNA hybridization assay encompassing 79 different microorganisms was used to study bacterial counts before and during 6 months following mechanical treatment of peri-implantitis in 17 cases treated with curettes and 14 cases treated with an ultrasonic device. Statistics included non-parametric tests and GLM multivariate analysis with p<0001 indicating significance and 80% power. RESULTS: At selected implant test sites, the most prevalent bacteria were: Fusobacterium nucleatum sp., Staphylococci sp., Aggregatibacter actinomycetemcomitans, Helicobacter pylori, and Tannerella forsythia. 30 min. after treatment with curettes, A. actinomycetemcomitans (serotype a), Lactobacillus acidophilus, Streptococcus anginosus, and Veillonella parvula were found at lower counts (p<0.001). No such differences were found for implants treated with the ultrasonic device. Inconsistent changes occurred following the first week. No microbiological differences between baseline and 6-month samples were found for any species or between treatment study methods in peri-implantitis. CONCLUSIONS: Both methods failed to eliminate or reduce bacterial counts in peri-implantitis. No group differences were found in the ability to reduce the microbiota in peri-implantitis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Suture materials in orthopaedic surgery are used for closure of wounds, repair of fascia, muscles, tendons, ligaments, joint capsules, and cerclage or tension band of certain fractures. The purpose of this study was to compare the biomechanical properties of eleven commonly used sutures in orthopaedic surgery. Three types of braided non-absorbable and one type of braided absorbable suture material with different calibers (n=77) underwent biomechanical testing for maximum load to failure, strain, and stiffness. All samples were tied by one surgeon with a single SMC (Seoul Medical Center) knot and three square knots. The maximum load to failure and strain were highest for #5 FiberWire and lowest for #0 Ethibond Excel (p<0.001). The stiffness was highest for #5 FiberWire and lowest for #2-0 Vicryl (p<0.001). In all samples, the failure of the suture material occurred at the knot There was no slippage of the knot in any of the samples tested. This data will assist the orthopaedic surgeon in selection and application of appropriate suture materials and calibers to specific tasks.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study evaluated how applicable European Life Cycle Inventory (LCI) data are to assessing the environmental impacts of the life cycle of Brazilian triple superphosphate (TSP). The LCI data used for the comparison were local Brazilian LCI data, European LCI data in its original version from the ecoinvent database and a modified version of the European LCI data, which had been adapted to better account for the Brazilian situation. We compared the three established datasets at the level of the inventory as well as for their environmental impacts, i.e. at the level of Life Cycle Environmental Assessment (LCIA). The analysis showed that the European LCIs (both the original and the modified ones) considered a broader spectrum of background processes and environmental flows (inputs and outputs). Nevertheless, TSP production had in all three cases similar values for the consumption of the main raw materials. The LCIA results obtained for the datasets showed important differences as well. Therefore we concluded that the European data in general lead to much higher environmental impacts than the Brazilian data. The differences between the LCIA results obtained with the Brazilian and the European data can be basically explained by the methodological differences underlying the data. The small differences at the LCI level for selected inputs and outputs between the Brazilian and the European LCIs from ecoinvent indicate that the latter can be regarded as applicable for characterizing the Brazilian TSP.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

http://www.woodheadpublishing.com/en/book.aspx?bookID=1598

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: This investigation was a basal study that used a mouse model of xerostomia to identify protein biomarkers of xerostomia in saliva. We identified genes expressed differently in parotid glands from non-obese diabetic mice with diabetes and those from control mice; subsequently, we investigated expression of the proteins encoded by these genes in parotid glands and saliva. MATERIALS AND METHODS: DNA microarray and real-time PCR analyses were performed to detect differences between NOD/ShiJcl and C57BL/6JJcl (control) female mice in gene expression from parotid glands or parotid acinar cells. Subsequently, protein expression was assessed using immunoblotting and immunohistochemistry. Similarly, enzyme activity in saliva was assessed using zymography. RESULTS: Based on gene expression analyses, Chia expression was higher in diabetic mice than non-diabetic mice and control mice; similarly, expression of chitinase, the protein encoded by Chia, was higher in diabetic mice. Saliva from NOD/ShiJcl mice had more chitinase than saliva from control mice. CONCLUSIONS: Chitinase was highly expressed in parotid acinar cells from diabetic mice compared with non-diabetic and control mice. Increased chitinase expression and enzyme activity may characterize the autoimmune diabetes in mice; however, further investigation is required to assess its use as a biomarker of xerostomia in humans.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To compare the effects on heart rate (HR), on left ventricular (LV) or arterial pressures, and the general safety of a non-ionic low-osmolar contrast medium (CM) and a non-ionic iso-osmolar CM in patients undergoing cardiac angiography (CA) or peripheral intra-arterial digital subtraction angiography (IA-DSA). MATERIALS AND METHODS: Two double-blind, randomized studies were conducted in 216 patients who underwent CA (n=120) or peripheral IA-DSA (n=96). Patients referred for CA received a low-osmolar monomeric CM (iomeprol-350, n=60) or an iso-osmolar dimeric CM (iodixanol-320; n=60). HR and LV peak systolic and end-diastolic pressures were determined before and after the first injection during left and right coronary arteriography and left ventriculography. Monitoring for all types of adverse event (AE) was performed for 24 h following the procedure. t-tests were performed to compare CM for effects on HR. Patients referred for IA-DSA received iomeprol-300 (n=49) or iodixanol-320 (n=47). HR and arterial blood pressure (BP) were evaluated before and after the first 4 injections. Monitoring for AE was performed for 4 h following the procedure. Repeated-measures ANOVA was used to compare mean HR changes across the first 4 injections, whereas changes after the first injection were compared using t-tests. RESULTS: No significant differences were noted between iomeprol and iodixanol in terms of mean changes in HR during left coronary arteriography (p=0.8), right coronary arteriography (p=0.9), and left ventriculography (p=0.8). In patients undergoing IA-DSA, no differences between CM were noted for effects on mean HR after the first injection (p=0.6) or across the first 4 injections (p=0.2). No significant differences (p>0.05) were noted in terms of effects on arterial BP in either study or on LV pressures in patients undergoing CA. Non-serious AE considered possibly CM-related (primarily headache and events affecting the cardiovascular and digestive systems) were reported more frequently by patients undergoing CA and more frequently after iodixanol (14/60 [23.3%] and 2/47 [4.3%]; CA and IA-DSA, respectively) than iomeprol (10/60 [16.7%] and 1/49 [2%], respectively). CONCLUSIONS: Iomeprol and iodixanol are safe and have equally negligible effects on HR and LV pressures or arterial BP during and after selective intra-cardiac injection and peripheral IA-DSA. CLINICAL APPLICATION: Iomeprol and iodixanol are safe and equally well tolerated with regard to cardiac rhythm and clinical preference should be based on diagnostic image quality alone.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

GOAL OF THE WORK: Anemia is a common side effect of chemotherapy. Limited information exists about its incidence and risk factors. The objective of this study was to evaluate the incidence of anemia and risk factors for anemia occurrence in patients with early breast cancer who received adjuvant chemotherapy. MATERIALS AND METHODS: We evaluated risk factors for anemia in pre- and post/perimenopausal patients with lymph node-positive early breast cancer treated with adjuvant chemotherapy in two randomized trials. All patients received four cycles of doxorubicin and cyclophosphamide (AC) followed by three cycles of cyclophosphamide, methotrexate, fluorouracil (CMF). Anemia incidence was related to baseline risk factors. Multivariable analysis used logistic and Cox regression. MAIN RESULTS: Among the 2,215 available patients, anemia was recorded in 11% during adjuvant chemotherapy. Grade 2 and 3 anemia occurred in 4 and 1% of patients, respectively. Pretreatment hemoglobin and white blood cells (WBC) were significant predictors of anemia. Adjusted odds ratios (logistic regression) comparing highest versus lowest quartiles were 0.18 (P < 0.0001) for hemoglobin and 0.52 (P = 0.0045) for WBC. Age, surgery type, platelets, body mass index, and length of time from surgery to chemotherapy were not significant predictors. Cox regression results looking at time to anemia were similar. CONCLUSIONS: Moderate or severe anemia is rare among patients treated with AC followed by CMF. Low baseline hemoglobin and WBC are associated with a higher risk of anemia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: Many flow-cytometric cell characterization methods require costly markers and colour reagents. We present here a novel device for cell discrimination based on impedance measurement of electrical cell properties in a microfluidic chip, without the need of extensive sample preparation steps and the requirement of labelling dyes. MATERIALS AND METHODS, RESULTS: We demonstrate that in-flow single cell measurements in our microchip allow for discrimination of various cell line types, such as undifferentiated mouse fibroblasts 3T3-L1 and adipocytes on the one hand, or human monocytes and in vitro differentiated dendritic cells and macrophages on the other hand. In addition, viability and apoptosis analyses were carried out successfully for Jurkat cell models. Studies on several species, including bacteria or fungi, demonstrate not only the capability to enumerate these cells, but also show that even other microbiological life cycle phases can be visualized. CONCLUSIONS: These results underline the potential of impedance spectroscopy flow cytometry as a valuable complement to other known cytometers and cell detection systems.