15 resultados para New Technology

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

During the past decade microbeam radiation therapy has evolved from preclinical studies to a stage in which clinical trials can be planned, using spatially fractionated, highly collimated and high intensity beams like those generated at the x-ray ID17 beamline of the European Synchrotron Radiation Facility. The production of such microbeams typically between 25 and 100 microm full width at half maximum (FWHM) values and 100-400 microm center-to-center (c-t-c) spacings requires a multislit collimator either with fixed or adjustable microbeam width. The mechanical regularity of such devices is the most important property required to produce an array of identical microbeams. That ensures treatment reproducibility and reliable use of Monte Carlo-based treatment planning systems. New high precision wire cutting techniques allow the fabrication of these collimators made of tungsten carbide. We present a variable slit width collimator as well as a single slit device with a fixed setting of 50 microm FWHM and 400 microm c-t-c, both able to cover irradiation fields of 50 mm width, deemed to meet clinical requirements. Important improvements have reduced the standard deviation of 5.5 microm to less than 1 microm for a nominal FWHM value of 25 microm. The specifications of both devices, the methods used to measure these characteristics, and the results are presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The investigation of the consequences of new technologies has a long standing tradition within economics. Particularly, labor economists are wondering how the introduction of new technologies, e.g. Personal Computers, have shaped labor markets. Former research has concentrated on the question of whether on-the-job use of PCs creates a wage bonus for employees. In this paper, we investigate whether the use of PCs increases employees’ probability of an upward shift in their employment status and whether it reduces the risk of involuntary labor market exits. We do so by applying event history analysis to the Swiss Labor Market Survey, a random sample of 3028 respondents, and by analyzing a Panel sub-sample of 650 respondents conducted recently in Switzerland. Our results show that on-the-job use of PCs was beneficial for employees in the past by increasing their probability of an upward shift by approximately 50%. The analysis also suggests that PC use reduces the risk and duration of unemployment. However, these latter results fail to reach statistical significance.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Benign Prostatic Hyperplasia is a common entity among the aging male population. Its prevalence is increasing with age and is around 80% in the over 80-years old. The androgen-estrogen ratio changes in favor of the estrogens, which leads to a growth of prostatic tissue, presenting histologically as hyperplasia. BPH can cause irritative or obstructive symptoms or both. Nowadays we speak of bladder storage or bladder voiding symptoms, summarised as LUTS (Lower Urinary Tract Symptoms). LUTS has a structural and a functional component, the structural being caused by the size of the adenoma itself the functional depending on the muscle tone of the bladder neck and the prostatic urethra. To investigate LUTS, we use validated symptom scores, sonography for residual urine and eventually a urodynamic evaluation. There are 3 grades of BPH. The indication for an interventional therapy is relative in BPH II, and absolute in BPH III. Prior to treatment, other diseases mimicking the same symptoms, have to be ruled out and adequatly treated. Electro-resection of the prostate (TUR-P) remains the standard therapy and the benchmark any new technology has to compete with. TUR-P has good short- and longterm results, but can be associated with a considerable perioperative morbidity, and the learning curve for the operator is long. The most promising of the newer techniques is the Holmium-Laser-Enucleation of the prostate (Laser-TUR-P), showing at least identical short- and median-term results, but a lower perioperative morbidity than TUR-P For several minimally-invasive techniques, indications are limited. TUMT TUNA, WIT and laser-coagulation all produce a coagulation necrosis of the prostatic tissue by thermic damage with secondary tissue shrinking. Urodynamic results however, are not comparable to TUR-P or Laser-TUR-P, and significantly more secondary interventions within 2 to 5 years are required. Minimal-invasive techniques present a favorable alternative for younger patients without complications of BPH, and for older patients with relevant comorbidities, and can usually be performed under local anaesthesia. The morbidity is low and further therapies remain possible later, if necessary.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The development of emergency medical services and especially neurosurgical emergencies during recent decades has necessitated the development of novel tools. Although the gadgets that the neurosurgeon uses today in emergencies give him important help in diagnosis and treatment, we still need new technology, which has rapidly developed. This review presents the latest diagnostic tools, which offer precious help in everyday emergency neurosurgery practice. New ultrasound devices make the diagnosis of haematomas easier. In stroke, the introduction of noninvasive new gadgets aims to provide better treatment to the patient. Finally, the entire development of computed tomography and progress in radiology have resulted in innovative CT scans and angiographic devices that advance the diagnosis, treatment, and outcome of the patent. The pressure on physicians to be quick and effective and to avoid any misjudgement of the patient has been transferred to the technology, with the emphasis on developing new systems that will provide our patients with a better outcome and quality of life.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

How do developers and designers of a new technology make sense of intended users? The critical groundwork for user-centred technology development begins not by involving actual users' exposure to the technological artefact but much earlier, with designers' and developers' vision of future users. Thus, anticipating intended users is critical to technology uptake. We conceptualise the anticipation of intended users as a form of prospective sensemaking in technology development. Employing a narrative analytical approach and drawing on four key communities in the development of Grid computing, we reconstruct how each community anticipated the intended Grid user. Based on our findings, we conceptualise user anticipation in Terms of two key dimensions, namely the intended possibility to inscribe user needs into the technological artefact as well as the intended scope of the application domain. In turn, these dimensions allow us to develop an initial typology of intended user concepts that in turn might provide a key building block towards a generic typology of intended users.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Thoracic endovascular aortic repair (TEVAR) represents an attractive alternative to open aortic repair (OAR). The aim of this study was to assess outcome and quality of life in patients treated either by TEVAR or OAR for diseased descending thoracic aorta. METHODS: A post hoc analysis of a prospectively collected consecutive series of 136 patients presenting with surgical diseases of the descending aorta between January 2001 and December 2005 was conducted. Fourteen patients were excluded because of involvement of the ascending aorta. Assessed treatment cohorts were TEVAR (n = 52) and OAR (n = 70). Mean follow-up was 34 +/- 18 months. End points were perioperative and late mortality rates and long-term quality of life as assessed by the Short Form Health Survey (SF-36) and Hospital Anxiety and Depression Score questionnaires. RESULTS: Mean age was significantly higher in TEVAR patients (69 +/- 10 years versus 62 +/- 15 years; p = 0.002). Perioperative mortality rates were 9% (OAR) and 8% (TEVAR), respectively (p = 0.254). Accordingly, cumulative long-term mortality rates were similar in both cohorts. Overall quality-of-life scores were 93 (63-110, OAR) and 83 (60-112, TEVAR), respectively. Normal quality-of-life scores range from 85 to 115. Anxiety and depression scores were not increased after open surgery. CONCLUSIONS: Thoracic endovascular aortic repair and OAR both provide excellent long-term results in treatment of thoracic aortic disease. Long-term quality of life, however, is reduced after thoracic aortic repair. Interestingly, TEVAR patients did not score higher in overall quality of life despite all advantages of minimized access trauma. Similarly, anxiety and depression scores are not reduced by TEVAR, possibly reflecting a certain caution against the new technology.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

An increasing number of lipid mediators have been identified as key modulators of immunity. Among these is a family of glycolipids capable of cellular uptake, loading onto the MHC-like molecule CD1d and stimulation of NKT cells. NKT cells are particularly interesting because they bridge innate and adaptive immunity by coordinating the early events of dendritic cell maturation, recruitment of NK cells, CD4 and CD8 T cells, and B cells at the site of microbial injury. As such, their therapeutic manipulation could be of the greatest interest in vaccine design or active immunotherapy. However, the use of NKT cells as cellular adjuvant of immunity in the clinic will require a better knowledge of the pharmacology of lipid agonists in order to optimize their action and avoid potential unseen off-target effects. We have been studying extracellular transport and cellular uptake of NKT agonists for the past few years. This field is confronted to a very limited prior knowledge and a small set of usable tools. New technology must be put in place and adapted to answering basic immunology questions related to NKT cells. The intimate link between the pharmacology of glycolipids and lipid metabolism makes us believe that great variations of bioactivity could be seen in the general population when NKT agonists are used therapeutically.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The robotic approach in thoracic surgery has rapidly gained popularity in recent years. As with the introduction of any new technology, this warrants not only adaptation of the operative technique itself, but also the evolution of appropriate troubleshooting strategies. A selected number of helpful tips and technical procedural manoeuvres have been compiled to prevent intraoperative problems, as well as to overcome challenging situations that can arise during robotic lobectomies. In robotic surgery, as opposed to open surgery or video-assisted thoracic surgery, these tips serve an important purpose for the operating surgeon, as well as the entire surgical team involved in the procedure. All the assembled recommendations have proved their effectiveness and have been successfully used by the authors in many procedures. Furthermore, these manoeuvres have been found to be of great importance in the training and proctoring of thoracic surgeons, fellows and residents (bed-side assistants). This guide of clearly arranged tips and troubleshooting strategies offers surgeons a useful tool to overcome difficult situations in robotic lobectomy and preferably improve the reproducibility and safety of their procedures.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND AND AIMS Combined multichannel intraluminal impedance and esophageal manometry (MII-EM) measures concomitantly bolus transit and pressure changes allowing determination of the functional impact of esophageal motility abnormalities. Ten years ago our laboratory reported MII-EM results in 350 consecutive patients. Since then high-resolution impedance manometry (HRIM) became available and the definitions of ineffective esophageal motility (IEM) and nutcracker esophagus were revised. The aim of this study was to assess the impact of these developments on esophageal function testing. METHODS From August 2012 through May 2013, HRIM was performed in 350 patients referred for esophageal function testing. Each patient received 10 liquid and 10 viscous swallows. While taking advantage of the new technology and revised criteria, HRIM findings were classified according to the conventional criteria to allow more appropriate comparison with our earlier analysis. RESULTS Compared with the study performed 10 years ago, the prevalence of normal manometry (36% vs. 35%), achalasia (7% vs. 8%), scleroderma (1% vs. 1%), hypertensive lower esophageal sphincter (LES) (7% vs. 7%), and hypotensive LES (1% vs. 2%) remained the same, whereas the prevalence of distal esophageal spasm (9% vs. 3%), nutcracker esophagus (9% vs. 3%), and poorly relaxing LES (10% vs. 3%) decreased and the prevalence of IEM increased (20% vs. 31%) significantly. Compared with the early study, normal liquid bolus transit was significantly different in patients with hypertensive LES (96% vs. 57%) and poorly relaxing LES (55% vs. 100%). CONCLUSIONS This study brings to light the increase in prevalence of IEM. In addition, it suggests that the hypertensive LES and poorly relaxing LES may each affect bolus transit in about half of these patients.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective. To compare hearing and speech understanding between a new, nonskin penetrating Baha system (Baha Attract) to the current Baha system using a skin-penetrating abutment. Methods. Hearing and speech understanding were measured in 16 experienced Baha users. The transmission path via the abutment was compared to a simulated Baha Attract transmission path by attaching the implantable magnet to the abutment and then by adding a sample of artificial skin and the external parts of the Baha Attract system. Four different measurements were performed: bone conduction thresholds directly through the sound processor (BC Direct), aided sound field thresholds, aided speech understanding in quiet, and aided speech understanding in noise. Results. The simulated Baha Attract transmission path introduced an attenuation starting from approximately 5 dB at 1000 Hz, increasing to 20–25 dB above 6000 Hz. However, aided sound field threshold shows smaller differences and aided speech understanding in quiet and in noise does not differ significantly between the two transmission paths. Conclusion. The Baha Attract system transmission path introduces predominately high frequency attenuation. This attenuation can be partially compensated by adequate fitting of the speech processor. No significant decrease in speech understanding in either quiet or in noise was found.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Androgens are precursors for sex steroids and are predominantly produced in the human gonads and the adrenal cortex. They are important for intrauterine and postnatal sexual development and human reproduction. Although human androgen biosynthesis has been extensively studied in the past, exact mechanisms underlying the regulation of androgen production in health and disease remain vague. Here, the knowledge on human androgen biosynthesis and regulation is reviewed with a special focus on human adrenal androgen production and the hyperandrogenic disorder of polycystic ovary syndrome (PCOS). Since human androgen regulation is highly specific without a good animal model, most studies are performed on patients harboring inborn errors of androgen biosynthesis, on human biomaterials and human (tumor) cell models. In the past, most studies used a candidate gene approach while newer studies use high throughput technologies to identify novel regulators of androgen biosynthesis. Using genome wide association studies on cohorts of patients, novel PCOS candidate genes have been recently described. Variant 2 of the DENND1A gene was found overexpressed in PCOS theca cells and confirmed to enhance androgen production. Transcriptome profiling of dissected adrenal zones established a role for BMP4 in androgen synthesis. Similarly, transcriptome analysis of human adrenal NCI-H295 cells identified novel regulators of androgen production. Kinase p38α (MAPK14) was found to phosphorylate CYP17 for enhanced 17,20 lyase activity and RARB and ANGPTL1 were detected in novel networks regulating androgens. The discovery of novel players for androgen biosynthesis is of clinical significance as it provides targets for diagnostic and therapeutic use.