4 resultados para NICKEL-TITANIUM INSTRUMENTS
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
BACKGROUND/OBJECTIVES The purpose of this study was to compare the mechanical, structural, and aesthetic properties of two types of aesthetic coated nickel-titanium (NiTi) wires compared with comparable regular NiTi wires in the as-received state and after clinical use. MATERIALS/METHODS Sixty one subjects were randomly assigned to four groups (N = 61), two groups of coated wires and two groups of comparable, non-coated controls (n = 15/group). The period in the mouth ranged from 4 to 12 weeks after insertion. In total, 121 wires (61 retrieved and 60 as-received) were used in the study. The percentages of coating retention and loss were extrapolated from scans. A brief survey of five questions with three choices was given to all patients. Differential scanning calorimetry (DSC) and three-point bending tests were done on as-received and used wires. RESULTS The surface characterization by the percentage of resin remaining indicated that most wires in both test groups lost a significant amount of coating. A patient survey indicated that this was a noticeable feature for patients. DSC analysis of the wires indicated that the metallurgical properties of the coated wires were not similar to the uncoated wires in the as-received condition. Three-point bending results indicate a wide variation in test results with large standard deviations among all the groups. LIMITATIONS The extent of coating loss requires investigating, as do the biological properties of the detached coating. CONCLUSIONS Both wires lost a significant amount of aesthetic coating after varying periods in the mouth. The metallurgical testing of these findings may indicate that these wires perform differently in the mouth.
Resumo:
OBJECTIVES To identify the timing of significant arch dimensional increases during orthodontic alignment involving round and rectangular nickel-titanium (NiTi) wires and rectangular stainless steel (SS). A secondary aim was to compare the timing of changes occurring with conventional and self-ligating fixed appliance systems. METHODS In this non-primary publication, additional data from a multicenter randomised trial initially involving 96 patients, aged 16 years and above, were analysed. The main pre-specified outcome measures were the magnitude and timing of maxillary intercanine, interpremolar, and intermolar dimensions. Each participant underwent alignment with a standard Damon (Ormco, Orange, CA) wire sequence for a minimum of 34 weeks. Blinding of clinicians and patients was not possible; however, outcome assessors and data analysts were kept blind to the appliance type during data analysis. RESULTS Complete data were obtained from 71 subjects. Significant arch dimensional changes were observed relatively early in treatment. In particular, changes in maxillary inter-first and second premolar dimensions occurred after alignment with an 0.014in. NiTi wire (P<0.05). No statistical differences in transverse dimensions were found between rectangular NiTi and working SS wires for each transverse dimension (P>0.05). Bracket type had no significant effect on the timing of the transverse dimensional changes. CONCLUSIONS Arch dimensional changes were found to occur relatively early in treatment, irrespective of the appliance type. Nickel-titanium wires may have a more profound effect on transverse dimensions than previously believed. CLINICAL SIGNIFICANCE On the basis of this research orthodontic expansion may occur relatively early in treatment. Nickel-titanium wires may have a more profound effect on transverse dimensions than previously believed.
Resumo:
Soft X-ray lasing across a Ni-like plasma gain-medium requires optimum electron temperature and density for attaining to the Ni-like ion stage and for population inversion in the View the MathML source3d94d1(J=0)→3d94p1(J=1) laser transition. Various scaling laws, function of operating parameters, were compared with respect to their predictions for optimum temperatures and densities. It is shown that the widely adopted local thermodynamic equilibrium (LTE) model underestimates the optimum plasma-lasing conditions. On the other hand, non-LTE models, especially when complemented with dielectronic recombination, provided accurate prediction of the optimum plasma-lasing conditions. It is further shown that, for targets with Z equal or greater than the rare-earth elements (e.g. Sm), the optimum electron density for plasma-lasing is not accessible for pump-pulses at View the MathML sourceλ=1ω=1μm. This observation explains a fundamental difficulty in saturating the wavelength of plasma-based X-ray lasers below 6.8 nm, unless using 2ω2ω pumping.