15 resultados para Multivariate unit root tests

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

India’s success story in services is well documented at the national level, but similar literature does not exist for India’s states. In this paper, we bridge this gap in research by looking at India’s services growth at the sub-national level and in doing so, also challenge existing literature by arguing that this growth has positive implications for income distribution. We find that even as per capita income is not converging across India’s states, per capita services are; evidence is provided both in terms of traditional measures of sigma- and beta-convergence and more recent panel unit root tests. A more disaggregated analysis of services sectors reveals convergence in railways, public administration and financial services. Finally, a Jensen & Kletzer (2005) approach to determining tradability provides evidence of most services being “traded” across India’s states, suggesting the role of such trade in the services growth and convergence story.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

India’s success story in services is well documented at the national level, but similar literature does not exist for India’s states. In this paper, we bridge this gap in research by looking at India’s services growth at the sub-national level and in doing so, also challenge existing literature by arguing that this growth has positive implications for income distribution. The first interesting finding is that even as per capita income is not converging across India’s states, per capita services are and we provide evidence for this both in terms of traditional measures of sigma- and beta-convergence and more recent panel unit root tests. Secondly, not only is external demand an important determinant of services value added at the state level, but this demand also emanates from all over the country rather than being concentrated in the neighbouring or richer states. This suggests that the benefits from services growth are being distributed more widely than may be perceived.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Writing unit tests for legacy systems is a key maintenance task. When writing tests for object-oriented programs, objects need to be set up and the expected effects of executing the unit under test need to be verified. If developers lack internal knowledge of a system, the task of writing tests is non-trivial. To address this problem, we propose an approach that exposes side effects detected in example runs of the system and uses these side effects to guide the developer when writing tests. We introduce a visualization called Test Blueprint, through which we identify what the required fixture is and what assertions are needed to verify the correct behavior of a unit under test. The dynamic analysis technique that underlies our approach is based on both tracing method executions and on tracking the flow of objects at runtime. To demonstrate the usefulness of our approach we present results from two case studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of the study was to evaluate the impact of smoking on a prolongated chlorhexidine digluconate regimen after scaling and root planing. Forty-two smokers (test group) and 85 nonsmoking patients (control group) with generalized chronic periodontitis were examined for clinical attachment level (CAL), probing depth (PD), bleeding on probing (BoP), and Plaque Index (Pl) at baseline and after 1 and 3 months. During scaling and root planing, a 0.2% chlorhexidine digluconate solution and a 1% chlorhexidine digluconate gel were used. The subjects used a 0.2% chlorhexidine digluconate solution twice daily for 3 months. The Mann-Whitney U and Wilcoxon tests were used for statistical analysis. There were significant improvements of all studied variables after 1 and 3 months in both groups. After 3 months, the mean improvement in the test group was 1.62 mm for CAL, 2.85 mm for PD, and 48% for BoP; in the control group, the values were 2.18 mm for CAL, 2.81 mm for PD, and 47% for BoP. Only the maximum changes of CAL between 1 and 3 months (test group, 0.32 mm vs 0.69 mm in the control group) and PD (test group, 0.47 mm vs 0.76 mm in the control group) were significantly different between the groups (P < .05 and P = .05, respectively). The present data appear to suggest that the use of chlorhexidine digluconate twice daily during a period of 3 months following nonsurgical periodontal therapy may result in significant clinical improvements in smokers and nonsmokers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIM: To assess survival rates and complications of root-filled teeth restored with or without post-and-core systems over a mean observation period of >or=4 years. METHODOLOGY: A total of 325 single- and multirooted teeth in 183 subjects treated in a private practice were root filled and restored with either a cast post-and-core or with a prefabricated titanium post and composite core. Root-filled teeth without post-retained restorations served as controls. The restored teeth served as abutments for single unit metal-ceramic or composite crowns or fixed bridges. Teeth supporting cantilever bridges, overdentures or telescopic crowns were excluded. RESULTS: Seventeen teeth in 17 subjects were lost to follow-up (17/325: 5.2%). The mean observation period was 5.2 +/- 1.8 (SD) years for restorations with titanium posts, 6.2 +/- 2.0 (SD) years for cast post-and-cores and 4.4 +/- 1.7 (SD) years for teeth without posts. Overall, 54% of build-ups included the incorporation of a titanium post and 26.5% the cementation of a cast post-and-core. The remaining 19.5% of the teeth were restored without intraradicular retention. The adjusted 5-year tooth survival rate amounted to 92.5% for teeth restored with titanium posts, to 97.1% for teeth restored with cast post-and-cores and to 94.3% for teeth without post restorations, respectively. The most frequent complications included root fracture (6.2%), recurrent caries (1.9%), post-treatment periradicular disease (1.6%) and loss of retention (1.3%). CONCLUSION: Provided that high-quality root canal treatment and restorative protocols are implemented, high survival and low complication rates of single- and multirooted root-filled teeth used as abutments for fixed restorations can be expected after a mean observation period of >or=4 years.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the diagnosis of diabetic autonomic neuropathy (DAN) various autonomic tests are used. We took a novel statistical approach to find a combination of autonomic tests that best separates normal controls from patients with DAN.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mechanical testing of the periodontal ligament requires a practical experimental model. Bovine teeth are advantageous in terms of size and availability, but information is lacking as to the anatomy and histology of their periodontium. The aim of this study, therefore, was to characterize the anatomy and histology of the attachment apparatus in fully erupted bovine mandibular first molars. A total of 13 teeth were processed for the production of undecalcified ground sections and decalcified semi-thin sections, for NaOH maceration, and for polarized light microscopy. Histomorphometric measurements relevant to the mechanical behavior of the periodontal ligament included width, number, size and area fraction of blood vessels and fractal analysis of the two hard-soft tissue interfaces. The histological and histomorphometric analyses were performed at four different root depths and at six circumferential locations around the distal and mesial roots. The variety of techniques applied provided a comprehensive view of the tissue architecture of the bovine periodontal ligament. Marked regional variations were observed in width, surface geometry of the two bordering hard tissues (cementum and alveolar bone), structural organization of the principal periodontal ligament connective tissue fibers, size, number and numerical density of blood vessels in the periodontal ligament. No predictable pattern was observed, except for a statistically significant increase in the area fraction of blood vessels from apical to coronal. The periodontal ligament width was up to three times wider in bovine teeth than in human teeth. The fractal analyses were in agreement with the histological observations showing frequent signs of remodeling activity in the alveolar bone - a finding which may be related to the magnitude and direction of occlusal forces in ruminants. Although samples from the apical root portion are not suitable for biomechanical testing, all other levels in the buccal and lingual aspects of the mesial and distal roots may be considered. The bucco-mesial aspect of the distal root appears to be the most suitable location.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: It is unclear whether very old patients benefit from organized inpatient (stroke unit) care. The aim of this work was to compare the clinical outcome of patients with first-ever ischemic stroke aged either >or=80 or <80 years who were treated conservatively (without cerebral revascularization) in a university-based stroke unit. PATIENTS AND METHODS: We included 147 (11%) patients >or=80 years and 1241 (89%) patients, <80 years. All patients underwent clinical examination, blood tests, electrocardiography (ECG), brain imaging and cerebrovascular ultrasound. Additional investigations were done at the discretion of the treating physician. The modified Rankin scale (mRS) score was used to assess the 3-month outcome (favorable: mRS, 0-1; poor: mRS, 2-6; death of any cause). RESULTS: Stroke severity did not differ between both groups [median National Institutes of Health Stroke Scale (NIHSS) score, 4]. Younger patients underwent magnetic resonance (MR) imaging of the brain, MR and catheter angiography and echocardiography (p<0.001) more frequently, whereas older patients underwent computed tomography of the brain and 24-hour ECG (p<0.001) more frequently. Stroke prevention included clopidogrel (p<0.001) and heparin (p=0.047) more often in older patients and aspirin (p=0.016) in younger patients. Recurrent ischemic events were similarly frequent in old (7%) and young (5%) patients. Favorable outcome was equally prevalent in old (71%) and young (76%) patients, whereas mortality was higher in older patients (7 and 3%, p=0.007). Admission NIHSS score >or=12 was the only independent predictor of unfavorable outcome (odds ratio, 19.6; 95% confidence interval, 9.7-39.6; p<0.001). CONCLUSION: Our work provides further evidence that also the oldest patients may benefit from conservative stroke unit care.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A comparison between an unconstrained and a partially constrained system for in vitro biomechanical testing of the L5-S1 spinal unit was conducted. The objective was to compare the compliance and the coupling of the L5-S1 unit measured with an unconstrained and a partially constrained test for the three major physiological motions of the human spine. Very few studies have compared unconstrained and partially constrained testing systems using the same cadaveric functional spinal units (FSUs). Seven human L5-S1 units were therefore tested on both a pneumatic, unconstrained, and a servohydraulic, partially constrained system. Each FSU was tested along three motions: flexion-extension (FE), lateral bending (LB) and axial rotation (AR). The obtained kinematics on both systems is not equivalent, except for the FE case, where both motions are similar. The directions of coupled motions were similar for both tests, but their magnitudes were smaller in the partially constrained configuration. The use of a partially constrained system to characterize LB and AR of the lumbosacral FSU decreased significantly the measured stiffness of the segment. The unconstrained system is today's "gold standard" for the characterization of FSUs. The selected partially constrained method seems also to be an appropriate way to characterize FSUs for specific applications. Care should be taken using the latter method when the coupled motions are important.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives The aim of this study was to measure the degree of conversion (DC) of five dual-curing resin cements after different curing modes with a second- and a third-generation light-emitting diode (LED) curing unit. Additionally, irradiance of both light curing units was measured at increasing distances and through discs of two glass ceramics for computer-aided design/manufacturing (CAD/CAM). Materials and methods Irradiance and spectra of the Elipar FreeLight 2 (Standard Mode (SM)) and of the VALO light curing unit (High Power Mode (HPM) and Xtra Power Mode (XPM)) were measured with a MARC radiometer. Irradiance was measured at increasing distances (control) and through discs (1.5 to 6 mm thickness) of IPS Empress CAD and IPS e.max CAD. DC of Panavia F2.0, RelyX Unicem 2 Automix, SpeedCEM, BisCem, and BeautiCem SA was measured with an attenuated total reflectance–Fourier transform infrared spectrometer when self-cured (negative control) or light cured in SM for 40 s, HPM for 32 s, or XPM for 18 s. Light curing was performed directly (positive control) or through discs of either 1.5- or 3-mm thickness of IPS Empress CAD or IPS e.max CAD. DC was analysed with Kruskal–Wallis tests followed by pairwise Wilcoxon rank sum tests (α = 0.05). Results Maximum irradiances were 1,545 mW/cm2 (SM), 2,179 mW/cm2 (HPM), and 4,156 mW/cm2 (XPM), and all irradiances decreased by >80 % through discs of 1.5 mm, ≥95 % through 3 mm, and up to >99 % through 6 mm. Generally, self-curing resulted in the lowest DC. For some cements, direct light curing did not result in higher DC compared to when light cured through ceramic discs. For other cements, light curing through ceramic discs of 3 mm generally reduced DC. Conclusions Light curing was favourable for dual-curing cements. Some cements were more susceptible to variations in curing mode than others. Clinical relevance When light curing a given cement, the higher irradiances of the third-generation LED curing unit resulted in similar DC compared to the second-generation one, though at shorter light curing times.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To analyze the precision of fit of implant-supported screw-retained computer-aided-designed and computer-aided-manufactured (CAD/CAM) zirconium dioxide (ZrO) frameworks. MATERIALS AND METHODS Computer-aided-designed and computer-aided-manufactured ZrO frameworks (NobelProcera) for a screw-retained 10-unit implant-supported reconstruction on six implants (FDI positions 15, 13, 11, 21, 23, 25) were fabricated using a laser (ZrO-L, N = 6) and a mechanical scanner (ZrO-M, N = 5) for digitizing the implant platform and the cuspid-supporting framework resin pattern. Laser-scanned CAD/CAM titanium (TIT-L, N = 6) and cast CoCrW-alloy frameworks (Cast, N = 5) fabricated on the same model and designed similar to the ZrO frameworks were the control. The one-screw test (implant 25 screw-retained) was applied to assess the vertical microgap between implant and framework platform with a scanning electron microscope. The mean microgap was calculated from approximal and buccal values. Statistical comparison was performed with non-parametric tests. RESULTS No statistically significant pairwise difference was observed between the relative effects of vertical microgap between ZrO-L (median 14 μm; 95% CI 10-26 μm), ZrO-M (18 μm; 12-27 μm) and TIT-L (15 μm; 6-18 μm), whereas the values of Cast (236 μm; 181-301 μm) were significantly higher (P < 0.001) than the three CAD/CAM groups. A monotonous trend of increasing values from implant 23 to 15 was observed in all groups (ZrO-L, ZrO-M and Cast P < 0.001, TIT-L P = 0.044). CONCLUSIONS Optical and tactile scanners with CAD/CAM technology allow for the fabrication of highly accurate long-span screw-retained ZrO implant-reconstructions. Titanium frameworks showed the most consistent precision. Fit of the cast alloy frameworks was clinically inacceptable.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

SUMMARY BACKGROUND/OBJECTIVES Orthodontic management of maxillary canine impaction (MCI), including forced eruption, may result in significant root resorption; however, the association between MCI and orthodontically induced root resorption (OIRR) is not yet sufficiently established. The purpose of this retrospective cohort study was to comparatively evaluate the severity of OIRR of maxillary incisors in orthodontically treated patients with MCI. Additionally, impaction characteristics were associated with OIRR severity. SUBJECTS AND METHODS The sample comprised 48 patients undergoing fixed-appliance treatment-24 with unilateral/bilateral MCI and 24 matched controls without impaction. OIRR was calculated using pre- and post-operative panoramic tomograms. The orientation of eruption path, height, sector location, and follicle/tooth ratio of the impacted canine were also recorded. Mann-Whitney U-test and univariate and multivariate linear mixed models were used to test for the associations of interest. RESULTS Maxillary central left incisor underwent more OIRR in the impaction group (mean difference = 0.58mm, P = 0.04). Overall, the impaction group had 0.38mm more OIRR compared to the control (95% confidence interval, CI: 0.03, 0.74; P = 0.04). However, multivariate analysis demonstrated no difference in the amount of OIRR between impaction and non-impaction groups overall. A positive association between OIRR and initial root length was observed (95% CI: 0.08, 0.27; P < 0.001). The severity of canine impaction was not found to be a significant predictor of OIRR. LIMITATIONS This study was a retrospective study and used panoramic tomograms for OIRR measurements. CONCLUSIONS This study indicates that MCI is a weak OIRR predictor. Interpretation of the results needs caution due to the observational nature of the present study.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND CONTEXT The nerve root sedimentation sign in transverse magnetic resonance imaging has been shown to discriminate well between selected patients with and without lumbar spinal stenosis (LSS), but the performance of this new test, when used in a broader patient population, is not yet known. PURPOSE To evaluate the clinical performance of the nerve root sedimentation sign in detecting central LSS above L5 and to determine its potential significance for treatment decisions. STUDY DESIGN Retrospective cohort study. PATIENT SAMPLE One hundred eighteen consecutive patients with suspected LSS (52% women, median age 62 years) with a median follow-up of 24 months. OUTCOME MEASURES Oswestry disability index (ODI) and back and leg pain relief. METHODS We performed a clinical test validation study to assess the clinical performance of the sign by measuring its association with health outcomes. Subjects were patients referred to our orthopedic spine unit from 2004 to 2007 before the sign had been described. Based on clinical and radiological diagnostics, patients had been treated with decompression surgery or nonsurgical treatment. Changes in the ODI and pain from baseline to 24-month follow-up were compared between sedimentation sign positives and negatives in both treatment groups. RESULTS Sixty-nine patients underwent surgery. Average baseline ODI in the surgical group was 54.7%, and the sign was positive in 39 patients (mean ODI improvement 29.0 points) and negative in 30 (ODI improvement 28.4), with no statistically significant difference in ODI and pain improvement between groups. In the 49 patients of the nonsurgical group, mean baseline ODI was 42.4%; the sign was positive in 18 (ODI improvement 0.6) and negative in 31 (ODI improvement 17.7). A positive sign was associated with a smaller ODI and back pain improvement than negative signs (both p<.01 on t test). CONCLUSIONS In patients commonly treated with decompression surgery, the sedimentation sign does not appear to predict surgical outcome. In nonsurgically treated patients, a positive sign is associated with more limited improvement. In these cases, surgery might be effective, but this needs investigation in prospective randomized trials (Australian New Zealand Clinical Trial Registry, number ACTRN12610000567022).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To investigate the effect of airborne-particle abrasion or diamond bur preparation as pretreatment steps of non-carious cervical root dentin regarding substance loss and bond strength. Methods: 45 dentin specimens produced from crowns of extracted human incisors by grinding the labial surfaces with silicon carbide papers (control) were treated with one of three adhesive systems (Group 1A-C; A: OptiBond FL, B: Clearfil SE Bond, or C: Scotchbond Universal; n=15/adhesive system). Another 135 dentin specimens (n=15/group) produced from the labial, non-carious cervical root part of extracted human incisors were treated with one of the adhesive systems after either no pre-treatment (Group 2A-C), pre-treatment with airborne-particle abrasion (CoJet Prep and 50 µm aluminum oxide powder; Group 3A-C), or pre-treatment with diamond bur preparation (40 µm grit size; Group 4A-C). Substance loss caused by the pre-treatment was measured in Groups 3 and 4. After treatment with the adhesive systems, resin composite was applied and all specimens were stored (37°C, 100% humidity, 24 hours) until measurement of microshear bond strength (µSBS). Data were analyzed with a nonparametric ANOVA followed by Kruskal-Wallis and Wilcoxon rank sum tests (level of significance: alpha=0.05). Results: Overall substance loss was significantly lower in Group 3 (median: 19 µm) than in Group 4 (median: 113 µm; p<0.0001). There were no significant differences in µSBS between the adhesive systems (A-C) in Group 1, Group 3, and Group 4 (p>=0.133). In Group 2, OptiBond FL (Group 2A) and Clearfil SE Bond (Group 2B) yielded significantly higher µSBS than Scotchbond Universal (Group 2C; p<=0.032). For OptiBond FL and Clearfil SE Bond, there were no significant differences in µSBS between the ground crown dentin and the non-carious cervical root dentin regardless of any pre-treatment of the latter (both p=0.661). For Scotchbond Universal, the µSBS to non-carious cervical root dentin without pre-treatment was significantly lower than to ground crown dentin and to non-carious cervical root dentin pre-treated with airborne-particle abrasion or diamond bur preparation p<=0.014).