35 resultados para Multiple inteligences assessment

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE: To determine sensitivity, specificity and inter-observer variability of different whole-body MRI (WB-MRI) sequences in patients with multiple myeloma (MM). METHODS AND MATERIALS: WB-MRI using a 1.5T MRI scanner was performed in 23 consecutive patients (13 males, 10 females; mean age 63+/-12 years) with histologically proven MM. All patients were clinically classified according to infiltration (low-grade, n=7; intermediate-grade, n=7; high-grade, n=9) and to the staging system of Durie and Salmon PLUS (stage I, n=12; stage II, n=4; stage III, n=7). The control group consisted of 36 individuals without malignancy (25 males, 11 females; mean age 57+/-13 years). Two observers independently evaluated the following WB-MRI sequences: T1w-TSE (T1), T2w-TIRM (T2), and the combination of both sequences, including a contrast-enhanced T1w-TSE with fat-saturation (T1+/-CE/T2). They had to determine growth patterns (focal and/or diffuse) and the MRI sequence that provided the highest confidence level in depicting the MM lesions. Results were calculated on a per-patient basis. RESULTS: Visual detection of MM was as follows: T1, 65% (sensitivity)/85% (specificity); T2, 76%/81%; T1+/-CE/T2, 67%/88%. Inter-observer variability was as follows: T1, 0.3; T2, 0.55; T1+/-CE/T2, 0.55. Sensitivity improved depending on infiltration grade (T1: 1=60%; 2=36%; 3=83%; T2: 1=70%; 2=71%; 3=89%; T1+/-CE/T2: 1=50%; 2=50%; 3=89%) and clinical stage (T1: 1=58%; 2=63%; 3=79%; T2: 1=58%; 2=88%; 3=100%; T1+/-CE/T2: 1=50%; 2=63%; 3=100%). T2w-TIRM sequences achieved the best reliability in depicting the MM lesions (65% in the mean of both readers). CONCLUSIONS: T2w-TIRM sequences achieved the highest level of sensitivity and best reliability, and thus might be valuable for initial assessment of MM. For an exact staging and grading the examination protocol should encompass unenhanced and enhanced T1w-MRI sequences, in addition to T2w-TIRM.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

When observers are presented with two visual targets appearing in the same position in close temporal proximity, a marked reduction in detection performance of the second target has often been reported, the so-called attentional blink phenomenon. Several studies found a similar decrement of P300 amplitudes during the attentional blink period as observed with detection performances of the second target. However, whether the parallel courses of second target performances and corresponding P300 amplitudes resulted from the same underlying mechanisms remained unclear. The aim of our study was therefore to investigate whether the mechanisms underlying the AB can be assessed by fixed-links modeling and whether this kind of assessment would reveal the same or at least related processes in the behavioral and electrophysiological data. On both levels of observation three highly similar processes could be identified: an increasing, a decreasing and a u-shaped trend. Corresponding processes from the behavioral and electrophysiological data were substantially correlated, with the two u-shaped trends showing the strongest association with each other. Our results provide evidence for the assumption that the same mechanisms underlie attentional blink task performance at the electrophysiological and behavioral levels as assessed by fixed-links models.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: Sensor-based recordings of human movements are becoming increasingly important for the assessment of motor symptoms in neurological disorders beyond rehabilitative purposes. ASSESS MS is a movement recording and analysis system being developed to automate the classification of motor dysfunction in patients with multiple sclerosis (MS) using depth-sensing computer vision. It aims to provide a more consistent and finer-grained measurement of motor dysfunction than currently possible. Objective: To test the usability and acceptability of ASSESS MS with health professionals and patients with MS. Methods: A prospective, mixed-methods study was carried out at 3 centers. After a 1-hour training session, a convenience sample of 12 health professionals (6 neurologists and 6 nurses) used ASSESS MS to capture recordings of standardized movements performed by 51 volunteer patients. Metrics for effectiveness, efficiency, and acceptability were defined and used to analyze data captured by ASSESS MS, video recordings of each examination, feedback questionnaires, and follow-up interviews. Results: All health professionals were able to complete recordings using ASSESS MS, achieving high levels of standardization on 3 of 4 metrics (movement performance, lateral positioning, and clear camera view but not distance positioning). Results were unaffected by patients’ level of physical or cognitive disability. ASSESS MS was perceived as easy to use by both patients and health professionals with high scores on the Likert-scale questions and positive interview commentary. ASSESS MS was highly acceptable to patients on all dimensions considered, including attitudes to future use, interaction (with health professionals), and overall perceptions of ASSESS MS. Health professionals also accepted ASSESS MS, but with greater ambivalence arising from the need to alter patient interaction styles. There was little variation in results across participating centers, and no differences between neurologists and nurses. Conclusions: In typical clinical settings, ASSESS MS is usable and acceptable to both patients and health professionals, generating data of a quality suitable for clinical analysis. An iterative design process appears to have been successful in accounting for factors that permit ASSESS MS to be used by a range of health professionals in new settings with minimal training. The study shows the potential of shifting ubiquitous sensing technologies from research into the clinic through a design approach that gives appropriate attention to the clinic environment.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: Multiple True-False-Items (MTF-Items) might offer some advantages compared to one-best-answer-questions (TypeA) as they allow more than one correct answer and may better represent clinical decisions. However, in medical education assessment MTF-Items are seldom used. Summary of Work: With this literature review existing findings on MTF-items and on TypeA were compared along the Ottawa Criteria for Good Assessment, i.e. (1) reproducibility, (2) feasibility, (3) validity, (4) acceptance, (5) educational effect, (6) catalytic effects, and (7) equivalence. We conducted a literature research on ERIC and Google Scholar including papers from the years 1935 to 2014. We used the search terms “multiple true-false”, “true-false”, “true/false”, and “Kprim” combined with “exam”, “test”, and “assessment”. Summary of Results: We included 29 out of 33 studies. Four of them were carried out in the medical field Compared to TypeA, MTF-Items are associated with (1) higher reproducibility (2) lower feasibility (3) similar validity (4) higher acceptance (5) higher educational effect (6) no studies on catalytic effects or (7) equivalence. Discussion and Conclusions: While studies show overall good characteristics of MTF items according to the Ottawa criteria, this type of question seems to be rather seldom used. One reason might be the reported lower feasibility. Overall the literature base is still weak. Furthermore, only 14 % of literature is from the medical domain. Further studies to better understand the characteristics of MTF-Items in the medical domain are warranted. Take-home messages: Overall the literature base is weak and therefore further studies are needed. Existing studies show that: MTF-Items show higher reliability, acceptance and educational effect; MTF-Items are more difficult to produce

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: It is yet unclear if there are differences between using electronic key feature problems (KFPs) or electronic case-based multiple choice questions (cbMCQ) for the assessment of clinical decision making. Summary of Work: Fifth year medical students were exposed to clerkships which ended with a summative exam. Assessment of knowledge per exam was done by 6-9 KFPs, 9-20 cbMCQ and 9-28 MC questions. Each KFP consisted of a case vignette and three key features (KF) using “long menu” as question format. We sought students’ perceptions of the KFPs and cbMCQs in focus groups (n of students=39). Furthermore statistical data of 11 exams (n of students=377) concerning the KFPs and (cb)MCQs were compared. Summary of Results: The analysis of the focus groups resulted in four themes reflecting students’ perceptions of KFPs and their comparison with (cb)MCQ: KFPs were perceived as (i) more realistic, (ii) more difficult, (iii) more motivating for the intense study of clinical reasoning than (cb)MCQ and (iv) showed an overall good acceptance when some preconditions are taken into account. The statistical analysis revealed that there was no difference in difficulty; however KFP showed a higher discrimination and reliability (G-coefficient) even when corrected for testing times. Correlation of the different exam parts was intermediate. Conclusions: Students perceived the KFPs as more motivating for the study of clinical reasoning. Statistically KFPs showed a higher discrimination and higher reliability than cbMCQs. Take-home messages: Including KFPs with long menu questions into summative clerkship exams seems to offer positive educational effects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Java Enterprise Applications (JEAs) are large systems that integrate multiple technologies and programming languages. With the purpose to support the analysis of JEAs we have developed MooseJEE an extension of the \emphMoose environment capable to model the typical elements of JEAs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hemorrhage and traumatic coagulopathyis are major causes of early death in multiply injured patients. Thrombelastography (TEG) seems to be a fast and accurate coagulation test in trauma care. We suggest that multiply injured trauma patients would benefit the most from an early assessment of coagulation by TEG, mainly RapidTEG, to detect an acute traumatic coagulopathy and especially primary fibrinolysis, which is related with high mortality. This review gives an overview on TEG and its clinical applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Enantioselective CE with sulfated cyclodextrins as chiral selectors was used to determine the CYP3A4-catalyzed N-demethylation kinetics of ketamine to norketamine and its inhibition in the presence of ketoconazole in vitro. Ketamine, a chiral phencyclidine derivative, was incubated with recombinant human CYP3A4 from a baculovirus expression system as racemic mixture and as single enantiomer. Alkaline liquid/liquid extracts of the samples were analyzed with a pH 2.5 buffer comprising 50 mM Tris and phosphoric acid together with either multiple isomer sulfated β-cyclodextrin (10 mg/mL) or highly sulfated γ-cyclodextrin (2%, w/v). Data obtained in the absence of ketoconazole revealed that the N-demethylation occurred stereoselectively with Michaelis-Menten (incubation of racemic ketamine) and Hill (separate incubation of single enantiomers) kinetics. Data generated in the presence of ketoconazole as the inhibitor could best be fitted to a one-site competitive model and inhibition constants were calculated using the equation of Cheng and Prusoff. No stereoselective difference was observed, but inhibition constants for the incubation of racemic ketamine were found to be larger compared with those obtained with the incubation of single ketamine enantiomers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Objectives: To assess the reporting quality of Cochrane and non-Cochrane systematic reviews (SR) in orthodontics and to compare the reporting quality (PRISMA score) with methodological quality (AMSTAR criteria). Materials and Methods: Systematic reviews (n  =  109) published between January 2000 and July 2011 in five leading orthodontic journals were identified and included. The quality of reporting of the included reviews was assessed by two authors in accordance with the PRISMA guidelines. Each article was assigned a cumulative grade based on fulfillment of the applicable criteria, and an overall percentage score was assigned. Descriptive statistics and simple and multiple linear regression analyses were undertaken. Results: The mean overall PRISMA score was 64.1% (95% confidence interval [CI], 62%-65%). The quality of reporting was considerably better in reviews published in the Cochrane Database of Systematic Reviews (P < .001) than in non-Cochrane reviews. Both multivariable and univariable analysis indicated that journal of publication and number of authors was significantly associated with the PRISMA score. The association between AMSTAR score and modified PRISMA score was also found to be highly statistically significant. Conclusion: Compliance of orthodontic SRs published in orthodontic journals with PRISMA guidelines was deficient in several areas. The quality of reporting assessed using PRISMA guidelines was significantly better in orthodontic SRs published in the Cochrane Database of Systematic Reviews.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to refine a multi-dimensional scale based on physiological and behavioural parameters, known as the post abdominal surgery pain assessment scale (PASPAS), to quantify pain after laparotomy in horses. After a short introduction, eight observers used the scale to assess eight horses at multiple time points after laparotomy. In addition, a single observer was used to test the correlation of each parameter with the total pain index in 34 patients, and the effect of general anaesthesia on PASPAS was investigated in a control group of eight horses. Inter-observer variability was low (coefficient of variation 0.3), which indicated good reliability of PASPAS. The correlation of individual parameters with the total pain index differed between parameters. PASPAS, which was not influenced by general anaesthesia, was a useful tool to evaluate pain in horses after abdominal surgery and may also be useful to investigate analgesic protocols or for teaching purposes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background For reliable assessment of ventilation inhomogeneity, multiple-breath washout (MBW) systems should be realistically validated. We describe a new lung model for in vitro validation under physiological conditions and the assessment of a new nitrogen (N2)MBW system. Methods The N2MBW setup indirectly measures the N2 fraction (FN2) from main-stream carbon dioxide (CO2) and side-stream oxygen (O2) signals: FN2 = 1−FO2−FCO2−FArgon. For in vitro N2MBW, a double chamber plastic lung model was filled with water, heated to 37°C, and ventilated at various lung volumes, respiratory rates, and FCO2. In vivo N2MBW was undertaken in triplets on two occasions in 30 healthy adults. Primary N2MBW outcome was functional residual capacity (FRC). We assessed in vitro error (√[difference]2) between measured and model FRC (100–4174 mL), and error between tests of in vivo FRC, lung clearance index (LCI), and normalized phase III slope indices (Sacin and Scond). Results The model generated 145 FRCs under BTPS conditions and various breathing patterns. Mean (SD) error was 2.3 (1.7)%. In 500 to 4174 mL FRCs, 121 (98%) of FRCs were within 5%. In 100 to 400 mL FRCs, the error was better than 7%. In vivo FRC error between tests was 10.1 (8.2)%. LCI was the most reproducible ventilation inhomogeneity index. Conclusion The lung model generates lung volumes under the conditions encountered during clinical MBW testing and enables realistic validation of MBW systems. The new N2MBW system reliably measures lung volumes and delivers reproducible LCI values.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This field study examined the vitellogenin (VTG) biomarker response under conditions of low and fluctuating activities of environmental estrogenicity. The present study was performed on immature brown trout (Salmo trutta) exposed to the small river Luetzelmurg, which is located in the prealpine Swiss midland region and receives effluents from a single sewage treatment plant (STP). To understand better factors influencing the relationship between estrogenic exposure and VTG induction, we compared VTG levels in caged (stationary) and feral (free-ranging) fish, VTG levels in fish from up- and downstream of the STP, and two different methods for quantifying VTG (enzyme-linked immunosorbent assay vs real-time reverse transcription-polymerase chain reaction), and we used passive samplers (polar organic chemical integrative sampler [POCIS]) to integrate the variable, bioaccumulative estrogenic load in the river water over time. The POCIS from the downstream site contained approximately 20-fold higher levels of bioassay-derived estrogen equivalents than the POCIS from the upstream site. In feral fish, this site difference in estrogenic exposure was reflected in VTG protein levels but not in VTG mRNA. In contrast, in caged fish, the site difference was evident only for VTG mRNA but not for VTG protein. Thus, the outcome of VTG biomarker measurements varied with the analytical detection method (protein vs mRNA) and with the exposure modus (caged vs feral). Our findings suggest that for environmental situations with low and variable estrogenic contamination, a multiple-assessment approach may be necessary for the assessment of estrogenic exposure in fish.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We evaluated the suitability of single and multiple cell type cultures as model systems to characterise cellular kinetics of highly lipophilic compounds with potential ecotoxicological impact. Confluent mono-layers of human skin fibroblasts, rat astrocytoma C6 cells, non-differentiated and differentiated mouse 3T3 cells were kept in culture medium supplemented with 10% foetal calf serum. For competitive uptake experiments up to four different cell types, grown on glass sectors, were exposed for 3h to (14)C-labelled model compounds, dissolved either in organic solvents or incorporated into unilamellar lecithin liposomes. Bromo-, or chloro-benzenes, decabromodiphenylether (DBP), and dichlorodiphenyl ethylene (DDE) were tested in rather high concentration of 20 microM. Cellular toxicity was low. Compound levels were related to protein, DNA, and triglyceride contents. Cellular uptake was fast and dependent on physico-chemical properties of the compounds (lipophilicity, molecular size), formulation, and cell type. Mono-halogenated benzenes showed low and similar uptake levels (=low accumulation compounds). DBP and DDE showed much higher cellular accumulations (=high accumulation compounds) except for DBP in 3T3 cells. Uptake from liposomal formulations was mostly higher than if compounds were dissolved in organic solvents. The extent of uptake correlated with the cellular content of triglycerides, except for DBP. Uptake competition between different cell types was studied in a sectorial multi-cell culture model. For low accumulation compounds negligible differences were found among C6 cells and fibroblasts. Uptake of DDE was slightly and that of DBP highly increased in fibroblasts. Well-defined cell culture systems, especially the sectorial model, are appropriate to screen for bioaccumulation and cytotoxicity of (unknown) chemical entities in vitro.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Assessment of lung volume (FRC) and ventilation inhomogeneities with ultrasonic flowmeter and multiple breath washout (MBW) has been used to provide important information about lung disease in infants. Sub-optimal adjustment of the mainstream molar mass (MM) signal for temperature and external deadspace may lead to analysis errors in infants with critically small tidal volume changes during breathing. METHODS: We measured expiratory temperature in human infants at 5 weeks of age and examined the influence of temperature and deadspace changes on FRC results with computer simulation modeling. A new analysis method with optimized temperature and deadspace settings was then derived, tested for robustness to analysis errors and compared with the previously used analysis methods. RESULTS: Temperature in the facemask was higher and variations of deadspace volumes larger than previously assumed. Both showed considerable impact upon FRC and LCI results with high variability when obtained with the previously used analysis model. Using the measured temperature we optimized model parameters and tested a newly derived analysis method, which was found to be more robust to variations in deadspace. Comparison between both analysis methods showed systematic differences and a wide scatter. CONCLUSION: Corrected deadspace and more realistic temperature assumptions improved the stability of the analysis of MM measurements obtained by ultrasonic flowmeter in infants. This new analysis method using the only currently available commercial ultrasonic flowmeter in infants may help to improve stability of the analysis and further facilitate assessment of lung volume and ventilation inhomogeneities in infants.