40 resultados para Multiple Baseline Design

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: Several clinical studies on chronic stroke conducted with end-effector-based robots showed improvement of the motor function in the affected arm. Compared to end-effector-based robots, exoskeleton robots provide improved guidance of the human limb and are better suited to train task-oriented movements with a large range of motions. OBJECTIVE: To test whether intensive arm training with the arm exoskeleton ARMin I is feasible with chronic-stroke patients and whether it improves motor function in the paretic arm. METHODS: Three single cases with chronic hemiparesis resulting from unilateral stroke (at least 14 months after stroke). A-B design with 2 weeks of multiple baseline measurements (A), 8 weeks of training (B) with repetitive measurements and a follow-up measurement 8 weeks after training. The training included shoulder and elbow movements with the robotic rehabilitation device ARMin I. Two subjects had three 1-hour sessions per week and 1 subject received five 1-hour sessions per week. The main outcome measurement was the upper-limb part of the Fugl-Meyer Assessment (FMA). RESULTS: The ARMin training was well tolerated by the patients, and the FMA showed moderate, but significant improvements for all 3 subjects (p < 0.05). Most improvements were maintained 8 weeks after discharge. CONCLUSIONS: This study indicates that intensive training with an arm exoskeleton is feasible with chronic-stroke patients. Moderate improvements were found in all 3 subjects, thus further clinical investigations are justified.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The sleep electroencephalogram (EEG) spectrum is unique to an individual and stable across multiple baseline recordings. The aim of this study was to examine whether the sleep EEG spectrum exhibits the same stable characteristics after acute total sleep deprivation. Polysomnography (PSG) was recorded in 20 healthy adults across consecutive sleep periods. Three nights of baseline sleep [12 h time in bed (TIB)] following 12 h of wakefulness were interleaved with three nights of recovery sleep (12 h TIB) following 36 h of sustained wakefulness. Spectral analysis of the non-rapid eye movement (NREM) sleep EEG (C3LM derivation) was used to calculate power in 0.25 Hz frequency bins between 0.75 and 16.0 Hz. Intraclass correlation coefficients (ICCs) were calculated to assess stable individual differences for baseline and recovery night spectra separately and combined. ICCs were high across all frequencies for baseline and recovery and for baseline and recovery combined. These results show that the spectrum of the NREM sleep EEG is substantially different among individuals, highly stable within individuals and robust to an experimental challenge (i.e. sleep deprivation) known to have considerable impact on the NREM sleep EEG. These findings indicate that the NREM sleep EEG represents a trait.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE : To describe the methodology and to present the baseline findings of the Attention-deficit/hyperactivity Disorder Observational Research in Europe (ADORE) study, the primary objective of which is to describe the relationship between treatment regimen prescribed and quality of life of children with ADHD in actual practice. METHODS : In this 2-year prospective observational study, data on diagnosis, prescribed treatment and outcomes of ADHD were collected at seven time points by paediatricians and child psychiatrists on 1,573 children recruited in 10 European countries. The data presented here from the 1,478 patients included in the analyses describe the baseline condition, initial treatment regimen prescribed and quality of life of families with children with ADHD. RESULTS : Patients had a mean age of 9.0 years (SD 2.5) and 84% were male. Physicians diagnoses were made using DSM-IV (43 %), ICD-10 (32%) and both DSM-IV and ICD-10 (12 %). Mean age of awareness of a problem was 5.1 years, suggesting an average delay of approximately 4 years between awareness and diagnosis of ADHD. Baseline ADHD rating scale scores (physicianrated) indicated moderate to severe ADHD. Parent-rated SDQ scores were in agreement and suggested significant levels of co-existing problems. CGI-S, CGAS and CHIPCE scores also indicated significant impairment. Patients were offered the following treatments after the initial assessment: pharmacotherapy (25 %), psychotherapy (19 %), combination of pharmacotherapy and psychotherapy (25 %), other therapy (10 %) and no treatment (21 %). CONCLUSION : The ADORE study shows that ADHD is similarly recognised across 10 European countries and that the children are significantly impaired across a wide range of domains. In this respect, they resemble children described in previous ADHD samples.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Statins have anti-inflammatory and immunomodulatory properties in addition to their lipid-lowering effects. Currently, the effects of statins on multiple sclerosis are still controversial. Therefore, randomized clinical trials are needed to provide better evidence on the therapeutic potential of statins in multiple sclerosis. The SWiss Atorvastatin and Interferon Beta-1b trial in Multiple Sclerosis (SWABIMS) evaluates the efficacy, safety and tolerability of atorvastatin 40 mg per os daily and subcutaneous interferon beta-1b every other day compared to monotherapy with subcutaneous interferon beta-1b every other day in patients with relapsing-remitting multiple sclerosis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND A newly developed collagen matrix (CM) of porcine origin has been shown to represent a potential alternative to palatal connective tissue grafts (CTG) for the treatment of single Miller Class I and II gingival recessions when used in conjunction with a coronally advanced flap (CAF). However, at present it remains unknown to what extent CM may represent a valuable alternative to CTG in the treatment of Miller Class I and II multiple adjacent gingival recessions (MAGR). The aim of this study was to compare the clinical outcomes following treatment of Miller Class I and II MAGR using the modified coronally advanced tunnel technique (MCAT) in conjunction with either CM or CTG. METHODS Twenty-two patients with a total of 156 Miller Class I and II gingival recessions were included in this study. Recessions were randomly treated according to a split-mouth design by means of MCAT + CM (test) or MCAT + CTG (control). The following measurements were recorded at baseline (i.e. prior to surgery) and at 12 months: Gingival Recession Depth (GRD), Probing Pocket Depth (PD), Clinical Attachment Level (CAL), Keratinized Tissue Width (KTW), Gingival Recession Width (GRW) and Gingival Thickness (GT). GT was measured 3-mm apical to the gingival margin. Patient acceptance was recorded using a Visual Analogue Scale (VAS). The primary outcome variable was Complete Root Coverage (CRC), secondary outcomes were Mean Root Coverage (MRC), change in KTW, GT, patient acceptance and duration of surgery. RESULTS Healing was uneventful in both groups. No adverse reactions at any of the sites were observed. At 12 months, both treatments resulted in statistically significant improvements of CRC, MRC, KTW and GT compared with baseline (p < 0.05). CRC was found at 42% of test sites and at 85% of control sites respectively (p < 0.05). MRC measured 71 ± 21% mm at test sites versus 90 ± 18% mm at control sites (p < 0.05). Mean KTW measured 2.4 ± 0.7 mm at test sites versus 2.7 ± 0.8 mm at control sites (p > 0.05). At test sites, GT values changed from 0.8 ± 0.2 to 1.0 ± 0.3 mm, and at control sites from 0.8 ± 0.3 to 1.3 ± 0.4 mm (p < 0.05). Duration of surgery and patient morbidity was statistically significantly lower in the test compared with the control group respectively (p < 0.05). CONCLUSIONS The present findings indicate that the use of CM may represent an alternative to CTG by reducing surgical time and patient morbidity, but yielded lower CRC than CTG in the treatment of Miller Class I and II MAGR when used in conjunction with MCAT.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In the field of thrombosis and haemostasis, many preanalytical variables influence the results of coagulation assays and measures to limit potential results variations should be taken. To our knowledge, no paper describing the development and maintenance of a haemostasis biobank has been previously published. Our description of the biobank of the Swiss cohort of elderly patients with venous thromboembolism (SWITCO65+) is intended to facilitate the set-up of other biobanks in the field of thrombosis and haemostasis. SWITCO65+ is a multicentre cohort that prospectively enrolled consecutive patients aged ≥65 years with venous thromboembolism at nine Swiss hospitals from 09/2009 to 03/2012. Patients will be followed up until December 2013. The cohort includes a biobank with biological material from each participant taken at baseline and after 12 months of follow-up. Whole blood from all participants is assayed with a standard haematology panel, for which fresh samples are required. Two buffy coat vials, one PAXgene Blood RNA System tube and one EDTA-whole blood sample are also collected at baseline for RNA/DNA extraction. Blood samples are processed and vialed within 1 h of collection and transported in batches to a central laboratory where they are stored in ultra-low temperature archives. All analyses of the same type are performed in the same laboratory in batches. Using multiple core laboratories increased the speed of sample analyses and reduced storage time. After recruiting, processing and analyzing the blood of more than 1,000 patients, we determined that the adopted methods and technologies were fit-for-purpose and robust.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this study was to explore whether it is possible to describe based on the International Classification of Functioning, Disability and Health (ICF) relevant aspects of functioning and disability affected in multiple sclerosis (MS) as well as environmental factors relevant to persons with MS. The specific aim was to identify most relevant 'Body functions', 'Body structures', 'Activities and participation', as well as 'Environmental factors' in patients with MS using the ICF. Additionally, different MS forms were compared with respect to the identified problems. A multi-centre study was conducted in an empirical cross-sectional design. Data from 205 individuals with MS were collected in rehabilitation centres: disease related data, socio-demographic data, single interviews based on the Extended ICF Checklist and a patient questionnaire including ratings on general health and functioning status, Beck Depression Inventory II (BDI-II) and Comorbidity Questionnaire (SCQ). The 129 ICF categories identified represent a comprehensive classification of functioning in MS from the clinical perspective. Differences between MS forms were observed for several ICF categories, EDSS, general health and functioning status, but not for BDI and SCQ. The study showed that it is possible to describe based on the ICF the spectrum in functioning and disability affected in MS as well as environmental factors relevant to persons with MS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The ACCESS trial examined the 12-month effectiveness of continuous therapeutic assertive community treatment (ACT) as part of integrated care compared to standard care in a catchment area comparison design in patients with schizophrenia spectrum disorders treated with quetiapine immediate release.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Modern methods in intensive care medicine often enable the survival of older critically ill patients. The short-term outcomes for patients treated in intensive care units (ICUs), such as survival to hospital discharge, are well documented. However, relatively little is known about subsequent long-term outcomes. Pain, anxiety and agitation are important stress factors for many critically ill patients. There are very few studies concerned with pain, anxiety and agitation and the consequences in older critically ill patients. The overall aim of this study is to identify how an ICU stay influences an older person's experiences later in life. More specific, this study has the following objectives: (1) to explore the relationship between pain, anxiety and agitation during ICU stays and experiences of the same symptoms in later life; and (2) to explore the associations between pain, anxiety and agitation experienced during ICU stays and their effect on subsequent health-related quality of life, use of the health care system (readmissions, doctor visits, rehabilitation, medication use), living situation, and survival after discharge and at 6 and 12 months of follow-up. Methods/Design A prospective, longitudinal study will be used for this study. A total of 150 older critically ill patients in the ICU will participate (ICU group). Pain, anxiety, agitation, morbidity, mortality, use of the health care system, and health-related quality of life will be measured at 3 intervals after a baseline assessment. Baseline measurements will be taken 48 hours after ICU admission and one week thereafter. Follow-up measurements will take place 6 months and 12 months after discharge from the ICU. To be able to interpret trends in scores on outcome variables in the ICU group, a comparison group of 150 participants, matched by age and gender, recruited from the Swiss population, will be interviewed at the same intervals as the ICU group. Discussion Little research has focused on long term consequences after ICU admission in older critically ill patients. The present study is specifically focussing on long term consequences of stress factors experienced during ICU admission.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Statins have anti-inflammatory and immunomodulatory properties in addition to lipid-lowering effects. The present study evaluated the effect of atorvastatin added to interferon beta-1b in multiple sclerosis (MS) in a multicenter, randomized, parallel-group, rater-blinded study performed in eight Swiss hospitals. Seventy-seven patients with relapsing-remitting MS started interferon beta-1b every other day. After 3 months, they were randomized 1:1 to receive atorvastatin 40 mg/day or not in addition to interferon beta-1b until month 15. The primary endpoint was the proportion of patients with new lesions on T2-weighted images at month 15 compared to baseline at month three. At study end, the proportion of patients with new lesions on T2-weighted images was equal in both groups (odds ratio 1.14; 95 % CI 0.36-3.56; p = 0.81). All predefined secondary endpoints including number of new lesions and total lesion volume on T2-weighted images, total number of new Gd-enhancing lesions on T1-weighted images, total brain volume, volume of grey matter, volume of white matter, EDSS, MSFC, relapse rate, time to first relapse, number of relapse-free patients and neutralizing antibodies did not show any significant differences (all p values >0.1). Transient elevations of liver enzymes were more frequent with atorvastatin (p = 0.02). In conclusion, atorvastatin 40 mg/day in addition to interferon beta-1b did not have a beneficial effect on relapsing-remitting MS compared to interferon beta-1b monotherapy over a 12-month period.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

One of the major challenges for a mission to the Jovian system is the radiation tolerance of the spacecraft (S/C) and the payload. Moreover, being able to achieve science observations with high signal to noise ratios (SNR), while passing through the high flux radiation zones, requires additional ingenuity on the part of the instrument provider. Consequently, the radiation mitigation is closely intertwined with the payload, spacecraft and trajectory design, and requires a systems-level approach. This paper presents a design for the Io Volcano Observer (IVO), a Discovery mission concept that makes multiple close encounters with Io while orbiting Jupiter. The mission aims to answer key outstanding questions about Io, especially the nature of its intense active volcanism and the internal processes that drive it. The payload includes narrow-angle and wide-angle cameras (NAC and WAC), dual fluxgate magnetometers (FGM), a thermal mapper (ThM), dual ion and neutral mass spectrometers (INMS), and dual plasma ion analyzers (PIA). The radiation mitigation is implemented by drawing upon experiences from designs and studies for missions such as the Radiation Belt Storm Probes (RBSP) and Jupiter Europa Orbiter (JEO). At the core of the radiation mitigation is IVO's inclined and highly elliptical orbit, which leads to rapid passes through the most intense radiation near Io, minimizing the total ionizing dose (177 krads behind 100 mils of Aluminum with radiation design margin (RDM) of 2 after 7 encounters). The payload and the spacecraft are designed specifically to accommodate the fast flyby velocities (e.g. the spacecraft is radioisotope powered, remaining small and agile without any flexible appendages). The science instruments, which collect the majority of the high-priority data when close to Io and thus near the peak flux, also have to mitigate transient noise in their detectors. The cameras use a combination of shielding and CMOS detectors with extremely fast readout to mi- imize noise. INMS microchannel plate detectors and PIA channel electron multipliers require additional shielding. The FGM is not sensitive to noise induced by energetic particles and the ThM microbolometer detector is nearly insensitive. Detailed SNR calculations are presented. To facilitate targeting agility, all of the spacecraft components are shielded separately since this approach is more mass efficient than using a radiation vault. IVO uses proven radiation-hardened parts (rated at 100 krad behind equivalent shielding of 280 mils of Aluminum with RDM of 2) and is expected to have ample mass margin to increase shielding if needed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The Baxter Amicus Version 2.51 (A) and the Gambro BCT Trima Accel Version 5.0 (T) cell separators may produce multiple platelet (PLT) concentrates within a single donation. STUDY DESIGN AND METHODS: The single-needle multiple plateletpheresis procedures of the two devices were compared in a prospective, randomized, paired crossover study in 60 donors. The 120 donations were compared for donor comfort, collection efficiency, residual white blood cell (WBC) count, and (in selected patients) corrected count increment (CCI). RESULTS: The mean PLT yield and the resultant mean number of units per donation were significantly lower for A (6.06 x 10(11) vs. 7.48 x 10(11) and 2.57 vs. 3.19, respectively, both p < 0.001), in spite of a longer apheresis duration (89 min vs. 79 min; p < 0.001). This resulted in a higher collection rate of T (5.68 x 10(11) PLTs/hr vs. 4.10 x 10(11) PLTs/hr, p < 0.001). Residual WBC count of every unit was fewer than 5 x 10(6), but significantly fewer A-PLT donations contained more than 10(5) WBCs per unit (1 vs. 9, p = 0.008). Although the ACD-A consumption was slightly higher for A (489 mL vs. 469 mL, p = 0.04), a trend to a higher frequency of side effects was found for T (42.4% vs. 23.7%, p = 0.06). The 1-hour CCIs of 33 transfused A-PLT units were comparable with those of 43 T-PLT units (11.8 vs. 13.9, p = 0.480). CONCLUSIONS: Both cell separators showed safe collections of up to 4 PLT units per donation with adequate CCI. T produced a higher PLT yield despite shorter apheresis duration, but with slightly higher residual WBC counts and a trend to a higher side-effect frequency.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To determine the accuracy of magnetic resonance imaging criteria for the early diagnosis of multiple sclerosis in patients with suspected disease. DESIGN: Systematic review. DATA SOURCES: 12 electronic databases, citation searches, and reference lists of included studies. Review methods Studies on accuracy of diagnosis that compared magnetic resonance imaging, or diagnostic criteria incorporating such imaging, to a reference standard for the diagnosis of multiple sclerosis. RESULTS: 29 studies (18 cohort studies, 11 other designs) were included. On average, studies of other designs (mainly diagnostic case-control studies) produced higher estimated diagnostic odds ratios than did cohort studies. Among 15 studies of higher methodological quality (cohort design, clinical follow-up as reference standard), those with longer follow-up produced higher estimates of specificity and lower estimates of sensitivity. Only two such studies followed patients for more than 10 years. Even in the presence of many lesions (> 10 or > 8), magnetic resonance imaging could not accurately rule multiple sclerosis in (likelihood ratio of a positive test result 3.0 and 2.0, respectively). Similarly, the absence of lesions was of limited utility in ruling out a diagnosis of multiple sclerosis (likelihood ratio of a negative test result 0.1 and 0.5). CONCLUSIONS: Many evaluations of the accuracy of magnetic resonance imaging for the early detection of multiple sclerosis have produced inflated estimates of test performance owing to methodological weaknesses. Use of magnetic resonance imaging to confirm multiple sclerosis on the basis of a single attack of neurological dysfunction may lead to over-diagnosis and over-treatment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Short-acting agents for neuromuscular block (NMB) require frequent dosing adjustments for individual patient's needs. In this study, we verified a new closed-loop controller for mivacurium dosing in clinical trials. METHODS: Fifteen patients were studied. T1% measured with electromyography was used as input signal for the model-based controller. After induction of propofol/opiate anaesthesia, stabilization of baseline electromyography signal was awaited and a bolus of 0.3 mg kg-1 mivacurium was then administered to facilitate endotracheal intubation. Closed-loop infusion was started thereafter, targeting a neuromuscular block of 90%. Setpoint deviation, the number of manual interventions and surgeon's complaints were recorded. Drug use and its variability between and within patients were evaluated. RESULTS: Median time of closed-loop control for the 11 patients included in the data processing was 135 [89-336] min (median [range]). Four patients had to be excluded because of sensor problems. Mean absolute deviation from setpoint was 1.8 +/- 0.9 T1%. Neither manual interventions nor complaints from the surgeons were recorded. Mean necessary mivacurium infusion rate was 7.0 +/- 2.2 microg kg-1 min-1. Intrapatient variability of mean infusion rates over 30-min interval showed high differences up to a factor of 1.8 between highest and lowest requirement in the same patient. CONCLUSIONS: Neuromuscular block can precisely be controlled with mivacurium using our model-based controller. The amount of mivacurium needed to maintain T1% at defined constant levels differed largely between and within patients. Closed-loop control seems therefore advantageous to automatically maintain neuromuscular block at constant levels.