5 resultados para Metal Doped Semiconductor
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Cell-based therapies and tissue engineering initiatives are gathering clinical momentum for next-generation treatment of tissue deficiencies. By using gravity-enforced self-assembly of monodispersed primary cells, we have produced adult and neonatal rat cardiomyocyte-based myocardial microtissues that could optionally be vascularized following coating with human umbilical vein endothelial cells (HUVECs). Within myocardial microtissues, individual cardiomyocytes showed native-like cell shape and structure, and established electrochemical coupling via intercalated disks. This resulted in the coordinated beating of microtissues, which was recorded by means of a multi-electrode complementary metal-oxide-semiconductor microchip. Myocardial microtissues (microm3 scale), coated with HUVECs and cast in a custom-shaped agarose mold, assembled to coherent macrotissues (mm3 scale), characterized by an extensive capillary network with typical vessel ultrastructures. Following implantation into chicken embryos, myocardial microtissues recruited the embryo's capillaries to functionally vascularize the rat-derived tissue implant. Similarly, transplantation of rat myocardial microtissues into the pericardium of adult rats resulted in time-dependent integration of myocardial microtissues and co-alignment of implanted and host cardiomyocytes within 7 days. Myocardial microtissues and custom-shaped macrotissues produced by cellular self-assembly exemplify the potential of artificial tissue implants for regenerative medicine.
Resumo:
RATIONALE AND OBJECTIVES: The aim of this study was to measure the radiation dose of dual-energy and single-energy multidetector computed tomographic (CT) imaging using adult liver, renal, and aortic imaging protocols. MATERIALS AND METHODS: Dual-energy CT (DECT) imaging was performed on a conventional 64-detector CT scanner using a software upgrade (Volume Dual Energy) at tube voltages of 140 and 80 kVp (with tube currents of 385 and 675 mA, respectively), with a 0.8-second gantry revolution time in axial mode. Parameters for single-energy CT (SECT) imaging were a tube voltage of 140 kVp, a tube current of 385 mA, a 0.5-second gantry revolution time, helical mode, and pitch of 1.375:1. The volume CT dose index (CTDI(vol)) value displayed on the console for each scan was recorded. Organ doses were measured using metal oxide semiconductor field-effect transistor technology. Effective dose was calculated as the sum of 20 organ doses multiplied by a weighting factor found in International Commission on Radiological Protection Publication 60. Radiation dose saving with virtual noncontrast imaging reconstruction was also determined. RESULTS: The CTDI(vol) values were 49.4 mGy for DECT imaging and 16.2 mGy for SECT imaging. Effective dose ranged from 22.5 to 36.4 mSv for DECT imaging and from 9.4 to 13.8 mSv for SECT imaging. Virtual noncontrast imaging reconstruction reduced the total effective dose of multiphase DECT imaging by 19% to 28%. CONCLUSION: Using the current Volume Dual Energy software, radiation doses with DECT imaging were higher than those with SECT imaging. Substantial radiation dose savings are possible with DECT imaging if virtual noncontrast imaging reconstruction replaces precontrast imaging.
Resumo:
We demonstrate a reliable microfabrication process for a combined atomic force microscopy (AFM) and scanning electrochemical microscopy (SECM) measurement tool. Integrated cone-shaped sensors with boron doped diamond (BDD) or gold (Au) electrodes were fabricated from commercially available AFM probes. The sensor formation process is based on mature semiconductor processing techniques, including focused ion beam (FIB) machining, and highly selective reactive ion etching (RIE). The fabrication approach preserves the geometry of the original AFM tips resulting in well reproducible nanoscaled sensors. The feasibility and functionality of the fully featured tips are demonstrated by cyclic voltammetry, showing good agreement between the measured and calculated currents of the cone-shaped AFM-SECM electrodes.