2 resultados para Mergulho scuba

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

10.00% 10.00%

Publicador:

Resumo:

An unusual case is presented of a tourist who developed fatal cerebral air embolism, pneumomediastinum and pneumopericardium while ascending from low altitude to Europe's highest railway station. Presumably the air embolism originated from rupture of the unsuspected bronchogenic cyst as a result of pressure changes during the ascent. Cerebral air embolism has been observed during surgery, in scuba diving accidents, submarine escapes and less frequently during exposure to very high altitude. People with known bronchogenic cysts should be informed about the risk of cerebral air embolism and surgical removal should be considered. Cerebral air embolism is a rare cause of coma and stroke in all activities with rapid air pressure changes, including alpine tourism, as our unfortunate tourist illustrates.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to test the hypothesis that ear oximetry immediately after the release of a sustained Valsalva maneuver accurately detects patent foramen ovale (PFO). One hundred sixty-five scuba divers underwent transesophageal echocardiography (TEE; reference method) for PFO assessment. Ear oximetry of the right earlobe was performed in a different room within a time frame of 2 hours before or after TEE. The subject and the oximetry operator were unaware of the results of TEE. Oxygen saturation (SO(2)) measurements were obtained at baseline and during the release phase of 4 Valsalva maneuvers within 10 minutes, and the average SO(2) change (SO(2) at baseline minus SO(2) at Valsalva release) was determined as the primary study end point. One hundred seventeen divers had no PFO, and 48 (29%) had PFO by TEE (mean age 39 ± 8 years). The average SO(2) change was 0.79 ± 1.13% (i.e., a slight absolute SO(2) decrease in response to the Valsalva maneuver) in the group without PFO and 1.67 ± 1.19% in the PFO group (p <0.0001). Using receiver-operating characteristic curve analysis, a PFO as defined by TEE could be detected at a threshold of a Valsalva-induced decrease in SO(2) of ≥0.825 percentage points in comparison to baseline (sensitivity 0.756, specificity 0.706, area under the receiver-operating characteristic curve 0.763, p <0.0001, negative predictive value 0.882). In conclusion, the entirely noninvasive method of ear oximetry in response to repetitive Valsalva maneuvers is accurate and useful as a screening method for the detection of a PFO, as shown in this study of divers.