This study investigated the excitability and accommodative properties of low-threshold human motor axons to test whether these motor axons have greater expression of the persistent Na(+) conductance, I(NaP). Computer-controlled threshold tracking was used to study 22 single motor units and the data were compared with compound motor potentials of various amplitudes recorded in the same experimental session. Detailed comparisons were made between the single units and compound potentials that were 40% or 5% of maximal amplitude, the former because this is the compound potential size used in most threshold tracking studies of axonal excitability, the latter because this is the compound potential most likely to be composed entirely of motor axons with low thresholds to electrical recruitment. Measurements were made of the strength-duration relationship, threshold electrotonus, current-voltage relationship, recovery cycle and latent addition. The findings did not support a difference in I(NaP). Instead they pointed to greater activity of the hyperpolarization-activated inwardly rectifying current (I(h)) as the basis for low threshold to electrical recruitment in human motor axons. Computer modelling confirmed this finding, with a doubling of the hyperpolarization-activated conductance proving the best single parameter adjustment to fit the experimental data. We suggest that the hyperpolarization-activated cyclic nucleotide-gated (HCN) channel(s) expressed on human motor axons may be active at rest and contribute to resting membrane potential.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Pericard 6 (P6) is one of the most frequently used acupuncture points, especially in preventing nausea and vomiting. At this point, the median nerve is located very superficially. OBJECTIVES: To investigate the distance between the needle tip and the median nerve during acupuncture at P6, we conducted a prospective observational ultrasound (US) imaging study. We tested the hypothesis that de qi (a sensation that is typical of acupuncture needling) is evoked when the needle comes into contact with the epineural tissue and thereby prevents nerve penetration. SETTINGS/LOCATION: The outpatient pain clinic of the Medical University of Vienna, Austria. SUBJECTS: Fifty (50) patients receiving acupuncture treatment including P6 bilaterally. INTERVENTIONS: Patients were examined at both forearms using US (a 10-MHz linear transducer) after insertion of the needle at P6. OUTCOME MEASURES: The distance between the needle tip and the median nerve, the number of nerve contacts and nerve penetrations, as well as the number of successfully elicited de qi sensations were recorded. RESULTS: Complete data could be obtained from 97 cases. The mean distance from the needle tip to the nerve was 1.8 mm (standard deviation 2.2; range 0-11.3). Nerve contacts were recorded in 52 cases, in 14 of which the nerve was penetrated by the needle. De qi was elicited in 85 cases. We found no association between the number of nerve contacts and de qi. The 1-week follow-up showed no complications or neurologic problems. CONCLUSIONS: This is the first investigation demonstrating the relationship between acupuncture needle placement and adjacent neural structures using US technology. The rate of median nerve penetrations by the acupuncture needle at P6 was surprisingly high, but these seemed to carry no risk of neurologic sequelae. De qi at P6 does not depend on median nerve contact, nor does it prevent median nerve penetration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In an experiment on one of the authors, we used ultrasound to visualise an acupuncture needle completely perforating the median nerve at the acupuncture point PC6. During this procedure only a slight sensation occurred, and no pain. We conclude that, in individual cases, the median nerve might be perforated without causing pain or neurological problems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

STATE OF THE ART The proximal median nerve compression syndrome includes the pronator teres and the Kiloh-Nevin syndrome. This article presents a new surgical technique of endoscopic assisted median nerve decompression. MATERIAL AND SURGICAL TECHNIQUE Endoscopic scissor decompression of the median nerve is always performed under plexus anaesthesia. It includes 6 key steps documented in this article. We review the indications and limitations of the surgical technique. RESULTS Since 2011, three clinical series have highlighted the advantages of this technique. Functional and subjective results are discussed. We also review the limitations of the technique and its potential for future development. CONCLUSION Although clinical results after endoscopic assisted decompression of the median nerve appear excellent they still need to be compared with conventional techniques. Clinical studies are likely to develop primarily due to the mini-invasive nature of this new surgical technique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE To investigate the feasibility of MR diffusion tensor imaging (DTI) of the median nerve using simultaneous multi-slice echo planar imaging (EPI) with blipped CAIPIRINHA. MATERIALS AND METHODS After federal ethics board approval, MR imaging of the median nerves of eight healthy volunteers (mean age, 29.4 years; range, 25-32) was performed at 3 T using a 16-channel hand/wrist coil. An EPI sequence (b-value, 1,000 s/mm(2); 20 gradient directions) was acquired without acceleration as well as with twofold and threefold slice acceleration. Fractional anisotropy (FA), mean diffusivity (MD) and quality of nerve tractography (number of tracks, average track length, track homogeneity, anatomical accuracy) were compared between the acquisitions using multivariate ANOVA and the Kruskal-Wallis test. RESULTS Acquisition time was 6:08 min for standard DTI, 3:38 min for twofold and 2:31 min for threefold acceleration. No differences were found regarding FA (standard DTI: 0.620 ± 0.058; twofold acceleration: 0.642 ± 0.058; threefold acceleration: 0.644 ± 0.061; p ≥ 0.217) and MD (standard DTI: 1.076 ± 0.080 mm(2)/s; twofold acceleration: 1.016 ± 0.123 mm(2)/s; threefold acceleration: 0.979 ± 0.153 mm(2)/s; p ≥ 0.074). Twofold acceleration yielded similar tractography quality compared to standard DTI (p > 0.05). With threefold acceleration, however, average track length and track homogeneity decreased (p = 0.004-0.021). CONCLUSION Accelerated DTI of the median nerve is feasible. Twofold acceleration yields similar results to standard DTI. KEY POINTS • Standard DTI of the median nerve is limited by its long acquisition time. • Simultaneous multi-slice acquisition is a new technique for accelerated DTI. • Accelerated DTI of the median nerve yields similar results to standard DTI.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose To compare changes in the largest cross-sectional area (CSA) of the median nerve in wrists undergoing surgical decompression with changes in wrists undergoing non-surgical treatment of carpal tunnel syndrome (CTS). Methods This study was a prospective cohort study in 55 consecutive patients with 78 wrists with established CTS, including 60 wrists treated with surgical decompression and 18 wrists with non-surgical treatment. A sonographic examination was scheduled before and 4 months after initiation of treatment. We compared changes in CSA of the median nerve between wrists with surgical treatment and wrists with non-surgical treatment using linear regression models. Results Decreases in CSA of the median nerve were more pronounced in wrists with CTS release than in wrists undergoing nonsurgical treatment (difference in means, 1.0 mm2; 95% confidence interval, 0.3–1.8 mm2). Results were robust to the adjustment for age, gender, and neurological severity at baseline. Among wrists with CTS release, those with postoperative CSA of 10 mm2 or less tended to have better clinical outcomes than those with postoperative CSA of greater than 10 mm2 (p=.055). Postoperative sonographic workup in the 3 patients with unfavorable outcome or recurrence identified likely causes for treatment failure in 2 patients. Conclusions In this observational study, surgical decompression was associated with a greater decrease in median nerve CSA than was nonsurgical treatment. Smaller postoperative CSAs may be associated with better clinical outcomes. Additional randomized trials are necessary to determine the optimal treatment strategy in different subgroups of patients with CTS. Type of study/level of evidence Therapeutic III.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

High-resolution ultrasound is becoming increasingly important in the diagnosis of carpal tunnel syndrome (CTS). Most studies define cut-off values of the cross-sectional area (CSA) of the median nerve in different locations. The individual range of nerve swelling, the size of the nerve, and its CSA are not addressed. The aim of the study is to define the intra- and interobserver reliability of diagnostic ultrasound using two different cross-sectional areas of the median nerve at the carpal tunnel in predefined locations.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Episodic ataxia type 1 is a neuronal channelopathy caused by mutations in the KCNA1 gene encoding the fast K(+) channel subunit K(v)1.1. Episodic ataxia type 1 presents with brief episodes of cerebellar dysfunction and persistent neuromyotonia and is associated with an increased incidence of epilepsy. In myelinated peripheral nerve, K(v)1.1 is highly expressed in the juxtaparanodal axon, where potassium channels limit the depolarizing afterpotential and the effects of depolarizing currents. Axonal excitability studies were performed on patients with genetically confirmed episodic ataxia type 1 to characterize the effects of K(v)1.1 dysfunction on motor axons in vivo. The median nerve was stimulated at the wrist and compound muscle action potentials were recorded from abductor pollicis brevis. Threshold tracking techniques were used to record strength-duration time constant, threshold electrotonus, current/threshold relationship and the recovery cycle. Recordings from 20 patients from eight kindreds with different KCNA1 point mutations were compared with those from 30 normal controls. All 20 patients had a history of episodic ataxia and 19 had neuromyotonia. All patients had similar, distinctive abnormalities: superexcitability was on average 100% higher in the patients than in controls (P < 0.00001) and, in threshold electrotonus, the increase in excitability due to a depolarizing current (20% of threshold) was 31% higher (P < 0.00001). Using these two parameters, the patients with episodic ataxia type 1 and controls could be clearly separated into two non-overlapping groups. Differences between the different KCNA1 mutations were not statistically significant. Studies of nerve excitability can identify K(v)1.1 dysfunction in patients with episodic ataxia type 1. The simple 15 min test may be useful in diagnosis, since it can differentiate patients with episodic ataxia type 1 from normal controls with high sensitivity and specificity.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Patients in intensive care units frequently suffer muscle weakness and atrophy due to critical illness polyneuropathy (CIP), an axonal neuropathy associated with systemic inflammatory response syndrome and multiple organ failure. CIP is a frequent and serious complication of intensive care that delays weaning from mechanical ventilation and increases mortality. The pathogenesis of CIP is not well understood and no specific therapy is available. The aim of this project was to use nerve excitability testing to investigate the changes in axonal membrane properties occurring in CIP. Ten patients (aged 37-76 years; 7 males, 3 females) were studied with electrophysiologically proven CIP. The median nerve was stimulated at the wrist and compound action potentials were recorded from abductor pollicis brevis muscle. Strength-duration time constant, threshold electrotonus, current-threshold relationship and recovery cycle (refractoriness, superexcitability and late subexcitability) were recorded using a recently described protocol. In eight patients a follow-up investigation was performed. All patients underwent clinical examination and laboratory investigations. Compared with age-matched normal controls (20 subjects; aged 38-79 years; 7 males, 13 females), CIP patients exhibited reduced superexcitability at 7 ms, from -22.3 +/- 1.6% to -7.6 +/- 3.1% (mean +/- SE, P approximately 0.0001) and increased accommodation to depolarizing (P < 0.01) and hyperpolarizing currents (P < 0.01), indicating membrane depolarization. Superexcitability was reduced both in patients with renal failure and without renal failure. In the former, superexcitability correlated with serum potassium (R = 0.88), and late subexcitability was also reduced (as also occurs owing to hyperkalaemia in patients with chronic renal failure). In patients without renal failure, late subexcitability was normal, and the signs of membrane depolarization correlated with raised serum bicarbonate and base excess, indicating compensated respiratory acidosis. It is inferred that motor axons in these CIP patients are depolarized, in part because of raised extracellular potassium, and in part because of hypoperfusion. The chronic membrane depolarization may contribute to the development of neuropathy.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND Besides carpal tunnel and cubital tunnel syndrome, other nerve compression or constriction syndromes exist at the upper extremity. This study was performed to evaluate and summarize our initial experience with endoscopically assisted decompression. MATERIALS AND METHODS Between January 2011 and March 2012, six patients were endoscopically operated for rare compression or hour-glass-like constriction syndrome. This included eight decompressions: four proximal radial nerve decompressions, and two combined proximal median nerve and anterior interosseus nerve decompressions. Surgical technique and functional outcomes are presented. RESULTS There were no intraoperative complications in the series. Endoscopy allowed both identifying and removing all the compressive structures. In one case, the proximal radial neuropathy developed for 10 years without therapy and a massive hour-glass nerve constriction was observed intraoperatively which led us to perform a concurrent complementary tendon transfer to improve fingers and thumb extension. Excellent results were achieved according to the modified Roles and Maudsley classification in five out of six cases. All but one patient considered the results excellent. The poorest responder developed a CRPS II and refused post-operative physiotherapy. CONCLUSION Endoscopically assisted decompression in rare compression syndrome of the upper extremity is highly appreciated by patients and provides excellent functional results. This minimally invasive surgical technique will likely be further described in future clinical studies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Our study group recently evaluated an ED(95) local anaesthetic volume of 0.11 ml.mm(-2) cross-sectional nerve area for the ulnar nerve. This prospective, randomised, double-blind crossover study investigated whether this volume is sufficient for brachial plexus blocks at the axillary level. Ten volunteers received an ultrasonographic guided axillary brachial plexus block either with 0.11 ('low' volume) or 0.4 ('high' volume) ml.mm(-2) cross-sectional nerve area with mepivacaine 1%. The mean (SD) volume was in the low volume group 4.0 (1.0) and 14.8 (3.8) ml in the high volume group. The success rate for the individual nerve blocks was 27 out of 30 in the low volume group (90%) and 30 out of 30 in the high volume group (100%), resulting in 8 out of 10 (80%) vs 10 out of 10 (100%) complete blocks in the low vs the high volume groups, respectively (NS). The mean (SD) sensory onset time was 25.0 (14.8) min in the low volume group and 15.8 (6.8) min in the high volume group (p < 0.01). The mean (SD) duration of sensory block was 125 (38) min in the low volume group and 152 (70) min in the high volume group (NS). This study confirms our previous published ED(95) volume for mepivacaine 1% to block peripheral nerves. The volume of local anaesthetic has some influence on the sensory onset time.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Electrical stimulation of the P6 acupuncture point reduces the incidence of postoperative nausea and vomiting (PONV). Neuromuscular blockade during general anesthesia can be monitored with electrical peripheral nerve stimulation at the wrist. The authors tested the effect of neuromuscular monitoring over the P6 acupuncture point on the reduction of PONV. METHODS: In this prospective, double-blinded, randomized control trial, the authors investigated, with institutional review board approval and informed consent, 220 women undergoing elective laparoscopic surgery anesthetized with fentanyl, sevoflurane, and rocuronium. During anesthesia, neuromuscular blockade was monitored by a conventional nerve stimulator at a frequency of 1 Hz over the ulnar nerve (n = 110, control group) or over the median nerve (n = 110, P6 group) stimulating at the P6 acupuncture point at the same time. The authors evaluated the incidence of nausea and vomiting during the first 24 h. RESULTS: No differences in demographic and morphometric data were found between both groups. The 24-h incidence of PONV was 45% in the P6 acupuncture group versus 61% in the control group (P = 0.022). Nausea decreased from 56% in the control group to 40% in the P6 group (P = 0.022), but emesis decreased only from 28% to 23% (P = 0.439). Nausea decreased substantially during the first 6 h of the observation period (P = 0.009). Fewer subjects in the acupuncture group required ondansetron as rescue therapy (27% vs. 39%; P = 0.086). CONCLUSION: Intraoperative P6 acupuncture point stimulation with a conventional nerve stimulator during surgery significantly reduced the incidence of PONV over 24 h. The efficacy of P6 stimulation is similar to that of commonly used antiemetic drugs in the prevention of PONV.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Planar electrodes are increasingly used in therapeutic neural stimulation techniques such as functional electrical stimulation, epidural spinal cord stimulation (ESCS), and cortical stimulation. Recently, optimized electrode geometries have been shown to increase the efficiency of neural stimulation by increasing the variation of current density on the electrode surface. In the present work, a new family of modified fractal electrode geometries is developed to enhance the efficiency of neural stimulation. It is shown that a promising approach in increasing the neural activation function is to increase the "edginess" of the electrode surface, a concept that is explained and quantified by fractal mathematics. Rigorous finite element simulations were performed to compute electric potential produced by proposed modified fractal geometries. The activation of 256 model axons positioned around the electrodes was then quantified, showing that modified fractal geometries required a 22% less input power while maintaining the same level of neural activation. Preliminary in vivo experiments investigating muscle evoked potentials due to median nerve stimulation showed encouraging results, supporting the feasibility of increasing neural stimulation efficiency using modified fractal geometries.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Chronic neck pain after whiplash injury is caused by cervical zygapophysial joints in 50% of patients. Diagnostic blocks of nerves supplying the joints are performed using fluoroscopy. The authors' hypothesis was that the third occipital nerve can be visualized and blocked with use of an ultrasound-guided technique. METHODS: In 14 volunteers, the authors placed a needle ultrasound-guided to the third occipital nerve on both sides of the neck. They punctured caudal and perpendicular to the 14-MHz transducer. In 11 volunteers, 0.9 ml of either local anesthetic or normal saline was applied in a randomized, double-blind, crossover manner. Anesthesia was controlled in the corresponding skin area by pinprick and cold testing. The position of the needle was controlled by fluoroscopy. RESULTS: The third occipital nerve could be visualized in all subjects and showed a median diameter of 2.0 mm. Anesthesia was missing after local anesthetic in only one case. There was neither anesthesia nor hyposensitivity after any of the saline injections. The C2-C3 joint, in a transversal plane visualized as a convex density, was identified correctly by ultrasound in 27 of 28 cases, and 23 needles were placed correctly into the target zone. CONCLUSIONS: The third occipital nerve can be visualized and blocked with use of an ultrasound-guided technique. The needles were positioned accurately in 82% of cases as confirmed by fluoroscopy; the nerve was blocked in 90% of cases. Because ultrasound is the only available technique today to visualize this nerve, it seems to be a promising new method for block guidance instead of fluoroscopy.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose The sedimentation sign (SedSign) has been shown to discriminate well between selected patients with and without lumbar spinal stenosis (LSS). The purpose of this study was to compare the pressure values associated with LSS versus non-LSS and discuss whether a positive SedSign may be related to increased epidural pressure at the level of the stenosis. Methods We measured the intraoperative epidural pressure in five patients without LSS and a negative SedSign, and in five patients with LSS and a positive SedSign using a Codman TM catheter in prone position under radioscopy. Results Patients with a negative SedSign had a median epidural pressure of 9 mmHg independent of the measurement location. Breath and pulse-synchronous waves accounted for 1–3 mmHg. In patients with monosegmental LSS and a positive SedSign, the epidural pressure above and below the stenosis was similar (median 8–9 mmHg). At the level of the stenosis the median epidural pressure was 22 mmHg. A breath and pulse-synchronous wave was present cranial to the stenosis, but absent below. These findings were independent of the cross-sectional area of the spinal canal at the level of the stenosis. Conclusions Patients with LSS have an increased epidural pressure at the level of the stenosis and altered pressure wave characteristics below. We argue that the absence of sedimentation of lumbar nerve roots to the dorsal part of the dural sac in supine position may be due to tethering of affected nerve roots at the level of the stenosis.