12 resultados para Measurement-While-Drilling

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Rare event search experiments using liquid xenon as target and detection medium require ultra-low background levels to fully exploit their physics potential. Cosmic ray induced activation of the detector components and, even more importantly, of the xenon itself during production, transportation and storage at the Earth's surface, might result in the production of radioactive isotopes with long half-lives, with a possible impact on the expected background. We present the first dedicated study on the cosmogenic activation of xenon after 345 days of exposure to cosmic rays at the Jungfraujoch research station at 3470m above sea level, complemented by a study of copper which has been activated simultaneously. We have directly observed the production of 7Be, 101Rh, 125Sb, 126I and 127Xe in xenon, out of which only 125Sb could potentially lead to background for a multi-ton scale dark matter search. The production rates for five out of eight studied radioactive isotopes in copper are in agreement with the only existing dedicated activation measurement, while we observe lower rates for the remaining ones. The specific saturation activities for both samples are also compared to predictions obtained with commonly used software packages, where we observe some underpredictions, especially for xenon activation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study deals with the determination of the retentive force between primary and secondary telescopic crowns under clinical conditions. Forty-three combined fixed-removable prostheses with a total of 140 double crowns were used for retention force measurement of the telescopic crowns prior to cementation. The crowns had a preparation of 1-2°. A specifically designed measuring device was used. The retentive forces were measured with and without lubrication by a saliva substitute. The measured values were analyzed according to the type of tooth (incisors, canines, premolars, and molars). Additionally, a comparison between lubricated and unlubricated telescopic crowns was done. As maximum retention force value 29.98 N was recorded with a telescopic crown on a molar, while the minimum of 0.08 N was found with a specimen on a canine. The median value of retention force of all telescopic crowns reached 1.93 N with an interquartile distance of 4.35 N. No statistically significant difference between lubricated and unlubricated specimens was found. The results indicate that retention force values of telescopic crowns, measured in clinical practice, are often much lower than those cited in the literature. The measurements also show a wide range. Whether this proves to be a problem for the patient's quality of life or not can however only be established by a comparison of the presented results with a follow-up study involving measurement of intraoral retention and determination by e.g. oral health impact profile.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction Electrical impedance tomography (EIT) has been shown to be able to distinguish both ventilation and perfusion. With adequate filtering the regional distributions of both ventilation and perfusion and their relationships could be analysed. Several methods of separation have been suggested previously, including breath holding, electrocardiograph (ECG) gating and frequency filtering. Many of these methods require interventions inappropriate in a clinical setting. This study therefore aims to extend a previously reported frequency filtering technique to a spontaneously breathing cohort and assess the regional distributions of ventilation and perfusion and their relationship. Methods Ten healthy adults were measured during a breath hold and while spontaneously breathing in supine, prone, left and right lateral positions. EIT data were analysed with and without filtering at the respiratory and heart rate. Profiles of ventilation, perfusion and ventilation/perfusion related impedance change were generated and regions of ventilation and pulmonary perfusion were identified and compared. Results Analysis of the filtration technique demonstrated its ability to separate the ventilation and cardiac related impedance signals without negative impact. It was, therefore, deemed suitable for use in this spontaneously breathing cohort. Regional distributions of ventilation, perfusion and the combined ΔZV/ΔZQ were calculated along the gravity axis and anatomically in each position. Along the gravity axis, gravity dependence was seen only in the lateral positions in ventilation distribution, with the dependent lung being better ventilated regardless of position. This gravity dependence was not seen in perfusion. When looking anatomically, differences were only apparent in the lateral positions. The lateral position ventilation distributions showed a difference in the left lung, with the right lung maintaining a similar distribution in both lateral positions. This is likely caused by more pronounced anatomical changes in the left lung when changing positions. Conclusions The modified filtration technique was demonstrated to be effective in separating the ventilation and perfusion signals in spontaneously breathing subjects. Gravity dependence was seen only in ventilation distribution in the left lung in lateral positions, suggesting gravity based shifts in anatomical structures. Gravity dependence was not seen in any perfusion distributions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: To evaluate whether or not preparation of the implant site with osteotomes instead of drilling may improve peri-implant bone density and/or osseointegration, and whether or not this further improves the predictability of immediate loading of SLA implants. MATERIAL AND METHODS: The second, third, and fourth premolars were extracted in both sides of the mandible in six dogs, and after at least 3 months four SLA implants were inserted into each side of the jaw. In three animals, the implant sites were prepared by means of osteotomes, while standard stepwise drilling was used in the remaining animals. In each side of the jaw, two non-adjacent implants were restored with single crowns 4 days after installation, while the remaining two implants were left without crowns to serve as non-loaded controls. After 2, 4, or 12 weeks of loading, specimens including the implants and surrounding tissues were obtained and processed for histologic analysis of undecalcified sections. RESULTS: All implants placed with osteotomes were lost (five before delivery of the crowns and the rest during the first week after loading). None of the conventionally inserted implants, however, was lost, and histomorphometrical analysis revealed similar soft- and hard peri-implant tissue characteristics at immediately loaded and non-loaded implants at all observation times. Average bone-to-implant contact was 59-72% at immediately loaded implants vs. 60-63% at non-loaded ones. CONCLUSION: Preparation of the implant site by means of osteotomes had a deleterious effect on osseointegration, while immediate loading of single, free-standing, SLA implants following a conventional surgical protocol did not jeopardize their osseointegration.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Bleeding is a frequent complication during surgery. The intraoperative administration of blood products, including packed red blood cells, platelets and fresh frozen plasma (FFP), is often live saving. Complications of blood transfusions contribute considerably to perioperative costs and blood product resources are limited. Consequently, strategies to optimize the decision to transfuse are needed. Bleeding during surgery is a dynamic process and may result in major blood loss and coagulopathy due to dilution and consumption. The indication for transfusion should be based on reliable coagulation studies. While hemoglobin levels and platelet counts are available within 15 minutes, standard coagulation studies require one hour. Therefore, the decision to administer FFP has to be made in the absence of any data. Point of care testing of prothrombin time ensures that one major parameter of coagulation is available in the operation theatre within minutes. It is fast, easy to perform, inexpensive and may enable physicians to rationally determine the need for FFP. METHODS/DESIGN: The objective of the POC-OP trial is to determine the effectiveness of point of care prothrombin time testing to reduce the administration of FFP. It is a patient and assessor blind, single center randomized controlled parallel group trial in 220 patients aged between 18 and 90 years undergoing major surgery (any type, except cardiac surgery and liver transplantation) with an estimated blood loss during surgery exceeding 20% of the calculated total blood volume or a requirement of FFP according to the judgment of the physicians in charge. Patients are randomized to usual care plus point of care prothrombin time testing or usual care alone without point of care testing. The primary outcome is the relative risk to receive any FFP perioperatively. The inclusion of 110 patients per group will yield more than 80% power to detect a clinically relevant relative risk of 0.60 to receive FFP of the experimental as compared with the control group. DISCUSSION: Point of care prothrombin time testing in the operation theatre may reduce the administration of FFP considerably, which in turn may decrease costs and complications usually associated with the administration of blood products. TRIAL REGISTRATION: NCT00656396.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The application of image-guided systems with or without support by surgical robots relies on the accuracy of the navigation process, including patient-to-image registration. The surgeon must carry out the procedure based on the information provided by the navigation system, usually without being able to verify its correctness beyond visual inspection. Misleading surrogate parameters such as the fiducial registration error are often used to describe the success of the registration process, while a lack of methods describing the effects of navigation errors, such as those caused by tracking or calibration, may prevent the application of image guidance in certain accuracy-critical interventions. During minimally invasive mastoidectomy for cochlear implantation, a direct tunnel is drilled from the outside of the mastoid to a target on the cochlea based on registration using landmarks solely on the surface of the skull. Using this methodology, it is impossible to detect if the drill is advancing in the correct direction and that injury of the facial nerve will be avoided. To overcome this problem, a tool localization method based on drilling process information is proposed. The algorithm estimates the pose of a robot-guided surgical tool during a drilling task based on the correlation of the observed axial drilling force and the heterogeneous bone density in the mastoid extracted from 3-D image data. We present here one possible implementation of this method tested on ten tunnels drilled into three human cadaver specimens where an average tool localization accuracy of 0.29 mm was observed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Molybdenum isotopes are increasingly widely applied in Earth Sciences. They are primarily used to investigate the oxygenation of Earth's ocean and atmosphere. However, more and more fields of application are being developed, such as magmatic and hydrothermal processes, planetary sciences or the tracking of environmental pollution. Here, we present a proposal for a unifying presentation of Mo isotope ratios in the studies of mass-dependent isotope fractionation. We suggest that the δ98/95Mo of the NIST SRM 3134 be defined as +0.25‰. The rationale is that the vast majority of published data are presented relative to reference materials that are similar, but not identical, and that are all slightly lighter than NIST SRM 3134. Our proposed data presentation allows a direct first-order comparison of almost all old data with future work while referring to an international measurement standard. In particular, canonical δ98/95Mo values such as +2.3‰ for seawater and −0.7‰ for marine Fe–Mn precipitates can be kept for discussion. As recent publications show that the ocean molybdenum isotope signature is homogeneous, the IAPSO ocean water standard or any other open ocean water sample is suggested as a secondary measurement standard, with a defined δ98/95Mo value of +2.34 ± 0.10‰ (2s). Les isotopes du molybdène (Mo) sont de plus en plus largement utilisés dans les sciences de la Terre. Ils sont principalement utilisés pour étudier l'oxygénation de l'océan et de l'atmosphère de la Terre. Cependant, de plus en plus de domaines d'application sont en cours de développement, tels que ceux concernant les processus magmatiques et hydrothermaux, les sciences planétaires ou encore le suivi de la pollution environnementale. Ici, nous présentons une proposition de présentation unifiée des rapports isotopiques du Mo dans les études du fractionnement isotopique dépendant de la masse. Nous suggérons que le δ98/95Mo du NIST SRM 3134 soit définit comme étant égal à +0.25 ‰. La raison est que la grande majorité des données publiées sont présentés par rapport à des matériaux de référence qui sont similaires, mais pas identiques, et qui sont tous légèrement plus léger que le NIST SRM 3134. Notre proposition de présentation des données permet une comparaison directe au premier ordre de presque toutes les anciennes données avec les travaux futurs en se référant à un standard international. En particulier, les valeurs canoniques du δ98/95Mo comme celle de +2,3 ‰ pour l'eau de mer et de -0,7 ‰ pour les précipités de Fe-Mn marins peuvent être conservés pour la discussion. Comme les publications récentes montrent que la signature isotopique moyenne du molybdène de l'océan est homogène, le standard de l'eau océanique IAPSO ou tout autre échantillon d'eau provenant de l'océan ouvert sont proposé comme standards secondaires, avec une valeur définie du δ98/95 Mo de 2.34 ± 0.10 ‰ (2s).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Instruments for on-farm determination of colostrum quality such as refractometers and densimeters are increasingly used in dairy farms. The colour of colostrum is also supposed to reflect its quality. A paler or mature milk-like colour is associated with a lower colostrum value in terms of its general composition compared with a more yellowish and darker colour. The objective of this study was to investigate the relationships between colour measurement of colostrum using the CIELAB colour space (CIE L*=from white to black, a*=from red to green, b*=from yellow to blue, chroma value G=visual perceived colourfulness) and its composition. Dairy cow colostrum samples (n=117) obtained at 4·7±1·5 h after parturition were analysed for immunoglobulin G (IgG) by ELISA and for fat, protein and lactose by infrared spectroscopy. For colour measurements, a calibrated spectrophotometer was used. At a cut-off value of 50 mg IgG/ml, colour measurement had a sensitivity of 50·0%, a specificity of 49·5%, and a negative predictive value of 87·9%. Colostral IgG concentration was not correlated with the chroma value G, but with relative lightness L*. While milk fat content showed a relationship to the parameters L*, a*, b* and G from the colour measurement, milk protein content was not correlated with a*, but with L*, b*, and G. Lactose concentration in colostrum showed only a relationship with b* and G. In conclusion, parameters of the colour measurement showed clear relationships to colostral IgG, fat, protein and lactose concentration in dairy cows. Implementation of colour measuring devices in automatic milking systems and milking parlours might be a potential instrument to access colostrum quality as well as detecting abnormal milk.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

ATLAS measurements of the azimuthal anisotropy in lead–lead collisions at √sNN = 2.76 TeV are shown using a dataset of approximately 7μb−1 collected at the LHC in 2010. The measurements are performed for charged particles with transversemomenta 0.5 < pT < 20 GeV and in the pseudorapidity range |η| < 2.5. The anisotropy is characterized by the Fourier coefficients, vn, of the charged-particle azimuthal angle distribution for n = 2–4. The Fourier coefficients are evaluated using multi-particle cumulants calculated with the generating function method. Results on the transverse momentum, pseudorapidity and centrality dependence of the vn coefficients are presented. The elliptic flow, v2, is obtained from the two-, four-, six- and eight-particle cumulants while higher-order coefficients, v3 and v4, are determined with two- and four-particle cumulants. Flow harmonics vn measured with four-particle cumulants are significantly reduced compared to the measurement involving two-particle cumulants. A comparison to vn measurements obtained using different analysis methods and previously reported by the LHC experiments is also shown. Results of measurements of flow fluctuations evaluated with multiparticle cumulants are shown as a function of transverse momentum and the collision centrality. Models of the initial spatial geometry and its fluctuations fail to describe the flow fluctuations measurements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A detailed characterization of air quality in the megacity of Paris (France) during two 1-month intensive campaigns and from additional 1-year observations revealed that about 70% of the urban background fine particulate matter (PM) is transported on average into the megacity from upwind regions. This dominant influence of regional sources was confirmed by in situ measurements during short intensive and longer-term campaigns, aerosol optical depth (AOD) measurements from ENVISAT, and modeling results from PMCAMx and CHIMERE chemistry transport models. While advection of sulfate is well documented for other megacities, there was surprisingly high contribution from long-range transport for both nitrate and organic aerosol. The origin of organic PM was investigated by comprehensive analysis of aerosol mass spectrometer (AMS), radiocarbon and tracer measurements during two intensive campaigns. Primary fossil fuel combustion emissions constituted less than 20%in winter and 40%in summer of carbonaceous fine PM, unexpectedly small for a megacity. Cooking activities and, during winter, residential wood burning are the major primary organic PM sources. This analysis suggests that the major part of secondary organic aerosol is of modern origin, i.e., from biogenic precursors and from wood burning. Black carbon concentrations are on the lower end of values encountered in megacities worldwide, but still represent an issue for air quality. These comparatively low air pollution levels are due to a combination of low emissions per inhabitant, flat terrain, and a meteorology that is in general not conducive to local pollution build-up. This revised picture of a megacity only being partially responsible for its own average and peak PM levels has important implications for air pollution regulation policies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

REASONS FOR PERFORMING STUDY: The diagnosis of equine back disorders is challenging. Objectively determining movement of the vertebral column may therefore be of value in a clinical setting. OBJECTIVES: To establish whether surface-mounted inertial measurement units (IMUs) can be used to establish normal values for range of motion (ROM) of the vertebral column in a uniform population of horses trotting under different conditions. STUDY DESIGN: Vertebral ROM was established in Franches-Montagnes stallions and a general population of horses and the variability in measurements compared between the two groups. Repeatability and the influence of specific exercise condition (on ROM) were assessed. Finally, attempts were made to explain the findings of the study through the evaluation of factors that might influence ROM. METHODS: Dorsoventral (DV) and mediolateral (ML) vertebral ROM was measured at a trot under different exercise conditions in 27 Franches-Montagnes stallions and six general population horses using IMUs distributed over the vertebral column. RESULTS: Variability in the ROM measurements was significantly higher for general population horses than for Franches-Montagnes stallions (both DV and ML ROM). Repeatability was strong to very strong for DV measurements and moderate for ML measurements. Trotting under saddle significantly reduced the ROM, with sitting trot resulting in a significantly lower ROM than rising trot. Age is unlikely to explain the low variability in vertebral ROM recorded in the Franches-Montagnes horses, while this may be associated with conformational factors. CONCLUSIONS: It was possible to establish a normal vertebral ROM for a group of Franches-Montagnes stallions. While within-breed variation was low in this population, further studies are necessary to determine variation in vertebral ROM for other breeds and to assess their utility for diagnosis of equine back disorders.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Rockfall protection barriers are connected to the ground using steel cables fixed with anchors and foundations for the steel posts. It is common practice to measure the forces in the cables, while to date measurements of forces in the foundations have been inadequately resolved. An overview is presented of existing methods to measure the loads on the post foundations of rockfall protection barriers. Addressing some of the inadequacies of existing approaches, a novel sensor unit is presented that is able to capture the forces acting on post foundations in all six degrees of freedom. The sensor unit consists of four triaxial force sensors placed between two steel plates. To correctly convert the measurements into the directional forces acting on the foundation a special in-situ calibration procedure is proposed that delivers a corresponding conversion matrix.