10 resultados para Measurement instruments
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Systematic reviews and meta-analyses of randomized trials that include patient-reported outcomes (PROs) often provide crucial information for patients, clinicians and policy-makers facing challenging health care decisions. Based on emerging methods, guidance on improving the interpretability of meta-analysis of patient-reported outcomes, typically continuous in nature, is likely to enhance decision-making. The objective of this paper is to summarize approaches to enhancing the interpretability of pooled estimates of PROs in meta-analyses. When differences in PROs between groups are statistically significant, decision-makers must be able to interpret the magnitude of effect. This is challenging when, as is often the case, clinical trial investigators use different measurement instruments for the same construct within and between individual randomized trials. For such cases, in addition to pooling results as a standardized mean difference, we recommend that systematic review authors use other methods to present results such as relative (relative risk, odds ratio) or absolute (risk difference) dichotomized treatment effects, complimented by presentation in either: natural units (e.g. overall depression reduced by 2.4 points when measured on a 50-point Hamilton Rating Scale for Depression); minimal important difference units (e.g. where 1.0 unit represents the smallest difference in depression that patients, on average, perceive as important the depression score was 0.38 (95%CI 0.30 to 0.47) units less than the control group); or a ratio of means (e.g. where the mean in the treatment group is divided by the mean in the control group, the ratio of means is 1.27, representing a 27%relative reduction in the mean depression score).
Resumo:
Research into information quality on the internet, in particular on websites, has become increasingly important in recent years. In this paper a research project is described in which a measurement instrument was developed that enables the information quality of websites to be determined and analyzed from the customer perspective. The measurement instrument was developed in several stages and on the basis of a methodical-theoretical approach. In a first step, previous research results and measurement instruments were systematically analyzed. In a second step, these results were adjusted and supplemented on the basis of a qualitative study. A quantitative test of the measurement instrument is planned.
Resumo:
OBJECTIVE Although protocol registration for systematic reviews is still not mandatory, reviewers should be strongly encouraged to register the protocol to identify the methodological approach, including all outcomes of interest. This will minimize the likelihood of biased decisions in reviews, such as selective outcome reporting. A group of international experts convened to address issues regarding the need to develop hierarchical lists of outcome measurement instruments for a particular outcome for metaanalyses. METHODS Multiple outcome measurement instruments exist to measure the same outcome. Metaanalysis of knee osteoarthritis (OA) trials, and the assessment of pain as an outcome, was used as an exemplar to assess how Outcome Measures in Rheumatology (OMERACT), the Cochrane Collaboration, and other international initiatives might contribute in this area. The meeting began with formal presentations of background topics, empirical evidence from the literature, and a brief introduction to 2 existing hierarchical lists of pain outcome measurement instruments recommended for metaanalyses of knee OA trials. RESULTS After discussions, most participants agreed that there is a need to develop a methodology for generation of hierarchical lists of outcome measurement instruments to guide metaanalyses. Tools that could be used to steer development of such a prioritized list are the COSMIN checklist (Consensus-based Standards for the selection of health status Measurement Instruments) and the OMERACT Filter 2.0. CONCLUSION We list meta-epidemiological research agenda items that address the frequency of reported outcomes in trials, as well as methodologies to assess the best measurement properties (i.e., truth, discrimination, and feasibility).
Resumo:
BACKGROUND: Worldwide, diarrheal diseases rank second among conditions that afflict children. Despite the disease burden, there is limited consensus on how to define and measure pediatric acute diarrhea in trials. OBJECTIVES: In RCTs of children involving acute diarrhea as the primary outcome, we documented (1) how acute diarrhea and its resolution were defined, (2) all primary outcomes, (3) the psychometric properties of instruments used to measure acute diarrhea and (4) the methodologic quality of included trials, as reported. METHODS: We searched CENTRAL, Embase, Global Health, and Medline from inception to February 2009. English-language RCTs of children younger than 19 years that measured acute diarrhea as a primary outcome were chosen. RESULTS: We identified 138 RCTs reporting on 1 or more primary outcomes related to pediatric acute diarrhea/diseases. Included trials used 64 unique definitions of diarrhea, 69 unique definitions of diarrhea resolution, and 46 unique primary outcomes. The majority of included trials evaluated short-term clinical disease activity (incidence and duration of diarrhea), laboratory outcomes, or a composite of these end points. Thirty-two trials used instruments (eg, single and multidomain scoring systems) to support assessment of disease activity. Of these, 3 trials stated that their instrument was valid; however, none of the trials (or their citations) reported evidence of this validity. The overall methodologic quality of included trials was good. CONCLUSIONS: Even in what would be considered methodologically sound clinical trials, definitions of diarrhea, primary outcomes, and instruments employed in RCTs of pediatric acute diarrhea are heterogeneous, lack evidence of validity, and focus on indices that may not be important to participants.
Resumo:
In this paper a new 22 GHz water vapor spectro-radiometer which has been specifically designed for profile measurement campaigns of the middle atmosphere is presented. The instrument is of a compact design and has a simple set up procedure. It can be operated as a standalone instrument as it maintains its own weather station and a calibration scheme that does not rely on other instruments or the use of liquid nitrogen. The optical system of MIAWARA-C combines a choked gaussian horn antenna with a parabolic mirror which reduces the size of the instrument in comparison with currently existing radiometers. For the data acquisition a correlation receiver is used together with a digital cross correlating spectrometer. The complete backend section, including the computer, is located in the same housing as the instrument. The receiver section is temperature stabilized to minimize gain fluctuations. Calibration of the instrument is achieved through a balancing scheme with the sky used as the cold load and the tropospheric properties are determined by performing regular tipping curves. Since MIAWARA-C is used in measurement campaigns it is important to be able to determine the elevation pointing in a simple manner as this is a crucial parameter in the calibration process. Here we present two different methods; scanning the sky and the Sun. Finally, we report on the first spectra and retrieved water vapor profiles acquired during the Lapbiat campaign at the Finnish Meteorological Institute Arctic Research Centre in Sodankylä, Finland. The performance of MIAWARA-C is validated here by comparison of the presented profiles against the equivalent profiles from the Microwave Limb Sounder on the EOS/Aura satellite.
Resumo:
Methodological approaches in which data on nonverbal behavior are collected usually involve interpretive methods in which raters must identify a set of defined categories of behavior. However, present knowledge about the qualitative aspects of head movement behavior calls for recording detailed transcriptions of behavior. These records are a prerequisite for investigating the function and meaning of head movement patterns. A method for directly collecting data on head movement behavior is introduced. Using small ultrasonic transducers, which are attached to various parts of an index person's body (head and shoulders), a microcomputer defines receiver-transducers distances. Three-dimensional positions are calculated by triangulation. These data are used for further calculations concerning the angular orientation of the head and the direction, size, and speed of head movements (in rotational, lateral, and sagittal dimensions).
Resumo:
Instruments for on-farm determination of colostrum quality such as refractometers and densimeters are increasingly used in dairy farms. The colour of colostrum is also supposed to reflect its quality. A paler or mature milk-like colour is associated with a lower colostrum value in terms of its general composition compared with a more yellowish and darker colour. The objective of this study was to investigate the relationships between colour measurement of colostrum using the CIELAB colour space (CIE L*=from white to black, a*=from red to green, b*=from yellow to blue, chroma value G=visual perceived colourfulness) and its composition. Dairy cow colostrum samples (n=117) obtained at 4·7±1·5 h after parturition were analysed for immunoglobulin G (IgG) by ELISA and for fat, protein and lactose by infrared spectroscopy. For colour measurements, a calibrated spectrophotometer was used. At a cut-off value of 50 mg IgG/ml, colour measurement had a sensitivity of 50·0%, a specificity of 49·5%, and a negative predictive value of 87·9%. Colostral IgG concentration was not correlated with the chroma value G, but with relative lightness L*. While milk fat content showed a relationship to the parameters L*, a*, b* and G from the colour measurement, milk protein content was not correlated with a*, but with L*, b*, and G. Lactose concentration in colostrum showed only a relationship with b* and G. In conclusion, parameters of the colour measurement showed clear relationships to colostral IgG, fat, protein and lactose concentration in dairy cows. Implementation of colour measuring devices in automatic milking systems and milking parlours might be a potential instrument to access colostrum quality as well as detecting abnormal milk.
Resumo:
A fast and automatic method for radiocarbon analysis of aerosol samples is presented. This type of analysis requires high number of sample measurements of low carbon masses, but accepts precisions lower than for carbon dating analysis. The method is based on online Trapping CO2 and coupling an elemental analyzer with a MICADAS AMS by means of a gas interface. It gives similar results to a previously validated reference method for the same set of samples. This method is fast and automatic and typically provides uncertainties of 1.5–5% for representative aerosol samples. It proves to be robust and reliable and allows for overnight and unattended measurements. A constant and cross contamination correction is included, which indicates a constant contamination of 1.4 ± 0.2 μg C with 70 ± 7 pMC and a cross contamination of (0.2 ± 0.1)% from the previous sample. A Real-time online coupling version of the method was also investigated. It shows promising results for standard materials with slightly higher uncertainties than the Trapping online approach.
Resumo:
We introduce a new fiber-optical approach for reflection based refractive index mapping. Our approach leads to improved stability and reliability over existing free-space confocal instruments and significantly cuts alignment efforts and reduces the number of components needed. Other than properly cleaved fiber end-faces, this setup requires no additional sample preparation. The instrument is calibrated by means of a set of samples with known refractive indices. The index steps of commercially available fibers are measured accurately down to < 10⁻³. The precision limit of the instrument is currently of the order of 10⁻⁴.