17 resultados para Maximum plantar pressure
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
An epidural puncture was performed using the lumbosacral approach in 18 dogs, and the lack of resistance to an injection of saline was used to determine that the needle was positioned correctly. The dogs' arterial blood pressure and epidural pressure were recorded. They were randomly assigned to two groups: in one group an injection of a mixture of local anaesthetic agents was made slowly over 90 seconds and in the other it was made over 30 seconds. After 10 minutes contrast radiography was used to confirm the correct placement of the needle. The mean (sd) initial pressure in the epidural space was 0.1 (0.7) kPa. After the injection the mean maximum epidural pressure in the group injected slowly was 5.5 (2.1) kPa and in the group injected more quickly it was 6.0 (1.9) kPa. At the end of the period of measurement, the epidural pressure in the slow group was 0.8 (0.5) kPa and in the rapid group it was 0.7 (0.5) kPa. Waves synchronous with the arterial pulse wave were observed in 15 of the dogs before the epidural injection, and in all the dogs after the epidural injection.
Resumo:
PURPOSE: We assessed the effect of terazosin (Hytrin(R)) on functional bladder outlet obstruction in women. MATERIALS AND METHODS: Functional bladder outlet obstruction was defined as a maximum flow rate of less than 12 ml per second combined with a detrusor pressure at maximum flow rate of more than 20 cm H2O in pressure flow studies in the absence of neurological disorders or mechanical causes. In a prospective pilot study 15 women with functional bladder outlet obstruction were treated with terazosin. Terazosin was initiated at 1 mg daily and gradually increased to the maintenance dose of 5 mg daily during 2 weeks. Symptoms and urodynamic parameters were assessed before and 3 to 4 weeks after the initiation of alpha-blocker therapy. RESULTS: While on terazosin, voiding symptoms subjectively improved greater than 50% in 10 of the 15 women (p = 0.002). Median maximum urethral closure pressure at rest decreased significantly from 98 to 70 cm H2O (p = 0.001), median maximum detrusor pressure decreased from 45 to 35 cm H2O (p = 0.008), median detrusor pressure at maximum flow decreased from 34 to 27 ml per second and median post-void residual urine decreased from 120 to 40 ml (p = 0.006 and 0.002, respectively). There was a significant increase in the median maximum flow rate from 9 to 20 ml per second and in median voided volume from 300 to 340 ml (p = 0.0005 and 0.021, respectively). Storage symptoms, functional urethral length and maximum cystometric capacity did not change significantly with alpha-blocker therapy (p > 0.05). Overall terazosin resulted in a significant improvement in symptoms and urodynamic parameters in 10 of the 15 women (67%). CONCLUSIONS: Terazosin had a significant symptomatic and urodynamic effect in two-thirds of our patients. These results suggest that terazosin may be an effective treatment option in women with voiding dysfunction due to functional bladder outlet obstruction.
Resumo:
The meteorological circumstances that led to the Blizzard of March 1888 that hit New York are analysed in Version 2 of the “Twentieth Century Reanalysis” (20CR). The potential of this data set for studying historical extreme events has not yet been fully explored. A detailed analysis of 20CR data alongside other data sources (including historical instrumental data and weather maps) for historical extremes such as the March 1888 blizzard may give insights into the limitations of 20CR. We find that 20CR reproduces the circulation pattern as well as the temperature development very well. Regarding the absolute values of variables such as snow fall or minimum and maximum surface pressure, there is anunderestimation of the observed extremes, which may be due to the low spatial resolution of 20CR and the fact that only the ensemble mean is considered. Despite this drawback, the dataset allows us to gain new information due to its complete spatial and temporal coverage.
Resumo:
OBJECTIVES Pelvic floor rehabilitation is the conservative therapy of choice for women with stress urinary incontinence (SUI). The success rate of surgical procedures in SUI patients with intrinsic sphincter deficiency (ISD) is low. The aim of this study was to analyse the effect of a standardized physiotherapy on patients with SUI and normotonic urethra and ISD. METHODS In this study, 64 patients with ISD and 69 patients with normotonic urethra were enrolled. Maximum urethral pressure (MUCP) >20 cm H2 O was considered as normotonic urethral pressure. Before and after physiotherapy MUCP was measured and cough testing was performed. Additionally, patient reported outcome was assessed using the King's Health Questionnaire (KHQ). For statistical analyses Excel 2010 (Microsoft Inc; Redmond, Washington) and SPSS 20 (SPSS Inc; Chicago, Illinois) for Windows were used. Power calculation was based on the primary endpoint incontinence impact and general health. For power calculation, GraphPad Statmate version 2.00 for Windows was used. RESULTS Sixty-four patients with ISD and 69 patients with normotonic urethra were included in the study. In SUI patients with normotonic and hypotonic urethra KHQ-scores regarding the primary endpoins "general health" and "incontinence impact" significantly improved following standardized physiotherapy. In both groups MUCP increased after physiotherapy. In SUI patients with ISD standardized physiotherapy resulted in a decreased incidence of a positive cough test. CONCLUSIONS Standardized physiotherapy should be offered to patients with SUI and ISD. Long-term results are subject to future studies. Neurourol. Urodynam. © 2015 Wiley Periodicals, Inc.
Resumo:
CONTEXT Tibial nerve stimulation (TNS) is a promising therapy for non-neurogenic lower urinary tract dysfunction and might also be a valuable option for patients with an underlying neurological disorder. OBJECTIVE We systematically reviewed all available evidence on the efficacy and safety of TNS for treating neurogenic lower urinary tract dysfunction (NLUTD). EVIDENCE ACQUISITION The review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses Statement. EVIDENCE SYNTHESIS After screening 1943 articles, 16 studies (4 randomized controlled trials [RCTs], 9 prospective cohort studies, 2 retrospective case series, and 1 case report) enrolling 469 patients (283 women and 186 men) were included. Five studies reported on acute TNS and 11 on chronic TNS. In acute and chronic TNS, the mean increase of maximum cystometric capacity ranged from 56 to 132mL and from 49 to 150mL, and the mean increase of bladder volume at first detrusor overactivity ranged from 44 to 92mL and from 93 to 121mL, respectively. In acute and chronic TNS, the mean decrease of maximum detrusor pressure during the storage phase ranged from 5 to 15cm H2O and from 4 to 21cm H2O, respectively. In chronic TNS, the mean decrease in number of voids per 24h, in number of leakages per 24h, and in postvoid residual ranged from 3 to 7, from 1 to 4, and from 15 to 55mL, respectively. No TNS-related adverse events have been reported. Risk of bias and confounding was high in most studies. CONCLUSIONS Although preliminary data of RCTs and non-RCTs suggest TNS might be effective and safe for treating NLUTD, the evidence base is poor, derived from small, mostly noncomparative studies with a high risk of bias and confounding. More reliable data from well-designed RCTs are needed to reach definitive conclusions. PATIENT SUMMARY Early data suggest tibial nerve stimulation might be effective and safe for treating neurogenic lower urinary tract dysfunction, but more reliable evidence is required.
Resumo:
CONTEXT Transcutaneous electrical nerve stimulation (TENS) is a promising therapy for non-neurogenic lower urinary tract dysfunction and might also be a valuable option in patients with an underlying neurological disorder. OBJECTIVE We systematically reviewed all available evidence on the efficacy and safety of TENS for treating neurogenic lower urinary tract dysfunction. EVIDENCE ACQUISITION The review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses Statement. EVIDENCE SYNTHESIS After screening 1943 articles, 22 studies (two randomised controlled trials, 14 prospective cohort studies, five retrospective case series, and one case report) enrolling 450 patients were included. Eleven studies reported on acute TENS and 11 on chronic TENS. In acute TENS and chronic TENS, the mean increase of maximum cystometric capacity ranged from 69ml to 163ml and from 4ml to 156ml, the mean change of bladder volume at first detrusor overactivity from a decrease of 13ml to an increase of 175ml and from an increase of 10ml to 120ml, a mean decrease of maximum detrusor pressure at first detrusor overactivity from 18 cmH20 to 72 cmH20 and 8 cmH20, and a mean decrease of maximum storage detrusor pressure from 20 cmH20 to 58 cmH2O and from 3 cmH20 to 8 cmH2O, respectively. In chronic TENS, a mean decrease in the number of voids and leakages per 24h ranged from 1 to 3 and from 0 to 4, a mean increase of maximum flow rate from 2ml/s to 7ml/s, and a mean change of postvoid residual from an increase of 26ml to a decrease of 85ml. No TENS-related serious adverse events have been reported. Risk of bias and confounding was high in most studies. CONCLUSIONS Although preliminary data suggest TENS might be effective and safe for treating neurogenic lower urinary tract dysfunction, the evidence base is poor and more reliable data from well-designed randomised controlled trials are needed to make definitive conclusions. PATIENT SUMMARY Early data suggest that transcutaneous electrical nerve stimulation might be effective and safe for treating neurogenic lower urinary tract dysfunction, but more reliable evidence is required.
Resumo:
Measurements of maximum urethral closure pressure (MUCP) are a part of urodynamic investigations preceding an incontinence surgery and a part of urethral function tests.
Resumo:
OBJECTIVE: Aim of the study was to correlate urethral retro resistance pressure with the maximum urethral closure pressure (MUCP) and functional urethral length (FUL) in patients with urinary incontinence and healthy individuals. STUDY DESIGN: Two hundred and twenty patients with the complaint of urinary incontinence had a urodynamic examination including urethral pressure profiles and URP. Additionally, 15 healthy individuals without the complaint of any incontinence had their URP and urethral pressure profiles measured. The correlation of MUCP, FUL and URP were calculated using Graph Pad Instat 4.0 for windows. RESULTS: URP correlates well with the diagnosis of urodynamic stress incontinence. Correlation coefficient between URP and MUCP is 0.9262. Healthy individuals have significantly higher values for URP and MUCP. CONCLUSION: URP is a valuable less invasive test than conventional urethral function tests for the diagnosis of urodynamic incontinence with an excellent correlation of MUCP and URP.
Resumo:
The aim of this study was to compare the maximum urethral closure pressure (MUCP) measures with two different techniques: water perfused catheter and microtip transducer catheters with respect to reproducibility and comparability for urethral pressure measurements. Eighteen women with stress urinary incontinence had repeat static urethral pressure profilometry on a different day using a dual microtip transducer and water perfused catheter (Brown and Wickham). The investigators were blinded to the results of the other. The microtip measurements were taken in the 45 degrees upright sitting position with the patient at rest at a bladder capacity of 250 ml using an 8 Fr Gaeltec(R) double microtip transducer withdrawn at 1 mm/s, and the transducer was orientated in the three o'clock position. Three different measures were taken for each patient. Three water perfusion measurements were performed with the patient at rest in the 45 degrees upright position at a bladder capacity of 250 ml using an 8 Fr BARD dual lumen catheter withdrawn at 1 mm/s. The mean water perfusion MUCP measure was 26.1 cm H(2)0, significantly lower than the mean microtip measure of 35.7 cm H(2)0. The correlation coefficient comparing each water perfusion measurement with the other water perfusion measures in the same patient was excellent, at 0.95 (p = 0.01). Correlation coefficient comparing each microtip measure with the other microtip measure in the same patient was also good, ranging from 0.70 to 0.80. This study confirms that both water perfusion catheters and microtip transducers have excellent or very good reproducibility with an acceptable intraindividual variation for both methods.
Resumo:
A novel computer-assisted injection device for the delivery of highly viscous bone cements in vertebroplasty is presented. It addresses the shortcomings of manual injection systems ranging from low-pressure and poor level of control to device failure. The presented instrument is capable of generating a maximum pressure of 5000 kPa in traditional 6-ml syringes and provides an advanced control interface for precise cement delivery from outside radiation fields emitted by intraoperative imaging systems. The integrated real-time monitoring of injection parameters, such as flow-rate, volume, pressure, and viscosity, simplifies consistent documentation of interventions and establishes a basis for the identification of safe injection protocols on the longer term. Control algorithms prevent device failure due to overloading and provide means to immediately stop cement flow to avoid leakage into adjacent tissues.
Resumo:
The purpose of this single-center study was to report our initial experience with an implantable remote pressure sensor for aneurysm sac pressure measurement in patients post-endovascular aneurysm repair (EVAR) including short-term follow-up. A pressure sensor (EndoSure, Atlanta, GA) was implanted in 12 patients treated with different commercially available aortic endografts for EVAR. Pressure was read pre- and post-EVAR in the operating room. One-month follow-up (30 days +/- 6 days) was performed including sac pressure readings and IV contrast CT scans. Variables were compared using the paired Student's t test. An intraprocedure type-I endoleak and a type-III endoleak were successfully treated resulting in decreasing sac pressures. In all patients, post-EVAR systolic sac pressure decreased by an average of 33% (P = 0.005) compared to pre-EVAR measurements. One-month follow-up demonstrated a 47% decrease in systolic sac pressure (P = 0.05). On follow-up CT scans, the average maximum aneurysm diameter pre-EVAR was 6.3 +/- 1.6 cm and post-EVAR 6.0 +/- 1.7 cm (P=0.05). The diameter of the aneurysm sac was larger only in one patient with a type-III endoleak. Remote sac pressure measurement may provide important information in addition to imaging and may help to reduce the number of follow-up CT scans.
Resumo:
PURPOSE: We determined and compared urethral pressure measurements using air charged and microtip catheters in a prospective, single-blind, randomized trial. MATERIALS AND METHODS: A consecutive series of 64 women referred for urodynamic investigation underwent sequential urethral pressure measurements using an air charged and a microtip catheter in randomized order. Patients were blinded to the type and sequence of catheter used. Agreement between the 2 catheter systems was assessed using the Bland and Altman 95% limits of agreement method. RESULTS: Intraclass correlation coefficients of air charged and microtip catheters for maximum urethral closure pressure at rest were 0.97 and 0.93, and for functional profile length they were 0.9 and 0.78, respectively. Pearson's correlation coefficients and Lin's concordance coefficients of air charged and microtip catheters were r = 0.82 and rho = 0.79 for maximum urethral closure pressure at rest, and r = 0.73 and rho = 0.7 for functional profile length, respectively. When applying the Bland and Altman method, air charged catheters gave higher readings than microtip catheters for maximum urethral closure pressure at rest (mean difference 7.5 cm H(2)O) and functional profile length (mean difference 1.8 mm). There were wide 95% limits of agreement for differences in maximum urethral closure pressure at rest (-24.1 to 39 cm H(2)O) and functional profile length (-7.7 to 11.3 mm). CONCLUSIONS: For urethral pressure measurement the air charged catheter is at least as reliable as the microtip catheter and it generally gives higher readings. However, air charged and microtip catheters cannot be used interchangeably for clinical purposes because of insufficient agreement. Hence, clinicians should be aware that air charged and microtip catheters may yield completely different results, and these differences should be acknowledged during clinical decision making.
Resumo:
BACKGROUND It is often assumed that blood pressure increases acutely after major stroke, resulting in so-called post-stroke hypertension. In view of evidence that the risks and benefits of blood pressure-lowering treatment in acute stroke might differ between patients with major ischaemic stroke and those with primary intracerebral haemorrhage, we compared acute-phase and premorbid blood pressure levels in these two disorders. METHODS In a population-based study in Oxfordshire, UK, we recruited all patients presenting with stroke between April 1, 2002, and March 31, 2012. We compared all acute-phase post-event blood pressure readings with premorbid readings from 10-year primary care records in all patients with acute major ischaemic stroke (National Institutes of Health Stroke Scale >3) versus those with acute intracerebral haemorrhage. FINDINGS Of 653 consecutive eligible patients, premorbid and acute-phase blood pressure readings were available for 636 (97%) individuals. Premorbid blood pressure (total readings 13,244) had been measured on a median of 17 separate occasions per patient (IQR 8-31). In patients with ischaemic stroke, the first acute-phase systolic blood pressure was much lower than after intracerebral haemorrhage (158·5 mm Hg [SD 30·1] vs 189·8 mm Hg [38·5], p<0·0001; for patients not on antihypertensive treatment 159·2 mm Hg [27·8] vs 193·4 mm Hg [37·4], p<0·0001), was little higher than premorbid levels (increase of 10·6 mm Hg vs 10-year mean premorbid level), and decreased only slightly during the first 24 h (mean decrease from <90 min to 24 h 13·6 mm Hg). By contrast with findings in ischaemic stroke, the mean first systolic blood pressure after intracerebral haemorrhage was substantially higher than premorbid levels (mean increase of 40·7 mm Hg, p<0·0001) and fell substantially in the first 24 h (mean decrease of 41·1 mm Hg; p=0·0007 for difference from decrease in ischaemic stroke). Mean systolic blood pressure also increased steeply in the days and weeks before intracerebral haemorrhage (regression p<0·0001) but not before ischaemic stroke. Consequently, the first acute-phase blood pressure reading after primary intracerebral haemorrhage was more likely than after ischaemic stroke to be the highest ever recorded (OR 3·4, 95% CI 2·3-5·2, p<0·0001). In patients with intracerebral haemorrhage seen within 90 min, the highest systolic blood pressure within 3 h of onset was 50 mm Hg higher, on average, than the maximum premorbid level whereas that after ischaemic stroke was 5·2 mm Hg lower (p<0·0001). INTERPRETATION Our findings suggest that systolic blood pressure is substantially raised compared with usual premorbid levels after intracerebral haemorrhage, whereas acute-phase systolic blood pressure after major ischaemic stroke is much closer to the accustomed long-term premorbid level, providing a potential explanation for why the risks and benefits of lowering blood pressure acutely after stroke might be expected to differ. FUNDING Wellcome Trust, Wolfson Foundation, UK Medical Research Council, Stroke Association, British Heart Foundation, National Institute for Health Research.
Resumo:
BACKGROUND AND PURPOSE Visit-to-visit variability in systolic blood pressure (SBP) is associated with an increased risk of stroke and was reduced in randomized trials by calcium channel blockers and diuretics but not by renin-angiotensin system inhibitors. However, time of day effects could not be determined. Day-to-day variability on home BP readings predicts stroke risk and potentially offers a practical method of monitoring response to variability-directed treatment. METHODS SBP mean, maximum, and variability (coefficient of variation=SD/mean) were determined in 500 consecutive transient ischemic attack or minor stroke patients on 1-month home BP monitoring (3 BPs, 3× daily). Hypertension was treated to a standard protocol. Differences in SBP variability from 3 to 10 days before to 8 to 15 days after starting or increasing calcium channel blockers/diuretics versus renin-angiotensin system inhibitors versus both were compared by general linear models, adjusted for risk factors and baseline BP. RESULTS Among 288 eligible interventions, variability in SBP was reduced after increased treatment with calcium channel blockers/diuretics versus both versus renin-angiotensin system inhibitors (-4.0 versus 6.9 versus 7.8%; P=0.015), primarily because of effects on maximum SBP (-4.6 versus -1.0 versus -1.0%; P=0.001), with no differences in effect on mean SBP. Class differences were greatest for early-morning SBP variability (3.6 versus 17.0 versus 38.3; P=0.002) and maximum (-4.8 versus -2.0 versus -0.7; P=0.001), with no effect on midmorning (P=0.29), evening (P=0.65), or diurnal variability (P=0.92). CONCLUSIONS After transient ischemic attack or minor stroke, calcium channel blockers and diuretics reduced variability and maximum home SBP, primarily because of effects on morning readings. Home BP readings enable monitoring of response to SBP variability-directed treatment in patients with recent cerebrovascular events.
Resumo:
BACKGROUND Blood pressure (BP) is known to aggregate in families. Yet, heritability estimates are population-specific and no Swiss data have been published so far. We estimated the heritability of ambulatory and office BP in a Swiss population-based sample. METHODS The Swiss Kidney Project on Genes in Hypertension is a population-based family study focusing on BP genetics. Office and ambulatory BP were measured in 1009 individuals from 271 nuclear families. Heritability was estimated for SBP, DBP, and pulse pressure using a maximum likelihood method implanted in the Statistical Analysis in Genetic Epidemiology software. RESULTS The 518 women and 491 men included in this analysis had a mean (±SD) age of 48.3 (±17.4) and 47.3 (±17.7) years, and a mean BMI of 23.8 (±4.2) and 25.9 (±4.1) kg/m, respectively. Narrow-sense heritability estimates (±standard error) for ambulatory SBP, DBP, and pulse pressure were 0.37 ± 0.07, 0.26 ± 0.07, and 0.29 ± 0.07 for 24-h BP; 0.39 ± 0.07, 0.28 ± 0.07, and 0.27 ± 0.07 for day BP; and 0.25 ± 0.07, 0.20 ± 0.07, and 0.30 ± 0.07 for night BP, respectively (all P < 0.001). Heritability estimates for office SBP, DBP, and pulse pressure were 0.21 ± 0.08, 0.25 ± 0.08, and 0.18 ± 0.07 (all P < 0.01). CONCLUSIONS We found significant heritability estimates for both ambulatory and office BP in this Swiss population-based study. Our findings justify the ongoing search for the genetic determinants of BP.