7 resultados para Matter wave statistics
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Vibrations, electromagnetic oscillations, and temperature drifts are among the main reasons for dephasing in matter-wave interferometry. Sophisticated interferometry experiments, e.g., with ions or heavy molecules, often require integration times of several minutes due to the low source intensity or the high velocity selection. Here we present a scheme to suppress the influence of such dephasing mechanisms—especially in the low-frequency regime—by analyzing temporal and spatial particle correlations available in modern detectors. Such correlations can reveal interference properties that would otherwise be washed out due to dephasing by external oscillating signals. The method is shown experimentally in a biprism electron interferometer where a perturbing oscillation is artificially introduced by a periodically varying magnetic field. We provide a full theoretical description of the particle correlations where the perturbing frequency and amplitude can be revealed from the disturbed interferogram. The original spatial fringe pattern without the perturbation can thereby be restored. The technique can be applied to lower the general noise requirements in matter-wave interferometers. It allows for the optimization of electromagnetic shielding and decreases the efforts for vibrational or temperature stabilization.
Resumo:
Emulsion detectors feature a very high position resolution and consequently represent an ideal device when particle detection is required at the micrometric scale. This is the case of quantum interferometry studies with antimatter, where micrometric fringes have to be measured. In this framework, we designed and realized a new emulsion based detector characterized by a gel enriched in terms of silver bromide crystal contents poured on a glass plate. We tested the sensitivity of such a detector to low energy positrons in the range 10–20 keV . The obtained results prove that nuclear emulsions are highly efficient at detecting positrons at these energies. This achievement paves the way to perform matter-wave interferometry with positrons using this technology.
Resumo:
In schizophrenia there is a consistent epidemiological finding of a birth excess in winter and spring. Season of birth is thought to act as a proxy indicator for harmful environmental factors during foetal maturation. There is evidence that prenatal exposure to harmful environmental factors may trigger pathologic processes in the neurodevelopment, which subsequently increase the risk of schizophrenia. Since brain white matter alterations have repeatedly been found in schizophrenia, the objective of this study was to investigate whether white matter integrity was related to the season of birth in patients with schizophrenia. Thirty-four patients with schizophrenia and 33 healthy controls underwent diffusion tensor imaging. Differences in the fractional anisotropy maps of schizophrenia patients and healthy controls born in different seasons were analysed with tract-based spatial statistics. A significant main effect of season of birth and an interaction of group and season of birth showed that patients born in summer had significantly lower fractional anisotropy in widespread white matter regions than those born in the remainder of the year. Additionally, later age of schizophrenia onset was found in patients born in winter months. The current findings indicate a relationship of season of birth and white matter alterations in schizophrenia and consequently support the neurodevelopmental hypothesis of early pathological mechanisms in schizophrenia.
Resumo:
Phase-sensitive X-ray imaging shows a high sensitivity towards electron density variations, making it well suited for imaging of soft tissue matter. However, there are still open questions about the details of the image formation process. Here, a framework for numerical simulations of phase-sensitive X-ray imaging is presented, which takes both particle- and wave-like properties of X-rays into consideration. A split approach is presented where we combine a Monte Carlo method (MC) based sample part with a wave optics simulation based propagation part, leading to a framework that takes both particle- and wave-like properties into account. The framework can be adapted to different phase-sensitive imaging methods and has been validated through comparisons with experiments for grating interferometry and propagation-based imaging. The validation of the framework shows that the combination of wave optics and MC has been successfully implemented and yields good agreement between measurements and simulations. This demonstrates that the physical processes relevant for developing a deeper understanding of scattering in the context of phase-sensitive imaging are modelled in a sufficiently accurate manner. The framework can be used for the simulation of phase-sensitive X-ray imaging, for instance for the simulation of grating interferometry or propagation-based imaging.
Resumo:
PURPOSE Management of ureteral stones remains controversial. To determine whether optimizing extracorporeal shock wave lithotripsy (ESWL) delivery rates improves treatment of solitary ureteral stones, we compared outcomes of two SW delivery rates in a prospective, randomized trial. MATERIALS AND METHODS From July 2010 to October 2012, 254 consecutive patients were randomized to undergo ESWL at SW delivery rates of either 60 pulses (n=130) or 90 pulses (n=124) per min. The primary endpoint was stone-free rate at 3-month follow-up. Secondary endpoints included stone disintegration, treatment time, complications, and the rate of secondary treatments. Descriptive statistics were used to compare endpoints between the two groups. Adjusted odds ratios and 95% confidence intervals were calculated to assess predictors of success. RESULTS The stone-free rate at 3 months was significantly higher in patients who underwent ESWL at a SW delivery rate of 90 pulses per min than in those receiving 60 pulses (91% vs. 80%, p=0.01). Patients with proximal and mid-ureter stones, but not those with distal ureter stones, accounted for the observed difference (100% vs. 83%; p=0.005; 96% vs. 73%, p=0.03; and 81% vs. 80%, p=0.9, respectively). Treatment time, complications, and the rate of secondary treatments were comparable between the two groups. In multivariable analysis, SW delivery rate of 90 pulses per min, proximal stone location, stone density, stone size and the absence of an indwelling JJ stent were independent predictors of success. CONCLUSIONS Optimization of ESWL delivery rates can achieve excellent results for ureteral stones.
Resumo:
Over the years, a drastic increase in online information disclosure spurs a wave of concerns from multiple stakeholders. Among others, users resent the “behind the closed doors” processing of their personal data by companies. Privacy policies are supposed to inform users how their personal information is handled by a website. However, several studies have shown that users rarely read privacy policies for various reasons, not least because limitedly readable policy texts are difficult to understand. Based on our online survey with over 440 responses, we examine the objective and subjective readability of privacy policies and investigate their impact on users’ trust in five big Internet services. Our findings show the stronger a user believes in having understood the privacy policy, the higher he or she trusts a web site across all companies we studied. Our results call for making readability of privacy policies more accessible to an average reader.
Resumo:
BACKGROUND White matter (WM) fibers connect different brain regions and are critical for proper brain function. However, little is known about the cerebral blood flow in WM and its relation to WM microstructure. Recent improvements in measuring cerebral blood flow (CBF) by means of arterial spin labeling (ASL) suggest that the signal in white matter may be detected. Its implications for physiology needs to be extensively explored. For this purpose, CBF and its relation to anisotropic diffusion was analyzed across subjects on a voxel-wise basis with tract-based spatial statistics (TBSS) and also across white matter tracts within subjects. METHODS Diffusion tensor imaging and ASL were acquired in 43 healthy subjects (mean age = 26.3 years). RESULTS CBF in WM was observed to correlate positively with fractional anisotropy across subjects in parts of the splenium of corpus callosum, the right posterior thalamic radiation (including the optic radiation), the forceps major, the right inferior fronto-occipital fasciculus, the right inferior longitudinal fasciculus and the right superior longitudinal fasciculus. Furthermore, radial diffusivity correlated negatively with CBF across subjects in similar regions. Moreover, CBF and FA correlated positively across white matter tracts within subjects. CONCLUSION The currently observed findings on a macroscopic level might reflect the metabolic demand of white matter on a microscopic level involving myelination processes or axonal function. However, the exact underlying physiological mechanism of this relationship needs further evaluation.