12 resultados para Martin, Thomas Ignace, 1783-1834.

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

One of the major challenges for a mission to the Jovian system is the radiation tolerance of the spacecraft (S/C) and the payload. Moreover, being able to achieve science observations with high signal to noise ratios (SNR), while passing through the high flux radiation zones, requires additional ingenuity on the part of the instrument provider. Consequently, the radiation mitigation is closely intertwined with the payload, spacecraft and trajectory design, and requires a systems-level approach. This paper presents a design for the Io Volcano Observer (IVO), a Discovery mission concept that makes multiple close encounters with Io while orbiting Jupiter. The mission aims to answer key outstanding questions about Io, especially the nature of its intense active volcanism and the internal processes that drive it. The payload includes narrow-angle and wide-angle cameras (NAC and WAC), dual fluxgate magnetometers (FGM), a thermal mapper (ThM), dual ion and neutral mass spectrometers (INMS), and dual plasma ion analyzers (PIA). The radiation mitigation is implemented by drawing upon experiences from designs and studies for missions such as the Radiation Belt Storm Probes (RBSP) and Jupiter Europa Orbiter (JEO). At the core of the radiation mitigation is IVO's inclined and highly elliptical orbit, which leads to rapid passes through the most intense radiation near Io, minimizing the total ionizing dose (177 krads behind 100 mils of Aluminum with radiation design margin (RDM) of 2 after 7 encounters). The payload and the spacecraft are designed specifically to accommodate the fast flyby velocities (e.g. the spacecraft is radioisotope powered, remaining small and agile without any flexible appendages). The science instruments, which collect the majority of the high-priority data when close to Io and thus near the peak flux, also have to mitigate transient noise in their detectors. The cameras use a combination of shielding and CMOS detectors with extremely fast readout to mi- imize noise. INMS microchannel plate detectors and PIA channel electron multipliers require additional shielding. The FGM is not sensitive to noise induced by energetic particles and the ThM microbolometer detector is nearly insensitive. Detailed SNR calculations are presented. To facilitate targeting agility, all of the spacecraft components are shielded separately since this approach is more mass efficient than using a radiation vault. IVO uses proven radiation-hardened parts (rated at 100 krad behind equivalent shielding of 280 mils of Aluminum with RDM of 2) and is expected to have ample mass margin to increase shielding if needed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: This is the first study investigating neoadjuvant interstitial high-dose-rate (HDR) brachytherapy combined with chemotherapy in patients with breast cancer. The goal was to evaluate the type of surgical treatment, histopathologic response, side effects, local control, and survival. PATIENTS AND METHODS: 53 patients, who could not be treated with breast-conserving surgery due to initial tumor size (36/53) or due to an unfavorable breast-tumor ratio (17/53), were analyzed retrospectively. All but one were in an intermediate/high-risk group (St. Gallen criteria). The patients received a neoadjuvant protocol consisting of systemic chemotherapy combined with fractionated HDR brachytherapy (2 x 5 Gy/day, total dose 30 Gy). In cases, where breast-conserving surgery was performed, patients received additional external-beam radiotherapy (EBRT, 1.8 Gy/day, total dose 50.4 Gy). In patients, who underwent mastectomy but showed an initial tumor size of T3/T4 and/or more than three infiltrated lymph nodes, EBRT was also performed. RESULTS: In 30/53 patients (56.6%) breast-conserving surgery could be performed. The overall histopathologic response rate was 96.2% with a complete remission in 28.3% of patients. 49/53 patients were evaluable for follow-up. After a median of 58 months (45-72 months), one patient showed a mild fibrosis of the breast tissue, three patients had mild to moderate lymphatic edema of the arm. 6/49 (12.2%) patients died of distant metastases, 4/49 (8.2%) were alive with disease, and 39/49 (79.6%) were free from disease. Local recurrence was observed in only one case (2%) 40 months after primary therapy. After mastectomy, this patient is currently free from disease. CONCLUSION: The combination of interstitial HDR brachytherapy and chemotherapy is a well-tolerated and effective neoadjuvant treatment in patients with breast cancer. Compared to EBRT, treatment time is short. Postoperative EBRT of the whole breast -- if necessary -- is still possible after neoadjuvant brachytherapy. Even though the number of patients does not permit definite conclusions, the results are promising regarding survival and the very low rate of local recurrences.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: The simple bedside method for sampling undiluted distal pulmonary edema fluid through a normal suction catheter (s-Cath) has been experimentally and clinically validated. However, there are no data comparing non-bronchoscopic bronchoalveolar lavage (mini-BAL) and s-Cath for assessing lung inflammation in acute hypoxaemic respiratory failure. We designed a prospective study in two groups of patients, those with acute lung injury (ALI)/acute respiratory distress syndrome (ARDS) and those with acute cardiogenic lung edema (ACLE), designed to investigate the clinical feasibility of these techniques and to evaluate inflammation in both groups using undiluted sampling obtained by s-Cath. To test the interchangeability of the two methods in the same patient for studying the inflammation response, we further compared mini-BAL and s-Cath for agreement of protein concentration and percentage of polymorphonuclear cells (PMNs). METHODS: Mini-BAL and s-Cath sampling was assessed in 30 mechanically ventilated patients, 21 with ALI/ARDS and 9 with ACLE. To analyse agreement between the two sampling techniques, we considered only simultaneously collected mini-BAL and s-Cath paired samples. The protein concentration and polymorphonuclear cell (PMN) count comparisons were performed using undiluted sampling. Bland-Altman plots were used for assessing the mean bias and the limits of agreement between the two sampling techniques; comparison between groups was performed by using the non-parametric Mann-Whitney-U test; continuous variables were compared by using the Student t-test, Wilcoxon signed rank test, analysis of variance or Student-Newman-Keuls test; and categorical variables were compared by using chi-square analysis or Fisher exact test. RESULTS: Using protein content and PMN percentage as parameters, we identified substantial variations between the two sampling techniques. When the protein concentration in the lung was high, the s-Cath was a more sensitive method; by contrast, as inflammation increased, both methods provided similar estimates of neutrophil percentages in the lung. The patients with ACLE showed an increased PMN count, suggesting that hydrostatic lung edema can be associated with a concomitant inflammatory process. CONCLUSIONS: There are significant differences between the s-Cath and mini-BAL sampling techniques, indicating that these procedures cannot be used interchangeably for studying the lung inflammatory response in patients with acute hypoxaemic lung injury.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present 3-D simulations of impacts into Asteroid 21 Lutetia, the subject of a fly-by by the European Space Agency's Rosetta mission to Comet 67P/Churyumov-Gerasimenko. Using a 3-D shape model of the asteroid, impacts of sizes sufficient to reproduce the observed craters in Lutetia's North Polar Crater Cluster (NPCC) as observed by the OSIRIS experiment have been simulated using the Smoothed Particle Hydrodynamics technique. The asteroid itself has been modelled both as a homogeneous body and as a body with an iron core.

Relevância:

30.00% 30.00%

Publicador: