13 resultados para Manufacturing departments

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

SUMMARY The aim of this study was to evaluate the influence of surface roughness on surface hardness (Vickers; VHN), elastic modulus (EM), and flexural strength (FLS) of two computer-aided design/computer-aided manufacturing (CAD/CAM) ceramic materials. One hundred sixty-two samples of VITABLOCS Mark II (VMII) and 162 samples of IPS Empress CAD (IPS) were ground according to six standardized protocols producing decreasing surface roughnesses (n=27/group): grinding with 1) silicon carbide (SiC) paper #80, 2) SiC paper #120, 3) SiC paper #220, 4) SiC paper #320, 5) SiC paper #500, and 6) SiC paper #1000. Surface roughness (Ra/Rz) was measured with a surface roughness meter, VHN and EM with a hardness indentation device, and FLS with a three-point bending test. To test for a correlation between surface roughness (Ra/Rz) and VHN, EM, or FLS, Spearman rank correlation coefficients were calculated. The decrease in surface roughness led to an increase in VHN from (VMII/IPS; medians) 263.7/256.5 VHN to 646.8/601.5 VHN, an increase in EM from 45.4/41.0 GPa to 66.8/58.4 GPa, and an increase in FLS from 49.5/44.3 MPa to 73.0/97.2 MPa. For both ceramic materials, Spearman rank correlation coefficients showed a strong negative correlation between surface roughness (Ra/Rz) and VHN or EM and a moderate negative correlation between Ra/Rz and FLS. In conclusion, a decrease in surface roughness generally improved the mechanical properties of the CAD/CAM ceramic materials tested. However, FLS was less influenced by surface roughness than expected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND The variant Creutzfeldt-Jakob disease incidence peaked a decade ago and has since declined. Based on epidemiologic evidence, the causative agent, pathogenic prion, has not constituted a tangible contamination threat to large-scale manufacturing of human plasma-derived proteins. Nonetheless, manufacturers have studied the prion removal capabilities of various manufacturing steps to better understand product safety. Collectively analyzing the results could reveal experimental reproducibility and detect trends and mechanisms driving prion removal. STUDY DESIGN AND METHODS Plasma Protein Therapeutics Association member companies collected more than 200 prion removal studies on plasma protein manufacturing steps, including precipitation, adsorption, chromatography, and filtration, as well as combined steps. The studies used a range of model spiking agents and bench-scale process replicas. The results were grouped based on key manufacturing variables to identify factors impacting removal. The log reduction values of a group are presented for comparison. RESULTS Overall prion removal capacities evaluated by independent groups were in good agreement. The removal capacity evaluated using biochemical assays was consistent with prion infectivity removal measured by animal bioassays. Similar reduction values were observed for a given step using various spiking agents, except highly purified prion protein in some circumstances. Comparison between combined and single-step studies revealed complementary or overlapping removal mechanisms. Steps with high removal capacities represent the conditions where the physiochemical differences between prions and therapeutic proteins are most significant. CONCLUSION The results support the intrinsic ability of certain plasma protein manufacturing steps to remove prions in case of an unlikely contamination, providing a safeguard to products.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Intracoronary application of BM-derived cells for the treatment of acute myocardial infarction (AMI) is currently being studied intensively. Simultaneously, strict legal requirements surround the production of cells for clinical studies. Thus good manufacturing practice (GMP)-compliant collection and preparation of BM for patients with AMI was established by the Cytonet group. METHODS: As well as fulfillment of standard GMP requirements, including a manufacturing license, validation of the preparation process and the final product was performed. Whole blood (n=6) and BM (n=3) validation samples were processed under GMP conditions by gelafundin or hydroxyethylstarch sedimentation in order to reduce erythrocytes/platelets and volume and to achieve specifications defined in advance. Special attention was paid to the free potassium (<6 mmol/L), some rheologically relevant cellular characteristics (hematocrit <0.45, platelets <450 x 10(6)/mL) and the sterility of the final product. RESULTS: The data were reviewed and GMP compliance was confirmed by the German authorities (Paul-Ehrlich Institute). Forty-five BM cell preparations for clinical use were carried out following the validated methodology and standards. Additionally three selections of CD34+ BM cells for infusion were performed. All specification limits were met. Discussion In conclusion, preparation of BM cells for intracoronary application is feasible under GMP conditions. As the results of sterility testing may not be available at the time of intracoronary application, the highest possible standards to avoid bacterial and other contaminations have to be applied. The increased expense of the GMP-compliant process can be justified by higher safety for patients and better control of the final product.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: In some Western countries, more and more patients seek initial treatment even for minor injuries at emergency units of hospitals. The initial evaluation and treatment as well as aftercare of these patients require large amounts of personnel and logistical resources, which are limited and costly, especially if compared to treatment by a general practitioner. In this study, we investigated whether outsourcing from our level 1 trauma center to a general practitioner has an influence on patient satisfaction and compliance. METHODS: This prospective, randomized study, included n = 100 patients who suffered from a lateral ankle ligament injury grade I-II (16, 17). After radiological exclusion of osseous lesions, the patients received early functional treatment and were shown physical therapy exercises to be done at home, without immobilization or the use of stabilizing ortheses. The patients were randomly assigned into two groups of 50 patients each: Group A (ER): Follow-up and final examination in the hospital's emergency unit. Group B (GP): Follow-up by general practitioner, final examination at hospital's emergency unit. The patients were surveyed regarding their satisfaction with the treatment and outcome of the treatment. RESULTS: Female and male patients were equally represented in both groups. The age of the patients ranged from 16 - 64 years, with a mean age of 34 years (ER) and 35 years (GP). 98% (n = 98) of all patients were satisfied with their treatment, and 93% (n = 93) were satisfied with the outcome. For these parameters no significant difference between the two groups could be noted (p = 0.7406 and 0.7631 respectively). 39% of all patients acquired stabilizing ortheses like ankle braces (Aircast, Malleoloc etc.) on their own initiative. There was a not significant tendency for more self-acquired ortheses in the group treated by general practicioners (p = 0,2669). CONCLUSION: Patients who first present at the ER with a lateral ankle ligament injury grade I-II can be referred to a general practitioner for follow-up treatment without affecting patient satisfaction regarding treatment and treatment outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: A multi-centre study has been conducted, during 2005, by means of a questionnaire posted on the Italian Society of Emergency Medicine (SIMEU) web page. Our intention was to carry out an organisational and functional analysis of Italian Emergency Departments (ED) in order to pick out some macro-indicators of the activities performed. Participation was good, in that 69 ED (3,285,440 admissions to emergency services) responded to the questionnaire. METHODS: The study was based on 18 questions: 3 regarding the personnel of the ED, 2 regarding organisational and functional aspects, 5 on the activity of the ED, 7 on triage and 1 on the assessment of the quality perceived by the users of the ED. RESULTS AND CONCLUSION: The replies revealed that 91.30% of the ED were equipped with data-processing software, which, in 96.83% of cases, tracked the entire itinerary of the patient. About 48,000 patients/year used the ED: 76.72% were discharged and 18.31% were hospitalised. Observation Units were active in 81.16% of the ED examined. Triage programmes were in place in 92.75% of ED: in 75.81% of these, triage was performed throughout the entire itinerary of the patient; in 16.13% it was performed only symptom-based, and in 8.06% only on-call. Of the patients arriving at the ED, 24.19% were assigned a non-urgent triage code, 60.01% a urgent code, 14.30% a emergent code and 1.49% a life-threatening code. Waiting times were: 52.39 min for non-urgent patients, 40.26 min for urgent, 12.08 for emergent, and 1.19 for life-threatening patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES Optical scanners combined with computer-aided design and computer-aided manufacturing (CAD/CAM) technology provide high accuracy in the fabrication of titanium (TIT) and zirconium dioxide (ZrO) bars. The aim of this study was to compare the precision of fit of CAD/CAM TIT bars produced with a photogrammetric and a laser scanner. METHODS Twenty rigid CAD/CAM bars were fabricated on one single edentulous master cast with 6 implants in the positions of the second premolars, canines and central incisors. A photogrammetric scanner (P) provided digitized data for TIT-P (n=5) while a laser scanner (L) was used for TIT-L (n=5). The control groups consisted of soldered gold bars (gold, n=5) and ZrO-P with similar bar design. Median vertical distance between implant and bar platforms from non-tightened implants (one-screw test) was calculated from mesial, buccal and distal scanning electron microscope measurements. RESULTS Vertical microgaps were not significantly different between TIT-P (median 16μm; 95% CI 10-27μm) and TIT-L (25μm; 13-32μm). Gold (49μm; 12-69μm) had higher values than TIT-P (p=0.001) and TIT-L (p=0.008), while ZrO-P (35μm; 17-55μm) exhibited higher values than TIT-P (p=0.023). Misfit values increased in all groups from implant position 23 (3 units) to 15 (10 units), while in gold and TIT-P values decreased from implant 11 toward the most distal implant 15. SIGNIFICANCE CAD/CAM titanium bars showed high precision of fit using photogrammetric and laser scanners. In comparison, the misfit of ZrO bars (CAM/CAM, photogrammetric scanner) and soldered gold bars was statistically higher but values were clinically acceptable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Emergency departments (EDs) are an essential component of any developed health care system. There is, however, no national description of EDs in Switzerland. Our objective was to establish the number and location of EDs, patient visits and flow, medical staff and organization, and capabilities in 2006, as a benchmark before emergency medicine became a subspecialty in Switzerland. METHODS In 2007, we started to create an inventory of all hospital-based EDs with a preliminary list from the Swiss Society of Emergency and Rescue Medicine that was improved with input from ED physicians nationwide. EDs were eligible if they offered acute care 24 h per day, 7 days per week. Our goal was to have 2006 data from at least 80% of all EDs. The survey was initiated in 2007 and the 80% threshold reached in 2012. RESULTS In 2006, Switzerland had a total of 138 hospital-based EDs. The number of ED visits was 1.475 million visits or 20 visits per 100 inhabitants. The median number of visits was 8,806 per year; 25% of EDs admitted 5,000 patients or less, 31% 5,001-10,000 patients, 26% 10,001-20,000 patients, and 17% >20,000 patients per year. Crowding was reported by 84% of EDs with >20,000 visits/year. Residents with limited experience provided care for 77% of visits. Imaging was not immediately available for all patients: standard X-ray within 15 min (70%), non-contrast head CT scan within 15 min (38%), and focused sonography for trauma (70%); 67% of EDs had an intensive care unit within the hospital, and 87% had an operating room always available. CONCLUSIONS Swiss EDs were significant providers of health care in 2006. Crowding, physicians with limited experience, and the heterogeneity of emergency care capabilities were likely threats to the ubiquitous and consistent delivery of quality emergency care, particularly for time-sensitive conditions. Our survey establishes a benchmark to better understand future improvements in Swiss emergency care.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the coming decades, old patients will account for an increasing proportion of emergency department (ED) visits. During or after their stay in the ED, they more frequently suffer adverse outcomes than younger patients. There is evidence that specific age-centred approaches improve the outcomes. We therefore reviewed specific conditions needing particular attention in older ED patients, such as cognitive disorders and delirium, impaired mobility and falls, as well as problems related to the activities of daily living, disability, poly-pharmacy, adverse drug effects, co-morbidity and atypical presentation. We also propose steps to further improve the quality of care in older ED patients by using appropriate age-centred management.