63 resultados para Magnetic charge and topology of dyon field

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Low-field (LF) (0.2-0.4T) magnetic resonance (MR) imaging predominates in veterinary practice. Advantages of LF MR include reduced costs, better patient access, and greater safety. High quality examinations can be achieved using appropriate protocols and investing more scanning time than with high-field (HF) systems. The main disadvantage of LF MR is the reduced signal to noise ratio compared with HF systems. LF MR protocols for small animal brain and spine imaging are described.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The bulk magnetic mineral record from Lake Ohrid, spanning the past 637 kyr, reflects large-scale shifts in hydrological conditions, and, superimposed, a strong signal of environmental conditions on glacial–interglacial and millennial timescales. A shift in the formation of early diagenetic ferrimagnetic iron sulfides to siderites is observed around 320 ka. This change is probably associated with variable availability of sulfide in the pore water. We propose that sulfate concentrations were significantly higher before  ∼  320 ka, due to either a higher sulfate flux or lower dilution of lake sulfate due to a smaller water volume. Diagenetic iron minerals appear more abundant during glacials, which are generally characterized by higher Fe / Ca ratios in the sediments. While in the lower part of the core the ferrimagnetic sulfide signal overprints the primary detrital magnetic signal, the upper part of the core is dominated by variable proportions of high- to low-coercivity iron oxides. Glacial sediments are characterized by high concentration of high-coercivity magnetic minerals (hematite, goethite), which relate to enhanced erosion of soils that had formed during preceding interglacials. Superimposed on the glacial–interglacial behavior are millennial-scale oscillations in the magnetic mineral composition that parallel variations in summer insolation. Like the processes on glacial–interglacial timescales, low summer insolation and a retreat in vegetation resulted in enhanced erosion of soil material. Our study highlights that rock-magnetic studies, in concert with geochemical and sedimentological investigations, provide a multi-level contribution to environmental reconstructions, since the magnetic properties can mirror both environmental conditions on land and intra-lake processes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE The results of Interventional Management of Stroke (IMS) III, Magnetic Resonance and REcanalization of Stroke Clots Using Embolectomy (MR RESCUE), and SYNTHESIS EXPANSION trials are expected to affect the practice of endovascular treatment for acute ischemic stroke. The purpose of this report is to review the components of the designs and methods of these trials and to describe the influence of those components on the interpretation of trial results. METHODS A critical review of trial design and conduct of IMS III, MR RESCUE, and SYNTHESIS EXPANSION is performed with emphasis on patient selection, shortcomings in procedural aspects, and methodology of data ascertainment and analysis. The influence of each component is estimated based on published literature including multicenter clinical trials reporting on endovascular treatment for acute ischemic stroke and myocardial infarction. RESULTS We critically examined the time interval between symptom onset and treatment and rates of angiographic recanalization to differentiate between "endovascular treatment" and "parameter optimized endovascular treatment" as it relates to the IMS III, MR RESCUE, and SYNTHESIS EXPANSION trials. All the three trials failed to effectively test "parameter optimized endovascular treatment" due to the delay between symptom onset and treatment and less than optimal rates of recanalization. In all the three trials, the magnitude of benefit with endovascular treatment required to reject the null hypothesis was larger than could be expected based on previous studies. The IMS III and SYNTHESIS EXPANSION trials demonstrated that rates of symptomatic intracerebral hemorrhages subsequent to treatment are similar between IV thrombolytics and endovascular treatment in matched acute ischemic stroke patients. The trials also indirectly validated the superiority/equivalence of IV thrombolytics (compared with endovascular treatment) in patients with minor neurological deficits and those without large vessel occlusion on computed tomographic/magnetic resonance angiography. CONCLUSIONS The results do not support a large magnitude benefit of endovascular treatment in subjects randomized in all the three trials. The possibility that benefits of a smaller magnitude exist in certain patient populations cannot be excluded. Large magnitude benefits can be expected with implementation of "parameter optimized endovascular treatment" in patients with ischemic stroke who are candidates for IV thrombolytics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To determine interobserver and intraobserver agreement for results of low-field magnetic resonance imaging (MRI) in dogs with and without disk-associated wobbler syndrome (DAWS). DESIGN: Validation study. ANIMALS: 21 dogs with and 23 dogs without clinical signs of DAWS. PROCEDURES: For each dog, MRI of the cervical vertebral column was performed. The MRI studies were presented in a randomized sequence to 4 board-certified radiologists blinded to clinical status. Observers assessed degree of disk degeneration, disk-associated and dorsal compression, alterations in intraspinal signal intensity (ISI), vertebral body abnormalities, and new bone formation and categorized each study as originating from a clinically affected or clinically normal dog. Interobserver agreement was calculated for 44 initial measurements for each observer. Intraobserver agreement was calculated for 11 replicate measurements for each observer. RESULTS: There was good interobserver agreement for ratings of disk degeneration and vertebral body abnormalities and moderate interobserver agreement for ratings of disk-associated compression, dorsal compression, alterations in ISI, new bone formation, and suspected clinical status. There was very good intraobserver agreement for ratings of disk degeneration, disk-associated compression, alterations in ISI, vertebral body abnormalities, and suspected clinical status. There was good intraobserver agreement for ratings of dorsal compression and new bone formation. Two of 21 clinically affected dogs were erroneously categorized as clinically normal, and 4 of 23 clinically normal dogs were erroneously categorized as clinically affected. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggested that variability exists among observers with regard to results of MRI in dogs with DAWS and that MRI could lead to false-positive and false-negative assessments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Time-of-flight (ToF) and phase contrast (PC) magnetic resonance angiographies (MRAs) are noninvasive applications to depict the cerebral arteries. Both approaches can image the cerebral vasculature without the administration of intravenous contrast. Therefore, it is used in routine clinical evaluation of cerebrovascular diseases, e.g., aneurysm and arteriovenous malformations. However, subtle microvascular disease usually cannot be resolved with standard, clinical-field-strength MRA. The purpose of this study was to compare the ability of ToF and PC MRA to visualize the cerebral arteries at increasing field strengths.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Little is known about the magnetic resonance imaging (MRI) appearance of canine meniscal lesions. The aim of this study is to describe the MR appearance of meniscal lesions in dogs with experimentally induced cranial cruciate ligament (CCL) deficiency. The pilot study revealed dogs weighing approximately 10 kg to be too small for meniscal evaluation on low-field MRI. In the main study, dogs weighing approximately 35 kg were used. The left CCL was transected and low-field MRI was performed regularly until 13 months post-surgery. Normal menisci were defined as grade 0. Intrameniscal lesions not reaching any surface corresponded to grade 1 if focal and to grade 2 if linear or diffuse. Grade 3 lesions consisted in linear tears penetrating a meniscal surface. Grade 4 lesions included complex signal changes or meniscal distortion. Between 2 and 13 months post-surgery, all dogs developed grade 4 lesions in the medial meniscus. Most of them corresponded to longitudinal or bucket handle tears on arthroscopy and necropsy. Two dogs showed grade 3 lesions reaching the tibial surface of the lateral meniscus on MRI but not in arthroscopy. Such tears are difficult to evaluate arthroscopically; MRI provides more accurate information about the tibial meniscal surface. Grades 1 and 2 lesions could not be differentiated from presumably normal menisci with our imaging technique. An MRI grading system better adapted to canine lesions has yet to be developed. MRI is a helpful tool for the diagnosis of complete tears in the canine meniscus, especially in larger dogs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of the study was to examine the effect of low-frequency repetitive transcranial magnetic stimulation on saccade triggering. In five participants, a train of 600 pulses with a frequency of 1 Hz was applied over the right frontal eye field and--as control condition--over the vertex. After repetitive transcranial magnetic stimulation application, oculomotor performance was evaluated with an overlap paradigm. The results show that the repetitive transcranial magnetic stimulation effect was specific for frontal eye field stimulation. Saccade latencies were found to be increased bilaterally for several minutes after the stimulation, and the time course of recovery was different for the ipsilateral and contralateral sides. The results are discussed in the light of possible local and remote repetitive transcranial magnetic stimulation effects on the oculomotor network.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS: The objective of the present study was to investigate the relationship between extremely low-frequency magnetic field (ELF-MF) exposure and mortality from several neurodegenerative conditions in Swiss railway employees. METHODS: We studied a cohort of 20,141 Swiss railway employees with 464,129 person-years of follow-up between 1972 and 2002. For each individual, cumulative exposure was calculated from on-site measurements and modelling of past exposure. We compared cause-specific mortality in highly exposed train drivers (mean exposure: 21 microT) with less exposed occupational groups (for example station masters: 1 microT). RESULTS: The hazard ratio for train drivers compared to station masters was 1.96 [95% confidence interval (CI) = 0.98-3.92] for senile dementia and 3.15 (95% CI = 0.90-11.04) for Alzheimer's disease. For every 10 microT years of cumulative exposure senile dementia mortality increased by 5.7% (95% CI = 1.3-10.4), Alzheimer's disease by 9.4% (95% CI = 2.7-16.4) and amyotrophic lateral sclerosis by 2.1% (95% CI = -6.8 to 11.7). There was no evidence for an increase in mortality from Parkinson's disease and multiple sclerosis. CONCLUSIONS: This study suggests a link between exposure to ELF-MF and Alzheimer's disease and indicates that ELF-MF might act in later stages of the disease process.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS: To investigate the relationship between extremely low frequency magnetic field (ELF-MF) exposure and mortality from leukaemia and brain tumour in a cohort of Swiss railway workers. METHODS: 20,141 Swiss railway employees with 464,129 person-years of follow-up between 1972 and 2002 were studied. Mortality rates for leukaemia and brain tumour of highly exposed train drivers (21 muT average annual exposure) were compared with medium and low exposed occupational groups (i.e. station masters with an average exposure of 1 muT). In addition, individual cumulative exposure was calculated from on-site measurements and modelling of past exposures. RESULTS: The hazard ratio (HR) for leukaemia mortality of train drivers was 1.43 (95% CI 0.74 to 2.77) compared with station masters. For myeloid leukaemia the HR of train drivers was 4.74 (95% CI 1.04 to 21.60) and for Hodgkin's disease 3.29 (95% CI 0.69 to 15.63). Lymphoid leukaemia, non-Hodgkin's disease and brain tumour mortality were not associated with magnetic field exposure. Concordant results were obtained from analyses based on individual cumulative exposure. CONCLUSIONS: Some evidence of an exposure-response association was found for myeloid leukaemia and Hodgkin's disease, but not for other haematopoietic and lymphatic malignancies and brain tumours.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: Ultra-high-field whole-body systems (7.0 T) have a high potential for future human in vivo magnetic resonance imaging (MRI). In musculoskeletal MRI, biochemical imaging of articular cartilage may benefit, in particular. Delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) and T2 mapping have shown potential at 3.0 T. Although dGEMRIC, allows the determination of the glycosaminoglycan content of articular cartilage, T2 mapping is a promising tool for the evaluation of water and collagen content. In addition, the evaluation of zonal variation, based on tissue anisotropy, provides an indicator of the nature of cartilage ie, hyaline or hyaline-like articular cartilage.Thus, the aim of our study was to show the feasibility of in vivo dGEMRIC, and T2 and T2* relaxation measurements, at 7.0 T MRI; and to evaluate the potential of T2 and T2* measurements in an initial patient study after matrix-associated autologous chondrocyte transplantation (MACT) in the knee. MATERIALS AND METHODS: MRI was performed on a whole-body 7.0 T MR scanner using a dedicated circular polarization knee coil. The protocol consisted of an inversion recovery sequence for dGEMRIC, a multiecho spin-echo sequence for standard T2 mapping, a gradient-echo sequence for T2* mapping and a morphologic PD SPACE sequence. Twelve healthy volunteers (mean age, 26.7 +/- 3.4 years) and 4 patients (mean age, 38.0 +/- 14.0 years) were enrolled 29.5 +/- 15.1 months after MACT. For dGEMRIC, 5 healthy volunteers (mean age, 32.4 +/- 11.2 years) were included. T1 maps were calculated using a nonlinear, 2-parameter, least squares fit analysis. Using a region-of-interest analysis, mean cartilage relaxation rate was determined as T1 (0) for precontrast measurements and T1 (Gd) for postcontrast gadopentate dimeglumine [Gd-DTPA(2-)] measurements. T2 and T2* maps were obtained using a pixelwise, monoexponential, non-negative least squares fit analysis; region-of-interest analysis was carried out for deep and superficial cartilage aspects. Statistical evaluation was performed by analyses of variance. RESULTS: Mean T1 (dGEMRIC) values for healthy volunteers showed slightly different results for femoral [T1 (0): 1259 +/- 277 ms; T1 (Gd): 683 +/- 141 ms] compared with tibial cartilage [T1 (0): 1093 +/- 281 ms; T1 (Gd): 769 +/- 150 ms]. Global mean T2 relaxation for healthy volunteers showed comparable results for femoral (T2: 56.3 +/- 15.2 ms; T2*: 19.7 +/- 6.4 ms) and patellar (T2: 54.6 +/- 13.0 ms; T2*: 19.6 +/- 5.2 ms) cartilage, but lower values for tibial cartilage (T2: 43.6 +/- 8.5 ms; T2*: 16.6 +/- 5.6 ms). All healthy cartilage sites showed a significant increase from deep to superficial cartilage (P < 0.001). Within healthy cartilage sites in MACT patients, adequate values could be found for T2 (56.6 +/- 13.2 ms) and T2* (18.6 +/- 5.3 ms), which also showed a significant stratification. Within cartilage repair tissue, global mean values showed no difference, with 55.9 +/- 4.9 ms for T2 and 16.2 +/- 6.3 ms for T2*. However, zonal assessment showed only a slight and not significant increase from deep to superficial cartilage (T2: P = 0.174; T2*: P = 0.150). CONCLUSION: In vivo T1 dGEMRIC assessment in healthy cartilage, and T2 and T2* mapping in healthy and reparative articular cartilage, seems to be possible at 7.0 T MRI. For T2 and T2*, zonal variation of articular cartilage could also be evaluated at 7.0 T. This zonal assessment of deep and superficial cartilage aspects shows promising results for the differentiation of healthy and affected articular cartilage. In future studies, optimized protocol selection, and sophisticated coil technology, together with increased signal at ultra-high-field MRI, may lead to advanced biochemical cartilage imaging.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to investigate the effect of single-pulse transcranial magnetic stimulation on the triggering of saccades. The right frontal eye field was stimulated during modified gap and overlap paradigms with flashed presentation of the lateral visual target of 80 ms. In order to examine possible facilitating or inhibitory effects on saccade triggering, three different time intervals of stimulation were chosen, i.e. simultaneously with onset of the target, during the presentation and after target end. Stimulation applied simultaneously with target onset significantly decreased the latency of contralateral saccades in the gap but not in the overlap paradigm. Stimulation after target end significantly increased saccade latency for both sides in the gap paradigm and for the contralateral side in the overlap paradigm. Stimulation during presentation had no effect in either paradigm. The results show that, depending on the time interval and the paradigm tested, a facilitation or inhibition of saccade triggering can be achieved. The results are discussed in a context of two probable transcranial magnetic stimulation effects, a direct interference with the frontal eye field on the one hand and a remote interference with the superior colliculus on the other hand.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The study investigated the influence of double-pulse transcranial magnetic stimulation (dTMS) on memory-guided saccade triggering. Double pulses with interstimulus intervals (ISIs) of 35, 50, 65 or 80 ms were applied over the right frontal eye field (FEF) and as control over the occipital cortex. A significant dTMS effect was found exclusively for contralateral saccades; latency of memory-guided saccades was reduced after FEF stimulation with an ISI of 50 ms compared to latency without stimulation. This effect proved to be specific for the ISI of 50 ms over the FEF because control stimulation with the same ISI over the occipital cortex had no significant effect on latency of memory-guided saccades. The results of our study showed that, by using an appropriate ISI, dTMS is able to facilitate contralateral saccade triggering by stimulating the FEF. This suggests that TMS interferes specifically with saccade triggering mechanisms, probably by acting on presaccadic neurons of the FEF.