180 resultados para Magnetic Resonance Circuits (MRC)

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this prospective trial was to evaluate sensitivity and specificity of bright lumen magnetic resonance colonography (MRC) in comparison with conventional colonoscopy (CC). A total of 120 consecutive patients with clinical indications for CC were prospectively examined using MRC (1.5 Tesla) which was then followed by CC. Prior to MRC, the cleansed colon was filled with a gadolinium-water solution. A 3D GRE sequence was performed with the patient in the prone and supine position, each acquired during one breathhold period. After division of the colon into five segments, interactive data analysis was carried out using three-dimensional post-processing, including a virtual intraluminal view. The results of CC served as a reference standard. In all patients MRC was performed successfully and no complications occurred. Image quality was diagnostic in 92% (574/620 colonic segments). On a per-patient basis, the results of MRC were as follows: sensitivity 84% (95% CI 71.7-92.3%), specificity 97% (95% CI 89.0-99.6%). Five flat adenomas and 6/16 small polyps (< or =5 mm) were not identified by MRC. MRC offers high sensitivity and excellent specificity rates in patients with clinical indications for CC. Improved MRC techniques are needed to detect small polyps and flat adenomas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To assess magnetic resonance (MR)-colonography (MRC) for detection of colorectal lesions using two different T1w three-dimensional (3D)-gradient-recalled echo (GRE)-sequences and integrated parallel data acquisition (iPAT) at a 3.0 Tesla MR-unit. MATERIALS AND METHODS: In this prospective study, 34 symptomatic patients underwent dark lumen MRC at a 3.0 Tesla unit before conventional colonoscopy (CC). After colon distension with tap water, 2 high-resolution T1w 3D-GRE [3-dimensional fast low angle shot (3D-FLASH), iPAT factor 2 and 3D-volumetric interpolated breathhold examination (VIBE), iPAT 3] sequences were acquired without and after bolus injection of gadolinium. Prospective evaluation of MRC was performed. Image quality of the different sequences was assessed qualitatively and quantitatively. The findings of the same day CC served as standard of reference. RESULTS: MRC identified all polyps >5 mm (16 of 16) in size and all carcinomas (4 of 4) correctly. Fifty percent of the small polyps MRC. Diagnostic quality was excellent in 94% (384 of 408 colonic segments) using the 3D-FLASH and in 92% (376 of 408) for the VIBE. The 3D-FLASH sequence showed a 3-fold increase in signal-to-noise ratio (8 +/- 3.3 standard deviation (SD) in lesions without contrast enhancement (CE); 24.3 +/- 7.8 SD after CE). For the 3D-VIBE sequence, signal-to-noise ratio doubled in the detected lesions (147 +/- 54 SD without and 292 +/- 168 SD after CE). Although image quality was ranked lower in the VIBE, the image quality score of both sequences showed no statistical significant difference (chi > 0.6). CONCLUSIONS: MRC using 3D-GRE-sequences and iPAT is feasible at 3.0 T-systems. The high-resolution 3D-FLASH was slightly preferred over the 3D-VIBE because of better image quality, although both used sequences showed no statistical significant difference.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To characterise and quantify short-term changes in local inflammation using magnetic resonance imaging (MRI), and to correlate the findings with clinical disease activity in response to infliximab in patients with spondyloarthritis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To determine the potential benefit of combined respiratory-cardiac triggering for diffusion-weighted imaging (DWI) of kidneys compared to respiratory triggering alone (RT).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Patients with GH deficiency (GHD) are insulin resistant with an increase in visceral fat mass (FM). Whether this holds true when sedentary control subjects (CS) are matched for waist has not been documented. GH replacement therapy (GHRT) results in a decrease in FM. Whether the decrease in FM is mainly related to a reduction in visceral FM remains to be proven. The aim was to separately assess visceral and subcutaneous FM in relation to insulin resistance (IR) in GHD patients before and after GHRT and in sedentary CS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective was to report the ability of a magnetic resonance image to document the integrity of the obturator externus tendon after posterior hip dislocation as a potential predictor for preserved femoral head vascularity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to investigate whether T1-mapping of hip joint with intra-articular delayed gadolinium-enhanced magnetic resonance imaging (MRI) of cartilage (ia-dGEMRIC) is comparable to the already established intravenous (iv)-technique for assessing different grades of cartilage degeneration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To (1) establish the feasibility of texture analysis for the in vivo assessment of biochemical changes in meniscal tissue on delayed gadolinium-enhanced magnetic resonance imaging of cartilage (dGEMRIC), and (2) compare textural with conventional T1 relaxation time measurements calculated from dGEMRIC data ("T1(Gd) relaxation times").

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to assess the glycosaminoglycan (GAG) content in hip joint cartilage in mature hips with a history of slipped capital femoral epiphysis (SCFE) using delayed gadolinium-enhanced MRI of cartilage (dGEMRIC). METHODS: 28 young-adult subjects (32 hips) with a mean age of 23.8+/-4.0 years (range: 18.1-30.5 years) who were treated for mild or moderate SCFE in adolescence were included into the study. Hip function and clinical symptoms were evaluated with the Harris hip score (HHS) system at the time of MRI. Plain radiographic evaluation included Tonnis grading, measurement of the minimal joint space width (JSW) and alpha-angle measurement. The alpha-angle values were used to classify three sub-groups: group 1=subjects with normal femoral head-neck offset (alpha-angle <50 degrees ), group 2=subjects with mild offset decrease (alpha-angle 50 degrees -60 degrees ), and group 3=subjects with severe offset decrease (alpha-angle >60 degrees ). RESULTS: There was statistically significant difference noted for the T1(Gd) values, lateral and central, between group 1 and group 3 (p-values=0.038 and 0.041). The T1(Gd) values measured within the lateral portion were slightly lower compared with the T1(Gd) values measured within the central portion that was at a statistically significance level (p-value <0.001). HHS, Tonnis grades and JSW revealed no statistically significant difference. CONCLUSION: By using dGEMRIC in the mid-term follow-up of SCFE we were able to reveal degenerative changes even in the absence of joint space narrowing that seem to be related to the degree of offset pathology. The dGEMRIC technique may be a potential diagnostic modality in the follow-up evaluation of SCFE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim of this study was to assess the glycosaminoglycan content in hip joint cartilage in mature hips with a history of Legg-Calvé-Perthes (LCPD) disease using delayed gadolinium-enhanced magnetic resonance imaging of cartilage (dGEMRIC).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective To determine the prevalence of cam-type deformities on hip magnetic resonance imaging (MRI) in young males. Methods This was a population-based cross-sectional study in young asymptomatic male individuals who underwent clinical examination and completed a self-report questionnaire. A random sample of participants was invited for MRI of the hip. We graded the maximal offset at the femoral head–neck junction on radial sequences using grades from 0 to 3, where 0 = normal, 1 = possible, 2 = definite, and 3 = severe deformity. The prespecified main analyses were based on definite cam-type deformity grades 2 or 3. We estimated the prevalence of the cam-type deformity adjusted for the sampling process overall and according to the extent of internal rotation. Then we determined the location of the deformity on radial MRI sequences. Results A total of 1,080 subjects were included in the study and 244 asymptomatic males with a mean age of 19.9 years attended MRI. Sixty-seven definite cam-type deformities were detected. The adjusted overall prevalence was 24% (95% confidence interval [95% CI] 19–30%). The prevalence increased with decreasing internal rotation (P < 0.001 for trend). Among those with a clinically decreased internal rotation of <30°, the estimated prevalence was 48% (95% CI 37–59%). Sixty-one of 67 cam-type deformities were located in an anterosuperior position. Conclusion Cam-type deformities can be found on MRI in every fourth young asymptomatic male individual and in every second male with decreased internal rotation. The majority of deformities are located in an anterosuperior position.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Intramyocellular acetylcarnitine (IMAC) is involved in exercise-related fuel metabolism. It is not known whether levels of systemic glucose influence IMAC levels in type 1 diabetes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To propose the determination of the macromolecular baseline (MMBL) in clinical 1H MR spectra based on T(1) and T(2) differentiation using 2D fitting in FiTAID, a general Fitting Tool for Arrays of Interrelated Datasets.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Systolic right ventricular (RV) function is an important predictor in the course of various congenital and acquired heart diseases. Its practical determination by echocardiography remains challenging. We compared routine assessment of lateral tricuspid annular systolic motion velocity (TV(lat), cm/s) using pulsed-wave tissue Doppler imaging from the apical 4-chamber view with cardiac magnetic resonance (CMR) as reference method.