2 resultados para MALEIC-ACID

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Maleic acid (MA) is a common component of descaling products and is widely used in daily life. Accidental ingestion in relevant amounts does not play a major role in human beings; however, it seems to be highly toxic for dogs. It has been commonly used experimentally to induce Fanconi syndrome in dogs or small rodents. Two dogs were presented for acute kidney injury (AKI) after accidental ingestion of a descaling agent containing MA at an estimated amount of 70 mg/kg each. The third dog involved was euthanased by the referring veterinarian, and postmortem pathological analysis revealed severe acute tubular necrosis consistent with toxic nephropathy. The other dogs received symptomatic therapy for AKI including treatment with haemodialysis and showed complete normalisation of serum creatinine at a follow-up after five months. Renal damage can be very severe, but seems to be at least partially reversible and an attempt to treatment is warranted.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The use of capillary zone electrophoresis (CZE) with indirect absorbance detection for the analysis of ethyl sulfate (EtS) in serum and urine was investigated. EtS is a direct metabolite of ethanol employed as marker for recent alcohol consumption. Fused-silica capillaries of 60 cm total length were either coated with cetyltrimethylammonium bromide (CTAB, 50 microm I.D. capillary) or poly(diallyldimethylammonium chloride) (PDADMAC, 100 microm I.D. capillary) to allow CZE analyses to be performed with reversed polarity. At pH 2.2 with a maleic acid/phthalic acid background electrolyte, both approaches provided reliable EtS serum levels down to 0.2 mg L(-1) (1.6 microM) for the analysis of solid-phase extracts that were prepared after chloride precipitation. Analysis of urines diluted to a conductivity of 5 S m(-1) and analyzed in the two capillary formats resulted in limits of quantification (LOQs) of 2 and 1 mg L(-1), respectively. With urines adjusted to 10 S m(-1) via dilution or condensation, an LOQ of 0.6 mg L(-1) (4.8 microM) was obtained in the CTAB coated capillary whereas in the PDADMAC-coated capillary of equal length not all matrix components were resolved from EtS. The developed assays are robust and suitable to monitor EtS in samples of individuals who consumed as little as one standard drink of an alcoholic beverage containing about 14 g of ethanol.