100 resultados para Lung volume measurement

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Morphological changes in preterm infants with bronchopulmonary dysplasia (BPD) have functional consequences on lung volume, ventilation inhomogeneity and respiratory mechanics. Although some studies have shown lower lung volumes and increased ventilation inhomogeneity in BPD infants, conflicting results exist possibly due to differences in sedation and measurement techniques. METHODOLOGY/PRINCIPAL FINDINGS: We studied 127 infants with BPD, 58 preterm infants without BPD and 239 healthy term-born infants, at a matched post-conceptional age of 44 weeks during quiet natural sleep according to ATS/ERS standards. Lung function parameters measured were functional residual capacity (FRC) and ventilation inhomogeneity by multiple breath washout as well as tidal breathing parameters. Preterm infants with BPD had only marginally lower FRC (21.4 mL/kg) than preterm infants without BPD (23.4 mL/kg) and term-born infants (22.6 mL/kg), though there was no trend with disease severity. They also showed higher respiratory rates and lower ratios of time to peak expiratory flow and expiratory time (t(PTEF)/t(E)) than healthy preterm and term controls. These changes were related to disease severity. No differences were found for ventilation inhomogeneity. CONCLUSIONS: Our results suggest that preterm infants with BPD have a high capacity to maintain functional lung volume during natural sleep. The alterations in breathing pattern with disease severity may reflect presence of adaptive mechanisms to cope with the disease process.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Infants with chronic lung disease (CLD) have a capacity to maintain functional lung volume despite alterations to their lung mechanics. We hypothesize that they achieve this by altering breathing patterns and dynamic elevation of lung volume, leading to differences in the relationship between respiratory muscle activity, flow and lung volume. Lung function and transcutaneous electromyography of the respiratory muscles (rEMG) were measured in 20 infants with CLD and in 39 healthy age-matched controls during quiet sleep. We compared coefficient of variations (CVs) of rEMG and the temporal relationship of rEMG variables, to flow and lung volume [functional residual capacity (FRC)] between these groups. The time between the start of inspiratory muscle activity and the resulting flow (tria)--in relation to respiratory cycle time--was significantly longer in infants with CLD. Although FRC had similar associations with tria and postinspiratory activity (corrected for respiratory cycle time), the CV of the diaphragmatic rEMG was lower in CLD infants (22.6 versus 31.0%, p = 0.030). The temporal relationship of rEMG to flow and FRC and the loss of adaptive variability provide additional information on coping mechanisms in infants with CLD. This technique could be used for noninvasive bedside monitoring of CLD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

CBV is a vital perfusion parameter in estimating the viability of brain parenchyma (eg, in cases of ischemic stroke or after interventional vessel occlusion). Recent technologic advances allow parenchymal CBV imaging tableside in the angiography suite just before, during, or after an interventional procedure. The aim of this work was to analyze our preliminary clinical experience with this new imaging tool in different neurovascular interventions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The measurement of fluid volumes in cases of pericardial effusion is a necessary procedure during autopsy. With the increased use of virtual autopsy methods in forensics, the need for a quick volume measurement method on computed tomography (CT) data arises, especially since methods such as CT angiography can potentially alter the fluid content in the pericardium. We retrospectively selected 15 cases with hemopericardium, which underwent post-mortem imaging and autopsy. Based on CT data, the pericardial blood volume was estimated using segmentation techniques and downsampling of CT datasets. Additionally, a variety of measures (distances, areas and 3D approximations of the effusion) were examined to find a quick and easy way of estimating the effusion volume. Segmentation of CT images as shown in the present study is a feasible method to measure the pericardial fluid amount accurately. Downsampling of a dataset significantly increases the speed of segmentation without losing too much accuracy. Some of the other methods examined might be used to quickly estimate the severity of the effusion volumes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lung volume reduction surgery (LVRS) has been proposed for patients with severe emphysema to improve dyspnoea and pulmonary function. It is unknown, however, whether prognosis and pulmonary function in these patients can be improved compared to conservative treatment. The effect of LVRS and conservative therapy were compared prospectively in 57 patients with emphysema, who fulfilled the standard criteria for LVRS. The patients were divided into two groups according to their own decision. Patients in group 1 (n=29, eight females, mean+/-SEM 58.8+/-1.7 yrs, forced expiratory volume in one second (FEV1) 27.6+/-1.3% of the predicted value) underwent LVRS. Patients in group 2 (n=28, five females, 58.5+/-1.8 yrs, FEV1 30.8+/-1.4% pred) preferred to postpone LVRS. There were no significant differences in lung function between the two groups at baseline; however, there was a tendency towards better functional status in the control group. The control group had a better modified Medical Research Council (MMRC) dyspnea score (3.1+/-0.15 versus 3.5+/-0.1, p<0.04). Model-based comparisons were used to estimate the differences between the two groups over 18 months. Significant improvements were observed in the LVRS group compared to the control group in FEV1, total lung capacity (TLC), Residual volume (RV), MMRC dyspnea score and 6-min walking distance on all follow up visits. The estimated difference in FEV1 was 33% (95% confidence interval 13-58%; p>0.0001), in TLC 12.9% (7.9-18.8%; p>0.0001), in RV 60.9% 32.6-89.2%; p>0.0001), in 6-min walking distance 230 m (138-322 m; p<0.002) and in MMRC dyspnoea score 1.17 (0.79-1.55; p<0.0001). In conclusion, lung volume reduction surgery is more effective than conservative treatment for the improvement of dyspnoea, lung function and exercise capacity in selected patients with severe emphysema.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: We report mid-term results after 25 consecutive lung volume reduction operations (LVRS) for the treatment of severe dyspnea due to advanced emphysema. METHODS: Study design: patients were studied prospectively up to 12 months after surgery. Setting: preoperative evaluation, surgery and postoperative care took place in our university hospital. Patients: patient selection was based on severe dyspnea and airway obstruction despite optimal medical treatment, lung overinflation and completed rehabilitation programme. Patients with severe hypercarbia (PCO2>50 mmHg) were excluded. Nineteen rehabilitated patients who fulfilled our inclusion criteria but postponed or denied LVRS were followed up clinically. Interventions: LVRS was performed bilaterally in 22 patients (median sternotomy) and unilaterally in 3 patients (limited thoracotomy). Measures: Outcome was measured by dyspnea evaluation, 6-minute-walking distance and pulmonary function tests. RESULTS: Twelve months postoperatively dyspnea and mobility improved significantly (MRC score from 3.3+/-0.7 to 2.12+/-0.8, 6-min-walk from 251+/-190 to 477+/-189 m). These results were superior compared to the results of the conservatively treated patients. Significant improvement could also be documented in airway obstruction (FEV1 from 960+/-369 to 1438+/-610 ml) and overinflation (TLC from 133+/-14 to 118+/-21% predicted and RV from 280+/-56 to 186+/-59% predicted). CONCLUSIONS: LVRS is an effective and promising treatment option for selected patients with end-stage emphysema and could be offered as an alternative and / or bridge to lung transplantation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To report preliminary results with a new surgical method of treating terminal emphysema by bilateral reduction of lung volume. PATIENTS AND METHODS: In a prospective study, the results obtained with the first 20 consecutive patients (mean FEV1: 590 +/- 180 ml) who underwent operative reduction of lung volume were recorded. 19 of the 20 patients had required continuous oxygen supply. RESULTS: The patients were extubated 8.5 +/- 6 h postoperatively; thoracic drainage was removed after 9 +/- 6 days. The degree of dyspnoea was decreased in all patients (3.5 +/- 0.5 vs 0.5 +/- 0.1). Significant reduction of overinflation occurred soon after the operation (residual volume 273 +/- 125 to 201 +/- 107% of normal; total capacity from 142 +/- 18 to 109 +/- 22% of normal), as well as reduction in the degree of obstruction (FEV1 from 18 +/- 6 to 24 +/- 7% of normal; for each, P < 0.05). One patient died 3 weeks post-operatively of Candida infection. CONCLUSION: The method looks promising for the treatment of selected patients and may thus provide an alternative to lung transplantation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Lung volume reduction (LVR) surgery is an effective and organ-preserving treatment option for patients suffering from severe dyspnea due to endstage emphysema. METHOD: Resection of functionally inactive lung parenchyma reduces over-inflation and restores the elastic recoil of the lungs. Thus it results in improvement of dyspnea, mobility and pulmonary function. Patient selection is crucial. Of simliar importance is pulmonary rehabilitation, as well as sufficient expertise in the treatment of endstage chronic respiratory failure. RESULTS AND CONCLUSION: The in-hospital morbidity and mortality after LVR are acceptable (0 to 5%) and the good results seem to last at least 18 to 24 months. LVR can be offered to selected patients either as an alternative or as bridge to lung transplantation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coronary artery disease is prevalent in patients who have severe emphysema and who are being considered for lung volume reduction surgery (LVRS). Significant valvular heart diseases may also coexist in these patients. Few thoracic surgeons have performed LVRS in patients who have severe cardiac diseases. Conversely, few cardiac surgeons have been willing to undertake major cardiac surgery in patients who have severe emphysema. This report reviews the evidence regarding combined cardiac surgery and LVRS to determine the optimal management strategy for patients who have severe emphysema and who are suitable for LVRS, but who also have coexisting significant cardiac diseases that are operable.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pulmonary emphysema causes decrease in lung function due to irreversible dilatation of intrapulmonary air spaces, which is linked to high morbidity and mortality. Lung volume reduction (LVR) is an invasive therapeutical option for pulmonary emphysema in order to improve ventilation mechanics. LVR can be carried out by lung resection surgery or different minimally invasive endoscopical procedures. All LVR-options require mandatory preinterventional evaluation to detect hyperinflated dysfunctional lung areas as target structures for treatment. Quantitative computed tomography can determine the volume percentage of emphysematous lung and its topographical distribution based on the lung's radiodensity. Modern techniques allow for lobebased quantification that facilitates treatment planning. Clinical tests still play the most important role in post-interventional therapy monitoring, but CT is crucial in the detection of postoperative complications and foreshadows the method's high potential in sophisticated experimental studies. Within the last ten years, LVR with endobronchial valves has become an extensively researched minimally-invasive treatment option. However, this therapy is considerably complicated by the frequent occurrence of functional interlobar shunts. The presence of "collateral ventilation" has to be ruled out prior to valve implantations, as the presence of these extraanatomical connections between different lobes may jeopardize the success of therapy. Recent experimental studies evaluated the automatic detection of incomplete lobar fissures from CT scans, because they are considered to be a predictor for the existence of shunts. To date, these methods are yet to show acceptable results. KEY POINTS Today, surgical and various minimal invasive methods of lung volume reduction are in use. Radiological and nuclear medical examinations are helpful in the evaluation of an appropriate lung area. Imaging can detect periinterventional complications. Reduction of lung volume has not yet been conclusively proven to be effective and is a therapeutical option with little scientific evidence.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND A precise detection of volume change allows for better estimating the biological behavior of the lung nodules. Postprocessing tools with automated detection, segmentation, and volumetric analysis of lung nodules may expedite radiological processes and give additional confidence to the radiologists. PURPOSE To compare two different postprocessing software algorithms (LMS Lung, Median Technologies; LungCARE®, Siemens) in CT volumetric measurement and to analyze the effect of soft (B30) and hard reconstruction filter (B70) on automated volume measurement. MATERIAL AND METHODS Between January 2010 and April 2010, 45 patients with a total of 113 pulmonary nodules were included. The CT exam was performed on a 64-row multidetector CT scanner (Somatom Sensation, Siemens, Erlangen, Germany) with the following parameters: collimation, 24x1.2 mm; pitch, 1.15; voltage, 120 kVp; reference tube current-time, 100 mAs. Automated volumetric measurement of each lung nodule was performed with the two different postprocessing algorithms based on two reconstruction filters (B30 and B70). The average relative volume measurement difference (VME%) and the limits of agreement between two methods were used for comparison. RESULTS At soft reconstruction filters the LMS system produced mean nodule volumes that were 34.1% (P < 0.0001) larger than those by LungCARE® system. The VME% was 42.2% with a limit of agreement between -53.9% and 138.4%.The volume measurement with soft filters (B30) was significantly larger than with hard filters (B70); 11.2% for LMS and 1.6% for LungCARE®, respectively (both with P < 0.05). LMS measured greater volumes with both filters, 13.6% for soft and 3.8% for hard filters, respectively (P < 0.01 and P > 0.05). CONCLUSION There is a substantial inter-software (LMS/LungCARE®) as well as intra-software variability (B30/B70) in lung nodule volume measurement; therefore, it is mandatory to use the same equipment with the same reconstruction filter for the follow-up of lung nodule volume.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES The aim of this phantom study was to minimize the radiation dose by finding the best combination of low tube current and low voltage that would result in accurate volume measurements when compared to standard CT imaging without significantly decreasing the sensitivity of detecting lung nodules both with and without the assistance of CAD. METHODS An anthropomorphic chest phantom containing artificial solid and ground glass nodules (GGNs, 5-12 mm) was examined with a 64-row multi-detector CT scanner with three tube currents of 100, 50 and 25 mAs in combination with three tube voltages of 120, 100 and 80 kVp. This resulted in eight different protocols that were then compared to standard CT sensitivity (100 mAs/120 kVp). For each protocol, at least 127 different nodules were scanned in 21-25 phantoms. The nodules were analyzed in two separate sessions by three independent, blinded radiologists and computer-aided detection (CAD) software. RESULTS The mean sensitivity of the radiologists for identifying solid lung nodules on a standard CT was 89.7% ± 4.9%. The sensitivity was not significantly impaired when the tube and current voltage were lowered at the same time, except at the lowest exposure level of 25 mAs/80 kVp [80.6% ± 4.3% (p = 0.031)]. Compared to the standard CT, the sensitivity for detecting GGNs was significantly lower at all dose levels when the voltage was 80 kVp; this result was independent of the tube current. The CAD significantly increased the radiologists' sensitivity for detecting solid nodules at all dose levels (5-11%). No significant volume measurement errors (VMEs) were documented for the radiologists or the CAD software at any dose level. CONCLUSIONS Our results suggest a CT protocol with 25 mAs and 100 kVp is optimal for detecting solid and ground glass nodules in lung cancer screening. The use of CAD software is highly recommended at all dose levels.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

One key problem in modern medical imaging is linking measured data and actual physiological quantities. In this article we derive such a link between the electrical bioimpedance of lung parenchyma, which can be measured by electrical impedance tomography (EIT), and the magnitude of regional ventilation, a key to understanding lung mechanics and developing novel protective ventilation strategies. Two rat-derived three-dimensional alveolar microstructures obtained from synchrotron-based x-ray tomography are each exposed to a constant potential difference for different states of ventilation in a finite element simulation. While the alveolar wall volume remains constant during stretch, the enclosed air volume varies, similar to the lung volume during ventilation. The enclosed air, serving as insulator in the alveolar ensemble, determines the resulting current and accordingly local tissue bioimpedance. From this we can derive a relationship between lung tissue bioimpedance and regional alveolar ventilation. The derived relationship shows a linear dependence between air content and tissue impedance and matches clinical data determined from a ventilated patient at the bedside.