159 resultados para Lumbar spine, Interbody fusion, Cage, Pedicle screw fixation, Strain, Biomechanics

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Autogenous iliac crest has long served as the gold standard for anterior lumbar arthrodesis although added morbidity results from the bone graft harvest. Therefore, femoral ring allograft, or cages, have been used to decrease the morbidity of iliac crest bone harvesting. More recently, an experimental study in the animal showed that harvesting local bone from the anterior vertebral body and replacing the void by a radio-opaque beta-tricalcium phosphate plug was a valid concept. However, such a concept precludes theoretically the use of posterior pedicle screw fixation. At one institution a consecutive series of 21 patients underwent single- or multiple-level circumferential lumbar fusion with anterior cages and posterior pedicle screws. All cages were filled with cancellous bone harvested from the adjacent vertebral body, and the vertebral body defect was filled with a beta-tricalcium phosphate plug. The indications for surgery were failed conservative treatment of a lumbar degenerative disc disease or spondylolisthesis. The purpose of this study, therefore, was to report on the surgical technique, operative feasibility, safety, benefits, and drawbacks of this technique with our primary clinical experience. An independent researcher reviewed all data that had been collected prospectively from the onset of the study. The average age of the patients was 39.9 (26-57) years. Bone grafts were successfully harvested from 28 vertebral bodies in all but one patient whose anterior procedure was aborted due to difficulty in freeing the left common iliac vein. This case was converted to a transforaminal interbody fusion (TLIF). There was no major vascular injury. Blood loss of the anterior procedure averaged 250 ml (50-350 ml). One tricalcium phosphate bone plug was broken during its insertion, and one endplate was broken because of wrong surgical technique, which did not affect the final outcome. One patient had a right lumbar plexopathy that was not related to this special technique. There was no retrograde ejaculation, infection or pseudoarthrosis. One patient experienced a deep venous thrombosis. At the last follow up (mean 28 months) all patients had a solid lumbar spine fusion. At the 6-month follow up, the pain as assessed on the visual analog scale (VAS) decreased from 6.9 to 4.5 (33% decrease), and the Oswestry disability index (ODI) reduced from 48.0 to 31.7 with a 34% reduction. However, at 2 years follow up there was a trend for increase in the ODI (35) and VAS (5). The data in this study suggest that harvesting a cylinder of autograft from the adjacent vertebral body is safe and efficient. Filling of the void defect with a beta-tricalcium phosphate plug does not preclude the use of posterior pedicle screw stabilization.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

One goal of interbody fusion is to increase the height of the degenerated disc space. Interbody cages in particular have been promoted with the claim that they can maintain the disc space better than other methods. There are many factors that can affect the disc height maintenance, including graft or cage design, the quality of the surrounding bone and the presence of supplementary posterior fixation. The present study is an in vitro biomechanical investigation of the compressive behaviour of three different interbody cage designs in a human cadaveric model. The effect of bone density and posterior instrumentation were assessed. Thirty-six lumbar functional spinal units were instrumented with one of three interbody cages: (1) a porous titanium implant with endplate fit (Stratec), (2) a porous, rectangular carbon-fibre implant (Brantigan) and (3) a porous, cylindrical threaded implant (Ray). Posterior instrumentation (USS) was applied to half of the specimens. All specimens were subjected to axial compression displacement until failure. Correlations between both the failure load and the load at 3 mm displacement with the bone density measurements were observed. Neither the cage design nor the presence of posterior instrumentation had a significant effect on the failure load. The loads at 3 mm were slightly less for the Stratec cage, implying lower axial stiffness, but were not different with posterior instrumentation. The large range of observed failure loads overlaps the potential in vivo compressive loads, implying that failure of the bone-implant interface may occur clinically. Preoperative measurements of bone density may be an effective tool to predict settling around interbody cages.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE Currently, the diagnosis of pedicle screw (PS) loosening is based on a subjectively assessed halo sign, that is, a radiolucent line around the implant wider than 1 mm in plain radiographs. We aimed at development and validation of a quantitative method to diagnose PS loosening on radiographs. METHODS Between 11/2004 and 1/2010 36 consecutive patients treated with thoraco-lumbar spine fusion with PS instrumentation without PS loosening were compared with 37 other patients who developed a clinically manifesting PS loosening. Three different angles were measured and compared regarding their capability to discriminate the loosened PS over the postoperative course. The inter-observer invariance was tested and a receiver operating characteristics curve analysis was performed. RESULTS The angle measured between the PS axis and the cranial endplate was significantly different between the early and all later postoperative images. The Spearman correlation coefficient for the measurements of two observers at each postoperative time point ranged between 0.89 at 2 weeks to 0.94 at 2 months and 1 year postoperative. The angle change of 1.9° between immediate postoperative and 6-month postoperative was 75% sensitive and 89% specific for the identification of loosened screws (AUC = 0.82). DISCUSSION The angle between the PS axis and the cranial endplate showed good ability to change in PS loosening. A change of this angle of at least 2° had a relatively high sensitivity and specificity to diagnose screw loosening.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

STUDY DESIGN.: Cadaver study. OBJECTIVE.: To determine bone strength in vertebrae by measuring peak breakaway torque or indentation force using custom-made pedicle probes. SUMMARY OF BACKGROUND DATA.: Screw performance in dorsal spinal instrumentation is dependent on bone quality of the vertebral body. To date no intraoperative measuring device to validate bone strength is available. Destructive testing may predict bone strength in transpedicular instrumentations in osteoporotic vertebrae. Insertional torque measurements showed varying results. METHODS.: Ten human cadaveric vertebrae were evaluated for bone mineral density (BMD) measurements by quantitative computed tomography. Peak torque and indentation force of custom-made probes as a measure for mechanical bone strength were assessed via a transpedicular approach. The results were correlated to regional BMD and to biomechanical load testing after pedicle screw implementation. RESULTS.: Both methods generated a positive correlation to failure load of the respective vertebrae. The correlation of peak breakaway torque to failure load was r = 0.959 (P = 0.003), therewith distinctly higher than the correlation of indentation force to failure load, which was r = 0.690 (P = 0.040). In predicting regional BMD, measurement of peak torque also performed better than that of indentation force (r = 0.897 [P = 0.002] vs. r = 0.777 [P = 0.017]). CONCLUSION.: Transpedicular measurement of peak breakaway torque is technically feasible and predicts reliable local bone strength and implant failure for dorsal spinal instrumentations in this experimental setting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pedicle hooks which are used as an anchorage for posterior spinal instrumentation may be subjected to considerable three-dimensional forces. In order to achieve stronger attachment to the implantation site, hooks using screws for additional fixation have been developed. The failure loads and mechanisms of three such devices have been experimentally determined on human thoracic vertebrae: the Universal Spine System (USS) pedicle hook with one screw, a prototype pedicle hook with two screws and the Cotrel-Dubousset (CD) pedicle hook with screw. The USS hooks use 3.2-mm self-tapping fixation screws which pass into the pedicle, whereas the CD hook is stabilised with a 3-mm set screw pressing against the superior part of the facet joint. A clinically established 5-mm pedicle screw was tested for comparison. A matched pair experimental design was implemented to evaluate these implants in constrained (series I) and rotationally unconstrained (series II) posterior pull-out tests. In the constrained tests the pedicle screw was the strongest implant, with an average pull-out force of 1650 N (SD 623 N). The prototype hook was comparable, with an average failure load of 1530 N (SD 414 N). The average pull-out force of the USS hook with one screw was 910 N (SD 243 N), not significantly different to the CD hook's average failure load of 740 N (SD 189 N). The result of the unconstrained tests were similar, with the prototype hook being the strongest device (average 1617 N, SD 652 N). However, in this series the difference in failure load between the USS hook with one screw and the CD hook was significant. Average failure loads of 792 N (SD 184 N) for the USS hook and 464 N (SD 279 N) for the CD hook were measured. A pedicular fracture in the plane of the fixation screw was the most common failure mode for USS hooks.(ABSTRACT TRUNCATED AT 250 WORDS)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Current demographic changes are characterized by population aging, such that the surgical treatment of degenerative spine conditions in the elderly is gaining increasing relevance. However, there is a general reluctance to consider spinal fusion procedures in this patient age group due to the increased likelihood of complications. The aim of this study was to assess the patient-rated outcome and complication rates associated with lumbar fusion procedures in three different age groups. Methods: This was a retrospective analysis of prospectively collected data from consecutive patients who underwent first-time, one to three level posterior instrumented fusion between 2004 and 2011, due to degenerative disease of the lumbar spine. Data were obtained from our Spine Surgery Outcomes Database (linked to the International Spine Tango Register). Before surgery, patients completed the multidimensional Core Outcome Measures Index (COMI), and at 3 and 12 months after surgery they completed the COMI and rated the Global Treatment Outcome (GTO) and their satisfaction with care. Patients were divided into three groups according to their age: younger (≥50y <65y; n = 317), older (≥65y <80y; n = 350), and geriatric (≥ 80y; n = 40). Results: 707 consecutive patients were included. The preoperative comorbidity status differed significantly (p < 0.0001) between the age groups, with the highest scores in the geriatric group. General medical complications during surgery were lower in the younger age group (7%) than in the older (13.4%; p = 0.006) and geriatric groups (17.5%; p = 0.007). Duration of hospital stay was longer (p = 0.006) in the older group (10.8 ± 3.7 days) than the younger (10.0 ± 3.6 days) group. There were no significant group differences (p>0.05) for any of the COMI domains covering pain, function, symptom specific well-being, general quality of life, and social and work disability at either 3 months’ or 12 months’ follow-up. Similarly, there were no differences (p>0.05) between the age groups for GTO and patient-rated satisfaction at either follow-up. Conclusions: Preoperative comorbidity and general medical complications during lumbar fusion for degenerative disorders of the lumbar spine are both greater in geriatric patients than in younger patients. However, patient-rated outcome is as good in the elderly as it is in younger age groups. These data suggest that geriatric age per se is not a contraindication to instrumented fusion for lumbar degenerative disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

STUDY DESIGN Single centre retrospective study of prospectively collected data, nested within the Eurospine Spine Tango data acquisition system. OBJECTIVE The aim of this study was to assess the patient-rated outcome and complication rates associated with lumbar fusion procedures in three different age groups. SUMMARY OF BACKGROUND DATA There is a general reluctance to consider spinal fusion procedures in elderly patients due to the increased likelihood of complications. METHODS Before and at 3, 12, and 24 months after surgery, patients completed the multidimensional Core Outcome Measures Index (COMI). At the 3-, 12-, and 24-month follow-ups they also rated the Global Treatment Outcome (GTO) and their satisfaction with care. Patients were divided into three age groups: younger (≥50y < 65y; n = 317), older (≥65y < 80y; n = 350), and geriatric (≥ 80y; n = 40). RESULTS 707 consecutive patients were included. The preoperative comorbidity status differed significantly (p < 0.0001) between the age groups, with the highest scores in the geriatric group. Medical complications during surgery were lower in the younger age group (7%) than in the older (13.4%; p = 0.006) and geriatric groups (17.5%; p = 0.007); surgical complications tended to be higher in the elderly group (younger, 6.3%; older, 6.0%; geriatric, 15.0%; p = 0.09). There were no significant group differences (p > 0.05) for the scores on any of the COMI domains, GTO, or patient-rated satisfaction at either 3-, 12-, and 24-months follow-up. CONCLUSIONS Despite greater comorbidity and complication rates in geriatric patients, the patient-rated outcome was as good in the elderly as it was in younger age groups up to two years after surgery. These data indicate that geriatric age needs careful consideration of associated risks but is not per se a contraindication for fusion for lumbar degenerative disease. LEVEL OF EVIDENCE 4.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND CONTEXT Several randomized controlled trials (RCTs) have compared patient outcomes of anterior (cervical) interbody fusion (AIF) with those of total disc arthroplasty (TDA). Because RCTs have known limitations with regard to their external validity, the comparative effectiveness of the two therapies in daily practice remains unknown. PURPOSE This study aimed to compare patient-reported outcomes after TDA versus AIF based on data from an international spine registry. STUDY DESIGN AND SETTING A retrospective analysis of registry data was carried out. PATIENT SAMPLE Inclusion criteria were degenerative disc or disc herniation of the cervical spine treated by single-level TDA or AIF, no previous surgery, and a Core Outcome Measures Index (COMI) completed at baseline and at least 3 months' follow-up. Overall, 987 patients were identified. OUTCOME MEASURES Neck and arm pain relief and COMI score improvement were the outcome measures. METHODS Three separate analyses were performed to compare TDA and AIF surgical outcomes: (1) mimicking an RCT setting, with admission criteria typical of those in published RCTs, a 1:1 matched analysis was carried out in 739 patients; (2) an analysis was performed on 248 patients outside the classic RCT spectrum, that is, with one or more typical RCT exclusion criteria; (3) a subgroup analysis of all patients with additional follow-up longer than 2 years (n=149). RESULTS Matching resulted in 190 pairs with an average follow-up of 17 months that had no residual significant differences for any patient characteristics. Small but statistically significant differences in outcome were observed in favor of TDA, which are potentially clinically relevant. Subgroup analyses of atypical patients and of patients with longer-term follow-up showed no significant differences in outcome between the treatments. CONCLUSIONS The results of this observational study were in accordance with those of the published RCTs, suggesting substantial pain reduction both after AIF and TDA, with slightly greater benefit after arthroplasty. The analysis of atypical patients suggested that, in patients outside the spectrum of clinical trials, both surgical interventions appeared to work to a similar extent to that shown for the cohort in the matched study. Also, in the longer-term perspective, both therapies resulted in similar benefits to the patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND CONTEXT: Closed reduction and internal fixation by an anterior approach is an established option for operative treatment of displaced Type II odontoid fractures. In elderly patients, however, inadequate screw purchase in osteoporotic bone can result in severe procedure-related complications. PURPOSE: To improve the stability of odontoid fracture screw fixation in the elderly using a new technique that includes injection of polymethylmethacrylat (PMMA) cement into the C2 body. STUDY DESIGN: Retrospective review of hospital and outpatient records as well as radiographs of elderly patients treated in a university hospital department of orthopedic surgery. PATIENT SAMPLE: Twenty-four elderly patients (8 males and 16 females; mean age, 81 years; range, 62-98 years) with Type II fractures of the dens. OUTCOME MEASURES: Complications, cement leakage (symptomatic/asymptomatic), operation time, loss of reduction, pseudarthrosis and revision surgery, patient complaints, return to normal activities, and signs of neurologic complications were all documented. METHODS: After closed reduction and anterior approach to the inferior border of C2, a guide wire is advanced to the tip of the odontoid under biplanar fluoroscopic control. Before the insertion of one cannulated, self-drilling, short thread screws, a 12 gauge Yamshidi cannula is inserted from anterior and 1 to 3 mL of high-viscosity PMMA cement is injected into the anteroinferior portion of the C2 body. During polymerization of the cement, the screws are further inserted using a lag-screw compression technique. The cervical spine then is immobilized with a soft collar for 8 weeks postoperatively. RESULTS: Anatomical reduction of the dens was achieved in all 24 patients. Mean operative time was 64 minutes (40-90 minutes). Early loss of reduction occurred in three patients, but revision surgery was indicated in only one patient 2 days after primary surgery. One patient died within the first eight postoperative weeks, one within 3 months after surgery. In five patients, asymptomatic cement leakage was observed (into the C1-C2 joint in three patients, into the fracture in two). Conventional radiologic follow-up at 2 and 6 months confirmed anatomical healing in 16 of the19 patients with complete follow-up. In two patients, the fractures healed in slight dorsal angulation; one patient developed a asymptomatic pseudarthrosis. All patients were able to resume their pretrauma level of activity. CONCLUSIONS: Cement augmentation of the screw in Type II odontoid fractures in elderly patients is technically feasible in a clinical setting with a low complication rate. This technique may improve screw purchase, especially in the osteoporotic C2 body.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Twenty-eight feline pelves (56 hemipelves) were examined in order to identify the location for optimal sacroiliac screw placement in sacroiliac fracture-luxation repair. A drill hole was started on the median plane of the hemipelvis in the centre of the body of the first sacral segment until it penetrated the lateral cortex of the ilial wing, thus providing optimal drill hole placement. The position of the drill hole on the articular surface of the sacral wing and on the lateral surface of the ilial wing was measured. The distance of the drill hole from the cranial margin of the sacral wing was 51% of sacral wing length, just cranial to the crescent shaped hyaline cartilage. The distance from the dorsal margin was 47% of sacral wing height. The drill bit direction has to be adjusted to the cranio-caudal inclination (range 10° to 29°) and dorso-ventral inclination (range 2° to 25°) of the sacral wing. A notch in the cranial edge of the sacral wing was present, with variable position, in 34% of the specimens and is consequently not a useful landmark for sacroiliac screw placement. The drill hole on the lateral surface of the ilium was located in craniocaudal direction at a distance of 69% of sacral tuber length, measured from the cranial dorsal iliac spine. The dorso-ventral position of the drill hole was at a distance of 52% of ilial wing height measured from the sacral tuber. The ventral gluteal line, present in 93% of the cases, is a useful landmark to locate optimal screw hole position on the ilial wing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION Spinal disc herniation, lumbar spinal stenosis and spondylolisthesis are known to be leading causes of lumbar back pain. The cost of low back pain management and related operations are continuously increasing in the healthcare sector. There are many studies regarding complications after spine surgery but little is known about the factors predicting the length of stay in hospital. The purpose of this study was to identify these factors in lumbar spine surgery in order to adapt the postoperative treatment. MATERIAL AND METHODS The current study was carried out as a post hoc analysis on the basis of the German spine registry. Patients who underwent lumbar spine surgery by posterior surgical access and with posterior fusion and/or rigid stabilization, whereby procedures with dynamic stabilization were excluded. Patient characteristics were tested for association with length of stay (LOS) using bivariate and multivariate analyses. RESULTS A total of 356 patients met the inclusion criteria. The average age of all patients was 64.6 years and the mean LOS was 11.9 ± 6.0 days with a range of 2-44 days. Independent factors that were influencing LOS were increased age at the time of surgery, higher body mass index, male gender, blood transfusion of 1-2 erythrocyte concentrates and the presence of surgical complications. CONCLUSION Identification of predictive factors for prolonged LOS may allow for estimation of patient hospitalization time and for optimization of postoperative care. In individual cases this may result of a reduction in the LOS.