8 resultados para Low cost analog test
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Liver-on-chip systems are widely seen as having the potential to replace animal testing for long-term liver toxicity assessments. However, such systems necessitate solutions, such as electrochemical microsensors, to provide information about the cells exposed to chemical compounds in a confined space. This study describes the development of microsensors for the detection of alanine-aminotransferase (ALT), an intracellular enzyme found in hepatocytes, for monitoring the viability of in-vitro hepatic cell cultures. The electrochemical sensors were developed by using screen printed electrodes functionalized by drop-casting. These technologies are intended to produce disposable and low-cost sensors that can easily be exchanged once their performance is degraded. The sensors are capable of measuring ALT in a microfluidic environment through the detection of changes in glutamate concentration. The microsensors were found to be stable for more than 60 days and were successfully tested using hepatocellular lysates to assess their capability to quantify ALT activity in a hepatic cell culture. These results open the way to their integration in liver bioreactors to assess hepatocellular toxicity in-vitro.
Resumo:
BACKGROUND: Virtual reality testing of everyday activities is a novel type of computerized assessment that measures cognitive, executive, and motor performance as a screening tool for early dementia. This study used a virtual reality day-out task (VR-DOT) environment to evaluate its predictive value in patients with mild cognitive impairment (MCI). METHODS: One hundred thirty-four patients with MCI were selected and compared with 75 healthy control subjects. Participants received an initial assessment that included VR-DOT, a neuropsychological evaluation, magnetic resonance imaging (MRI) scan, and event-related potentials (ERPs). After 12 months, participants were assessed again with MRI, ERP, VR-DOT, and neuropsychological tests. RESULTS: At the end of the study, we differentiated two subgroups of patients with MCI according to their clinical evolution from baseline to follow-up: 56 MCI progressors and 78 MCI nonprogressors. VR-DOT performance profiles correlated strongly with existing predictive biomarkers, especially the ERP and MRI biomarkers of cortical thickness. CONCLUSIONS: Compared with ERP, MRI, or neuropsychological tests alone, the VR-DOT could provide additional predictive information in a low-cost, computerized, and noninvasive way.
Resumo:
A nonfluorescent low-cost, low-density oligonucleotide array was designed for detecting the whole coronavirus genus after reverse transcription (RT)-PCR. The limit of detection was 15.7 copies/reaction. The clinical detection limit in patients with severe acute respiratory syndrome was 100 copies/sample. In 39 children suffering from coronavirus 229E, NL63, OC43, or HKU1, the sensitivity was equal to that of individual real-time RT-PCRs.
Resumo:
The resting ECG is a safe, low cost and widely available in the clinical investigation of several cardiac symptoms. However, there is controversy regarding the use as a screening tool or routine cardiovascular (CV) risk assessment test among healthy asymptomatic adults. Two recent studies reported that ECG adds supplemental information in the estimation of coronary artery disease (CAD) risk in asymptomatic patients, especially in those with intermediate risk. However, we currently need more data on the impact of ECG on the prevention of clinical CV outcomes, especially in a randomized clinical trial, and on additional costs of testing and treatment. For the time being, routine ECG testing is not recommended for the prevention of CV events among healthy asymptomatic adults.
Resumo:
BACKGROUND The cost-effectiveness of routine viral load (VL) monitoring of HIV-infected patients on antiretroviral therapy (ART) depends on various factors that differ between settings and across time. Low-cost point-of-care (POC) tests for VL are in development and may make routine VL monitoring affordable in resource-limited settings. We developed a software tool to study the cost-effectiveness of switching to second-line ART with different monitoring strategies, and focused on POC-VL monitoring. METHODS We used a mathematical model to simulate cohorts of patients from start of ART until death. We modeled 13 strategies (no 2nd-line, clinical, CD4 (with or without targeted VL), POC-VL, and laboratory-based VL monitoring, with different frequencies). We included a scenario with identical failure rates across strategies, and one in which routine VL monitoring reduces the risk of failure. We compared lifetime costs and averted disability-adjusted life-years (DALYs). We calculated incremental cost-effectiveness ratios (ICER). We developed an Excel tool to update the results of the model for varying unit costs and cohort characteristics, and conducted several sensitivity analyses varying the input costs. RESULTS Introducing 2nd-line ART had an ICER of US$1651-1766/DALY averted. Compared with clinical monitoring, the ICER of CD4 monitoring was US$1896-US$5488/DALY averted and VL monitoring US$951-US$5813/DALY averted. We found no difference between POC- and laboratory-based VL monitoring, except for the highest measurement frequency (every 6 months), where laboratory-based testing was more effective. Targeted VL monitoring was on the cost-effectiveness frontier only if the difference between 1st- and 2nd-line costs remained large, and if we assumed that routine VL monitoring does not prevent failure. CONCLUSION Compared with the less expensive strategies, the cost-effectiveness of routine VL monitoring essentially depends on the cost of 2nd-line ART. Our Excel tool is useful for determining optimal monitoring strategies for specific settings, with specific sex-and age-distributions and unit costs.
Resumo:
BACKGROUND Potentially avoidable risk factors continue to cause unnecessary disability and premature death in older people. Health risk assessment (HRA), a method successfully used in working-age populations, is a promising method for cost-effective health promotion and preventive care in older individuals, but the long-term effects of this approach are unknown. The objective of this study was to evaluate the effects of an innovative approach to HRA and counselling in older individuals for health behaviours, preventive care, and long-term survival. METHODS AND FINDINGS This study was a pragmatic, single-centre randomised controlled clinical trial in community-dwelling individuals aged 65 y or older registered with one of 19 primary care physician (PCP) practices in a mixed rural and urban area in Switzerland. From November 2000 to January 2002, 874 participants were randomly allocated to the intervention and 1,410 to usual care. The intervention consisted of HRA based on self-administered questionnaires and individualised computer-generated feedback reports, combined with nurse and PCP counselling over a 2-y period. Primary outcomes were health behaviours and preventive care use at 2 y and all-cause mortality at 8 y. At baseline, participants in the intervention group had a mean ± standard deviation of 6.9 ± 3.7 risk factors (including unfavourable health behaviours, health and functional impairments, and social risk factors) and 4.3 ± 1.8 deficits in recommended preventive care. At 2 y, favourable health behaviours and use of preventive care were more frequent in the intervention than in the control group (based on z-statistics from generalised estimating equation models). For example, 70% compared to 62% were physically active (odds ratio 1.43, 95% CI 1.16-1.77, p = 0.001), and 66% compared to 59% had influenza vaccinations in the past year (odds ratio 1.35, 95% CI 1.09-1.66, p = 0.005). At 8 y, based on an intention-to-treat analysis, the estimated proportion alive was 77.9% in the intervention and 72.8% in the control group, for an absolute mortality difference of 4.9% (95% CI 1.3%-8.5%, p = 0.009; based on z-test for risk difference). The hazard ratio of death comparing intervention with control was 0.79 (95% CI 0.66-0.94, p = 0.009; based on Wald test from Cox regression model), and the number needed to receive the intervention to prevent one death was 21 (95% CI 12-79). The main limitations of the study include the single-site study design, the use of a brief self-administered questionnaire for 2-y outcome data collection, the unavailability of other long-term outcome data (e.g., functional status, nursing home admissions), and the availability of long-term follow-up data on mortality for analysis only in 2014. CONCLUSIONS This is the first trial to our knowledge demonstrating that a collaborative care model of HRA in community-dwelling older people not only results in better health behaviours and increased use of recommended preventive care interventions, but also improves survival. The intervention tested in our study may serve as a model of how to implement a relatively low-cost but effective programme of disease prevention and health promotion in older individuals. TRIAL REGISTRATION International Standard Randomized Controlled Trial Number: ISRCTN 28458424.
Resumo:
In this chapter a low-cost surgical navigation solution for periacetabular osteotomy (PAO) surgery is described. Two commercial inertial measurement units (IMU, Xsens Technologies, The Netherlands), are attached to a patient’s pelvis and to the acetabular fragment, respectively. Registration of the patient with a pre-operatively acquired computer model is done by recording the orientation of the patient’s anterior pelvic plane (APP) using one IMU. A custom-designed device is used to record the orientation of the APP in the reference coordinate system of the IMU. After registration, the two sensors are mounted to the patient’s pelvis and acetabular fragment, respectively. Once the initial position is recorded, the orientation is measured and displayed on a computer screen. A patient-specific computer model generated from a pre-operatively acquired computed tomography (CT) scan is used to visualize the updated orientation of the acetabular fragment. Experiments with plastic bones (7 hip joints) performed in an operating room comparing a previously developed optical navigation system with our inertial-based navigation system showed no statistical difference on the measurement of acetabular component reorientation (anteversion and inclination). In six out of seven hip joints the mean absolute difference was below five degrees for both anteversion and inclination.
Resumo:
PURPOSE To evaluate a low-cost, inertial sensor-based surgical navigation solution for periacetabular osteotomy (PAO) surgery without the line-of-sight impediment. METHODS Two commercial inertial measurement units (IMU, Xsens Technologies, The Netherlands), are attached to a patient's pelvis and to the acetabular fragment, respectively. Registration of the patient with a pre-operatively acquired computer model is done by recording the orientation of the patient's anterior pelvic plane (APP) using one IMU. A custom-designed device is used to record the orientation of the APP in the reference coordinate system of the IMU. After registration, the two sensors are mounted to the patient's pelvis and acetabular fragment, respectively. Once the initial position is recorded, the orientation is measured and displayed on a computer screen. A patient-specific computer model generated from a pre-operatively acquired computed tomography scan is used to visualize the updated orientation of the acetabular fragment. RESULTS Experiments with plastic bones (eight hip joints) performed in an operating room comparing a previously developed optical navigation system with our inertial-based navigation system showed no statistically significant difference on the measurement of acetabular component reorientation. In all eight hip joints the mean absolute difference was below four degrees. CONCLUSION Using two commercially available inertial measurement units we show that it is possible to accurately measure the orientation (inclination and anteversion) of the acetabular fragment during PAO surgery and therefore to successfully eliminate the line-of-sight impediment that optical navigation systems have.