12 resultados para Long-term pressure overload

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sleep-disordered breathing represents a risk factor for cardiovascular morbidity and mortality and negatively affects short-term and long-term outcome after an ischemic stroke or transient ischemic attack. The effect of continuous positive airways pressure in patients with sleep-disordered breathing and acute cerebrovascular event is poorly known. The SAS CARE 1 study assesses the effects of sleep-disordered breathing on clinical evolution, vascular functions, and markers within the first three-months after an acute cerebrovascular event. The SAS CARE 2 assesses the effect of continuous positive airways pressure on clinical evolution, cardiovascular events, and mortality as well as vascular functions and markers at 12 and 24 months after acute cerebrovascular event.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND/AIMS To investigate the long-term effects of multiple intravitreal injections (IVTs) of ranibizumab (Lucentis) on intraocular pressure (IOP) in patients with neovascular age-related macular degeneration. METHODS In 320 eyes, IOP measurements were performed at baseline prior to injection and compared with IOP measurements of the last visit. Correlations between mean IOP change and total number of IVTs, visual acuity or patient age were tested. RESULTS The mean IOP increase was 0.8 ± 3.1 mm Hg (p < 0.0001). Seven eyes showed final IOP values between 22 and 25 mm Hg. The mean follow-up was 22.7 ± 14.1 months. No further correlations between IOP change and number of IVTs, visual acuity or patient age have been found. CONCLUSIONS This study demonstrated a statistically significant IOP increase in patients treated with repeated injections of ranibizumab. However, IOP increase required no glaucoma treatment during the study. Therefore, repeated injections with ranibizumab can be considered safe with regard to long-term IOP changes in patients without ocular hypertension or glaucoma.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cell transplantation presents great potential for treatment of patients with severe heart failure. However, its clinical application was revealed to be more challenging than initially expected in experimental studies. Further investigations need to be undertaken to define the optimal treatment conditions. We previously reported on the epicardial implantation of a bio-engineered construct of skeletal myoblast-seeded polyurethane and its preventive effect on progression toward heart failure. In the present study, we present a long-term evaluation of this functional outcome. Left anterior descending coronary ligation was performed in female Lewis rats. Two weeks later, animals were treated with either epicardial implantation of biograft, acellular scaffold, sham operation, or direct intramyocardial skeletal myoblast injection. Functional assessments were performed with serial echocardiographies every 3 months and end point left ventricle pressure was assessed. Hearts were then harvested for histological examinations. Myocardial infarction induced a slow and progressive reduction in fractional shortening after 3 months. Progression toward heart failure was significantly prevented for up to 6 months after injection of myoblasts and for up to 9 months following biograft implantation. Nevertheless, this effect vanished after 12 months, with immunohistological examinations revealing an absence of the transplanted myoblasts within the scaffold. We demonstrated that tissue therapy is superior to cell therapy for stabilization of heart function. However, beneficial effects are transient.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Sleep-disordered breathing (SDB) is frequent in stroke patients. Risk factors, treatment response, short-term and long-term outcome of SDB in stroke patients are poorly known. METHODS: We prospectively studied 152 patients (mean age 56+/-13 years) with acute ischemic stroke. Cardiovascular risk factors, Epworth sleepiness score (ESS), stroke severity/etiology, and time of stroke onset were assessed. The apnea-hypopnea index (AHI) was determined 3+/-2 days after stroke onset and 6 months later (subacute phase). Continuous positive airway pressure (CPAP) treatment was started acutely in patients with SDB (AHI > or =15 or AHI > or =10+ESS >10). CPAP compliance, incidence of vascular events, and stroke outcome were assessed 60+/-16 months later (chronic phase). RESULTS: Initial AHI was 18+/-16 (> or =10 in 58%, > or =30 in 17% of patients) and decreased in the subacute phase (P<0.001). Age, diabetes, and nighttime stroke onset were independent predictors of AHI (r2=0.34). In patients with AHI > or =30, age, male gender, body mass index, diabetes, hypertension, coronary heart disease, ESS, and macroangiopathic etiology of stroke were significantly higher/more common than in patients with AHI <10. Long-term incidence of vascular events and stroke outcome were similar in both groups. CPAP was started in 51% and continued chronically in 15% of SDB pts. Long-term stroke mortality was associated with initial AHI, age, hypertension, diabetes, and coronary heart disease. CONCLUSIONS: SDB is common particularly in elderly stroke male patients with diabetes, nighttime stroke onset, and macroangiopathy as cause of stroke; it improves after the acute phase, is associated with an increased poststroke mortality, and can be treated with CPAP in a small percentage of patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Long-term outcome and complications of diode laser cyclophotocoagulation (DCPC) may be important, since eyes, once treated with DCPC, are less likely to be subjected to other types of interventions in the further follow-up. METHODS: Retrospective review of 131 eyes of 127 patients treated from 2000 through 2004. Success was defined as intraocular pressure (IOP) at last visit 6-21 mm Hg; hypotony: IOP

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although experimental prevention studies have suggested therapeutic potential of endothelin (ET) antagonists for the treatment of heart failure, the results of clinical trials using ET antagonists on top of standard heart failure medications have been largely disappointing. This experimental study investigated the effects of chronic ET(A) receptor blockade in long-term survivors of myocardial infarction who had developed stable chronic heart failure in the absence of other treatments. Systolic blood pressure, heart rate, organ weights of the right atrium and ventricle, and the lungs were determined, and tissue ET-1 peptide levels were measured in cardiac tissue, lung, and aorta. The results show that chronic blockade of ET(A) receptors stabilizes systolic blood pressure and reverses the heart failure-induced weight increases of right heart chambers and lung. The changes observed occurred independently of tissue ET-1 concentrations and heart rate, suggesting mechanisms independent of local cardiac or pulmonary ET-1 synthesis, which are yet to be identified.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To describe the urological and nephrological long-term outcome of patients born with classical bladder exstrophy treated with bilateral ureterosigmoidostomies in early childhood. PATIENTS AND METHOD: Out of 42 patients born with bladder exstrophy in Switzerland between 1937 and 1968, 25 participated in this study; seven had died, seven were lost to follow up and three refused consent. Assessment included chart review, clinical examination, and assessment of renal function and morphology. RESULTS: After a follow-up period of 37-69 years ((mean 50 years), 13 of the 25 participants (52%) had their ureterosigmoidostomy still in place. All others had different forms of urinary diversions. Fifteen (60%) patients had normal renal function or mild chronic kidney disease as assessed by estimated glomerular filtration rate. Three patients were on renal replacement therapy. MRI (n=16) showed 10 morphologically normal kidneys. One patient suffered from adenocarcinoma of the colon, five had benign colonic polyps, one urethral papillary carcinoma and 18 no evidence of tumor. CONCLUSION: The majority of our patients have normal or mildly impaired renal function and a well functioning ureterosigmoidostomy. This is remarkable, given the fact that ureterosigmoidostomies are considered to be refluxing high-pressure reservoirs at risk of renal injury and malignancy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To evaluate the long-term outcome of a 12-week outpatient cardiac rehabilitation (CR) program. METHODS: In a prospective single-center interventional cohort study, 201 consecutive patients (133 patients after acute coronary syndrome, 32 patients after heart surgery, and 36 patients with heart failure) attending a 12-week comprehensive outpatient CR program were evaluated for exercise capacity, cardiovascular risk factors (CvRFs), and quality of life at entry, end, and 1.4 years after completion of the program (followup). RESULTS: Physical exercise capacity improved significantly from program entry to program end and remained at this level at followup (P ≤ .006). CvRFs at followup were significantly reduced with regard to smoking prevalence and blood lipids (P < .001). At program end and followup, MacNew heart disease–specific emotional, physical, and social quality of life were improved significantly compared with those at program entry (P < .001). Use of cardioprotective medication remained equally high over the entire study period. However, significantly fewer patients reached blood pressure (<140/90 mm Hg, P = .034) and body mass index (<30 kg/m2, P = .017) goals at followup than at program end. CONCLUSION: The 12-week comprehensive outpatient CR program was successful at reducing important CvRFs long-term.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE In patients with aortic stenosis, left ventricular systolic torsion (pT) is increased to overcome excessive afterload. This study assessed left ventricular torsion before and immediately after surgical valve replacement and tested the instant effect of fluid loading. DESIGN Prospective, clinical single-center study. SETTING Intensive care unit of a university hospital. PARTICIPANTS 12 patients undergoing elective aortic valve replacement for aortic stenosis. INTERVENTIONS Echocardiography was performed on the day before surgery, within 18 hours after surgery including a fluid challenge, and after 2.5 years. MEASUREMENTS AND MAIN RESULTS pT decreased early postoperatively by 21.2% (23.4° ± 5.6° to 18.4° ± 6.9°; p = 0.012) and reached preoperative values at 2.5 years follow-up (24 ± 7). Peak diastolic untwisting velocity occurred later early postoperatively (13% ± 8% to 21% ± 9.4%; p = 0.019) and returned toward preoperative values at follow-up (10.2 ± 4.7°). The fluid challenge increased central venous pressure (8 ± 4 mmHg to 11 ± 4 mmHg; p = 0.003) and reduced peak systolic torsion velocity (138.7 ± 37.6/s to 121.3 ± 32/s; p = 0.032). pT decreased in 3 and increased in 8 patients after fluid loading. Patients whose pT increased had higher early mitral inflow velocity postoperatively (p = 0.04) than those with decreasing pT. Patients with reduced pT after fluid loading received more fluids (p = 0.04) and had a higher positive fluid balance during the intensive care unit stay (p = 0.03). Torsion after fluid loading correlated with total fluid input (p = 0.001) and cumulative fluid balance (p = 0.002). CONCLUSIONS pT decreased early after aortic valve replacement but remained elevated despite elimination of aortic stenosis. After 2.5 years, torsion had returned to preoperative levels.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It is well known that gases adsorb on many surfaces, in particular metal surfaces. There are two main forms responsible for these effects (i) physisorption and (ii) chemisorption. Physisorption is associated with lower binding energies in the order of 1–10 kJ mol−¹, compared to chemisorption which ranges from 100 to 1000 kJ mol−¹. Furthermore, chemisorption only forms monolayers, contrasting physisorption that can form multilayer adsorption. The reverse process is called desorption and follows similar mathematical laws; however, it can be influenced by hysteresis effects. In the present experiment, we investigated the adsorption/desorption phenomena on three steel and three aluminium cylinders containing compressed air in our laboratory and under controlled conditions in a climate chamber, respectively. Our observations from completely decanting one steel and two aluminium cylinders are in agreement with the pressure dependence of physisorption for CO₂, CH₄, and H₂O. The CO₂ results for both cylinder types are in excellent agreement with the pressure dependence of a monolayer adsorption model. However, mole fraction changes due to adsorption on aluminium (< 0.05 and 0 ppm for CO₂ and H₂O) were significantly lower than on steel (< 0.41 ppm and about < 2.5 ppm, respectively). The CO₂ amount adsorbed (5.8 × 1019 CO₂ molecules) corresponds to about the fivefold monolayer adsorption, indicating that the effective surface exposed for adsorption is significantly larger than the geometric surface area. Adsorption/desorption effects were minimal for CH₄ and for CO but require further attention since they were only studied on one aluminium cylinder with a very low mole fraction. In the climate chamber, the cylinders were exposed to temperatures between −10 and +50 °C to determine the corresponding temperature coefficients of adsorption. Again, we found distinctly different values for CO₂, ranging from 0.0014 to 0.0184 ppm °C−¹ for steel cylinders and −0.0002 to −0.0003 ppm °C−¹ for aluminium cylinders. The reversed temperature dependence for aluminium cylinders points to significantly lower desorption energies than for steel cylinders and due to the small values, they might at least partly be influenced by temperature, permeation from/to sealing materials, and gas-consumption-induced pressure changes. Temperature coefficients for CH₄, CO, and H₂O adsorption were, within their error bands, insignificant. These results do indicate the need for careful selection and usage of gas cylinders for high-precision calibration purposes such as requested in trace gas applications.