102 resultados para Leg Length
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Background Leg length inequality (LLI) was identified as a problem of total hip arthroplasty soon after its introduction. Leg lengthening is the most common form of LLI. Possible consequences are limping, neuronal dysfunction and aseptic component loosening. LLI can result in an increased strain both on the contralateral hip joint and on the abductor muscles. We assessed the influence of leg lengthening and shortening on walking capacity, hip pain, limping and patient satisfaction at 2-year follow-up. Methods 478 cases with postoperative lengthening and 275 with shortening were identified, and matched with three controls each. Rigorous adjustment for potential differences in baseline patient characteristics was performed by propensity-score matching of covariates. The arbitrarily defined desired outcomes were a walking capacity >60 minutes, no hip pain, no limping, and excellent patient satisfaction. Differences in not achieving the desired outcomes between the groups were expressed as odds ratios. Results In the lengthened case group, the odds ratio for not being able to walk for an hour was 1.70 (95% CI 1.28-2.26) for cases compared to controls, and the odds ratio for having hip pain at follow-up was 1.13 (95% CI 0.78-1.64). The odds ratio for limping was 2.08 (95% CI 1.55-2.80). The odds ratio for not achieving excellent patient satisfaction was 1.67 (95% CI 1.23-2.28). In the shortening case group, the odds ratio for not being able to walk for an hour was 1.23 (95% CI 0.84-1.81), and the odds ratio for having hip pain at follow-up was 1.60 (95% CI 1.05-2.44). The odds ratio for limping for cases was 2.61 (95% CI 1.78-3.21). The odds ratio for not achieving excellent patient satisfaction was 2.15 (95% CI 1.44-3.21). Conclusions Walking capacity, limping and patient satisfaction were all significantly associated with leg lengthening, whereas pain alleviation was not. In contrast, hip pain, limping and patient satisfaction were all significantly associated with leg shortening, whereas walking capacity was not.
Resumo:
This paper presents a novel technique to create a computerized fluoroscopy with zero-dose image updates for computer-assisted fluoroscopy-based close reduction and osteosynthesis of diaphyseal fracture of femurs. With the novel technique, repositioning of bone fragments during close fracture reduction will lead to image updates in each acquired imaging plane, which is equivalent to using several fluoroscopes simultaneously from different directions but without any X-ray radiation. Its application facilitates the whole fracture reduction and osteosynthesis procedure when combining with the existing leg length and antetorsion restoration methods and may result in great reduction of the X-ray radiation to the patient and to the surgical team. In this paper, we present the approach for achieving such a technique and the experimental results with plastic bones.
Resumo:
Component malpositioning and postoperative leg length discrepancy are the most common technical problems associated with total hip arthroplasty (THA). Surgical navigation offers the potential to reduce the incidence of these problems. We reviewed 317 patients (344 hips) that underwent THA using computed tomography-based surgical navigation, including 112 THAs using a simplified method of measuring leg length. Guided by the navigation system, cups were placed in 40.8 degrees +/- 2 degrees of operative abduction (range, 35 degrees -50 degrees) and 30.8 degrees +/- 3.2 degrees (range, 19 degrees -43 degrees) of operative anteversion. We subsequently measured radiographic abduction on plain anteroposterior pelvic radiographs and calculated abduction and anteversion. Radiographically, 97.1 % of the cups were in the safe zone for abduction and 92.4% for anteversion. The mean incision length was less than 8 cm for 327 of the 344 hips. Leg length change measured intraoperatively was 6.6 +/- 4.1 mm (range, -2-22), similar to measurements from the pre- and postoperative magnification-corrected radiographs. Computer assistance during THA increased the consistency of component positioning and allowed reliable measurement of leg length change during surgery.
Resumo:
OBJECTIVE The aim of the therapy is mechanical and functional stabilization of high dislocated hips with dysplasia coxarthrosis using total hip arthroplasty (THA). INDICATIONS Developmental dysplasia of the hip (DDH) in adults, symptomatic dysplasia coxarthrosis, high hip dislocation according to Crowe type III/IV, and symptomatic leg length inequality. CONTRAINDICATIONS Cerebrospinal dysfunction, muscular dystrophy, apparent disturbance of bone metabolism, acute or chronic infections, and immunocompromised patients. SURGICAL TECHNIQUE With the patient in a lateral decubitus position an incision is made between the anterior border of the gluteus maximus muscle and the posterior border of the gluteus medius muscle (Gibson interval). Identification of the sciatic nerve to protect the nerve from traction disorders by visual control. After performing trochanter flip osteotomy, preparation of the true actetabulum if possible. Implantation of the reinforcement ring, preparation of the femur and if necessary for mobilization, resection until the trochanter minor. Test repositioning under control of the sciatic nerve. Finally, refixation of the trochanteric crest. POSTOPERATIVE MANAGEMENT During hospital stay, intensive mobilization of the hip joint using a continuous passive motion machine with maximum flexion of 70°. No active abduction and passive adduction over the body midline. Maximum weight bearing 10-15 kg for 8 weeks, subsequently, first clinical and radiographic follow-up and deep venous thrombosis prophylaxis until full weight bearing. RESULTS From 1995 to 2012, 28 THAs of a Crow type IV high hip-dislocation were performed in our institute. Until now 14 patients have been analyzed during a follow-up of 8 years in 2012. Mid-term results showed an improvement of the postoperative clinical score (Merle d'Aubigné score) in 86 % of patients. Good to excellent results were obtained in 79 % of cases. Long-term results are not yet available. In one case an iatrogenic neuropraxia of the sciatic nerve was observed and after trauma a redislocation of the arthroplasty appeared in another case. In 2 cases an infection of the THA appeared 8 and 15 months after index surgery. No pseudoarthrosis of the trochanter or aseptic loosening was noticed.
Resumo:
PURPOSE Despite the fact that new and modern short-stems allow bone sparing and saving of soft-tissue and muscles, we still face the challenge of anatomically reconstructing the femoro-acetabular offset and leg length. Therefore a radiological and clinical analysis of a short-stem reconstruction of the femoro-acetabular offset and leg length was performed. METHODS Using an antero-lateral approach, the optimys short-stem (Mathys Ltd, Bettlach, Switzerland) was implanted in 114 consecutive patients in combination with a cementless cup (Fitmore, Zimmer, Indiana, USA; vitamys RM Pressfit, Mathys Ltd, Bettlach, Switzerland). Pre- and postoperative X-rays were done in a standardized technique. In order to better analyse and compare X-ray data a special double coordinate system was developed for measuring femoral- and acetabular offset. Harris hip score was assessed before and six weeks after surgery. Visual analogue scale (VAS) satisfaction, leg length difference and the existence of gluteal muscle insufficiency were also examined. RESULTS Postoperative femoral offset was significantly increased by a mean of 5.8 mm. At the same time cup implantation significantly decreased the acetabular offset by a mean of 3.7 mm, which resulted in an increased combined femoro-acetabular offset of 2.1 mm. Postoperatively, 81.7 % of patients presented with equal leg length. The maximum discrepancy was 10 mm. Clinically, there were no signs of gluteal insufficiency. No luxation occurred during hospitalization. The Harris hip score improved from 47.3 before to 90.1 points already at six weeks after surgery while the mean VAS satisfaction was 9.1. CONCLUSION The analysis showed that loss of femoro-acetabular offset can be reduced with an appropriate stem design. Consequently, a good reconstruction of anatomy and leg length can be achieved. In the early postoperative stage the clinical results are excellent.
Resumo:
This chapter proposed a personalized X-ray reconstruction-based planning and post-operative treatment evaluation framework called iJoint for advancing modern Total Hip Arthroplasty (THA). Based on a mobile X-ray image calibration phantom and a unique 2D-3D reconstruction technique, iJoint can generate patient-specific models of hip joint by non-rigidly matching statistical shape models to the X-ray radiographs. Such a reconstruction enables a true 3D planning and treatment evaluation of hip arthroplasty from just 2D X-ray radiographs whose acquisition is part of the standard diagnostic and treatment loop. As part of the system, a 3D model-based planning environment provides surgeons with hip arthroplasty related parameters such as implant type, size, position, offset and leg length equalization. With this newly developed system, we are able to provide true 3D solutions for computer assisted planning of THA using only 2D X-ray radiographs, which is not only innovative but also cost-effective.
Resumo:
Purpose: To quantify the in vivo deformations of the popliteal artery during leg flexion in subjects with clinically relevant peripheral artery disease (PAD). Methods: Five patients (4 men; mean age 69 years, range 56–79) with varying calcification levels of the popliteal artery undergoing endovascular revascularization underwent 3-dimensional (3D) rotational angiography. Image acquisition was performed with the leg straight and with a flexion of 70°/20° in the knee/hip joints. The arterial centerline and the corresponding branches in both positions were segmented to create 3D reconstructions of the arterial trees. Axial deformation, twisting, and curvatures were quantified. Furthermore, the relationships between the calcification levels and the deformations were investigated. Results: An average shortening of 5.9%±2.5% and twist rate of 3.8±2.2°/cm in the popliteal artery were observed. Maximal curvatures in the straight and flexed positions were 0.12±0.04 cm−1 and 0.24±0.09 cm−1, respectively. As the severity of calcification increased, the maximal curvature in the straight position increased from 0.08 to 0.17 cm−1, while an increase from 0.17 to 0.39 cm−1 was observed for the flexed position. Axial elongations and arterial twisting were not affected by the calcification levels. Conclusion: The popliteal artery of patients with symptomatic PAD is exposed to significant deformations during flexion of the knee joint. The severity of calcification directly affects curvature, but not arterial length or twisting angles. This pilot study also showed the ability of rotational angiography to quantify the 3D deformations of the popliteal artery in patients with various levels of calcification.
Resumo:
Congenital pseudarthrosis of the tibia (CPT) is caused by an ill-defined, segmental disturbance of periosteal bone formation leading to spontaneous bowing, followed by fracture and subsequent pseudarthrosis in the first 2 years of life. The results of conventional treatment modalities (e.g., bracing, internal and external fixation and bone grafting) are associated with high failure rates in terms of persisting pseudarthrosis, malunion and impaired growth. As a more promising alternative, a more aggressive approach, including wide resection of the affected bone, reconstruction with free vascularised fibula grafts from the healthy contralateral leg and stable external fixation at a very early stage has been suggested. Between 1995 and 2007, 10 children (age 12-31 months, median 20 months) suffering from CPT were treated at our institutions according to this principle. Two patients were treated before a fracture had occurred. The length of the fibula graft was 7-9cm. End-to-end anastomoses were performed at the level of the distal tibia stump. The follow-up was 80 months (median, range 12 months to 12 years). Radiologic examination at 6 weeks postoperatively showed normal bone density and structure of the transplanted fibula in all cases and osseous consolidation at 19 of the 20 graft/tibia junctions. One nonunion was sucessfully treated with bone grafting and plate osteosynthesis. Pin-tract infection occurred in three patients. Five children sustained graft fractures that were successfully treated with internal or external fixation. Two patients developed diminished growth of the affected limb or foot; all others had equal limb length and shoe size. At long-term follow-up, tibialisation of the transplant had occurred, and normal gait and physical activities were possible in all children. We conclude that in spite of a relatively high complication rate and the reluctance to perform free flap surgery in infants at this young age, the present concept may successfully prevent the imminent severe sequelae associated with CPT.
Resumo:
A spatial, electro-optical autocorrelation (EOA) interferometer using the vertically polarized lobes of coherent transition radiation (CTR) has been developed as a single-shot electron bunch length monitor at an optical beam port downstream the 100 MeV preinjector LINAC of the Swiss Light Source. This EOA monitor combines the advantages of step-scan interferometers (high temporal resolution) [D. Mihalcea et al., Phys. Rev. ST Accel. Beams 9, 082801 (2006) and T. Takahashi and K. Takami, Infrared Phys. Technol. 51, 363 (2008)] and terahertz-gating technologies [U. Schmidhammer et al., Appl. Phys. B: Lasers Opt. 94, 95 (2009) and B. Steffen et al., Phys. Rev. ST Accel. Beams 12, 032802 (2009)] (fast response), providing the possibility to tune the accelerator with an online bunch length diagnostics. While a proof of principle of the spatial interferometer was achieved by step-scan measurements with far-infrared detectors, the single-shot capability of the monitor has been demonstrated by electro-optical correlation of the spatial CTR interference pattern with fairly long (500 ps) neodymium-doped yttrium aluminum garnet (Nd:YAG) laser pulses in a ZnTe crystal. In single-shot operation, variations of the bunch length between 1.5 and 4 ps due to different phase settings of the LINAC bunching cavities have been measured with subpicosecond time resolution.
Resumo:
By measuring the total crack lengths (TCL) along a gunshot wound channel simulated in ordnance gelatine, one can calculate the energy transferred by a projectile to the surrounding tissue along its course. Visual quantitative TCL analysis of cut slices in ordnance gelatine blocks is unreliable due to the poor visibility of cracks and the likely introduction of secondary cracks resulting from slicing. Furthermore, gelatine TCL patterns are difficult to preserve because of the deterioration of the internal structures of gelatine with age and the tendency of gelatine to decompose. By contrast, using computed tomography (CT) software for TCL analysis in gelatine, cracks on 1-cm thick slices can be easily detected, measured and preserved. In this, experiment CT TCL analyses were applied to gunshots fired into gelatine blocks by three different ammunition types (9-mm Luger full metal jacket, .44 Remington Magnum semi-jacketed hollow point and 7.62 × 51 RWS Cone-Point). The resulting TCL curves reflected the three projectiles' capacity to transfer energy to the surrounding tissue very accurately and showed clearly the typical energy transfer differences. We believe that CT is a useful tool in evaluating gunshot wound profiles using the TCL method and is indeed superior to conventional methods applying physical slicing of the gelatine.
Resumo:
Periodic leg movements (PLM) during sleep consist of involuntary periodic movements of the lower extremities. The debated functional relevance of PLM during sleep is based on correlation of clinical parameters with the PLM index (PLMI). However, periodicity in movements may not be reflected best by the PLMI. Here, an approach novel to the field of sleep research is used to reveal intrinsic periodicity in inter movement intervals (IMI) in patients with PLM.
Resumo:
Background Leg edema is a common manifestation of various underlying pathologies. Reliable measurement tools are required to quantify edema and monitor therapeutic interventions. Aim of the present work was to investigate the reproducibility of optoelectronic leg volumetry over 3 weeks' time period and to eliminate daytime related within-individual variability. Methods Optoelectronic leg volumetry was performed in 63 hairdressers (mean age 45 ± 16 years, 85.7% female) in standing position twice within a minute for each leg and repeated after 3 weeks. Both lower leg (legBD) and whole limb (limbBF) volumetry were analysed. Reproducibility was expressed as analytical and within-individual coefficients of variance (CVA, CVW), and as intra-class correlation coefficients (ICC). Results A total of 492 leg volume measurements were analysed. Both legBD and limbBF volumetry were highly reproducible with CVA of 0.5% and 0.7%, respectively. Within-individual reproducibility of legBD and limbBF volumetry over a three weeks' period was high (CVW 1.3% for both; ICC 0.99 for both). At both visits, the second measurement revealed a significantly higher volume compared to the first measurement with a mean increase of 7.3 ml ± 14.1 (0.33% ± 0.58%) for legBD and 30.1 ml ± 48.5 ml (0.52% ± 0.79%) for limbBF volume. A significant linear correlation between absolute and relative leg volume differences and the difference of exact day time of measurement between the two study visits was found (P < .001). A therefore determined time-correction formula permitted further improvement of CVW. Conclusions Leg volume changes can be reliably assessed by optoelectronic leg volumetry at a single time point and over a 3 weeks' time period. However, volumetry results are biased by orthostatic and daytime-related volume changes. The bias for day-time related volume changes can be minimized by a time-correction formula.
Resumo:
The objective of this pilot investigation was to evaluate the utility and precision of already existing limited cone-beam computed tomography (CBCT) scans in measuring the endodontic working length, and to compare it with standard clinical procedures.