75 resultados para Late early Oligocene
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
This study uses the widths, the spacing and the grain-size pattern of Oligo/Miocene alluvial fan conglomerates in the central segment of the Swiss Alpine foreland to reconstruct the topographic development of the Alps. These data are analysed with models of longitudinal stream profile development, to propose that the Alpine topography evolved from an early transient state where streams adjusted to rock uplift by headward retreat, to a mature phase where any changes in rock uplift were accommodated by vertical incision. The first stage comprises the time interval between ca 31 Ma and 22 Ma, when the Alpine streams deposited many small fans with a lateral spacing of <30 km in the north Alpine foreland. As the range evolved, the streams joined and the fans coalesced into a few large depositional systems with a lateral spacing of ca 80 to 100 km at 22 Ma. The models used here suggest that the overall elevation of the Alps increased rapidly within <5 Myr. The variability in pebble size increased either due to variations in sediment supply, enhanced orographic effects, or preferentially due to a change towards a stormier palaeoclimate. By 22 Ma, only two large rivers carried material into the foreland fans, suggesting that the major Alpine streams had established themselves. This second phase of stable drainage network was maintained until ca 5 Ma, when the uplift and erosion of the Molasse started and streams were redirected both in the Alps and in the foreland. This study illustrates that sedimentological archives of foreland basins can be used to reconstruct the chronology of the topographic development of mountain belts. It is suggested that the finite elevation of mountainous landscapes is reached early during orogeny and can be maintained for millions of years, provided that erosion is efficient.
Resumo:
The advent of highly active antiretroviral therapy (HAART) in 1996 led to a decrease in the incidence of Kaposi's sarcoma (KS) and non-Hodgkin's lymphoma (NHL), but not of other cancers, among people with HIV or AIDS (PWHA). It also led to marked increases in their life expectancy.
Resumo:
Early-generation drug-eluting stents releasing sirolimus (SES) or paclitaxel (PES) are associated with increased risk of very late stent thrombosis occurring >1 year after stent implantation. It is unknown whether the risk of very late stent thrombosis persists with newer-generation everolimus-eluting stents (EES).
Resumo:
PURPOSE: Limited information is available concerning changes in the urodynamic characteristics of orthotopic bladder substitutes with time. Therefore, we compared early and late urodynamic results in patients with an ileal orthotopic bladder substitute combined with an afferent tubular segment. MATERIALS AND METHODS: Of 139 patients surviving at least 5 years after cystoprostatectomy and ileal orthotopic bladder substitution with an afferent tubular segment 119 underwent urodynamic assessment, including 66 at a median of 9 months (early) and 77 at a median of 62 months (late). Of these patients 24 were assessed at each time point. Simultaneously all patients were asked to complete a bladder diary and questionnaire regarding continence for at least 3 days in the week preceding the urodynamic study. RESULTS: Urodynamic parameters were comparable in patients who were evaluated early and late postoperatively. In addition, median values at early and late urodynamic evaluation in the 24 patients with the 2 examinations showed no statistically significant differences for volume at first desire to void (300 vs 333 ml, p = 0.85), pressure at first desire to void (12 vs 13 cm H2O, p = 0.57), maximum cystometric capacity (450 vs 453 ml, p = 0.84), end filling pressure (19 vs 20 cm H2O, p = 0.17), reservoir compliance (25 vs 28 ml/cm H2O, p = 0.58) or post-void residual urine volume (5 vs 15 ml, p = 0.27). CONCLUSIONS: Urodynamic results after 5 years of living with an ileal orthotopic bladder substitute with an afferent tubular segment show grossly unchanged urodynamic characteristics. Patients maintain a reservoir capacity and micturition pattern consistent with a normal life-style. Reservoir pressure remained low, thereby protecting and preserving upper tract function. To achieve these results patients must be regularly followed, and the causes of bacteriuria, increased post-void residual urine and bladder outlet obstruction must be recognized and dealt with accordingly.
Resumo:
BACKGROUND: Stent thrombosis is a safety concern associated with use of drug-eluting stents. Little is known about occurrence of stent thrombosis more than 1 year after implantation of such stents. METHODS: Between April, 2002, and Dec, 2005, 8146 patients underwent percutaneous coronary intervention with sirolimus-eluting stents (SES; n=3823) or paclitaxel-eluting stents (PES; n=4323) at two academic hospitals. We assessed data from this group to ascertain the incidence, time course, and correlates of stent thrombosis, and the differences between early (0-30 days) and late (>30 days) stent thrombosis and between SES and PES. FINDINGS: Angiographically documented stent thrombosis occurred in 152 patients (incidence density 1.3 per 100 person-years; cumulative incidence at 3 years 2.9%). Early stent thrombosis was noted in 91 (60%) patients, and late stent thrombosis in 61 (40%) patients. Late stent thrombosis occurred steadily at a constant rate of 0.6% per year up to 3 years after stent implantation. Incidence of early stent thrombosis was similar for SES (1.1%) and PES (1.3%), but late stent thrombosis was more frequent with PES (1.8%) than with SES (1.4%; p=0.031). At the time of stent thrombosis, dual antiplatelet therapy was being taken by 87% (early) and 23% (late) of patients (p<0.0001). Independent predictors of overall stent thrombosis were acute coronary syndrome at presentation (hazard ratio 2.28, 95% CI 1.29-4.03) and diabetes (2.03, 1.07-3.83). INTERPRETATION: Late stent thrombosis was encountered steadily with no evidence of diminution up to 3 years of follow-up. Early and late stent thrombosis were observed with SES and with PES. Acute coronary syndrome at presentation and diabetes were independent predictors of stent thrombosis.