29 resultados para Laser cooling and trapping

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND/AIM: To compare the ability of confocal scanning laser tomography (CSLT), scanning laser polarimetry (SLP) and optical coherence tomography (OCT) in recognising localised retinal nerve fibre layer (RNFL) defects. METHODS: 51 eyes from 43 patients with glaucoma were identified by two observers as having RNFL defects visible on optic disc photographs. 51 eyes of 32 normal subjects were used as controls. Three masked observers evaluated CSLT, SLP and OCT images to determine subjectively the presence of localised RNFL defects. RESULTS: Interobserver agreement was highest with OCT, followed by SLP and CSLT (mean kappa: 0.83, 0.69 and 0.64, respectively). RNFL defects were identified in 58.8% of CSLT, 66.7% of SLP and 54.9% of OCT (p = 0.02 between SLP and OCT) by at least two observers. In the controls, 94.1% of CSLT, 84.3% of SLP and 94.1% of OCT scans, respectively, were rated as normal (p = 0.02 between CSLT and SLP, and SLP and OCT). CONCLUSION: Approximately 20-40% of localised RNFL defects identified by colour optic disc photographs are not detected by CSLT, SPL or OCT. SLP showed a higher number of false-positive results than the other techniques, but also had a higher proportion of correctly identified RNFL defects in the glaucoma population.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In modern implant dentistry there are several clinical indications for laser surgery. Different laser systems have a considerable spectrum of application in soft and hard peri-implant tissues. The literature was searched for clinical application of different laser wavelengths in peri-implant tissues: second-stage surgery of submerged implants, treatment of infrabony defects, removal of peri-implant hyperplastic overgrowths, and, possibly, the preparation of bone cavities for implant placement. This report describes the state-of-the-art application of different laser systems in modern implant dentistry for the treatment of peri-implant lesions and decontamination of implant surfaces. Our study evaluated in vitro examinations, clinical experience and long-term clinical studies. The exact selection of the appropriate laser system and wavelength was dependent on the scientific evaluation of recent literature and the level of changes in implant and tissue temperatures during laser application. The significant reduction in bacteria on the implant surface and the peri-implant tissues during irradiation and the cutting effects associated with the coagulation properties of the lasers are the main reasons for laser application in the treatment of peri-implant lesions and the successful long-term prognosis of failing oral implants. The various applications of lasers in implant dentistry are dependent on the wavelength and laser-tissue interactions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Spectral domain optical coherence tomography (SD-OCT) in patients can deliver retinal cross-sectional images with high resolution. This may allow the evaluation of the extent of damage to the retinal pigment epithelium (RPE) and the neurosensory retina after laser treatment. This article aims to investigate the value of SD-OCT in comparing laser lesions produced by conventional laser photocoagulation and selective retina treatment (SRT).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Laser pulses are largely used for processing and analysis of materials and in particular for nano-particle synthesis. This paper addresses fundamentals of the generation of nano-materials following specific thermodynamic paths of the irradiated material. Computer simulations using the hydro code MULTI and the SESAME equation of state have been performed to follow the dynamics of a target initially heated by a short laser pulse over a distance comparable to the metal skin depth.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Laser tissue soldering (LTS) is a promising technique for tissue fusion based on a heat-denaturation process of proteins. Thermal damage of the fused tissue during the laser procedure has always been an important and challenging problem. Particularly in LTS of arterial blood vessels strong heating of the endothelium should be avoided to minimize the risk of thrombosis. A precise knowledge of the temperature distribution within the vessel wall during laser irradiation is inevitable. The authors developed a finite element model (FEM) to simulate the temperature distribution within blood vessels during LTS. Temperature measurements were used to verify and calibrate the model. Different parameters such as laser power, solder absorption coefficient, thickness of the solder layer, cooling of the vessel and continuous vs. pulsed energy deposition were tested to elucidate their impact on the temperature distribution within the soldering joint in order to reduce the amount of further animal experiments. A pulsed irradiation with high laser power and high absorbing solder yields the best results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Plants exhibit life-long organogenic and histogenic activity in a specialised organ, the shoot apical meristem. Leaves and flowers are formed within the ring-shaped peripheral zone, which surrounds the central zone, the site of the stem cells. We have undertaken a series of high-precision laser ablation and microsurgical tissue removal experiments to test the functions of different parts of the tomato meristem, and to reveal their interactions. Ablation of the central zone led to ectopic expression of the WUSCHEL gene at the periphery, followed by the establishment of a new meristem centre. After the ablation of the central zone, organ formation continued without a lag. Thus, the central zone does not participate in organogenesis, except as the ultimate source of founder cells. Microsurgical removal of the external L-1 layer induced periclinal cell divisions and terminal differentiation in the subtending layers. In addition, no organs were initiated in areas devoid of L-1, demonstrating an important role of the L-1 in organogenesis. L-1 ablation had only local effects, an observation that is difficult to reconcile with phyllotaxis theories that invoke physical tension operating within the meristem as a whole. Finally, regeneration of L-1 cells was never observed after ablation. This shows that while the zones of the meristem show a remarkable capacity to regenerate after interference, elimination of the L-1 layer is irreparable and causes terminal differentiation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The BepiColombo Laser Altimeter (BELA) has been selected to fly on ESA׳s BepiColombo mission to Mercury. The instrument will be the first European laser altimeter designed for interplanetary flight. This paper describes the setup used to characterize the angular movements of BELA under the simulated environmental conditions that the instrument will encounter when orbiting Mercury. The system comprises a laser transmitter and a receiving telescope, which can move with respect to each other under thermal load. Tests performed using the Engineering Qualification Model show that the setup is accurate enough to characterize angular movements of the instrument components to an accuracy of ≈10 μrad. The qualification instrument is thermally stable to operate during all mission phases around Mercury proving that the transmitter and receiver sections will remain within the alignment requirements during its mission.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In humans, there are different types of cutaneous cold-sensitive afferents responsible for cold sensation and cold pain. Innocuous cold is primarily mediated by a population of slow A delta afferents, based on psychophysical and neurophysiological studies. Noxious cold (usually below 15 degrees C) is mediated, at least in part, by polymodal nociceptors. There is also a population of unmyelinated afferents responsive to innocuous low temperature, some of which also respond to heat, whose sensory function has not been completely defined. A paradoxical hot/burning evoked by cooling is unmasked by A-fibre block, and similar sensations are evoked by applying simultaneous cool and warm stimuli to adjacent skin areas. These unmyelinated fibres activated by innocuous cooling (and heating) may contribute to this hot/burning sensation, along with other thermoregulatory functions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Impacts of low-latitude, explosive volcanic eruptions on climate and the carbon cycle are quantified by forcing a comprehensive, fully coupled carbon cycle-climate model with pulse-like stratospheric aerosol optical depth changes. The model represents the radiative and dynamical response of the climate system to volcanic eruptions and simulates a decrease of global and regional atmospheric surface temperature, regionally distinct changes in precipitation, a positive phase of the North Atlantic Oscillation, and a decrease in atmospheric CO2 after volcanic eruptions. The volcanic-induced cooling reduces overturning rates in tropical soils, which dominates over reduced litter input due to soil moisture decrease, resulting in higher land carbon inventories for several decades. The perturbation in the ocean carbon inventory changes sign from an initial weak carbon sink to a carbon source. Positive carbon and negative temperature anomalies in subsurface waters last up to several decades. The multi-decadal decrease in atmospheric CO2 yields a small additional radiative forcing that amplifies the cooling and perturbs the Earth System on longer time scales than the atmospheric residence time of volcanic aerosols. In addition, century-scale global warming simulations with and without volcanic eruptions over the historical period show that the ocean integrates volcanic radiative cooling and responds for different physical and biogeochemical parameters such as steric sea level or dissolved oxygen. Results from a suite of sensitivity simulations with different magnitudes of stratospheric aerosol optical depth changes and from global warming simulations show that the carbon cycle-climate sensitivity γ, expressed as change in atmospheric CO2 per unit change in global mean surface temperature, depends on the magnitude and temporal evolution of the perturbation, and time scale of interest. On decadal time scales, modeled γ is several times larger for a Pinatubo-like eruption than for the industrial period and for a high emission, 21st century scenario.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated the enamel loss and composite remnants after debonding and clean-up. The tested null hypothesis is that there are no differences between different polishing systems regarding removing composite remnants without damaging the tooth surface. Brackets were bonded to 75 extracted human molars and removed after a storage period of 100 hours. The adhesive remnant index (ARI) was evaluated. The clean-up was carried out with five different procedures: 1. carbide bur; 2. carbide bur and Brownie and Greenie silicone polishers; 3. carbide bur and Astropol polishers; 4. carbide bur and Renew polishers; and 5. carbide bur, Brownie, Greenie and PoGo polishers. Silicone impressions were made at baseline (T0) and after debonding (T1) and polishing (T2) to produce plaster replicas. The replicas were analysed with a three-dimensional laser scanner and measured with analytical software. Statistical analysis was performed with the Kruskal-Wallis test and pairwise Wilcoxon tests with Bonferroni-Holm adjustment (α = 0.05). Enamel breakouts after debonding were detectable in 27 per cent of all cases, with a mean volume loss of 0.02 mm(3) (±0.03 mm(3)) and depth of 44.9 μm (±48.3 μm). The overall ARI scores was 3 with a few scores of 1 and 2. The composite remnants after debonding had a mean volume of 2.48 mm(3) (±0.92 mm(3)). Mean volume loss due to polishing was 0.05 mm(3) (±0.26 mm(3)) and the composite remnants had a mean volume of 0.22 mm(3) (±0.32 mm(3)). There were no statistically significant differences in volumetric changes after polishing (P = 0.054) between the different clean-up methods. However, sufficient clean-up without enamel loss was difficult to achieve.