3 resultados para LITHIUM 7

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The stereoselective syntheses of 7,8,9-trideoxypeloruside A (4) and a monocyclic peloruside A analogue lacking the entire tetrahydropyran moiety (3) are described. The syntheses proceeded through the PMB-ether of an ω-hydroxy β-keto aldehyde as a common intermediate which was elaborated into a pair of diastereomeric 1,3-syn and -anti diols by stereoselective Duthaler–Hafner allylations and subsequent 1,3-syn or anti reduction. One of these isomers was further converted into a tetrahydropyran derivative in a high-yielding Prins reaction, to provide the precursor for bicyclic analogue 4. Downstream steps for both syntheses included the substrate-controlled addition of a vinyl lithium intermediate to an aldehyde, thus connecting the peloruside side chain to C15 (C13) of the macrocyclic core structure in a fully stereoselective fashion. In the case of monocyclic 3 macrocyclization was based on ring-closing olefin metathesis (RCM), while bicyclic 4 was cyclized through Yamaguchi-type macrolactonization. The macrolactonization step was surprisingly difficult and was accompanied by extensive cyclic dimer formation. Peloruside A analogues 3 and 4 inhibited the proliferation of human cancer cell lines in vitro with micromolar and sub-micromolar IC50 values, respectively. The higher potency of 4 highlights the importance of the bicyclic core structure of peloruside A for nM biological activity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Cardiac output (CO) measurement with lithium dilution (COLD) has not been fully validated in sheep using precise ultrasonic flow probe technology (COUFP). Sheep generate important cardiovascular research models and the use of COLD has become more popular in experimental settings. METHODS: Ultrasonic transit-time perivascular flow probes were surgically implanted on the pulmonary artery of 13 sheep. Paired COLD readings were taken at six time points, before and after implantation of a left ventricular assist device (LVAD) and compared with COUFP recorded just after lithium injection. RESULTS: The mean COLD was 5.7 litre min(-1) (range 3.8-9.6 litre min(-1)) and mean COUFP 5.9 litre min(-1) (range 4.0-9.2 litre min(-1)). The bias (standard deviation) was 0.3 (1.0) litre min(-1) [5.1 (16.9)%] and limits of agreement (LOA) were -1.7 to 2.3 litre min(-1) (-28.8 to 39.0%) with a percentage error (PE) of 34.4%. Data to assess trending [rate (95% confidence intervals)] included a 78 (62-93)% concordance rate in the four-quadrant plot (n=27). In the half moon polar plot (n=19), the mean polar angle was +5°, the radial LOA were -49 to +35° and 68 (47-89)% of data points fell within 22.5° of the mean polar angle. Both tests indicated moderate to poor trending ability. CONCLUSION: COLD is not precise when evaluated against COUFP in sheep based on the statistical criteria set, but the results are comparable with previously published animal studies. KEYWORDS: