34 resultados para LATERAL WINDOW APPROACH
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
PURPOSE To analyze the frequency of perforation of the sinus membrane during maxillary sinus floor elevation (SFE) and to assess possible risk factors. MATERIALS AND METHODS Seventy-seven cases of SFE performed with a lateral window approach were evaluated retrospectively. Clinical and radiographic variables potentially influencing the risk of sinus membrane perforation were evaluated and divided into patient-related factors (age, sex, smoking habit); surgery-related factors (type of surgical approach, side, units, sites, and technique of osteotomy); and maxillary sinus-related factors (presence and height of septum, height of residual ridge, thickness of lateral sinus wall, width of antrum, and thickness and status of sinus membrane). RESULTS The following factors presented with at least a 10% difference in rates of perforations: smokers (46.2%) versus nonsmokers (23.4%), simultaneous (32%) versus staged (18.5%) approach, mixed premolar-molar sites (41.2%) versus premolar-only sites (16.7%) versus molar-only sites (26.2%), presence of septa (42.9%) versus no septa (23.8%), and minimum height of residual ridge ≤4 mm (34.2%) versus > 4 mm (20.5%). These same parameters, except minimum height of residual ridge, also showed an odds ratio above 2. However, none of the comparisons reached statistical significance. CONCLUSION The present study failed to demonstrate any factor that statistically significantly increased the risk of sinus membrane perforation during SFE using the lateral window approach.
Resumo:
Purpose: Radiographic evaluation of the vertical presurgical ridge height (PRH) of implants, placed using the transcrestal or lateral window sinus floor elevation (SFE) technique in edentulous and partially dentate patients. The 5-year implant survival rate and the prosthetic restoration following the SFE procedure were also evaluated. Methods: Radiographs of 83 tapered implants placed in 53 patients were available for analysis. 31 implants were placed by the transcrestal and 52 were placed by the lateral window technique. In the lateral window technique 21 implants were placed simultaneously, 31 in a staged approach. The PRH, the implant survival rate after five years and the prosthetic restoration were evaluated with respect to the chosen SFE procedure. Results: The PRH was significantly higher for the transcrestal than both lateral window techniques, mean values: 8.0 ± 2.7 mm (transcrestal); 4.2 ± 2.6 mm (lateral simultaneous); 4.5 ± 2.8 mm (lateral staged). There was no significant difference of PRH between the edentulous and partially dentate patients. All loaded implants were stable, resulting in a 100% implant survival rate after 5 years. There was a small overproportion of single crown restorations in the transcrestal SFE technique group. Conclusion: This study confirms that the transcrestal technique is chosen, when a higher PRH is available. The choice of a simultaneous or staged lateral window approach is mainly dependent on the expected primary stability of the implant and not only on the PRH. SFE procedures are a safe and predictable treatment option to place implants in the vertical atrophic maxilla.
Lamb Temporal Bone as a Surgical Training Model of Round Window Cochlear Implant Electrode Insertion
Resumo:
OBJECTIVE The preservation of residual hearing in cochlear implantation opens the door for optimal functional results. This atraumatic surgical technique requires training; however, the traditional human cadaveric temporal bones have become less available or unattainable in some institutions. This study investigates the suitability of an alternative model, using cadaveric lamb temporal bone, for surgical training of atraumatic round window electrode insertion. INTERVENTION A total of 14 lamb temporal bones were dissected for cochlear implantation by four surgeons. After mastoidectomy, visualization, and drilling of the round window niche, an atraumatic round window insertion of a Medel Flex24 electrode was performed. Electrode insertion depth and position were verified by computed tomography scans. MAIN OUTCOME MEASURE All cochleas were successfully implanted using the atraumatic round window approach; however, surgical access through the mastoid was substantially different when compared human anatomy. The mean number of intracochlear electrode contacts was 6.5 (range, 4-11) and the mean insertion depth 10.4 mm (range, 4-20 mm), which corresponds to a mean angular perimodiolar insertion depth of 229 degrees (range 67-540°). Full insertion of the electrode was not possible because of the smaller size of the lamb cochlea in comparison to that of the human. CONCLUSION The lamb temporal bone model is well suited as a training model for atraumatic cochlear implantation at the level of the round window. The minimally pneumatized mastoid as well as the smaller cochlea can help prepare a surgeon for difficult cochlear implantations. Because of substantial differences to human anatomy, it is not an adequate training model for other surgical techniques such as mastoidectomy and posterior tympanotomy as well as full electrode insertion.
Resumo:
The purpose of this practical manual is to describe and illustrate each step of the basic surgical procedures involved in the placement of implants in qualified patients. To that end, each procedure is briefly but lucidly described; carefully illustrated in a series of drawings of the techniques and instrumentation used; and reinforced through clinical photographs, including radiographic and postoperative follow-up views. In addition to the basic implant surgical principles, evidence-based indications and procedures for guided bone regeneration in apical fenestration and crestal dehiscence defects, and for simultaneous sinus floor elevation via the lateral window and osteotome techniques are featured.
Resumo:
The verification possibilities of dynamically collimated treatment beams with a scanning liquid ionization chamber electronic portal image device (SLIC-EPID) are investigated. The ion concentration in the liquid of a SLIC-EPID and therefore the read-out signal is determined by two parameters of a differential equation describing the creation and recombination of the ions. Due to the form of this equation, the portal image detector describes a nonlinear dynamic system with memory. In this work, the parameters of the differential equation were experimentally determined for the particular chamber in use and for an incident open 6 MV photon beam. The mathematical description of the ion concentration was then used to predict portal images of intensity-modulated photon beams produced by a dynamic delivery technique, the sliding window approach. Due to the nature of the differential equation, a mathematical condition for 'reliable leaf motion verification' in the sliding window technique can be formulated. It is shown that the time constants for both formation and decay of the equilibrium concentration in the chamber is in the order of seconds. In order to guarantee reliable leaf motion verification, these time constants impose a constraint on the rapidity of the image-read out for a given maximum leaf speed. For a leaf speed of 2 cm s(-1), a minimum image acquisition frequency of about 2 Hz is required. Current SLIC-EPID systems are usually too slow since they need about a second to acquire a portal image. However, if the condition is fulfilled, the memory property of the system can be used to reconstruct the leaf motion. It is shown that a simple edge detecting algorithm can be employed to determine the leaf positions. The method is also very robust against image noise.
Resumo:
OBJECTIVES: The objectives of this systematic review were to assess the survival rate of grafts and implants placed with sinus floor elevation. MATERIAL AND METHODS: An electronic search was conducted to identify studies on sinus floor elevation, with a mean follow-up time of at least 1 year after functional loading. RESULTS: The search provided 839 titles. Full-text analysis was performed for 175 articles resulting in 48 studies that met the inclusion criteria, reporting on 12,020 implants. Meta-analysis indicated an estimated annual failure rate of 3.48% [95% confidence interval (CI): 2.48%-4.88%] translating into a 3-year implant survival of 90.1% (95% CI: 86.4%-92.8%). However, when failure rates was analyzed on the subject level, the estimated annual failure was 6.04% (95% CI: 3.87%-9.43%) translating into 16.6% (95% CI: 10.9%-24.6%) of the subjects experiencing implant loss over 3 years. CONCLUSION: The insertion of dental implants in combination with maxillary sinus floor elevation is a predictable treatment method showing high implant survival rates and low incidences of surgical complications. The best results (98.3% implant survival after 3 years) were obtained using rough surface implants with membrane coverage of the lateral window.
Resumo:
A two-year-old female Lucerne Hound was presented with a one-week history of signs of progressive neck pain, inappetence, apathy, and an elevated rectal temperature. Findings of magnetic resonance imaging (MRI) were consistent with a foreign body abscess in the epidural space at the level of the first and second cervical vertebrae. A left-sided dorso-lateral atlantoaxial approach was performed, revealing an epidural abscess containing a grass awn. The clinical signs resolved within three days of surgery and the dog made a full recovery. This case report shows that grass awns can migrate to the atlantoaxial region in dogs and MRI findings lead to a suspicion of caudo-cranial migration within the spinal canal.
Resumo:
Mapping ecosystem services (ES) and their trade-offs is a key requirement for informed decision making for land use planning and management of natural resources that aim to move towards increasing the sustainability of landscapes. The negotiations of the purposes of landscapes and the services they should provide are difficult as there is an increasing number of stakeholders active at different levels with a variety of interests present on one particular landscape.Traditionally, land cover data is at the basis for mapping and spatial monitoring of ecosystem services. In light of complex landscapes it is however questionable whether land cover per se and as a spatial base unit is suitable for monitoring and management at the meso-scale. Often the characteristics of a landscape are defined by prevalence, composition and specific spatial and temporal patterns of different land cover types. The spatial delineation of shifting cultivation agriculture represents a prominent example of a land use system with its different land use intensities that requires alternative methodologies that go beyond the common remote sensing approaches of pixel-based land cover analysis due to the spatial and temporal dynamics of rotating cultivated and fallow fields.Against this background we advocate that adopting a landscape perspective to spatial planning and decision making offers new space for negotiation and collaboration, taking into account the needs of local resource users, and of the global community. For this purpose we introduce landscape mosaicsdefined as new spatial unit describing generalized land use types. Landscape mosaics have allowed us to chart different land use systems and land use intensities and permitted us to delineate changes in these land use systems based on changes of external claims on these landscapes. The underlying idea behindthe landscape mosaics is to use land cover data typically derived from remote sensing data and to analyse and classify spatial patterns of this land cover data using a moving window approach. We developed the landscape mosaics approach in tropical, forest dominated landscapesparticularly shifting cultivation areas and present examples ofour work from northern Laos, eastern Madagascarand Yunnan Province in China.
Resumo:
OBJECTIVE: Anatomic reduction and stable fixation by means of tissue- preserving surgical approaches. INDICATIONS Displaced acetabular fractures. Surgical hip dislocation approach with larger displacement of the posterior column in comparison to the anterior column, transtectal fractures, additional intraarticular fragments, marginal impaction. Stoppa approach with larger displacement of the anterior column in comparison to the posterior column. A combined approach might be necessary with difficult reduction. CONTRAINDICATIONS Fractures > 15 days (then ilioinguinal or extended iliofemoral approaches). Suprapubic catheters and abdominal problems (e.g., previous laparotomy due to visceral injuries) with Stoppa approach (then switch to classic ilioinguinal approach). SURGICAL TECHNIQUE: Surgical hip dislocation: lateral decubitus position. Straight lateral incision centered over the greater trochanter. Entering of the Gibson interval. Digastric trochanteric osteotomy with protection of the medial circumflex femoral artery. Opening of the interval between the piriformis and the gluteus minimus muscle. Z-shaped capsulotomy. Dislocation of the femoral head. Reduction and fixation of the posterior column with plate and screws. Fixation of the anterior column with a lag screw in direction of the superior pubic ramus. Stoppa approach: supine position. Incision according to Pfannenstiel. Longitudinal splitting of the anterior portion of the rectus sheet and the rectus abdominis muscle. Blunt dissection of the space of Retzius. Ligation of the corona mortis, if present. Blunt dissection of the quadrilateral plate and the anterior column. Reduction of the anterior column and fixation with a reconstruction plate. Fixation of the posterior column with lag screws. If necessary, the first window of the ilioinguinal approach can be used for reduction and fixation of the posterior column. POSTOPERATIVE MANAGEMENT: During hospital stay, intensive mobilization of the hip joint using a continuous passive motion machine with a maximum flexion of 90 degrees . No active abduction and passive adduction over the body's midline, if a surgical dislocation was performed. Maximum weight bearing 10-15 kg for 8 weeks. Then, first clinical and radiographic follow-up. Deep venous thrombosis prophylaxis for 8 weeks postoperatively. RESULTS: 17 patients with a mean follow-up of 3.2 years. Ten patients were operated via surgical hip dislocation, two patients with a Stoppa approach, and five using a combined or alternative approach. Anatomic reduction was achieved in ten of the twelve patients (83%) without primary total hip arthroplasty. Mean operation time 3.3 h for surgical hip dislocation and 4.2 h for the Stoppa approach. Complications comprised one delayed trochanteric union, one heterotopic ossification, and one loss of reduction. There were no cases of avascular necrosis. In two patients, a total hip arthroplasty was performed due to the development of secondary hip osteoarthritis.
Resumo:
The round window placement of a floating mass transducer (FMT) is a new approach for coupling an implantable hearing system to the cochlea. We evaluated the vibration transfer to the cochlear fluids of an FMT placed at the round window (rwFMT) with special attention to the role of bone conduction. A posterior tympanotomy was performed on eleven ears of seven human whole head specimens. Several rwFMT setups were examined using laser Doppler vibrometry measurements at the stapes and the promontory. In three ears, the vibrations of a bone anchored hearing aid (BAHA) and an FMT fixed to the promontory (pFMT) were compared to explore the role of bone conduction. Vibration transmission to the measuring point at the stapes was best when the rwFMT was perpendicularly placed in the round window and underlayed with connective tissue. Fixation of the rwFMT to the round window exhibited significantly lower vibration transmission. Although measurable, bone conduction from the pFMT was much lower than that of the BAHA. Our results suggest that the rwFMT does not act as a small bone anchored hearing aid, but instead, acts as a direct vibratory stimulator of the round window membrane.
Resumo:
With the placement of a floating mass transducer (FMT) at the round window, a new approach of coupling an implantable hearing system to the cochlea has been introduced. The aim of the present experimental study is to examine the influence of different ways of FMT placement at the round window on the vibration energy transfer to the cochlea.
Resumo:
AIM: To describe a method of carrying out apical surgery of a maxillary molar using ultrasonics to create a lateral sinus window into the maxillary sinus and an endoscope to enhance visibility during surgery. SUMMARY: A 37-year-old female patient presented with tenderness to percussion of the maxillary second right molar. Root canal treatment had been undertaken, and the tooth restored with a metal-ceramic crown. Radiological examination revealed an apical radiolucency in close proximity to the maxillary sinus. Apical surgery of the molar was performed through the maxillary sinus, using ultrasonics for the osteotomy, creating a window in the lateral wall of the maxillary sinus. During surgery, the lining of the sinus was exposed and elevated without perforation. The root-end was resected using a round tungsten carbide drill, and the root-end cavity was prepared with ultrasonic retrotips. Root-end filling was accomplished with MTA(®) . An endoscope was used to examine the cut root face, the prepared cavity and the root-end filling. No intraoperative or postoperative complications were observed. At the 12-month follow-up, the tooth had no clinical signs or symptoms, and the radiograph demonstrated progressing resolution of the radiolucency. KEY LEARNING POINTS: When conventional root canal retreatment cannot be performed or has failed, apical surgery may be considered, even in maxillary molars with roots in close proximity to the maxillary sinus. Ultrasonic sinus window preparation allows more control and can minimize perforation of the sinus membrane when compared with conventional rotary drilling techniques. The endoscope enhances visibility during endodontic surgery, thus improving the quality of the case.
Resumo:
Volumetric data at micrometer level resolution can be acquired within a few minutes using synchrotron-radiation-based tomographic microscopy. The field of view along the rotation axis of the sample can easily be increased by stacking several tomograms, allowing the investigation of long and thin objects at high resolution. On the contrary, an extension of the field of view in the perpendicular direction is non-trivial. This paper presents an acquisition protocol which increases the field of view of the tomographic dataset perpendicular to its rotation axis. The acquisition protocol can be tuned as a function of the reconstruction quality and scanning time. Since the scanning time is proportional to the radiation dose imparted to the sample, this method can be used to increase the field of view of tomographic microscopy instruments while optimizing the radiation dose for radiation-sensitive samples and keeping the quality of the tomographic dataset on the required level. This approach, dubbed wide-field synchrotron radiation tomographic microscopy, can increase the lateral field of view up to five times. The method has been successfully applied for the three-dimensional imaging of entire rat lung acini with a diameter of 4.1 mm at a voxel size of 1.48 microm.
Resumo:
The aim of this study is to review the results and clinical outcome of patients with surgically treated lesions within the trigone of the lateral ventricle. This is a retrospective case series of 20 (eight male, 12 female) patients with lesions of the trigone of the lateral ventricle operated between 1998 and 2008. All lesions were removed via the transcortical temporal and transcortical parietal route. Surgical complications and outcome were assessed using the modified Rankin Scale (mRS). There were four children and 16 adults with a mean age of 42?±?22 years (min?=?1, max?=?74). Eight (40%) lesions grew within the trigone of the dominant hemisphere. In 17 cases, the lesion was purely intraventricular, and in three cases, a slight paraventricular extension was seen. The mean size was 4.5 cm of maximal diameter. Surgical removal was achieved via the transcortical parietal route in 13 cases (65%) and the transcortical temporal route in seven cases (35%). In all cases, complete resection was possible. According to the mRS, 13 patients improved, five remained the same, and two were lost to follow-up. One patient had an increased visual field deficit postoperatively and new hemiparesis and aphasia, but returned to the preoperative level within a few weeks. In one patient, an acute myocardial infarction occurred due to previous cardiac stent placement and in-stent stenosis. Even large trigonal lesions can be resected with low morbidity using a transcortical approach depending on the peritrigonal extension of the tumor.
Resumo:
A new anterior intrapelvic approach for the surgical management of displaced acetabular fractures involving predominantly the anterior column and the quadrilateral plate is described. In order to establish five 'windows' for instrumentation, the extraperitoneal space is entered along the lateral border of the rectus abdominis muscle. This is the so-called 'Pararectus' approach. The feasibility of safe dissection and optimal instrumentation of the pelvis was assessed in five cadavers (ten hemipelves) before implementation in a series of 20 patients with a mean age of 59 years (17 to 90), of whom 17 were male. The clinical evaluation was undertaken between December 2009 and December 2010. The quality of reduction was assessed with post-operative CT scans and the occurrence of intra-operative complications was noted. In cadavers, sufficient extraperitoneal access and safe instrumentation of the pelvis were accomplished. In the patients, there was a statistically significant improvement in the reduction of the fracture (pre- versus post-operative: mean step-off 3.3 mm (sd 2.6) vs 0.1 mm (sd 0.3), p < 0.001; and mean gap 11.5 mm (sd 6.5) vs 0.8 mm (sd 1.3), p < 0.001). Lesions to the peritoneum were noted in two patients and minor vascular damage was noted in a further two patients. Multi-directional screw placement and various plate configurations were feasible in cadavers without significant retraction of soft tissues. In the treatment of acetabular fractures predominantly involving the anterior column and the quadrilateral plate, the Pararectus approach allowed anatomical restoration with minimal morbidity related to the surgical access.