50 resultados para Kinematic

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Focal spasticity is a significant motor disorder following stroke, and Botulinum Toxin Type-A (BoNT-A) is a useful treatment for this. The authors evaluated kinematic modifications induced by spasticity, and whether or not there is any improvement following injection of BoNT-A. Methods Eight patients with stroke with upper-limb spasticity, showing a flexor pattern, were evaluated using kinematics before and after focal treatment with BoNT-A. A group of sex- and age-matched normal volunteers acted as a control group. Results Repeated-measures ANOVA showed that patients with stroke performed more slowly than the control group. Following treatment with BoNT-A, there was a significant improvement in kinematics in patients with stroke, while in the control group, performance remained unchanged. Conclusions Focal treatment of spasticity with BoNT-A leads to an adaptive change in the upper limb of patients with spastic stroke.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selective dorsal rhizotomy (SDR) is an effective treatment for reducing spasticity and improving gait in children with spastic cerebral palsy. Data concerning muscle activity changes after SDR treatment are limited.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aims of this study were to examine the clinical feasibility and reproducibility of kinematic MR imaging with respect to changes in T (2) in the femoral condyle articular cartilage. We used a flexible knee coil, which allows acquisition of data in different positions from 40 degrees flexion to full extension during MR examinations. The reproducibility of T (2) measurements was evaluated for inter-rater and inter-individual variability and determined as a coefficient of variation (CV) for each volunteer and rater. Three different volunteers were measured twice and regions of interest (ROIs) were selected by three raters at different time points. To prove the clinical feasibility of this method, 20 subjects (10 patients and 10 age- and sex-matched volunteers) were enrolled in the study. Inter-rater variability ranged from 2 to 9 and from 2 to 10% in the deep and superficial zones, respectively. Mean inter-individual variability was 7% for both zones. Different T (2) values were observed in the superficial cartilage zone of patients compared with volunteers. Since repair tissue showed a different behavior in the contact zone compared with healthy cartilage, a possible marker for improved evaluation of repair tissue quality after matrix-associated autologous chondrocyte transplantation (MACT) may be available and may allow biomechanical assessment of cartilage transplants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pressure–Temperature–time (P–T–t) estimates of the syn-kinematic strain at the peak-pressure conditions reached during shallow underthrusting of the Briançonnais Zone in the Alpine subduction zone was made by thermodynamic modelling and 40Ar/39Ar dating in the Plan-de-Phasy unit (SE of the Pelvoux Massif, Western Alps). The dated phengite minerals crystallized syn-kinematically in a shear zone indicating top-to-the-N motion. By combining X-ray mapping with multi-equilibrium calculations, we estimate the phengite crystallization conditions at 270 ± 50 °C and 8.1 ± 2 kbar at an age of 45.9 ± 1.1 Ma. Combining this P–T–t estimate with data from the literature allows us to constrain the timing and geometry of Alpine continental subduction. We propose that the Briançonnais units were scalped on top of the slab during ongoing continental subduction and exhumed continuously until collision.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mechanical properties of human trabecular bone play an important role in age-related bone fragility and implant stability. Micro-finite element (microFE) analysis allows computing the apparent elastic properties of trabecular bone biopsies, but the results depend on the type of applied boundary conditions (BCs). In this study, 167 femoral trabecular cubic biopsies with a side length of 5.3 mm were analyzed using microFE analysis to compare their stiffness systematically with kinematic uniform boundary conditions (KUBCs) and periodicity-compatible mixed uniform boundary conditions (PMUBCs). The obtained elastic constants were then used in the volume fraction and fabric-based orthotropic Zysset-Curnier model to identify their respective model parameters. As expected, PMUBCs lead to more compliant apparent elastic properties than KUBCs, especially in shear. The differences in stiffness decreased with bone volume fraction and mean intercept length. Unlike KUBCs, PMUBCs were sensitive to heterogeneity of the biopsies. The Zysset-Curnier model predicted apparent elastic constants successfully in both cases with adjusted coefficients of determination of 0.986 for KUBCs and 0.975 for PMUBCs. The role of these boundary conditions in finite element analyses of whole bones and bone-implant systems will need to be investigated in future work.