8 resultados para Juan, Jorge, 1713-1773-Llibres per a infants
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
In Switzerland, children are prescribed 7.5-12.5 μg per day of vitamin D(3) dissolved in alcohol, but many families do not adhere to the recommendation. The aim of the trial was to compare the acceptance of vitamin D(3) dissolved in alcohol or in medium-chain triglycerides among mothers of Swiss newborn infants. The acceptance was tested in 42 healthy newborn infants (20 girls and 22 boys) aged between 2 and 7 days. Their neonatal body weight ranged between 2.225 and 4.150 kg, and the gestational age between 36 1/7 and 41 3/7 weeks. The blinded mothers rated the facial reaction of their children by pointing on a facial hedonic scale. Thirty eight of the 41 mothers, who brought the comparison to completion, assigned a better score to the oily preparation with no difference in the remaining three cases (P < 0.0001). The acceptance for the oily preparation was significantly better both among mothers whose babies were initially presented the alcoholic preparation and among mothers whose babies were initially presented the oily preparation. Furthermore, the acceptance for the oily preparation was better irrespective of gender of the infant or parity of the mother. In conclusion, from the perspective of mothers, Swiss newborn infants prefer the taste of the oily vitamin D(3) preparation over the alcoholic preparation.
A prospective study of the impact of air pollution on respiratory symptoms and infections in infants
Resumo:
Rationale: There is increasing evidence that short-term exposure to air pollution has a detrimental effect on respiratory health, but data from healthy populations, particularly infants, are scarce. Objectives: To assess the association of air pollution with frequency and severity of respiratory symptoms and infections measured weekly in healthy infants. Methods: In a prospective birth cohort of 366 infants of unselected mothers, respiratory health was assessed weekly by telephone interviews during the first year of life (19,106 total observations). Daily mean levels of particulate matter (PM10), nitrogen dioxide (NO2), and ozone (O3) were obtained from local monitoring stations. We determined the association of the preceding week's pollutant levels with symptom scores and respiratory tract infections using a generalized additive mixed model with an autoregressive component. In addition, we assessed whether neonatal lung function influences this association and whether duration of infectious episodes differed between weeks with normal PM10 and weeks with elevated levels. Measurements and Main Results: We found a significant association between air pollution and respiratory symptoms, particularly in the week after respiratory tract infections (risk ratio, 1.13 [1.02-1.24] per 10 μg/m(3) PM10 levels) and in infants with premorbid lung function. During times of elevated PM10 (>33.3 μg/m(3)), duration of respiratory tract infections increased by 20% (95% confidence interval, 2-42%). Conclusions: Exposure to even moderate levels of air pollution was associated with increased respiratory symptoms in healthy infants. Particularly in infants with premorbid lung function and inflammation, air pollution contributed to longer duration of infectious episodes with a potentially large socioeconomic impact.
Resumo:
OBJECTIVES: Ventilated preterm infants are at high risk for procedural pain exposure. In Switzerland there is a lack of knowledge about the pain management in this highly vulnerable patient population. The aims of this study were to describe the type and frequency of procedures and to determine the amount of analgesia given to this patient group in two Swiss neonatal intensive care units. METHOD: A retrospective cohort study was performed examining procedural exposure and pain management of a convenience sample of 120 ventilated preterm infants (mean age = 29.7 weeks of gestation) during the first 14 days of life after delivery and born between May 1st 2004 and March 31st 2006. RESULTS: The total number of procedures all the infants underwent was 38,626 indicating a mean of 22.9 general procedures performed per child and day. Overall, 75.6% of these procedures are considered to be painful. The most frequently performed procedure is manipulation on the CPAP prongs. Pain measurements were performed four to seven times per day. In all, 99.2% of the infants received either non-pharmacological and/or pharmacological agents and 70.8% received orally administered glucose as pre-emptive analgesia. Morphine was the most commonly used pharmacological agent. DISCUSSION: The number of procedures ventilated preterm infants are exposed to is disconcerting. Iatrogenic pain is a serious problem, particularly in preterm infants of low gestational age. The fact that nurses assessed pain on average four to seven times daily per infant indicates a commitment to exploring a painful state in a highly vulnerable patient population. In general, pharmacological pain management and the administration of oral glucose as a non-pharmacological pain relieving intervention appear to be adequate, but there may be deficiencies, particularly for extremely low birth weight infants born <28 weeks of gestation.
Resumo:
BACKGROUND Nitrogen multiple-breath washout (N2 MBW) using 100% oxygen (O2 ) has regained interest to assess efficiency of tracer gas clearance in, for example, children with Cystic Fibrosis (CF). However, the influence of hyperoxia on the infants' respiratory control is unclear. We assessed safety and impact on breathing pattern from hyperoxia, and if exposure to 40% O2 first induces tolerance to subsequent 100% O2 for N2 MBW. METHODS We prospectively enrolled 39 infants aged 3-57 weeks: 15 infants with CF (8 sedated for testing) and 24 healthy controls. Infants were consecutively allocated to the protocols comprising of 100% O2 or 40/100% O2 administered for 30 breaths. Lung function was measured using an ultrasonic flowmeter setup. Primary outcome was tidal volume (VT ). RESULTS None of the infants experienced apnea, desaturation, or bradycardia. Both protocols initially induced hypoventilation. VT temporarily declined in 33/39 infants across 10-25 breaths. Hypoventilation occurred independent of age, disease, and sedation. In the new 40/100% O2 protocol, VT returned to baseline during 40% O2 and remained stable during 100% O2 exposure. End-tidal carbon dioxide monitored online did not change. CONCLUSION The classical N2 MBW protocol with 100% O2 may change breathing patterns of the infants. The new protocol with 40% O2 induces hyperoxia-tolerance and does not lead to changes in breathing patterns during later N2 washout using 100% O2 . Both protocols are safe, the new protocol seems an attractive option for N2 MBW in infants. Pediatr Pulmonol. © 2013 Wiley Periodicals, Inc.
Resumo:
INTRODUCTION The new ATS/ERS consensus report recommends in vitro validation of multiple-breath inert gas washout (MBW) equipment based on a lung model with simulated physiologic conditions. We aimed to assess accuracy of two MBW setups for infants and young children using this model, and to compare functional residual capacity (FRC) from helium MBW (FRCMBW ) with FRC from plethysmography (FRCpleth ) in vivo. METHODS The MBW setups were based on ultrasonic flow meter technology. Sulfur hexafluoride and helium were used as tracer gases. We measured FRC in vitro for specific model settings with and without carbon dioxide and calculated differences of measured to generated FRC. For in vivo evaluation, difference between FRCMBW and FRCpleth was calculated in 20 healthy children, median age 6.1 years. Coefficient of variation (CV) was calculated per FRC. RESULTS In the infant model (51 runs, FRC 80-300 ml), mean (SD) relative difference between generated and measured FRCs was 0.7 (4.7) %, median CV was 4.4% for measured FRCs. In the young child model, one setting (8 runs, FRC 400 ml) showed a relative difference of up to 13%. For the remaining FRCs (42 runs, FRC 600-1,400 ml), mean (SD) relative difference was -2.0 (3.4) %; median CV was 1.4% for measured FRCs. In vivo FRCpleth exceeded FRCMBW values by 37% on average. CONCLUSIONS Both setups measure lung volumes in the intended age group reliably and reproducibly. Characteristics of different techniques should be considered when measuring lung volumes in vivo. Pediatr Pulmonol. © 2014 Wiley Periodicals, Inc.
Resumo:
INTRODUCTION Monitoring breathing pattern is especially relevant in infants with lung disease. Recently, a vest-based inductive plethysmograph system (FloRight®) has been developed for tidal breathing measurement in infants. We investigated the accuracy of tidal breathing flow volume loop (TBFVL) measurements in healthy term-born infants and infants with lung disease by the vest-based system in comparison to an ultrasonic flowmeter (USFM) with a face mask. We also investigated whether the system discriminates between healthy infants and those with lung disease. METHODS Floright® measures changes in thoracoabdominal volume during tidal breathing through magnetic field changes generated by current-carrying conductor coils in an elastic vest. Simultaneous TBFVL measurements by the vest-based system and the USFM were performed at 44 weeks corrected postmenstrual age during quiet unsedated sleep. TBFVL parameters derived by both techniques and within both groups were compared. RESULTS We included 19 healthy infants and 18 infants with lung disease. Tidal volume per body weight derived by the vest-based system was significantly lower with a mean difference (95% CI) of -1.33 ml/kg (-1.73; -0.92), P < 0.001. Respiratory rate and ratio of time to peak tidal expiratory flow over total expiratory time (tPTEF/tE) did not differ between the two techniques. Both systems were able to discriminate between healthy infants and those with lung disease using tPTEF/tE. CONCLUSION FloRight® accurately measures time indices and may discriminate between healthy infants and those with lung disease, but demonstrates differences in tidal volume measurements. It may be better suited to monitor breathing pattern than for TBFVL measurements.