10 resultados para Joint Position Sense
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
PURPOSE: To determine the reproducibility and validity of video screen measurement (VSM) of sagittal plane joint angles during gait. METHODS: 17 children with spastic cerebral palsy walked on a 10m walkway. Videos were recorded and 3d-instrumented gait analysis was performed. Two investigators measured six sagittal joint/segment angles (shank, ankle, knee, hip, pelvis, and trunk) using a custom-made software package. The intra- and interrater reproducibility were expressed by the intraclass correlation coefficient (ICC), standard error of measurements (SEM) and smallest detectable difference (SDD). The agreement between VSM and 3d joint angles was illustrated by Bland-Altman plots and limits of agreement (LoA). RESULTS: Regarding the intrarater reproducibility of VSM, the ICC ranged from 0.99 (shank) to 0.58 (trunk), the SEM from 0.81 degrees (shank) to 5.97 degrees (trunk) and the SDD from 1.80 degrees (shank) to 16.55 degrees (trunk). Regarding the interrater reproducibility, the ICC ranged from 0.99 (shank) to 0.48 (trunk), the SEM from 0.70 degrees (shank) to 6.78 degrees (trunk) and the SDD from 1.95 degrees (shank) to 18.8 degrees (trunk). The LoA between VSM and 3d data ranged from 0.4+/-13.4 degrees (knee extension stance) to 12.0+/-14.6 degrees (ankle dorsiflexion swing). CONCLUSION: When performed by the same observer, VSM mostly allows the detection of relevant changes after an intervention. However, VSM angles differ from 3d-IGA and do not reflect the real sagittal joint position, probably due to the additional movements in the other planes.
Resumo:
This article is aimed at addressing the current state of the art in epidemiology, pathophysiology, diagnostic procedures and treatment options for appropriate management of obstructive sleep apnea (OSA) in cardiovascular (particularly hypertensive) patients, as well as for the management of cardiovascular diseases (particularly arterial hypertension) in OSA patients. The present document is the result of the work done by a panel of experts participating in the European Union COST (COoperation in Scientific and Technological research) ACTION B26 on OSA, with the endorsement of the European Respiratory Society (ERS) and the European Society of Hypertension (ESH). These recommendations are particularly aimed at reminding cardiovascular experts to consider the occurrence of sleep-related breathing disorders in patients with high blood pressure. They are at the same time aimed at reminding respiration experts to consider the occurrence of hypertension in patients with respiratory problems at night.
Resumo:
Based on current data and experience, the joint working group of the European Society of Minimally Invasive Neurological Therapy (ESMINT) and the European Society of Neuroradiology (ESNR) make suggestions on trial design and conduct aimed to investigate therapeutic effects of mechanical thrombectomy (MT). We anticipate that this roadmap will facilitate the setting up and conduct of successful trials in close collaboration with our neighbouring disciplines.
Resumo:
Deformity and malposition of the acetabulum can occur during the development of the hip. Developmental hip dysplasia and acetabular retroversion are possible causes of osteoarthritis in the young adult. Surgical management with reorientation of the acetabulum allows causal therapy of the deformity and preservation of the native hip joint. Established techniques are the Bernese periacetabular osteotomy (PAO) and the Tönnis and Kalchschmidt triple osteotomy of the pelvis. Both techniques permit three-dimensional correction of the position of the acetabulum. Advantages and disadvantages of each technique must be considered and are summarized in the present paper. If performed early (osteoarthritis grade Tönnis 0 and 1) with correct indication and proper technique, good results can be expected.
Resumo:
BACKGROUND: Chronic neck pain after whiplash injury is caused by cervical zygapophysial joints in 50% of patients. Diagnostic blocks of nerves supplying the joints are performed using fluoroscopy. The authors' hypothesis was that the third occipital nerve can be visualized and blocked with use of an ultrasound-guided technique. METHODS: In 14 volunteers, the authors placed a needle ultrasound-guided to the third occipital nerve on both sides of the neck. They punctured caudal and perpendicular to the 14-MHz transducer. In 11 volunteers, 0.9 ml of either local anesthetic or normal saline was applied in a randomized, double-blind, crossover manner. Anesthesia was controlled in the corresponding skin area by pinprick and cold testing. The position of the needle was controlled by fluoroscopy. RESULTS: The third occipital nerve could be visualized in all subjects and showed a median diameter of 2.0 mm. Anesthesia was missing after local anesthetic in only one case. There was neither anesthesia nor hyposensitivity after any of the saline injections. The C2-C3 joint, in a transversal plane visualized as a convex density, was identified correctly by ultrasound in 27 of 28 cases, and 23 needles were placed correctly into the target zone. CONCLUSIONS: The third occipital nerve can be visualized and blocked with use of an ultrasound-guided technique. The needles were positioned accurately in 82% of cases as confirmed by fluoroscopy; the nerve was blocked in 90% of cases. Because ultrasound is the only available technique today to visualize this nerve, it seems to be a promising new method for block guidance instead of fluoroscopy.
Resumo:
A joint reprocessing of GPS, GLONASS and SLR observations has been carried out at TU Dresden, TU Munich, AIUB and ETH Zurich. Common a priori models have been applied for the processing of all types of observation to ensure both consistent parameter estimates and the rigorous combination of microwave and optical measurements. Based on that reprocessing results, we evaluate the impact of adding GLONASS observations to the standard GPS data processing. In particular, changes in station position time series and day boundary overlaps of consecutive satellite arcs are analyzed. In addition, the GNSS orbits derived from microwave measurements are validated using independent SLR range measurements. Our SLR residuals indicate a significant improvement compared to previous results. Furthermore, we evaluate the performance of our high-rate (30s) combined GNSS satellite clocks and discuss associated zero-difference phase residuals.
Resumo:
In absence of basic canine hip biomechanics, a specific, consequent three dimensional concept to evaluate the coxofemoral joint was developed for the dog. With the help of a new method to radiologically demonstrate the hip in a physiological standing position several new clinically relevant aspects could be further investigated. For example the breed specific anatomical differences in the hip, and dynamics and the background on "iatrogenic luxations" in HD diagnostics could be shown. The caudal luxation and the growth abnormalities of the hip and their consequences on the whole leg (antetorsion syndrome) as a consequence of inadequate breeding could be demonstrated.
Resumo:
Twenty-eight feline pelves (56 hemipelves) were examined in order to identify the location for optimal sacroiliac screw placement in sacroiliac fracture-luxation repair. A drill hole was started on the median plane of the hemipelvis in the centre of the body of the first sacral segment until it penetrated the lateral cortex of the ilial wing, thus providing optimal drill hole placement. The position of the drill hole on the articular surface of the sacral wing and on the lateral surface of the ilial wing was measured. The distance of the drill hole from the cranial margin of the sacral wing was 51% of sacral wing length, just cranial to the crescent shaped hyaline cartilage. The distance from the dorsal margin was 47% of sacral wing height. The drill bit direction has to be adjusted to the cranio-caudal inclination (range 10° to 29°) and dorso-ventral inclination (range 2° to 25°) of the sacral wing. A notch in the cranial edge of the sacral wing was present, with variable position, in 34% of the specimens and is consequently not a useful landmark for sacroiliac screw placement. The drill hole on the lateral surface of the ilium was located in craniocaudal direction at a distance of 69% of sacral tuber length, measured from the cranial dorsal iliac spine. The dorso-ventral position of the drill hole was at a distance of 52% of ilial wing height measured from the sacral tuber. The ventral gluteal line, present in 93% of the cases, is a useful landmark to locate optimal screw hole position on the ilial wing.
Resumo:
AIM To systematically search the literature and assess the available evidence for the influence of chin-cup therapy on the temporomandibular joint regarding morphological adaptations and appearance of temporomandibular disorders (TMD). MATERIALS AND METHODS Electronic database searches of published and unpublished literature were performed. The following electronic databases with no language and publication date restrictions were searched: MEDLINE (via Ovid and PubMed), EMBASE (via Ovid), the Cochrane Oral Health Group's Trials Register, and CENTRAL. Unpublished literature was searched on ClinicalTrials.gov, the National Research Register, and Pro-Quest Dissertation Abstracts and Thesis database. The reference lists of all eligible studies were checked for additional studies. Two review authors performed data extraction independently and in duplicate using data collection forms. Disagreements were resolved by discussion or the involvement of an arbiter. RESULTS From the 209 articles identified, 55 papers were considered eligible for inclusion in the review. Following the full text reading stage, 12 studies qualified for the final review analysis. No randomized clinical trial was identified. Eight of the included studies were of prospective and four of retrospective design. All studies were assessed for their quality and graded eventually from low to medium level of evidence. Based on the reported evidence, chin-cup therapy affects the condylar growth pattern, even though two studies reported no significance changes in disc position and arthrosis configuration. Concerning the incidence of TMD, it can be concluded from the available evidence that chin-cup therapy constitutes no risk factor for TMD. CONCLUSION Based on the available evidence, chin-cup therapy for Class III orthodontic anomaly seems to induce craniofacial adaptations. Nevertheless, there are insufficient or low-quality data in the orthodontic literature to allow the formulation of clear statements regarding the influence of chin-cup treatment on the temporomandibular joint.
Resumo:
OBJECTIVE Intraarticular gadolinium-enhanced magnetic resonance arthrography (MRA) is commonly applied to characterize morphological disorders of the hip. However, the reproducibility of retrieving anatomic landmarks on MRA scans and their correlation with intraarticular pathologies is unknown. A precise mapping system for the exact localization of hip pathomorphologies with radial MRA sequences is lacking. Therefore, the purpose of the study was the establishment and validation of a reproducible mapping system for radial sequences of hip MRA. MATERIALS AND METHODS Sixty-nine consecutive intraarticular gadolinium-enhanced hip MRAs were evaluated. Radial sequencing consisted of 14 cuts orientated along the axis of the femoral neck. Three orthopedic surgeons read the radial sequences independently. Each MRI was read twice with a minimum interval of 7 days from the first reading. The intra- and inter-observer reliability of the mapping procedure was determined. RESULTS A clockwise system for hip MRA was established. The teardrop figure served to determine the 6 o'clock position of the acetabulum; the center of the greater trochanter served to determine the 12 o'clock position of the femoral head-neck junction. The intra- and inter-observer ICCs to retrieve the correct 6/12 o'clock positions were 0.906-0.996 and 0.978-0.988, respectively. CONCLUSIONS The established mapping system for radial sequences of hip joint MRA is reproducible and easy to perform.