31 resultados para Intubation
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
We present the use of the SensaScope, an S-shaped rigid fibreoptic scope with a flexible distal end, in a series of 13 patients at high risk of, or known to have, a difficult intubation. Patients received conscious sedation with midazolam or fentanyl combined with a remifentanil infusion and topical lidocaine to the oral mucosa and to the trachea via a trans-cricoid injection. Spontaneous ventilation was maintained until confirmation of tracheal intubation. In all cases, tracheal intubation was achieved using the SensaScope. The median (IQR [range]) insertion time (measured from the time the facemask was taken away from the face until an end-expiratory CO(2) reading was visible on the monitor) was 58 s (38-111 [28-300]s). In nine of the 13 cases, advancement of the SensaScope into the trachea was easy. Difficulties included a poor view associated with a bleeding diathesis and saliva, transient loss of spontaneous breathing, and difficulty in advancing the tracheal tube in a patient with unforeseen tracheal narrowing. A poor view in two patients was partially improved by a high continuous flow of oxygen. The SensaScope may be a valuable alternative to other rigid or flexible fibreoptic scopes for awake intubation of spontaneously breathing patients with a predicted difficult airway.
Resumo:
The i-gel™ is a single-use supraglottic airway device (SAD) that allows fibreoptic-guided tracheal intubation through the device. Until now, no prospective data for this procedure are available. Therefore, in a prospective randomized controlled trial, we evaluated fibreoptic-guided tracheal intubation with a standard Rüsch™ PVC tracheal tube (TT) through the i-gel™ compared with the single-use ILMA™ (sILMA™) TT through the sILMA™ in patients with a predicted difficult airway.
Resumo:
The single-use supraglottic airway device i-gel™ has been described in several case reports as a conduit for intubation, but no prospective data about success rates of blind intubation are available. Therefore, we performed this prospective randomized controlled trial to compare the success rate of blind tracheal intubation with a Magill PVC tube through the i-gel™ with intubation using an sILMA™ PVC tube through the single-use intubating laryngeal mask airway (sILMA™).
Resumo:
Mechanical ventilation (MV) is life-saving but potentially harmful for lungs of premature infants. So far, animal models dealt with the acute impact of MV on immature lungs, but less with its delayed effects. We used a newborn rodent model including non-surgical and therefore reversible intubation with moderate ventilation and hypothesized that there might be distinct gene expression patterns after a ventilation-free recovery period compared to acute effects directly after MV. Newborn rat pups were subjected to 8 hr of MV with 60% oxygen (O(2)), 24 hr after injection of lipopolysaccharide (LPS), intended to create a low inflammatory background as often recognized in preterm infants. Animals were separated in controls (CTRL), LPS injection (LPS), or full intervention with LPS and MV with 60% O(2) (LPS + MV + O(2)). Lungs were recovered either directly following (T:0 hr) or 48 hr after MV (T:48 hr). Histologically, signs of ventilator-induced lung injury (VILI) were observed in LPS + MV + O(2) lungs at T:0 hr, while changes appeared similar to those known from patients with chronic lung disease (CLD) with fewer albeit larger gas exchange units, at T:48 hr. At T:0 hr, LPS + MV + O(2) increased gene expression of pro-inflammatory MIP-2. In parallel anti-inflammatory IL-1Ra gene expression was increased in LPS and LPS + MV + O(2) groups. At T:48 hr, pro- and anti-inflammatory genes had returned to their basal expression. MMP-2 gene expression was decreased in LPS and LPS + MV + O(2) groups at T:0 hr, but no longer at T:48 hr. MMP-9 gene expression levels were unchanged directly after MV. However, at T:48 hr, gene and protein expression increased in LPS + MV + O(2) group. In conclusion, this study demonstrates the feasibility of delayed outcome measurements after a ventilation-free period in newborn rats and may help to further understand the time-course of molecular changes following MV. The differences obtained from the two time points could be interpreted as an initial transitory increase of inflammation and a delayed impact of the intervention on structure-related genes.
Resumo:
Video-laryngoscopes are marketed for intubation in difficult airway management. They provide a better view of the larynx and may facilitate tracheal intubation, but there is no adequately powered study comparing different types of video-laryngoscopes in a difficult airway scenario or in a simulated difficult airway situation.
Resumo:
BACKGROUND: Hypnotic depth but not haemodynamic response to painful stimulation can be measured with various EEG-based anaesthesia monitors. We evaluated the variation of pulse plethysmography amplitude induced by an electrical tetanic stimulus (PPG variation) as a potential measure for analgesia and predictor of haemodynamic responsiveness during general anaesthesia. METHODS: Ninety-five patients, ASA I or II, were randomly assigned to five groups [Group 1: bispectral index (BIS) (range) 40-50, effect site remifentanil concentration 1 ng ml(-1);Group 2: BIS 40-50, remifentanil 2 ng ml(-1); Group 3: BIS 40-50, remifentanil 4 ng ml(-1); Group 4: BIS 25-35, remifentanil 2 ng ml(-1); Group 5: BIS 55-65, remifentanil 2 ng ml(-1)]. A 60 mA tetanic stimulus was applied for 5 s on the ulnar nerve. From the digitized pulse oximeter wave recorded on a laptop computer, linear and non-linear parameters of PPG variation during the 60 s period after stimulation were computed. The haemodynamic response to subsequent orotracheal intubation was recorded. The PPG variation was compared between groups and between responders and non-responders to intubation (anova). Variables independently predicting the response were determined by logistic regression. RESULTS: The probability of a response to tracheal intubation was 0.77, 0.47, 0.05, 0.18 and 0.52 in Groups 1-5, respectively (P<0.03). The PPG variability was significantly higher in responders than in non-responders but it did not improve the prediction of the response to tracheal intubation based on BIS level and effect site remifentanil concentration. CONCLUSION: Tetanic stimulation induced PPG variation does not reflect the analgesic state in a wide clinical range of surgical anaesthesia.
Resumo:
Airway access is needed for a number of experimental animal models, and the majority of animal research is based on mouse models. Anatomical conditions in mice are small, and the narrow glottic opening allows intubation only with a subtle technique. We therefore developed a microscopic endotracheal intubation method with a wire guide technique in mice anaesthetized with halothane in oxygen. The mouse is hung perpendicularly with its incisors on a thread fixed on a vertical plate. The tongue is placed with a pair of forceps between the left hand's thumb and forefinger and slightly pulled, while the neck and thorax are positioned using the third and fourth fingers. By doing so, the neck can be slightly stretched, which allows optimal visualization of the larynx and the vocal cords. To ensure a safe intubation, a fine wire guide is placed under vision between the vocal cords and advanced about 5 mm into the trachea. An intravenous 22G x 1 in. plastic or Teflon catheter is guided over this wire. In a series of 41 mice, between 21 and 38 g, the success rate for the first intubation attempt was >95%. Certainty of the judgement procedure was 100% and success rate was higher using the described method when compared with a transillumination method in a further series. The technique is safe, less invasive than tracheostomy and suitable for controlled ventilation and pulmonary substance application.
Resumo:
BACKGROUND Paediatric supraglottic airway devices AmbuAura-i and Air-Q were designed as conduits for tracheal intubation. Although fibreoptic-guided intubation has proved successful, blind intubation as a rescue technique has never been evaluated. OBJECTIVE Evaluation of blind intubation through AmbuAura-i and Air-Q. On the basis of fibreoptic view data, we hypothesised that the success rate with the AmbuAura-i would be higher than with the Air-Q. DESIGN A prospective, randomised controlled trial with institutional review board (IRB) approval and written informed consent. SETTING University Childrens' Hospital; September 2012 to July 2014. PATIENTS Eighty children, American Society of Anesthesiologists (ASA) class I to III, weight 5 to 50 kg. INTERVENTIONS Tracheal intubation was performed through the randomised device with the tip of a fibrescope placed inside and proximal to the tip of the tracheal tube. This permitted sight of tube advancement, but without fibreoptic guidance (visualised blind intubation). MAIN OUTCOME MEASURES Primary outcome was successfully visualised blind intubation; secondary outcomes included supraglottic airway device success, insertion times, airway leak pressure, fibreoptic view and adverse events. RESULTS Personal data did not differ between groups. In contrast to our hypothesis, blind intubation was possible in 15% with the Air-Q and in 3% with the AmbuAura-i [95% confidence interval (95% CI) 6 to 31 vs. 0 to 13%; P = 0.057]. First attempt supraglottic airway device insertion success rates were 95% (Air-Q) and 100% (AmbuAura-i; 95% CI 83 to 99 vs. 91 to 100; P = 0.49). Median leak pressures were 18 cmH2O (Air-Q) and 17 cmH2O [AmbuAura-i; interquartile range (IQR) 14 to 18 vs. 14 to 19 cmH2O; P = 0.66]. Air-Q insertion was slower (27 vs. 19 s, P < 0.001). There was no difference in fibreoptic view, or adverse events (P > 0.05). In one child (Air-Q size 1.5, tube size 3.5), the tube dislocated during device removal. CONCLUSION Ventilation with both devices is reliable, but success of blind intubation is unacceptably low and cannot be recommended for elective or rescue purposes. If intubation through a paediatric supraglottic airway device is desired, we suggest that fibreoptic guidance is used. TRIAL REGISTRATION Clinicaltrials.gov identifier: NCT01692522.
Resumo:
INTRODUCTION Evidence concerning delivery room management in extremely low birth weight infants (ELBW) has grown substantially within the last 20 years, leading to several guidelines and recommendations. However, it is unknown in which extent local treatment strategies have changed and if they reflect current recommendations. METHODS A detailed questionnaire about treatment strategies for ELBW infants was sent to all German neonatal intensive care units (NICUs) treating ELBW infants in 1997. A follow-up survey was conducted in 2011 and sent to all NICUs in Germany, Austria and Switzerland. RESULTS on delivery room management were compared to the first survey. RESULTS In 1997 and 2011, 63.6 and 66.2% of the approached hospitals responded. In 2011 similar results were observed between university and non-university hospitals as well as NICUs of different size. Differences between Germany, Austria and Switzerland were minimal. Changes over time were a lower initially applied fraction of inspired oxygen (FiO2) and peak inspiratory pressure (PiP) in 2011 compared to 1997. A longer time of apnea was tolerated before tracheal intubation is performed; the time of apnea was less frequently a sole criterion for intubation and surfactant was applied at lower FiO2 in 2011. The time of no thorax excursions and transport of the infant were considered an indication for intubation in 30.2 and 22.5%, and did not change in the observation period. CONCLUSION Treatment strategies for delivery room management in ELBW infants changed significantly between 1997 and 2011 and largely reflect current recommendations.
Resumo:
Microvascular surgery has become an important method for reconstructing surgical defects due to trauma, tumors or after burn. The most important factor for successful free flap transfer is a well-executed anastomosis. The time needed to perform the anastomosis and the failure rate are not negligible despite the high level of operator's experience. During the history, many alternatives were tried to help the microsurgeon and to reduce the complications. A Medline literature search was performed to find articles dealing with non-suture methods of microvascular anastomosis. Many historical books were also included. The non-suture techniques can be divided into four groups based on the used mechanism of sutures: double intubation including tubes and stents, intubation-eversion including simple rings, double eversion including staples and double rings, and wall adjustement with adhesives or laser. All these techniques were able to produce a faster and easier microvascular anastomosis. Nevertheless, disadvantages of the suturless techniques include toxicity, high cost, leakage or aneurysm formation. More refinement is needed before their widespread adoption. Thus, laser-assisted microvascular anastomosis using 1,9 μm diode laser appeared to be a safe and reliable help for the microsurgeon and may be further developed in the near future.
Resumo:
A goat was scheduled for experimental surgery under general anesthesia. The first attempt of performing endotracheal intubation failed and provoked laryngeal spasm. After repeated succesful intubation of inhalation anesthesia was delivered in high concentrations of sevoflurane. Suddenly hypertension and tachycardia were observed, followed by foamy airway secretion and then severe airway hemorrhage. The authors hypothesize that laryngeal spasm provoked respiratory distress and pulmonary edema. The delivered high concentrations of sevoflurane probably enhanced a hyperadrenergic response, predisposing to the development of airway hemorrhage.