6 resultados para Interfacial adhesions
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Adhesions occur with a high incidence after intra-abdominal surgery but can also develop due to infections, radiation or for idiopathic reasons. The formation of adhesions is initiated by tissue damage and is the result of peritoneal tissue repair involving the activation of the inflammatory system and the coagulation cascade. Acute small bowel obstruction is one of the most common complications and should be diagnosed rapidly using clinical examination and radiological imaging. A complete obstruction is life threatening and in a high percentage of patients requires rapid surgical intervention by laparotomy or laparoscopy depending on the clinical situation and the patients history. Despite numerous investigations, there is no reliable, commonly used method to prevent intra-abdominal adhesions. Minimizing tissue damage and foreign body exposure, avoiding spillage of intestinal and biliary contents as well as a laparoscopic approach seem to have a beneficial effect on the formation of intra-abdominal adhesions.
Resumo:
The functional capacity of osseointegrated dental implants to bear load is largely dependent on the quality of the interface between the bone and implant. Sandblasted and acid-etched (SLA) surfaces have been previously shown to enhance bone apposition. In this study, the SLA has been compared with a chemically modified SLA (modSLA) surface. The increased wettability of the modSLA surface in a protein solution was verified by dynamic contact angle analysis. Using a well-established animal model with a split-mouth experimental design, implant removal torque testing was performed to determine the biomechanical properties of the bone-implant interface. All implants had an identical cylindrical shape with a standard thread configuration. Removal torque testing was performed after 2, 4, and 8 weeks of bone healing (n = 9 animals per healing period, three implants per surface type per animal) to evaluate the interfacial shear strength of each surface type. Results showed that the modSLA surface was more effective in enhancing the interfacial shear strength of implants in comparison with the conventional SLA surface during early stages of bone healing. Removal torque values of the modSLA-surfaced implants were 8-21% higher than those of the SLA implants (p = 0.003). The mean removal torque values for the modSLA implants were 1.485 N m at 2 weeks, 1.709 N m at 4 weeks, and 1.345 N m at 8 weeks; and correspondingly, 1.231 N m, 1.585 N m, and 1.143 N m for the SLA implants. The bone-implant interfacial stiffness calculated from the torque-rotation curve was on average 9-14% higher for the modSLA implants when compared with the SLA implants (p = 0.038). It can be concluded that the modSLA surface achieves a better bone anchorage during early stages of bone healing than the SLA surface; chemical modification of the standard SLA surface likely enhances bone apposition and this has a beneficial effect on the interfacial shear strength.
Resumo:
Femoroacetabular impingement (FAI) is an established cause of osteoarthrosis of the hip. Surgery is intended to remove the cause of impingement with hip dislocation and resection of osseous prominences of the acetabular rim and of the femoral head-neck junction. Using the Merle d'Aubigné score and qualitative categories, recent studies suggest good to excellent outcomes in 75% to 80% of patients after open surgery with dislocation of the femoral head. Unsatisfactory outcome is mainly related to pain, located either in the area of the greater trochanter or in the groin. There are several reasons for persisting groin pain. Joint degeneration with joint space narrowing and/or osteophyte formation, insufficient correction of the acetabula, and femoral pathology are known factors for unsatisfactory outcome. Recently, intraarticular adhesions between the femoral neck and joint capsule have been identified as an additional cause of postoperative groin pain. The adhesions form between the joint capsule and the resected area on the femoral neck and may lead to soft tissue impingement. MR-arthrography is used for diagnosis and the adhesions can be treated successfully by arthroscopy. While arthroscopic resection improves outcome it is technically demanding. Avoiding the formation of adhesions is important and is perhaps best accomplished by passive motion exercises after the initial surgery.