51 resultados para Injection molding of plastics
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Hybrid molds enable the fabrication of polymeric parts with features of different length scales by injection molding. The resulting polymer microelements combine optical or biological functionalities with designed mechanical properties. Two applications are chosen for illustration of this concept: As a first example, microelements for optical communication via fiber-to-fiber coupling are manufactured by combining two molds to a small mold insert. Both molds are fabricated using lithography and electroplating. As a second example, microcantilevers (μCs) for chemical sensing are surface patterned using a modular mold composed of a laser-machined cavity defining the geometry of the μCs, and an opposite flat tool side which is covered by a patterned polymer foil. Injection molding results in an array of 35 μm-thick μCs with microscale surface topographies. In both cases, when the mold is assembled and closed, reliefs are transferred onto one surface of the molded element whose outlines are defined by the micromold cavity. The main advantage of these hybrid methods lies in the simple integration of optical surface structures and gratings onto the surface of microcomponents with different sizes and orientations. This allows for independent development of functional properties and combinations thereof.
Resumo:
The effect of varying injection rates of a saline chaser on aortic enhancement in computed tomography (CT) angiography was determined. Single-level, dynamic CT images of a physiological flow phantom were acquired between 0 and 50 s after initiation of contrast medium injection. Four injection protocols were applied with identical contrast medium administration (150 ml injected at 5 ml/s). For baseline protocol A, no saline chaser was applied. For protocols B, C, and D, 50 ml of saline was injected at 2.5 ml/s, 5 ml/s, and 10 ml/s, respectively. Injecting the saline chaser at twice the rate as the contrast medium yielded significantly higher peak aortic enhancement values than injecting the saline at half or at the same rate as the contrast medium (P < 0.05). Average peak aortic enhancement (HU) measured 214, 214, 218, and 226 for protocols A, B, C, and D, respectively. The slower the saline-chaser injection rate, the longer the duration of 90% peak enhancement: 13.6, 12.2, and 11.7 s for protocols B, C, and D, respectively (P > 0.05). In CT angiography, saline chaser injected at twice the rate as the contrast medium leads to increased peak aortic enhancement and saline chaser injected at half the rate tends towards prolonging peak aortic enhancement plateau.
Resumo:
STUDY DESIGN: In vitro testing of vertebroplasty techniques including pulsed jet-lavage for fat and marrow removal in human cadaveric lumbar and thoracic vertebrae. OBJECTIVE: To develop jet-lavage techniques for vertebroplasty and investigate their effect on cement distribution, injection forces, and fat embolism. SUMMARY OF BACKGROUND DATA: The main complications of cement vertebroplasty are cement leakage and pulmonary fat embolism, which can have fatal consequences and are difficult to prevent reliably by current vertebroplasty techniques. METHODS: Twenty-four vertebrae (Th8-L04) from 5 osteoporotic cadaver spines were grouped in triplets depending on bone mineral density (BMD). Before polymethylmethacrylate (PMMA) vertebroplasty, a pulsatile jet-lavage for removal of intertrabecular fat and bone marrow was performed in 2 groups with 8 specimens each, performing radial and axial irrigation from the biopsy needles. One hundred mL of Ringer solution were injected through 1 pedicle and regained by low vacuum via the contralateral pedicle. Eight control vertebrae were not irrigated. All specimens underwent standardized PMMA cement augmentation injecting 20% of the vertebral volume. Injection forces, cement distribution, and extravasations were quantified. RESULTS: All irrigation solution could be retrieved with the vacuum applied. A Kruskal-Wallis test revealed significantly higher injection forces of the control group as compared with the irrigated groups (P = 0.021). Dilatation of the syringe at forces above 300 N occurred in 75% of the untreated compared with 12.5% of the lavaged specimens. CT distribution analysis showed more homogenous cement distribution of the cement and significantly less extravasation in the irrigated specimens. CONCLUSION: The developed lavage technique for vertebroplasty showed to be feasible and reproducible. The reduction of injection forces would allow the use of more viscous PMMA cement lowering the risk for cement embolization and results in a safer procedure. The wash-out of bone marrow and the possible reduction of pulmonary fat embolism have to be verified with in vivo models.
Resumo:
Percutaneous vertebroplasty, comprising of the injection of polymethylmethacrylate (PMMA) into vertebral bodies, is an efficient procedure to stabilize osteoporotic compression fractures as well as other weakening lesions. Besides fat embolism, cement leakage is considered to be one of the major and most severe complications during percutaneous vertebroplasty. The viscosity of the PMMA during injection plays a key role in this context. It was shown in vitro that the best way to lower the risk of cement leakage is to inject the cement at higher viscosity, which is requires high injection forces. Injection forces can be reduced by applying a newly developed lavage technique as it was shown in vitro using human cadaver vertebrae. The purpose of this study was to prove the in vitro results in an in vivo model. The investigation was incorporated in an animal study that was performed to evaluate the cardiovascular reaction on cement augmentation using the lavage technique. Injection forces were measured with instrumentation for 1 cc syringes, additionally acquiring plunger displacement. Averaged injection forces measured, ranged from 12 to 130 N and from 28 to 140 N for the lavage group and the control group, respectively. Normalized injection forces (by viscosity and injection speed) showed a trend to be lower for the lavage group in comparison to the control group (P = 0.073). In conclusion, the clinical relevance on the investigated lavage technique concerning lowering injection forces was only shown by trend in the performed animal study. However, it might well be that the effect is more pronounced for osteoporotic vertebral bodies.
Resumo:
Using variothermal polymer micro-injection molding, disposable arrays of eight polymer micro-cantilevers each 500 μm long, 100 μm wide and 25 μm thick were fabricated. The present study took advantage of an easy flow grade polypropylene. After gold coating for optical read-out and asymmetrical sensitization, the arrays were introduced into the Cantisens(®) Research system to perform mechanical and functional testing. We demonstrate that polypropylene cantilevers can be used as biosensors for medical purposes in the same manner as the established silicon ones to detect single-stranded DNA sequences and metal ions in real-time. A differential signal of 7 nm was detected for the hybridization of 1 μM complementary DNA sequences. For 100 nM copper ions the differential signal was found to be (36 ± 5) nm. Nano-mechanical sensing of medically relevant, nanometer-size species is essential for fast and efficient diagnosis.
Resumo:
A major goal in antibody design for cancer therapy is to tailor the pharmacokinetic properties of the molecule according to specific treatment requirements. Key parameters determining the pharmacokinetics of therapeutic antibodies are target specificity, affinity, stability, and size. Using the p185HER-2 (HER-2)-specific scFv 4D5 as model system, we analyzed how changes in molecular weight and valency independently affect antigen binding and tumor localization. By employing multimerization and PEGylation, four different antibody formats were generated and compared with the scFv 4D5. First, dimeric and tetrameric miniantibodies were constructed by fusion of self-associating, disulfide-linked peptides to the scFv 4D5. Second, we attached a 20-kDa PEG moiety to the monovalent scFv and to the divalent miniantibody at the respective C terminus. In all formats, serum stability and full binding reactivity of the scFv 4D5 were retained. Functional affinity, however, did change. An avidity increase was achieved by multimerization, whereas PEGylation resulted in a 5-fold decreased affinity. Nevertheless, the PEGylated monomer showed an 8.5-fold, and the PEGylated dimer even a 14.5-fold higher tumor accumulation than the corresponding scFv, 48 h post-injection, because of a significantly longer serum half-life. In comparison, the non-PEGylated bivalent and tetravalent miniantibodies showed only a moderate increase in tumor localization compared with the scFv, which correlated with the degree of multimerization. However, these non-PEGylated formats resulted in higher tumor-to-blood ratios. Both multimerization and PEGylation represent thus useful strategies to tailor the pharmacokinetic properties of therapeutic antibodies and their combined use can additively improve tumor targeting.
Resumo:
PURPOSE: We documented the effects of intradetrusor injections of botulinum neurotoxin type A (Botox(R)) for refractory idiopathic detrusor overactivity so that prospective patients maybe properly informed about possible improvement in quality of life, the duration of interinjection intervals and the risk of clean intermittent self-catheterization. MATERIALS AND METHODS: A total of 81 consecutive patients with refractory idiopathic detrusor overactivity treated with intradetrusor injections of 200 U botulinum neurotoxin type A at 20 sites per injection course were evaluated in this prospective, nonrandomized, open label cohort study. The primary outcome was changes in quality of life, as assessed by the short form of the Urogenital Distress Inventory and the Incontinence Impact Questionnaire before and after treatment. Secondary outcomes were the interinjection interval and the need for clean intermittent self-catheterization. RESULTS: After intradetrusor botulinum neurotoxin type A injections there was significant improvement in quality of life, which was sustained after repeat injections. Mean Urogenital Distress Inventory and Incontinence Impact Questionnaire scores decreased from 56 to 26 and 59 to 21 after injection 1 in 81 patients, from 52 to 30 and 51 to 24 after injection 2 in 24, from 40 to 19 and 43 to 17 after injection 3 in 13, from 44 to 17 and 61 to 15 after injection 4 in 6 and from 51 to 17 and 63 to 14 after injection 5 in 4, respectively. The median interinjection interval was 15, 12, 14 and 13 months between injections 1 and 2, 2 and 3, 3 and 4, and 4 and 5, respectively. Considering a post-void residual urine of greater than 100 ml with lower urinary tract symptoms as the indication for clean intermittent self-catheterization, the overall clean intermittent self-catheterization rate after treatment was 43%. CONCLUSIONS: Intradetrusor botulinum neurotoxin type A injections for refractory idiopathic detrusor overactivity significantly improved quality of life. This effect was sustained after repeat injection. More than 2 of 5 patients with refractory idiopathic detrusor overactivity required clean intermittent self-catheterization after botulinum neurotoxin type A injections and all prospective patients should be informed about this.
Resumo:
Peripheral neuropathic pain is a disabling condition resulting from nerve injury. It is characterized by the dysregulation of voltage-gated sodium channels (Navs) expressed in dorsal root ganglion (DRG) sensory neurons. The mechanisms underlying the altered expression of Na(v)s remain unknown. This study investigated the role of the E3 ubiquitin ligase NEDD4-2, which is known to ubiquitylate Navs, in the pathogenesis of neuropathic pain in mice. The spared nerve injury (SNI) model of traumatic nerve injury-induced neuropathic pain was used, and an Na(v)1.7-specific inhibitor, ProTxII, allowed the isolation of Na(v)1.7-mediated currents. SNI decreased NEDD4-2 expression in DRG cells and increased the amplitude of Na(v)1.7 and Na(v)1.8 currents. The redistribution of Na(v)1.7 channels toward peripheral axons was also observed. Similar changes were observed in the nociceptive DRG neurons of Nedd4L knockout mice (SNS-Nedd4L(-/-)). SNS-Nedd4L(-/-) mice exhibited thermal hypersensitivity and an enhanced second pain phase after formalin injection. Restoration of NEDD4-2 expression in DRG neurons using recombinant adenoassociated virus (rAAV2/6) not only reduced Na(v)1.7 and Na(v)1.8 current amplitudes, but also alleviated SNI-induced mechanical allodynia. These findings demonstrate that NEDD4-2 is a potent posttranslational regulator of Na(v)s and that downregulation of NEDD4-2 leads to the hyperexcitability of DRG neurons and contributes to the genesis of pathological pain.
Resumo:
Polymer implants are interesting alternatives to the contemporary load-bearing implants made from metals. Polyetheretherketone (PEEK), a well-established biomaterial for example, is not only iso-elastic to bone but also permits investigating the surrounding soft tissues using magnetic resonance imaging or computed tomography, which is particularly important for cancer patients. The commercially available PEEK bone implants, however, require costly coatings, which restricts their usage. As an alternative to coatings, plasma activation can be applied. The present paper shows the plasma-induced preparation of nanostructures on polymer films and on injection-molded micro-cantilever arrays and the associated chemical modifications of the surface. In vitro cell experiments indicate the suitability of the activation process. In addition, we show that microstructures such as micro-grooves 1 μm deep and 20 μm wide cause cell alignment. The combination of micro-injection molding, simultaneous microstructuring using inserts/bioreplica and plasma treatments permits the preparation of polymer implants with nature-analogue, anisotropic micro- and nanostructures.
Resumo:
BACKGROUND Painful cutaneous injection site reactions may hamper treatment with interferon β (IFN-β) and glatiramer acetate (GA) in multiple sclerosis (MS) patients. OBJECTIVE To maintain therapy adherence, efficient therapeutic modalities for these subcutaneous inflammatory lesions are urgently needed. We tested the application of local extracorporeal shock wave therapy (ESWT). METHODS We applied 5 sessions of ESWT to 8 patients suffering from MS who had developed painful panniculitis at the injection sites of either IFN-β or GA. Clinical outcomes, i.e. pain reduction and regression of induration, were assessed 3 and 6 months after completion of the ESWT using a visual analogue score. RESULTS All patients showed both significant pain reduction and reduction of the skin induration in the treated lesions, while in untreated control lesions there was no improvement. CONCLUSION ESWT proved to be a non-invasive, safe and efficient physical treatment modality for injection-induced painful cutaneous side effects of disease-modifying drugs in MS. © 2014 S. Karger AG, Basel.
Resumo:
Pollen-trap results from the Swiss Alps 1996–2009 were used to assess the pollen dispersal–deposition properties of Poaceae (grasses) and Cyperaceae (sedges). Dispersal parameter values were investigated for a modified version of the Prentice–Sugita pollen dispersal–deposition model. Appropriate values (i.e. realistic in the field and allowing realistic modelling results) for wind speed are suggested to be in the range of 3–7 m s− 1 and for pollen an injection height of 0.03–0.1 m above the ground. The appropriate range of pollen injection height values for grasses and sedges differs from that of trees in the same area, suggesting different pollen dispersal properties between herbs and trees. In addition, logarithmic weighting of the vegetation was tested as an alternative to the modified Prentice–Sugita model. This yielded very similar results, suggesting that the use of such much simpler approximations of the pollen–vegetation relationship is a plausible alternative. Based on the modified Prentice–Sugita model, absolute pollen productivity for Poaceae was estimated to 7300 ± 400 grains cm− 2 year− 1 (1 SE). The data basis for Cyperaceae is smaller than for Poaceae, but the dispersal parameter values determined as appropriate for Poaceae yield good results. Absolute pollen productivity for Cyperaceae was estimated to 6300 ± 1100 grains cm− 2 year− 1 (1 SE).
Resumo:
PURPOSE Leakage is the most common complication of percutaneous cement augmentation of the spine. The viscosity of the polymethylmethacrylate (PMMA) cement is strongly correlated with the likelihood of cement leakage. We hypothesized that cement leakage can be reduced by sequential cement injection in a vertebroplasty model. METHODS A standardized vertebral body substitute model, consisting of aluminum oxide foams coated by acrylic cement with a preformed leakage path, simulating a ventral vein, was developed. Three injection techniques of 6 ml PMMA were assessed: injection in one single step (all-in-one), injection of 1 ml at the first and 5 ml at the second step with 1 min latency in-between (two-step), and sequential injection of 0.5 ml with 1-min latency between the sequences (sequential). Standard PMMA vertebroplasty cement was used; each injection type was tested on ten vertebral body substitute models with two possible leakage paths per model. Leakage was assessed by radiographs using a zonal graduation: intraspongious = no leakage and extracortical = leakage. RESULTS The leakage rate was significantly lower in the "sequential" technique (2/20 leakages) followed by "two-step" (15/20) and "all-in-one" (20/20) techniques (p < 0.001). The RR for a cement leakage was 10.0 times higher in the "all-in-one" compared to the "sequential" group (95 % confidence intervals 2.7-37.2; p < 0.001). CONCLUSIONS The sequential cement injection is a simple approach to minimize the risk for leakage. Taking advantage of the temperature gradient between body and room temperature, it is possible to increase the cement viscosity inside the vertebra while keeping it low in the syringe. Using sequential injection of small cement volumes, further leakage paths are blocked before further injection of the low-viscosity cement.
Resumo:
Cranioplasty is a common neurosurgical procedure. Free-hand molding of polymethyl methacrylate (PMMA) cement into complex three-dimensional shapes is often time-consuming and may result in disappointing cosmetic outcomes. Computer-assisted patient-specific implants address these disadvantages but are associated with long production times and high costs. In this study, we evaluated the clinical, radiological, and cosmetic outcomes of a time-saving and inexpensive intraoperative method to mold custom-made implants for immediate single-stage or delayed cranioplasty. Data were collected from patients in whom cranioplasty became necessary after removal of bone flaps affected by intracranial infection, tumor invasion, or trauma. A PMMA replica was cast between a negative form of the patient's own bone flap and the original bone flap with exactly the same shape, thickness, and dimensions. Clinical and radiological follow-up was performed 2 months post-surgery. Patient satisfaction (Odom criteria) and cosmesis (visual analogue scale for cosmesis) were evaluated 1 to 3 years after cranioplasty. Twenty-seven patients underwent intraoperative template-molded patient-specific cranioplasty with PMMA. The indications for cranioplasty included bone flap infection (56%, n = 15), calvarian tumor resection (37%, n = 10), and defect after trauma (7%, n = 2). The mean duration of the molding procedure was 19 ± 7 min. Excellent radiological implant alignment was achieved in 94% of the cases. All (n = 23) but one patient rated the cosmetic outcome (mean 1.4 years after cranioplasty) as excellent (70%, n = 16) or good (26%, n = 6). Intraoperative cast-molded reconstructive cranioplasty is a feasible, accurate, fast, and cost-efficient technique that results in excellent cosmetic outcomes, even with large and complex skull defects.
Resumo:
BACKGROUND: Anecortave acetate is an angiostatic cortisene which is injected as a posterior juxtascleral depot and has been shown to be effective in the treatment of exudative age-related macular degeneration (AMD). The compound is not yet approved in Switzerland but can be used as "compassionate use" in individual cases. PATIENTS AND METHODS: An uncontrolled case series with standardised documentation of ETDRS visual acuity, near acuity, need for magnification and fluorescein angiography was performed. RESULTS: 22 eyes of 19 patients (8 male, 11 female, average age 78.8 years) were treated with a posterior juxtascleral depot injection (PJD) of 15 mg anecortave acetate. The mean change in visual acuity after 3 months in eyes treated with anecortave acetate was -2.6 ETDRS letters corresponding to 0.52 Snellen lines. 3/20 eyes gained more than 1 line. 11/20 eyes showed stable visual acuity (+/- 1 Snellen line, +/- 5 ETDRS letters). 5/20 eyes developed moderate vision loss (one to two Snellen lines, 6-10 ETDRS letters). 1/20 lost 18 ETDRS letters (> 3 Snellen lines). There were no moderate or severe adverse events. CONCLUSIONS: A PJD of 15 mg anecortave acetate is safe and well tolerated. In eyes with occult CNV without recent progression or with residual neovascular activity after photodynamic therapy anecortave acetate may be an alternative therapeutic option before considering intravitreal anti-VEGF agents due to the much less invasive character and lower risk profile.
Resumo:
Intraoperative molding of polymethyl-methacrylate into complex three-dimensional shapes with correct thickness is often a time-consuming process and may lead to unsatisfying cosmetical results. This article describes an intraoperative technique to assemble a polymethyl-methacrylate implant as a replica of the patient's bone flap. This approach provides a fast and inexpensive alternative technique with good cosmetic outcome. The technique is feasible and can be applied in early and delayed cranioplasty procedures. In selected patients, immediate single-stage reconstruction avoids a second operation.