8 resultados para Index Testing

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

40.00% 40.00%

Publicador:

Resumo:

A low simplified Pulmonary Embolism Severity Index (sPESI), defined as age ≤80 years and absence of systemic hypotension, tachycardia, hypoxia, cancer, heart failure, and lung disease, identifies low-risk patients with acute pulmonary embolism (PE). It is unknown whether cardiac troponin testing improves the prediction of clinical outcomes if the sPESI is not low. In the prospective Swiss Venous Thromboembolism Registry, 369 patients with acute PE and a troponin test (conventional troponin T or I, highly sensitive troponin T) were enrolled from 18 hospitals. A positive test result was defined as a troponin level above the manufacturers assay threshold. Among the 106 (29%) patients with low sPESI, the rate of mortality or PE recurrence at 30 days was 1.0%. Among the 263 (71%) patients with high sPESI, 177 (67%) were troponin-negative and 86 (33%) troponin-positive; the rate of mortality or PE recurrence at 30 days was 4.6% vs. 12.8% (p=0.015), respectively. Overall, risk assessment with a troponin test (hazard ratio [HR] 3.39, 95% confidence interval [CI] 1.38-8.37; p=0.008) maintained its prognostic value for mortality or PE recurrence when adjusted for sPESI (HR 5.80, 95%CI 0.76-44.10; p=0.09). The combination of sPESI with a troponin test resulted in a greater area under the receiver-operating characteristic curve (HR 0.72, 95% CI 0.63-0.81) than sPESI alone (HR 0.63, 95% CI 0.57-0.68) (p=0.023). In conclusion, although cardiac troponin testing may not be required in patients with a low sPESI, it adds prognostic value for early death and recurrence for patients with a high sPESI.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Primary care is an important provider of sexual health care in England. We sought to explore the extent of testing for chlamydia and HIV in general practice and its relation to associated measures of sexual health in two contrasting geographical settings. Methods We analysed chlamydia and HIV testing data from 64 general practices and one genitourinary medicine (GUM) clinic in Brent (from mid-2003 to mid-2006) and 143 general practices and two GUM clinics in Avon (2004). We examined associations between practice testing status, practice characteristics and hypothesised markers of population need (area level teenage conception rates and Index of Multiple Deprivation, IMD scores). Results No HIV or chlamydia testing was done in 19% (12/64) of general practices in Brent, compared to 2.1% (3/143) in Avon. In Brent, the mean age of general practitioners (GPs) in Brent practices that tested for chlamydia or HIV was lower than in those that had not conducted testing. Practices where no HIV testing was done had slightly higher local teenage conception rates (median 23.5 vs. 17.4/1000 women aged 15-44, p = 0.07) and served more deprived areas (median IMD score 27.1 vs. 21.8, p = 0.05). Mean yearly chlamydia and HIV testing rates, in practices that did test were 33.2 and 0.6 (per 1000 patients aged 15-44 years) in Brent, and 34.1 and 10.3 in Avon, respectively. In Brent practices only 20% of chlamydia tests were conducted in patients aged under 25 years, compared with 39% in Avon. Conclusions There are substantial geographical differences in the intensity of chlamydia and HIV testing in general practice. Interventions to facilitate sexually transmitted infection and HIV testing in general practice are needed to improve access to effective sexual health care. The use of routinely-collected laboratory, practice-level and demographic data for monitoring sexual health service provision and informing service planning should be more widely evaluated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Existing lower-limb, region-specific, patient-reported outcome measures have clinimetric limitations, including limitations in psychometric characteristics (eg, lack of internal consistency, lack of responsiveness, measurement error) and the lack of reported practical and general characteristics. A new patient-reported outcome measure, the Lower Limb Functional Index (LLFI), was developed to address these limitations. Objective The purpose of this study was to overcome recognized deficiencies in existing lower-limb, region-specific, patient-reported outcome measures through: (1) development of a new lower-extremity outcome scale (ie, the LLFI) and (2) evaluation of the clinimetric properties of the LLFI using the Lower Extremity Functional Scale (LEFS) as a criterion measure. Design This was a prospective observational study. Methods The LLFI was developed in a 3-stage process of: (1) item generation, (2) item reduction with an expert panel, and (3) pilot field testing (n=18) for reliability, responsiveness, and sample size requirements for a larger study. The main study used a convenience sample (n=127) from 10 physical therapy clinics. Participants completed the LLFI and LEFS every 2 weeks for 6 weeks and then every 4 weeks until discharge. Data were used to assess the psychometric, practical, and general characteristics of the LLFI and the LEFS. The characteristics also were evaluated for overall performance using the Measurement of Outcome Measures and Bot clinimetric assessment scales. Results The LLFI and LEFS demonstrated a single-factor structure, comparable reliability (intraclass correlation coefficient [2,1]=.97), scale width, and high criterion validity (Pearson r=.88, with 95% confidence interval [CI]). Clinimetric performance was higher for the LLFI compared with the LEFS on the Measurement of Outcome Measures scale (96% and 95%, respectively) and the Bot scale (100% and 83%, respectively). The LLFI, compared with the LEFS, had improved responsiveness (standardized response mean=1.75 and 1.64, respectively), minimal detectable change with 90% CI (6.6% and 8.1%, respectively), and internal consistency (α=.91 and .95, respectively), as well as readability with reduced user error and completion and scoring times. Limitations Limitations of the study were that only participants recruited from outpatient physical therapy clinics were included and that no specific conditions or diagnostic subgroups were investigated. Conclusion The LLFI demonstrated sound clinimetric properties. There was lower response error, efficient completion and scoring, and improved responsiveness and overall performance compared with the LEFS. The LLFI is suitable for assessment of lower-limb function.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PRINCIPLES: Coeliac disease (gluten sensitive enteropathy) is a genetically determined disorder with an incidence in the general population that is comparable to type 2 diabetes mellitus. Awareness of this fact and of the often atypical and oligosymptomatic manifestations is only now gaining ground in the medical profession. A high index of suspicion is important in order to minimise diagnostic and therapeutic delay. METHODS: Testing patterns and follow-up for coeliac disease in our institution have been analysed retrospectively for the past five years. The current literature was reviewed with respect to recommendations for clinical practice. RESULTS: A total of 271 patients were tested for coeliac disease over a period of five years. Only in 24 patients were positive results found; after further work-up, the final number of cases with certain or presumed coeliac disease was four. Followup was often difficult, many patients being lost after a single visit. CONCLUSIONS: This study showed that the number of tests ordered in our institution, more often for abdominal than atypical symptoms, has started to increase in the past two years. It also showed that screening tests have found their place in general clinical practice, while the final choice of tests needs to be determined in accordance with available guidelines and local resources. Upper endoscopy with small bowel biopsy remains the gold standard for diagnosis, but its place in follow-up is less certain. Coeliac disease is a disorder for which there is a definite treatment (gluten free diet); if it is left untreated diminished quality of life and potentially serious complications may ensue. Further education of the medical profession regarding coeliac disease, its incidence, presentation and treatment, is clearly indicated..

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The GLAaS algorithm for pretreatment intensity modulation radiation therapy absolute dose verification based on the use of amorphous silicon detectors, as described in Nicolini et al. [G. Nicolini, A. Fogliata, E. Vanetti, A. Clivio, and L. Cozzi, Med. Phys. 33, 2839-2851 (2006)], was tested under a variety of experimental conditions to investigate its robustness, the possibility of using it in different clinics and its performance. GLAaS was therefore tested on a low-energy Varian Clinac (6 MV) equipped with an amorphous silicon Portal Vision PV-aS500 with electronic readout IAS2 and on a high-energy Clinac (6 and 15 MV) equipped with a PV-aS1000 and IAS3 electronics. Tests were performed for three calibration conditions: A: adding buildup on the top of the cassette such that SDD-SSD = d(max) and comparing measurements with corresponding doses computed at d(max), B: without adding any buildup on the top of the cassette and considering only the intrinsic water-equivalent thickness of the electronic portal imaging devices device (0.8 cm), and C: without adding any buildup on the top of the cassette but comparing measurements against doses computed at d(max). This procedure is similar to that usually applied when in vivo dosimetry is performed with solid state diodes without sufficient buildup material. Quantitatively, the gamma index (gamma), as described by Low et al. [D. A. Low, W. B. Harms, S. Mutic, and J. A. Purdy, Med. Phys. 25, 656-660 (1998)], was assessed. The gamma index was computed for a distance to agreement (DTA) of 3 mm. The dose difference deltaD was considered as 2%, 3%, and 4%. As a measure of the quality of results, the fraction of field area with gamma larger than 1 (%FA) was scored. Results over a set of 50 test samples (including fields from head and neck, breast, prostate, anal canal, and brain cases) and from the long-term routine usage, demonstrated the robustness and stability of GLAaS. In general, the mean values of %FA remain below 3% for deltaD equal or larger than 3%, while they are slightly larger for deltaD = 2% with %FA in the range from 3% to 8%. Since its introduction in routine practice, 1453 fields have been verified with GLAaS at the authors' institute (6 MV beam). Using a DTA of 3 mm and a deltaD of 4% the authors obtained %FA = 0.9 +/- 1.1 for the entire data set while, stratifying according to the dose calculation algorithm, they observed: %FA = 0.7 +/- 0.9 for fields computed with the analytical anisotropic algorithm and %FA = 2.4 +/- 1.3 for pencil-beam based fields with a statistically significant difference between the two groups. If data are stratified according to field splitting, they observed %FA = 0.8 +/- 1.0 for split fields and 1.0 +/- 1.2 for nonsplit fields without any significant difference.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: To assess health care utilisation for patients co-infected with TB and HIV (TB-HIV), and to develop a weighted health care index (HCI) score based on commonly used interventions and compare it with patient outcome. METHODS: A total of 1061 HIV patients diagnosed with TB in four regions, Central/Northern, Southern and Eastern Europe and Argentina, between January 2004 and December 2006 were enrolled in the TB-HIV study. A weighted HCI score (range 0–5), based on independent prognostic factors identified in multivariable Cox models and the final score, included performance of TB drug susceptibility testing (DST), an initial TB regimen containing a rifamycin, isoniazid and pyrazinamide, and start of combination antiretroviral treatment (cART). RESULTS: The mean HCI score was highest in Central/Northern Europe (3.2, 95%CI 3.1–3.3) and lowest in Eastern Europe (1.6, 95%CI 1.5–1.7). The cumulative probability of death 1 year after TB diagnosis decreased from 39% (95%CI 31–48) among patients with an HCI score of 0, to 9% (95%CI 6–13) among those with a score of ≥4. In an adjusted Cox model, a 1-unit increase in the HCI score was associated with 27% reduced mortality (relative hazard 0.73, 95%CI 0.64–0.84). CONCLUSIONS: Our results suggest that DST, standard anti-tuberculosis treatment and early cART may improve outcome for TB-HIV patients. The proposed HCI score provides a tool for future research and monitoring of the management of TB-HIV patients. The highest HCI score may serve as a benchmark to assess TB-HIV management, encouraging continuous health care improvement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of biomarkers to infer drug response in patients is being actively pursued, yet significant challenges with this approach, including the complicated interconnection of pathways, have limited its application. Direct empirical testing of tumor sensitivity would arguably provide a more reliable predictive value, although it has garnered little attention largely due to the technical difficulties associated with this approach. We hypothesize that the application of recently developed microtechnologies, coupled to more complex 3-dimensional cell cultures, could provide a model to address some of these issues. As a proof of concept, we developed a microfluidic device where spheroids of the serous epithelial ovarian cancer cell line TOV112D are entrapped and assayed for their chemoresponse to carboplatin and paclitaxel, two therapeutic agents routinely used for the treatment of ovarian cancer. In order to index the chemoresponse, we analyzed the spatiotemporal evolution of the mortality fraction, as judged by vital dyes and confocal microscopy, within spheroids subjected to different drug concentrations and treatment durations inside the microfluidic device. To reflect microenvironment effects, we tested the effect of exogenous extracellular matrix and serum supplementation during spheroid formation on their chemotherapeutic response. Spheroids displayed augmented chemoresistance in comparison to monolayer culturing. This resistance was further increased by the simultaneous presence of both extracellular matrix and high serum concentration during spheroid formation. Following exposure to chemotherapeutics, cell death profiles were not uniform throughout the spheroid. The highest cell death fraction was found at the center of the spheroid and the lowest at the periphery. Collectively, the results demonstrate the validity of the approach, and provide the basis for further investigation of chemotherapeutic responses in ovarian cancer using microfluidics technology. In the future, such microdevices could provide the framework to assay drug sensitivity in a timeframe suitable for clinical decision making.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

ntroduction: The ProAct study has shown that a pump switch to the Accu-Chek® Combo system (Roche Diagnostics Deutschland GmbH, Mannheim, Germany) in type 1 diabetes patients results in stable glycemic control with significant improvements in glycated hemoglobin (HbA1c) in patients with unsatisfactory baseline HbA1c and shorter pump usage time. Patients and Methods: In this post hoc analysis of the ProAct database, we investigated the glycemic control and glycemic variability at baseline by determination of several established parameters and scores (HbA1c, hypoglycemia frequency, J-score, Hypoglycemia and Hyperglycemia Indexes, and Index of Glycemic Control) in participants with different daily bolus and blood glucose measurement frequencies (less than four day, four or five per day, and more than five per day, in both cases). The data were derived from up to 299 patients (172 females, 127 males; age [mean±SD], 39.4±15.2 years; pump treatment duration, 7.0±5.2 years). Results: Participants with frequent glucose readings had better glycemic control than those with few readings (more than five readings per day vs. less than four readings per day: HbA1c, 7.2±1.1% vs. 8.0±0.9%; mean daily blood glucose, 151±22 mg/dL vs. 176±30 mg/dL; percentage of readings per month >300 mg/dL, 10±4% vs. 14±5%; percentage of readings in target range [80-180 mg/dL], 59% vs. 48% [P<0.05 in all cases]) and had a lower glycemic variability (J-score, 49±13 vs. 71±25 [P<0.05]; Hyperglycemia Index, 0.9±0.5 vs. 1.9±1.2 [P<0.05]; Index of Glycemic Control, 1.9±0.8 vs. 3.1±1.6 [P<0.05]; Hypoglycemia Index, 0.9±0.8 vs. 1.2±1.3 [not significant]). Frequent self-monitoring of blood glucose was associated with a higher number of bolus applications (6.1±2.2 boluses/day vs. 4.5±2.0 boluses/day [P<0.05]). Therefore, a similar but less pronounced effect on glycemic variability in favor of more daily bolus applications was observed (more than five vs. less than four bolues per day: J-score, 57±17 vs. 63±25 [not significant]; Hypoglycemia Index, 1.0±1.0 vs. 1.5±1.4 [P<0.05]; Hyperglycemia Index, 1.3±0.6 vs. 1.6±1.1 [not significant]; Index of Glycemic Control, 2.3±1.1 vs. 3.1±1.7 [P<0.05]). Conclusions: Pump users who perform frequent daily glucose readings have a better glycemic control with lower glycemic variability.