7 resultados para Image-sound disjunctions

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE To analyze speech reading through Internet video calls by profoundly hearing-impaired individuals and cochlear implant (CI) users. METHODS Speech reading skills of 14 deaf adults and 21 CI users were assessed using the Hochmair Schulz Moser (HSM) sentence test. We presented video simulations using different video resolutions (1280 × 720, 640 × 480, 320 × 240, 160 × 120 px), frame rates (30, 20, 10, 7, 5 frames per second (fps)), speech velocities (three different speakers), webcameras (Logitech Pro9000, C600 and C500) and image/sound delays (0-500 ms). All video simulations were presented with and without sound and in two screen sizes. Additionally, scores for live Skype™ video connection and live face-to-face communication were assessed. RESULTS Higher frame rate (>7 fps), higher camera resolution (>640 × 480 px) and shorter picture/sound delay (<100 ms) were associated with increased speech perception scores. Scores were strongly dependent on the speaker but were not influenced by physical properties of the camera optics or the full screen mode. There is a significant median gain of +8.5%pts (p = 0.009) in speech perception for all 21 CI-users if visual cues are additionally shown. CI users with poor open set speech perception scores (n = 11) showed the greatest benefit under combined audio-visual presentation (median speech perception +11.8%pts, p = 0.032). CONCLUSION Webcameras have the potential to improve telecommunication of hearing-impaired individuals.

Relevância:

80.00% 80.00%

Publicador:

Relevância:

80.00% 80.00%

Publicador:

Resumo:

When on 26 May 1662 the founding first stone was laid for a new church on the island Nordstrand at the coast of Schleswig, relics of Teresa of Avila (1515-1582) and of the Dutch Carmelite abbess Maria Margaretha ab Angelis (1605-1658) were inserted. This church was built for Dutch dyke builders who were called to reconstruct the island after its destruction by flood in 1634; coming from a Catholic background and from the Dutch Republic which was at war with Spain at that time, the dyke builders and their families were guaranteed religious freedom in the Lutheran duchy of Holstein. In this paper, the reasons for the choice for the Spanish mystic Teresa of Avila and for the Dutch Carmelite abbess Maria Margaretha are discussed. The latter patroness was never beatified but had died in the smell of holiness; after her death several miracles were ascribed to her. It is understandable that migrants brought relics of their appreciated holy persons who would remind them of their homeland. The paper will first shortly introduce the two patronesses of the church. In the second part, the reasons for this choice will be discussed. Behind this translation of relics not only spiritual reasons played a role. The function of the translation of the saints was first to keep up geographical and political connections with the old country (both Spain and the Netherlands), secondly to perpetuate personal-familial relationships (esp. with Maria Margaretha), thirdly to strengthen the confessional identity in a non-Catholic environment. Fourthly the transfer brought a certain model of Christian life and reform to the new place of living, which in the second part of the 17th century became marked as “Jansenist”. The paper shows the transformation of the island into an enclave of Dutch Catholic culture.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aberrations of the acoustic wave front, caused by spatial variations of the speed-of-sound, are a main limiting factor to the diagnostic power of medical ultrasound imaging. If not accounted for, aberrations result in low resolution and increased side lobe level, over all reducing contrast in deep tissue imaging. Various techniques have been proposed for quantifying aberrations by analysing the arrival time of coherent echoes from so-called guide stars or beacons. In situations where a guide star is missing, aperture-based techniques may give ambiguous results. Moreover, they are conceptually focused on aberrators that can be approximated as a phase screen in front of the probe. We propose a novel technique, where the effect of aberration is detected in the reconstructed image as opposed to the aperture data. The varying local echo phase when changing the transmit beam steering angle directly reflects the varying arrival time of the transmit wave front. This allows sensing the angle-dependent aberration delay in a spatially resolved way, and thus aberration correction for a spatially distributed volume aberrator. In phantoms containing a cylindrical aberrator, we achieved location-independent diffraction-limited resolution as well as accurate display of echo location based on reconstructing the speed-of-sound spatially resolved. First successful volunteer results confirm the clinical potential of the proposed technique.