4 resultados para Ilium
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Radiography is part of evaluating horses with poor performance and pelvic limb lameness; however, the radiographic appearance of the sacroiliac region is poorly described. The goal of the present study was to describe the use of a simple technique to obtain radiographs of the sacroiliac region in the anesthetized horse and to describe the radiographic appearance of this region. Seventy-nine horses underwent radiography of the pelvis under general anesthesia in dorsal recumbency. During a 5s exposure time the horse was actively ventilated to blur the abdominal viscera, which allowed assessment of individual bone structures in 77 horses. A large variation in the shape of the sacral wings, their articulation with the transverse processes of L6, and the relation of the sacrum to the ilium were observed. Females had significantly narrower width of the sacral wings. Broad sacral wings and bony proliferations at the caudal aspect were commonly observed features and their size was highly correlated with gender. In males, caudal osteophytes were significantly larger than in females. Five horses had transitional or hemitransitional vertebrae. Radiography with the ventilation-induced blurring technique is a simple approach that results in diagnostic quality radiographs and delineation of the highly variable bone structures of the sacroiliac region.
Resumo:
OBJECTIVE: To report clinical features associated with iatrogenic peripheral nerve injury in dogs and cats admitted (1997-2006) to a referral teaching hospital. STUDY DESIGN: Retrospective study. ANIMALS: Dogs (n=18), 9 cats. METHODS: Patients had acute signs of monoparesis attributable to sciatic nerve dysfunction that developed after treatment. Neurologic examination and electrodiagnostic testing were performed. Surgical therapy was used for nerve entrapment and delayed reconstructive surgery used in other cases. RESULTS: Of 27 nerve injuries, 25 resulted from surgery (18 with treatment of pelvic injuries). Iliosacral luxation repair resulted in tibial (4 cats) and peroneal (3 dogs) nerve dysfunction. Other causes were intramedullary pinning of femoral fractures (3), other orthopedic surgery (cemented hip prosthesis [2] and tibial plateau-leveling osteotomy [1]), and perineal herniorrhaphy [1]. Nerve injury occurred after intramuscular injection (1 cat, 1 dog). Immediate surgical treatment was removal of intramedullary nails, extruded cement, or entrapping suture. Delayed nerve transplantation was performed in 2 dogs. Within 1 year, 13 patients recovered completely, clinical improvement occurred in 7, and there was no improvement in 7. Five of the 7 dogs that did not recover had acetabular or ilium fracture. CONCLUSION: Iatrogenic sciatic nerve injury occurred most commonly during treatment of pelvic orthopedic diseases and had a poor prognosis. Clinical variation in sciatic nerve dysfunction in dogs and cats can be explained by species anatomic differences. CLINICAL RELEVANCE: Iatrogenic sciatic nerve injury leads to severely debilitating locomotor dysfunction with an uncertain prognosis for full-functional recovery.
Resumo:
Chronic irritation of the iliopsoas tendon is a rare cause of persistent pain after total joint replacement of the hip. In the majority of cases, pain results from a mechanical conflict between the iliopsoas tendon and the anterior edge of the acetabular cup after total hip arthroplasty. Pain can be reproduced by active flexion of the hip and by active raising of the straightened leg. In addition, painful leg raising against resistance and passive hyperextension are suggestive of an irritation of the iliopsoas tendon. Symptoms evolve from a mechanical irritation of the iliopsoas tendon and an oversized or retroverted acetabular cup, screws penetrating into the inner aspect of the ilium, or from bone cement protruding beyond the anterior acetabular rim. The diagnosis may be assumed on conventional radiographs and confirmed by CT scans. Fifteen patients with psoas irritation after total hip replacement are reported on. Eleven patients were treated surgically. The acetabular cup was revised and reoriented with more anteversion in six patients, isolated screws penetrating into the tendon were cut and leveled in three patients, and prominent bone cement in conflict with the tendon was resected once. A partial release of the iliopsoas tendon only was performed in another patient. Follow-up examination (range: 11-89 months) revealed that nine patients were free of pain and two patient had mild residual complaints. Psoas irritation in combination with total hip replacement can be prevented by a correct surgical technique, especially with proper selection of the cup size and insertion of the acetabular cup avoiding a rim position exceeding the level of the anterior acetabular rim.
Resumo:
Twenty-eight feline pelves (56 hemipelves) were examined in order to identify the location for optimal sacroiliac screw placement in sacroiliac fracture-luxation repair. A drill hole was started on the median plane of the hemipelvis in the centre of the body of the first sacral segment until it penetrated the lateral cortex of the ilial wing, thus providing optimal drill hole placement. The position of the drill hole on the articular surface of the sacral wing and on the lateral surface of the ilial wing was measured. The distance of the drill hole from the cranial margin of the sacral wing was 51% of sacral wing length, just cranial to the crescent shaped hyaline cartilage. The distance from the dorsal margin was 47% of sacral wing height. The drill bit direction has to be adjusted to the cranio-caudal inclination (range 10° to 29°) and dorso-ventral inclination (range 2° to 25°) of the sacral wing. A notch in the cranial edge of the sacral wing was present, with variable position, in 34% of the specimens and is consequently not a useful landmark for sacroiliac screw placement. The drill hole on the lateral surface of the ilium was located in craniocaudal direction at a distance of 69% of sacral tuber length, measured from the cranial dorsal iliac spine. The dorso-ventral position of the drill hole was at a distance of 52% of ilial wing height measured from the sacral tuber. The ventral gluteal line, present in 93% of the cases, is a useful landmark to locate optimal screw hole position on the ilial wing.