214 resultados para INTRAVASCULAR ULTRASOUND ELASTOGRAPHY

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims: We investigated the impact of arterial injury on neointimal hyperplasia following implantation of drug-eluting stents (DES). Methods and results: A total of 196 patients with 223 segments (sirolimus-eluting stents [SES]: 104, paclitaxel-eluting stents [PES]: 119) underwent intravascular ultrasound eight months after DES implantation. Arterial injury was defined as the balloon-to-artery ratio (BAR). Segments were categorised into two groups: high BAR defined as BAR>1.1 (120 segments), and low BAR defined as BAR ≤1.1 (103 segments). Baseline clinical characteristics were similar for both groups. Although reference vessel diameter was smaller, stent diameter, maximal balloon pressure and balloon diameter were higher in the high BAR compared with the low BAR group. Lumen (7.10±1.91 vs. 6.25±1.69, p=0.001), stent (7.31±1.95 vs. 6.41±1.80, p=0.001), and external elastic membrane (17.1±4.9 vs. 14.8±4.0, p<0.0001) areas (mm2) were higher, but neointimal hyperplasia (0.21±0.36 vs. 0.16±0.48, p=0.42) area (mm2) was similar in the high BAR compared with the low BAR group. Arterial injury as assessed by BAR was not associated with the amount of neointimal hyperplasia (R2=0.003, p=0.40). Conclusions: Arterial injury does not correlate with the amount of neointimal hyperplasia following DES implantation. Conventionally aggressive DES implantation techniques do not adversely affect long-term outcome with respect to restenosis. - See more at: http://www.pcronline.com/eurointervention/30th_issue/79/#sthash.1do4X31G.dpuf

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Patients with diabetes mellitus are known to be at increased risk for acute cardiovascular events. We used intravascular ultrasound virtual histology (IVUS-VH) to examine whether nonobstructive coronary artery lesions of diabetic patients have distinct plaque composition and morphology compared with nondiabetic patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Regional differences in shear stress have been identified as reason for early plaque formation in vessel bifurcations. We aimed to investigate regional plaque morphology and composition using intravascular ultrasound (IVUS) and virtual histology (IVUS–VH) in coronary artery bifurcations. Methods We performed IVUS and IVUS–VH studies at coronary bifurcations to analyze segmental plaque burden and composition of different segments in relation to their orientation to the bifurcation. Results A total of 236 patients with a mean age of 59 ± 11 years (69% male) were analyzed. Plaque burden was higher at the contralateral vessel wall facing the bifurcation compared to the ipsilateral vessel wall and this difference was true for proximal and distal segments (proximal: 37 ± 12% and 45 ± 15% for segments at the ipsilateral and contralateral vessel wall, respectively, p < 0.001; distal: 37 ± 10% and 47 ± 15% for segments at the ipsilateral and contralateral vessel wall, respectively, p < 0.001). In addition, these segments exhibited a higher proportion of dense calcium and a lower proportion of fibrous tissue and fibro fatty tissue. Conclusions Segments on the contralateral wall of the bifurcation which have previously been identified as regions with low shear stress not only exhibited a higher plaque burden, but also a higher degree of calcification.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study sought to investigate quantitative and homogeneity differential echogenicity changes of the ABSORB scaffold (1.1) during the first year after implantation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although reactive hyperemia index (RHI) predicts future coronary events, associations with intravascular ultrasound (IVUS)-assessed coronary plaque structure have not been reported. This study therefore investigated associations between RHI and IVUS-assessed coronary plaques. In 362 patients RHI was measured by noninvasive peripheral arterial tonometry and coronary plaque components (fibrous, fibrofatty, necrotic core, and dense calcium) were identified by IVUS in 594 vessel segments of the left anterior descending, circumflex, and/or right coronary arteries. RHI values <1.67 were considered abnormal. Analysis of variance was used to detect independent associations between RHI and plaque composition. Patients with an abnormal RHI had greater plaque burden (41% vs 39% in patients with normal RHI, p = 0.047). Compared to patients with normal RHI, plaque of patients with abnormal RHI had more necrotic core (21% vs 17%, p <0.001) and dense calcium (19% vs 15%, p <0.001) and less fibrous (49% vs 54%, p <0.001) and fibrofatty (11% vs 14%, p = 0.002) tissue. After adjustment for age, gender, cardiovascular risk factors, and drug therapy, abnormal RHI remained significantly associated with fibrous (F ratio 14.79, p <0.001), fibrofatty (F ratio 5.66, p = 0.018), necrotic core (F ratio 14.47, p <0.001), and dense calcium (F ratio 10.80, p = 0.001) volumes. In conclusion, coronary artery plaques of patients with abnormal RHI had a larger proportion of necrotic core and dense calcium. The association of an abnormal RHI with a plaque structure that is more prone to rupture may explain why these patients exhibit a greater risk of coronary events.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background The evaluation of the hepatic parenchyma in patients with chronic liver disease is important to assess the extension, localization and relationship with adjacent anatomical structures of possible lesions. This is usually performed with conventional abdominal ultrasound, CT-scan or magnetic resonance imaging. In this context, the feasibility and the safety of intravascular ultrasound in the liver have not been assessed yet. Methods We tested the safety and performance of an intracardiac echography (ICE) catheter applied by a transjugular approach into the hepatic veins in patients with chronic liver disease undergoing hepatic hemodynamic measurements. Results Five patients were enrolled in this pilot study. The insertion of the ICE catheter was possible into the right and middle, but not into the left hepatic vein. The position of the ICE was followed using fluoroscopy and external conventional ultrasound. Accurate imaging of focal hepatic parenchymal lesions, Doppler ultrasound of surrounding blood vessels and assessment of liver surface and ascites were achieved without complications. Conclusions This study demonstrated that a diagnostic approach using an ICE device inserted in the hepatic veins is feasible, safe and well tolerated. However, it remains for the moment only an experimental investigative tool. Whether ICE adds further information regarding parenchymal lesions and associated vascular alterations as compared to other techniques, needs additional investigation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To demonstrate the feasibility and potential usefulness of an offline fusion of matched optical coherence tomography (OCT) and intravascular ultrasound (IVUS)/virtual histology (IVUS-VH) images.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study sought to investigate in vivo the vascular response at the proximal and distal edges of the second-generation ABSORB everolimus-eluting bioresorbable vascular scaffold (BVS).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To analyse and to compare the changes in the various optical coherence tomography (OCT), echogenicity and intravascular ultrasound virtual histology (VH) of the everolimus-eluting bioresorbable scaffold (ABSORB) degradation parameters during the first 12 months after ABSORB implantation. In the ABSORB study, changes in the appearance of the ABSORB scaffold were monitored over time using various intracoronary imaging modalities. The scaffold struts exhibited a progressive change in their black core area by OCT, in their ultrasound derived grey level intensity quantified by echogenicity, and in their backscattering ultrasound signal, identified as "pseudo dense-calcium" (DC) by VH.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To evaluate the feasibility and effectiveness of IVUS-guided puncture for gaining controlled target lumen reentry in subintimal recanalization of chronic iliac/femoral artery occlusions and in fenestration of aortic dissections. MATERIALS AND METHODS: Between 5/2004 and 12/2005 12 consecutive patients (7 male, 5 female; mean age 64.6 +/- 12.0 years) with chronic critical limb ischemia and ischemic complications of aortic dissection were treated using the Pioneer catheter. This 6.2-F dual-lumen catheter combines a 20-MHz IVUS transducer with a pre-shaped extendable, hollow 24-gauge nitinol needle. This coaxial needle allows real-time IVUS-guided puncture of the target lumen and after successful reentry a 0.014" guidewire may be advanced through the needle into the target lumen. 7 patients were treated for aortic dissection and 5 patients (with failed previous attempts at subintimal recanalization) for chronic arterial occlusion. Patients with aortic dissection (5 type A dissections, 2 type B dissections) had developed renal ischemia (n = 2), renal and mesenteric ischemia (n = 2), or low extremity ischemia (n = 3). Patients with chronic arterial occlusions (2 common iliac artery occlusions, 3 superficial femoral artery occlusions) experienced ischemic rest pain (n = 4), and a non-healing foot ulcer (n = 1). RESULTS: The technical success rate using the Pioneer catheter was 100%. The recanalization/fenestration time was 37 +/- 12 min. Procedure-related complications did not occur. In 10 cases a significant improvement of clinical symptoms was evident. One patient with aortic dissection and ischemic paraplegia required subsequent surgical intervention. One patient had persistent ischemic rest pain despite successful recanalization of a superficial femoral artery occlusion. CONCLUSION: The Pioneer catheter is a reliable device which may be helpful for achieving target lumen reentry in subintimal recanalization of chronic occlusions and in fenestration of aortic dissections.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To report percutaneous fenestration of aortic dissection flaps to relieve distal ischemia using a novel intravascular ultrasound (IVUS)-guided fenestration device. CASE REPORTS: Two men (47 and 62 years of age) with aortic dissection and intermittent claudication had percutaneous ultrasound-guided fenestration performed under local anesthesia. Using an ipsilateral transfemoral approach, the intimal flap was punctured under real-time IVUS guidance using a needle-catheter combination through which a guidewire was placed across the dissection flap into the false lumen. The fenestration was achieved using balloon catheters of increasing diameter introduced over the guidewire. Stenting of the re-entry was performed in 1 patient to equalize pressure across the dissection membrane in both lumens. The procedures were performed successfully and without complications. In both patients, ankle-brachial indexes improved from 0.76 to 1.07 and from 0.8 to 1.1, respectively. Both patients were without claudication at the 3- and 6-month follow-up examination. CONCLUSION: Percutaneous intravascular ultrasound-guided fenestration and stenting at the level of the iliac artery in aortic dissection patients with claudication is a technically feasible and safe procedure and relieves symptoms.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS: To evaluate the plaque composition obtained by virtual histology (VH) IVUS according to the clinical presentation and to compare those data to previously published histopathology data. METHODS AND RESULTS: VH was performed on 95 de novo significant lesions (>75% stenosis) in 85 patients [28 acute coronary syndrome (ACS) patients, 30 lesions; 57 stable angina pectoris (SAP) patients, 65 lesions]. There were a higher prevalence of positive remodelling (47 vs. 22%, P=0.013), thrombus (20 vs. 1.5%, P=0.0037), and echo-lucent area (23.3 vs. 7.7%, P=0.047) in ACS patients. At the minimal lumen site, fibrous plaque area was significantly larger in ACS lesions than in SAP lesions (66.0+/-10.7 vs. 61.4+/-8.9%, P=0.034), whereas necrotic core and dense calcium plaque area were smaller in ACS lesions (Necrotic core: 6.8+/-6.0 vs. 11.0+/-8.3%, P=0.02; Dense calcium: 2.6+/-3.0 vs. 4.9+/-5.8%, P=0.03). No differences in rate of thin cap fibroatheroma, thick fibrotheroma, or for the presence of multiple necrotic core layers were observed between both groups. CONCLUSION: Plaque composition obtained by VH-IVUS shows less necrotic core and more fibrous tissue in ACS compared to SAP lesions, which is in contradiction with previously published histopathologic data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Intravascular ultrasound of drug-eluting stent (DES) thrombosis (ST) reveals a high incidence of incomplete stent apposition (ISA) and vessel remodeling. Autopsy specimens of DES ST show delayed healing and hypersensitivity reactions. The present study sought to correlate histopathology of thrombus aspirates with intravascular ultrasound findings in patients with very late DES ST. METHODS AND RESULTS: The study population consisted of 54 patients (28 patients with very late DES ST and 26 controls). Of 28 patients with very late DES ST, 10 patients (1020+/-283 days after implantation) with 11 ST segments (5 sirolimus-eluting stents, 5 paclitaxel-eluting stents, 1 zotarolimus-eluting stent) underwent both thrombus aspiration and intravascular ultrasound investigation. ISA was present in 73% of cases with an ISA cross-sectional area of 6.2+/-2.4 mm(2) and evidence of vessel remodeling (index, 1.6+/-0.3). Histopathological analysis showed pieces of fresh thrombus with inflammatory cell infiltrates (DES, 263+/-149 white blood cells per high-power field) and eosinophils (DES, 20+/-24 eosinophils per high-power field; sirolimus-eluting stents, 34+/-28; paclitaxel-eluting stents, 6+/-6; P for sirolimus-eluting stents versus paclitaxel-eluting stents=0.09). The mean number of eosinophils per high-power field was higher in specimens from very late DES ST (20+/-24) than in those from spontaneous acute myocardial infarction (7+/-10), early bare-metal stent ST (1+/-1), early DES ST (1+/-2), and late bare-metal stent ST (2+/-3; P from ANOVA=0.038). Eosinophil count correlated with ISA cross-sectional area, with an average increase of 5.4 eosinophils per high-power field per 1-mm(2) increase in ISA cross-sectional area. CONCLUSIONS: Very late DES thrombosis is associated with histopathological signs of inflammation and intravascular ultrasound evidence of vessel remodeling. Compared with other causes of myocardial infarction, eosinophilic infiltrates are more common in thrombi harvested from very late DES thrombosis, particularly in sirolimus-eluting stents, and correlate with the extent of stent malapposition.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: This study aimed to evaluate the degradation rate and long-term vascular responses to the absorbable metal stent (AMS). BACKGROUND: The AMS demonstrated feasibility and safety at 4 months in human coronary arteries. METHODS: The PROGRESS-AMS (Clinical Performance and Angiographic Results of Coronary Stenting) was a prospective, multicenter clinical trial of 63 patients with coronary artery disease who underwent AMS implantation. Angiography and intravascular ultrasound (IVUS) were conducted immediately after AMS deployment and at 4 months. Eight patients who did not require repeat revascularization at 4 months underwent late angiographic and IVUS follow-up from 12 to 28 months. RESULTS: The AMS was well-expanded upon deployment without immediate recoil. The major contributors for restenosis as detected by IVUS at 4 months were: decrease of external elastic membrane volume (42%), extra-stent neointima (13%), and intra-stent neointima (45%). From 4 months to late follow-up, paired IVUS analysis demonstrated complete stent degradation with durability of the 4-month IVUS indexes. The neointima was reduced by 3.6 +/- 5.2 mm(3), with an increase in the stent cross sectional area of 0.5 +/- 1.0 mm(2) (p = NS). The median in-stent minimal lumen diameter was increased from 1.87 to 2.17 mm at long-term follow-up. The median angiographic late loss was reduced from 0.62 to 0.40 mm by quantitative coronary angiography from 4 months to late follow-up. CONCLUSIONS: Intravascular ultrasound imaging supports the safety profile of AMS with degradation at 4 months and maintains durability of the results without any early or late adverse findings. Slower degradation is warranted to provide sufficient radial force to improve long-term patency rates of the AMS.