11 resultados para ICDAS
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
This study compared the performance of fluorescence-based methods, radiographic examination, and International Caries Detection and Assessment System (ICDAS) II on occlusal surfaces. One hundred and nineteen permanent human molars were assessed twice by 2 experienced dentists using the laser fluorescence (LF and LFpen) and fluorescence camera (FC) devices, ICDAS II and bitewing radiographs (BW). After measuring, the teeth were histologically prepared and assessed for caries extension. The sensitivities for dentine caries detection were 0.86 (FC), 0.78 (LFpen), 0.73 (ICDAS II), 0.51 (LF) and 0.34 (BW). The specificities were 0.97 (BW), 0.89 (LF), 0.65 (ICDAS II), 0.63 (FC) and 0.56 (LFpen). BW presented the highest values of likelihood ratio (LR)+ (12.47) and LR- (0.68). Rank correlations with histology were 0.53 (LF), 0.52 (LFpen), 0.41 (FC), 0.59 (ICDAS II) and 0.57 (BW). The area under the ROC curve varied from 0.72 to 0.83. Inter- and intraexaminer intraclass correlation values were respectively 0.90 and 0.85 (LF), 0.93 and 0.87 (LFpen) and 0.85 and 0.76 (FC). The ICDAS II kappa values were 0.51 (interexaminer) and 0.61 (intraexaminer). The BW kappa values were 0.50 (interexaminer) and 0.62 (intraexaminer). The Bland and Altman limits of agreement were 46.0 and 38.2 (LF), 55.6 and 40.0 (LFpen) and 1.12 and 0.80 (FC), for intra- and interexaminer reproducibilities. The posttest probability for dentine caries detection was high for BW and LF. In conclusion, LFpen, FC and ICDAS II presented better sensitivity and LF and BW better specificity. ICDAS II combined with BW showed the best performance and is the best combination for detecting caries on occlusal surfaces.
Resumo:
OBJECTIVES: The aim of this in vitro study was to assess the inter- and intra-examiner reproducibility and the accuracy of the International Caries Detection and Assessment System-II (ICDAS-II) in detecting occlusal caries. METHODS: One hundred and sixty-three molars were independently assessed twice by two experienced dentists using the 0- to 6-graded ICDAS-II. The teeth were histologically prepared and classified using two different histological systems [Ekstrand et al. (1997) Caries Research vol. 31, pp. 224-231; Lussi et al. (1999) Caries Research vol. 33, pp. 261-266] and assessed for caries extension. Sensitivity, specificity, accuracy and area under the ROC curve (A(z)) were obtained at D(2) and D(3) thresholds. Unweighted kappa coefficient was used to assess inter- and intra-examiner reproducibility. RESULTS: For the Ekstrand et al. histological classification the sensitivity was 0.99 and 1.00, specificity 1.00 and 0.69 and accuracy 0.99 and 0.76 at D(2) and D(3), respectively. For the Lussi et al. histological classification the sensitivity was 0.91 and 0.75, specificity 0.47 and 0.62 and accuracy 0.86 and 0.68 at D(2) and D(3), respectively. The A(z) varied from 0.54 to 0.73. The inter- and intra-examiner kappa values were 0.51 and 0.58, respectively. CONCLUSIONS: ICDAS-II presented good reproducibility and accuracy in detecting occlusal caries, especially caries lesions in the outer half of the enamel.
Resumo:
This study aimed to evaluate the effect of an e-learning program on the validity and reproducibility of the International Caries Detection and Assessment System (ICDAS) in detecting occlusal caries. For the study, 170 permanent molars were selected. Four dentists in Switzerland who had no previous contact with ICDAS examined the teeth before and after the e-learning program and scored the sites according to ICDAS. Teeth were histologically prepared and assessed for caries extension. The significance level was set at 0.05. Sensitivity before and after the e-learning program was 0.80 and 0.77 (D1), 0.72 and 0.63 (D2), and 0.74 and 0.67 (D3,4), respectively. Specificity was 0.64 and 0.69 (D1), 0.70 and 0.81 (D2), and 0.81 and 0.87 (D3,4). A McNemar test did not show any difference between the values of sensitivity, specificity, accuracy, and area under the ROC curve (AUC) before and after the e-learning program. The averages of wK values for interexaminer reproducibility were 0.61 (before) and 0.66 (after). Correlation with histology presented wK values of 0.62 (before) and 0.63 (after). A Wilcoxon test showed a statistically significant difference between before and after the e-learning program. In conclusion, even though ICDAS performed well in detecting occlusal caries, the e-learning program did not have any statistically significant effect on its performance by these experienced dentists.
Resumo:
Zielsetzung: Diese Studie untersuchte die Validität und Reliabilität von verschiedenen visuellen dentalen Vergrösserungshilfen in Bezug auf die okklusale Kariesdiagnostik mit Hilfe des International Caries Detection and Assessment System (ICDAS). Material und Methode: Die Okklusalflächen von 100 extrahierten Zähnen wurde an einer zuvor bestimmten Stelle von 10 Studenten (5 Studenten des 3. Jahreskurses (Bachelor-Studenten) und 5 Studenten des 4. Jahreskurses (Master-Studenten) der Zahnmedizinischen Kliniken der Universität Bern) und 4 Zahnärzten visuell untersucht und nach ICDAS auf das Vorhandensein und die Tiefe einer kariösen Läsion beurteilt. Die Beurteilung der Zähne erfolgte je zwei Mal von blossem Auge, mit einem Galilei-Lupensystem (2.5x Vergrösserung), mit einem Kepler-Lupensystem (4.5x Vergrösserung) und mit dem Operationsmikroskop (10x Vergrösserung) mit mindestens 24 Stunden Abstand zwischen den jeweiligen Untersuchungen. Als Goldstandard diente die Histologie. Die statistische Auswertung der Untersuchungen erfolgte mit der Berechnung der Kappa-Koeffizienten für die Intra- und Inter-Untersucher Reliabilität sowie einer Bayes-Analyse durch Ermittlung von Sensitivität, Spezifität und der Fläche unter der Receiver Operating Characteristic Kurve (AUC). Ergebnisse: Bei den Untersuchungsdurchläufen, welche mit dentalen Vergrösserungshilfen für die Diagnostik der okklusalen Zahnoberflächen durchgeführt wurden, sank die Anzahl der mit einem ICDAS-Code 0 (gesunde Zahnoberfläche) beurteilten Zähne, während die Quantität des Codes 3 (Schmelzeinbruch) mit höheren Vergrösserungen drastisch zunahm. Mit steigendem Vergrösserungsfaktor liessen sich sowohl mehr Schmelzkaries als auch Dentinkaries richtig erkennen (bessere Sensitivität), im Gegenzug sanken aber die Werte der Spezifität auf ein klinisch unakzeptables Niveau. Während der Abfall der Spezifität und AUC-Werte bei der Beurteilung von Schmelzkaries unter Verwendung von kleinen Vergrösserungen lediglich einen Trend darstellte, waren die Verschlechterungen in der Diagnostik bei der Dentinkaries unter der Zuhilfenahme von höheren Vergrösserungen häufig signifikant. So stiegen zum Beispiel bei den Zahnärzten die Werte der Sensitivität (Bandbreite) auf dem D3-Diagnostikniveau von 0.47 (0.17-0.79) bei dem Durchlauf von Auge auf 0.91 (0.83-1.00) bei der Benutzung des Operationsmikroskopes an, während jedoch die Spezifitätswerte (Bandbreite) von 0.78 (0.58-0.95) auf 0.30 (0.07-0.55) sanken. Ebenfalls einen negativen Einfluss von optischen Hilfsmitteln zeigte sich bei der Inter-Untersucher Reliabilität, während die Intra-Untersucher Reliabilität unbeeinflusst blieb. Die persönliche klinische Erfahrung scheint sowohl in Bezug auf das Mass der Übereinstimmung visueller Kariesdiagnostik als auch auf die Präferenz bei der Vergabe der ICDAS-Codes und somit auf die Werte der Validität einen wesentlichen Faktor auszumachen. Die Studenten erreichten die besten Werte der Sensitivität, indes die Zahnärzte dies bei der Spezifität erzielten. Schlussfolgerung: Insgesamt zeigte sich, dass ICDAS nicht für den zusätzlichen Gebrauch von optischen Vergrösserungen konzipiert wurde. Da es auf Grund von der Zuhilfenahme von dentalen Vergrösserungen zu mehr und unnötigen invasiven Behandlungsentscheidungen kommen könnte, ist von der Zuhilfenahme derselben für die okklusale Kariesdiagnostik mit ICDAS abzuraten.
Resumo:
The aim of this study was to test the influence of different degrees of additional illumination on visual caries detection using the International Caries Detection and Assessment System (ICDAS). Two calibrated examiners assessed 139 occlusal surfaces of extracted permanent molars using a standard operation lamp with or without an additional headlamp providing three default brightness intensities. Histology served as the gold standard. Pooled data showed no differences in sensitivities. Specificities were not influenced by additional light. The area under the curve for the Marthaler classification D3 threshold was significantly lower when an additional strong headlamp was used (0.59 compared to 0.69-0.72 when reduced illumination intensities were used). One of the two examiners also had a significantly lower sensitivity for the D1 threshold when an additional headlamp was used. The use of additional white light led to a reduced detection of dentine lesions.
Resumo:
OBJECTIVES The aim of this in vitro study was to examine the effect of different levels of magnification on the accuracy and reliability of visual caries detection using ICDAS criteria. METHODS Occlusal surfaces of 100 extracted molars were assessed by 14 examiners (3rd and the 4th year dental students and dentists) using no magnification aids, a 2.5× Galilean loupe, a 4.5× Keplerian loupe, or a surgical microscope with 10× magnification. The assessments were repeated on a different day. Sensitivity, specificity, AUC and reliabilities were calculated according to the gold standard of histology. RESULTS We found that with increasing magnification, the number of surfaces rated as "sound" (ICDAS code 0) decreased, while the number of surfaces with a localized enamel breakdown (ICDAS code 3) increased. While the sensitivities increased, the values of the specificities decreased to an unacceptably low level irrespective of the clinical experience of the examiners. CONCLUSIONS ICDAS seems to be optimized for natural vision up to 2.0× magnification and not for high magnifications. The use of powerful magnification in visual caries detection involves the risk of unnecessary and premature invasive treatment. CLINICAL SIGNIFICANCE This paper discusses when it does and does not make sense to use magnification devices for visual caries detection using ICDAS criteria. Strong magnifications should be refrained from for this purpose.
Resumo:
AIM This study aimed to evaluate the effect of a digital learning tool on undergraduate dental students' performance in detecting dental caries using ICDAS. METHODS An experimental digital learning tool (DLT) was created using digital photographs of sound and carious teeth. Thirty-nine students were divided into three groups (n = 13) and each assessed 12 randomly allocated patients before and after learning strategies: G1, ICDAS e-learning program; G2, ICDAS e-learning program plus DLT; G3, no learning strategy. Students (n = 32) reassessed patients 2 weeks after training. RESULTS Comparing before and after the learning strategies, any difference in the values of specificity and area under the ROC curve for all groups was found. Sensitivity was statistically significantly higher for G1 and G2. Comparing the groups, G2 showed a significant increase in sensitivity at the D2 and D3 thresholds. Spearman's correlations with the gold standard before and after the learning strategy were 0.60 and 0.61 for G1, 0.57 and 0.63 for G2, and 0.54 and 0.54 for G3, respectively. The Wilcoxon test showed a statistically significant difference between the values obtained before and after learning strategies for G1 and G2. CONCLUSIONS Use of the DLT after the ICDAS e-learning program tended to increase the sensitivity of ICDAS used by undergraduate dental students. The DLT appeared to improve dental students' ability to use ICDAS.
Resumo:
The aim of this in vitro study was to compare the performance of two laser fluorescence devices (LF, LFpen), conventional visual criteria (VE), ICDAS and radiographic examination on occlusal surfaces of primary teeth. Thirty-seven primary human molars were selected from a pool of extracted teeth, which were stored frozen at -20°C until use. Teeth were assessed twice by two experienced examiners using laser fluorescence devices (LF and LFpen), conventional visual criteria, ICDAS and bitewing radiographs, with a 2-week interval between measurements. After measurement, the teeth were histologically prepared and assessed for caries extension. The highest sensitivity was observed for ICDAS at D(1) and D(3) thresholds, with no statistically significant difference when compared to the LF devices, except at the D(3) threshold. Bitewing radiographs presented the lowest values of sensitivity. Specificity at D(1) was higher for LFpen (0.90) and for VE at D(3) (0.94). When VE was combined with LFpen the post-test probabilities were the highest (94.0% and 89.2% at D(1) and D(3) thresholds, respectively). High values were observed for the combination of ICDAS and LFpen (92.0% and 80.0%, respectively). LF and LFpen showed the highest values of ICC for interexaminer reproducibility. However, regarding ICDAS, BW and VE, intraexaminer reproducibility was not the same for the two examiners. After primary visual inspection using ICDAS or not, the use of LFpen may aid in the detection of occlusal caries in primary teeth. Bitewing radiographs may be indicated only for approximal caries detection.
Resumo:
This study aimed to assess the performance of International Caries Detection and Assessment System (ICDAS), radiographic examination, and fluorescence-based methods for detecting occlusal caries in primary teeth. One occlusal site on each of 79 primary molars was assessed twice by two examiners using ICDAS, bitewing radiography (BW), DIAGNOdent 2095 (LF), DIAGNOdent 2190 (LFpen), and VistaProof fluorescence camera (FC). The teeth were histologically prepared and assessed for caries extent. Optimal cutoff limits were calculated for LF, LFpen, and FC. At the D (1) threshold (enamel and dentin lesions), ICDAS and FC presented higher sensitivity values (0.75 and 0.73, respectively), while BW showed higher specificity (1.00). At the D (2) threshold (inner enamel and dentin lesions), ICDAS presented higher sensitivity (0.83) and statistically significantly lower specificity (0.70). At the D(3) threshold (dentin lesions), LFpen and FC showed higher sensitivity (1.00 and 0.91, respectively), while higher specificity was presented by FC (0.95), ICDAS (0.94), BW (0.94), and LF (0.92). The area under the receiver operating characteristic (ROC) curve (Az) varied from 0.780 (BW) to 0.941 (LF). Spearman correlation coefficients with histology were 0.72 (ICDAS), 0.64 (BW), 0.71 (LF), 0.65 (LFpen), and 0.74 (FC). Inter- and intraexaminer intraclass correlation values varied from 0.772 to 0.963 and unweighted kappa values ranged from 0.462 to 0.750. In conclusion, ICDAS and FC exhibited better accuracy in detecting enamel and dentin caries lesions, whereas ICDAS, LF, LFpen, and FC were more appropriate for detecting dentin lesions on occlusal surfaces in primary teeth, with no statistically significant difference among them. All methods presented good to excellent reproducibility.
Resumo:
The aim of this study was to test a newly developed LED-based fluorescence device for approximal caries detection in vitro. We assembled 120 extracted molars without frank cavitations or fillings pairwise in order to create contact areas. The teeth were independently assessed by two examiners using visual caries detection (International Caries Detection and Assessment System, ICDAS), bitewing radiography (BW), laser fluorescence (LFpen), and LED fluorescence (Midwest Caries I.D., MW). The measurements were repeated at least 1 week later. The diagnostic performance was calculated with Bayesian analyses. Post-test probabilities were calculated in order to judge the diagnostic performance of combined methods. Reliability analyses were performed using kappa statistics for nominal data and intraclass correlation (ICC) for absolute data. Histology served as the gold standard. Sensitivities/specificities at the enamel threshold were 0.33/0.84 for ICDAS, 0.23/0.86 for BW, 0.47/0.78 for LFpen, and 0.32/0.87 for MW. Sensitivities/specificities at the dentine threshold were 0.04/0.89 for ICDAS, 0.27/0.94 for BW, 0.39/0.84 for LFpen, and 0.07/0.96 for MW. Reliability data were fair to moderate for MW and good for BW and LFpen. The combination of ICDAS and radiography yielded the best diagnostic performance (post-test probability of 0.73 at the dentine threshold). The newly developed LED device is not able to be recommended for approximal caries detection. There might be too much signal loss during signal transduction from the occlusal aspect to the proximal lesion site and the reverse.