56 resultados para Hounsfield Units
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
OBJECTIVE: To assess the reliability of computed tomography (CT) numbers, also known as Hounsfield-units (HU) in the differentiation and identification of forensically relevant materials and to provide instructions to improve the reproducibility of HU measurements in daily forensic practice. MATERIALS AND METHODS: We scanned a phantom containing non-organic materials (glass, rocks and metals) on three different CT scanners with standardized parameters. The t-test was used to assess the influence of the scanner, the size and shape of different types of regions-of-interest (ROI), the composition and shape of the object, and the reader performance on HU measurements. Intra-class correlation coefficient was used to assess intra- and inter-reader reliability. RESULTS: HU values did not change significantly as a function of ROI-shape or -size (p>0.05). Intra-reader reliability reached ICC values >0.929 (p<0.001). Inter-reader reliability was also excellent with an ICC of 0.994 (p<0.001). Four of seven objects yielded significantly different CT numbers at different levels within the object (p<0.05). In 6/7 objects the HU changed significantly from CT scanner to CT scanner (p<0.05). CONCLUSION: Reproducible CT number measurements can be achieved through correct ROI-placement and repeat measurements within the object of interest. However, HU may differ from CT-scanner to CT-scanner. In order to obtain comparable CT numbers we suggest that a dedicated Forensic Reference Phantom be developed.
Resumo:
The radiological determination of foreign objects in corpses can be difficult if they are fragmented or deformed. With multislice computed tomography, radiodensities--referred to as Hounsfield units (HU)--can be measured. We examined the possibility of differentiating 21 frequently occurring foreign bodies, such as metals, rocks, and different manmade materials by virtue of their HU values. Gold, steel, and brass showed mean HU values of 30671-30710 (upper measurable limit), mean HU values for steel, silver, copper, and limestone were 20346, 16949, 14033, and 2765, respectively. The group consisting of objects, such as aluminum, tarmac, car front-window glass, and other rocks, displayed mean HU values of 2329-2131 HU. The mean HU value of bottle glass and car side-window glass was 2088, whereas windowpane glass was 493. HU value determination may therefore help in preautopsy differentiation between case-relevant and irrelevant foreign bodies and thus be useful for autopsy planning and extraction of the objects in question.
Resumo:
In clinical medicine, plane radiography is used for detecting the remains of medications in the stomach in oral medication intoxication cases. Since postmortem computed tomography (CT), performed prior to autopsy, is currently intensively entering the forensic routine, the technique was applied to three fatal cases of oral medication intoxication. Here we report CT and autopsy findings for these cases. In all three cases, hyperdense areas within the stomach content were documented. The measurement of Hounsfield Units (HU) beyond 74HU showed mean values of 338, 88 and 98HU. Postmortem CT also showed brain edema and pulmonary aspiration in one case. At autopsy, tablet remains in the stomach were detected microscopically in all three cases. The ex vivo CT scans of the ingested medicaments showed similar HU values. Despite the fact that further case studies are necessary beyond this one, and in spite of its limitations, postmortem CT was found to be a useful screening and documentation method for stomach contents in oral medication intoxication.
Resumo:
The aim of this study was to evaluate the use of high resolution CT to radiologically define teeth filling material properties in terms of Hounsfield units after high temperature exposure.
Resumo:
OBJECTIVES: One main problem occurring after bone grafting is resorption, leading to insufficient bone volume and quality, and may subsequently cause dental implant failure. Comparison of graft volume and bone density of iliac crest and calvarial transplants determined by animal studies demonstrates significantly lower resorption of bone grafts harvested from the skull. This paper is the first clinical study evaluating bone volume and density changes of calvarial split bone grafts after alveolar ridge reconstruction. MATERIAL AND METHODS: Bone volume and density were determined using CT scans and the software program Dicom Works in a total of 51 calvarial grafts after alveolar ridge augmentation in 15 patients. CT scans were taken in all 15 patients immediately after grafting (T0) and before implantation after a postoperative period of 6 months (T1). In five patients (26 calvarial grafts), a 1-year follow-up was performed (T2). RESULTS: A mean volume reduction of 16.2% at T1 (15 patients) and 19.2% at T2 (five patients) was observed. Bone density was high--about 1000 Hounsfield units--and did not change during the 1-year period. At the time of implantation, 41 transplants were classified as quality 1 bone and 10 as quality 2-3 bone. Grafting area and the technique used for grafting (inlay or onlay graft) did not affect the postoperative bone volume reduction. Generalized osteoporosis did not increase the resorption rate of calvarial transplants. CONCLUSION: Based on these findings, calvarial split bone grafts are a promising alternative for alveolar ridge reconstruction in dental implantology.
Resumo:
Dental identification is the most valuable method to identify human remains in single cases with major postmortem alterations as well as in mass casualties because of its practicability and demanding reliability. Computed tomography (CT) has been investigated as a supportive tool for forensic identification and has proven to be valuable. It can also scan the dentition of a deceased within minutes. In the present study, we investigated currently used restorative materials using ultra-high-resolution dual-source CT and the extended CT scale for the purpose of a color-encoded, in scale, and artifact-free visualization in 3D volume rendering. In 122 human molars, 220 cavities with 2-, 3-, 4- and 5-mm diameter were prepared. With presently used filling materials (different composites, temporary filling materials, ceramic, and liner), these cavities were restored in six teeth for each material and cavity size (exception amalgam n = 1). The teeth were CT scanned and images reconstructed using an extended CT scale. Filling materials were analyzed in terms of resulting Hounsfield units (HU) and filling size representation within the images. Varying restorative materials showed distinctively differing radiopacities allowing for CT-data-based discrimination. Particularly, ceramic and composite fillings could be differentiated. The HU values were used to generate an updated volume-rendering preset for postmortem extended CT scale data of the dentition to easily visualize the position of restorations, the shape (in scale), and the material used which is color encoded in 3D. The results provide the scientific background for the application of 3D volume rendering to visualize the human dentition for forensic identification purposes.
Resumo:
OBJECTIVE: Smuggling dissolved drugs, especially cocaine, in bottled liquids is an ongoing problem at borders. Common fluoroscopy of packages at the border cannot detect contaminated liquids. The objective of our study was to develop an MDCT screening method to detect cocaine-containing vessels that are hidden between uncontaminated ones in a shipment. MATERIALS AND METHODS: Studies were performed on three wine bottles containing cocaine solutions that were confiscated at the Swiss border. Reference values were obtained by scans of different sorts of commercially available wine and aqueous solutions of dissolved sugar. All bottles were scanned using MDCT, and data evaluation was performed by measuring the mean peak of Hounsfield units. To verify the method, simulated testing was performed. RESULTS: Using measurements of the mean peak of Hounsfield units enables the detection of dissolved cocaine in wine bottles in a noninvasive and rapid fashion. Increasing opacity corresponds well with the concentration of dissolved cocaine. Simulated testing showed that it is possible to distinguish between cocaine-contaminated and uncontaminated wine bottles. CONCLUSION: The described method is an efficacious screening method to detect cocaine-contaminated bottles that are hidden between untreated bottles in cargo. The noninvasive examination of cargo allows a questionable delivery to be tracked without arousing the suspicion of the smugglers.
Resumo:
OBJECTIVE: The objective of the study was to evaluate tissue reactions such as bone genesis, cartilage genesis and graft materials in the early phase of lumbar intertransverse process fusion in a rabbit model using computed tomography (CT) imaging with CT intensity (Hounsfield units) measurement, and to compare these data with histological results. MATERIALS AND METHODS: Lumbar intertransverse process fusion was performed on 18 rabbits. Four graft materials were used: autograft bone (n = 3); collagen membrane soaked with recombinant human bone morphogenetic protein-2 (rhBMP-2) (n = 5); granular calcium phosphate (n = 5); and granular calcium phosphate coated with rhBMP-2 (n = 5). All rabbits were euthanized 3 weeks post-operatively and lumbar spines were removed for CT imaging and histological examination. RESULTS: Computed tomography imaging demonstrated that each fusion mass component had the appropriate CT intensity range. CT also showed the different distributions and intensities of bone genesis in the fusion masses between the groups. Each component of tissue reactions was identified successfully on CT images using the CT intensity difference. Using CT color mapping, these observations could be easily visualized, and the results correlated well with histological findings. CONCLUSIONS: The use of CT intensity is an effective approach for observing and comparing early tissue reactions such as newly synthesized bone, newly synthesized cartilage, and graft materials after lumbar intertransverse process fusion in a rabbit model.
Resumo:
HYPOTHESIS: Chronic rotator cuff tears are associated with irreversible architectural muscle changes and a high rate of repair failure. The changes observed in man and their irreversibility with a single stage repair can be reproduced in sheep. It was the purpose of this experiment to test the hypothesis that slow, continuous elongation of a retracted musculotendinous unit allows reversal of the currently irreversible structural muscle changes. MATERIALS AND METHODS: The infraspinatus tendon of 12 sheep was released using a greater tuberosity osteotomy and allowed to retract for 4 months. Then, a new device was mounted on the scapular spine and used to extend the infraspinatus muscuculotendinous unit transcutaneously by 1 mm per day. Thereafter, the tendon was repaired back to the greater tuberosity. We assessed the muscular architecture using magnetic resonance imaging, macroscopic dissection, histology, and electron microscopy. Fatty infiltration (in Hounsfield units 1/4 HU) and muscular cross-sectional area (in % of the control side) were monitored with computed tomography at tendon release, initiation of elongation, repair, and at sacrifice. RESULTS: Sixteen weeks after tendon release, the mean tendon retraction was 29 +/- 6 mm (14% of original length, P = .008). In 8 sheep, elongation was achieved as planned (group I), but in 4, the elongation failed technically (group II). The mean traction time was 24 +/- 6 days with a mean traction distance of 19 +/- 4 mm. At sacrifice, the mean pennation angle in the infraspinatus of group I was not different from the control side (29.8 degrees +/-7.5 degrees vs. 30 degrees +/-6 degrees , P = .575). In group II, the pennation angle had increased from 30 degrees +/-6 degrees to 55 degrees +/-14 degrees (P = .035). There was no fatty infiltration at the time of tendon release. After retraction, there was a significant increase in fatty infiltration of the infraspinatus muscle and a decrease of its cross-sectional area to 57% of the contralateral side (P = .0001). During traction, the degree of fatty infiltration remained unchanged (36 HU to 38 HU, P = .381), and atrophy improved to a muscle square area of 78% of the contralateral side (P = .0001) in group I. In group II, an increase of fatty infiltration was measured from 36 HU to 28 HU; however, this increase was not significant (P = .144). Atrophy did not change in group II (57-55%, P = .946). At sacrifice, the remaining muscle mass was 64% in group I and 46% in group II (P = .019). DISCUSSION: Our preliminary results document, that continuous elongation of a retracted, fatty infiltrated and atrophied musculotendinous unit is technically feasible. CONCLUSION: In the sheep, continuous elongation can lead to restoration of normal muscle architecture, to partial reversal of muscle atrophy, and to arrest of the progression of fatty infiltration. LEVEL OF EVIDENCE: Basic science level 2; Prospective comparative therapeutic study.
Resumo:
BACKGROUND Tooth root problems and periodontal diseases are common in South American camelids (SAC). The objective was to evaluate and optimize the imaging technique for dental radiography in SAC and to describe the radiographic and computed tomographic (CT) anatomy of normal teeth at different ages. In this study, the heads of 20 healthy SAC slaughtered for meat production or euthanized for reasons not related to dental problems included 7 female and 10 male llamas and 3 male alpacas. Using a standardized protocol, radiographs and CT scans of the 20 specimen were performed. RESULTS The most useful radiographic projections for mandibular and maxillary cheek teeth evaluation turned out to be lateral30°ventral-laterodorsal and lateral30°dorsal-lateroventral with slight separation of the dental arcades respectively. Digital radiographic and CT appearance of the mandibular and maxillary teeth were described from the beginning of mineralization till maturity. In addition the normal range of the CT radio density of different cheek teeth and different dental tissues were measured. Hounsfield units of different dental tissues of SAC turned out to be similar to equids. Deviation, shortening and partial destruction of the distal tooth root of mandibular 09's and 10's and of maxillary 09's was observed and the existence of a common pulp chamber in younger teeth was revealed. CONCLUSIONS The present study provides information about the dental imaging morphology in clinically healthy SAC. This basic information provides fundamental knowledge for evaluating images and planning treatments in clinically affected animals.
Resumo:
To investigate the effect of metal implants in proton radiotherapy, dose distributions of different, clinically relevant treatment plans have been measured in an anthropomorphic phantom and compared to treatment planning predictions. The anthropomorphic phantom, which is sliced into four segments in the cranio-caudal direction, is composed of tissue equivalent materials and contains a titanium implant in a vertebral body in the cervical region. GafChromic® films were laid between the different segments to measure the 2D delivered dose. Three different four-field plans have then been applied: a Single-Field-Uniform-Dose (SFUD) plan, both with and without artifact correction implemented, and an Intensity-Modulated-Proton-Therapy (IMPT) plan with the artifacts corrected. For corrections, the artifacts were manually outlined and the Hounsfield Units manually set to an average value for soft tissue. Results show a surprisingly good agreement between prescribed and delivered dose distributions when artifacts have been corrected, with > 97% and 98% of points fulfilling the gamma criterion of 3%/3 mm for both SFUD and the IMPT plans, respectively. In contrast, without artifact corrections, up to 18% of measured points fail the gamma criterion of 3%/3 mm for the SFUD plan. These measurements indicate that correcting manually for the reconstruction artifacts resulting from metal implants substantially improves the accuracy of the calculated dose distribution.
Resumo:
PURPOSE The purpose of this study was to compare postmortem computed tomography with forensic autopsy regarding their diagnostic reliability of differentiating between pre-existing cerebral edema and physiological postmortem brain swelling. MATERIALS AND METHODS The study collective included a total of 109 cases (n=109/200, 83 male, 26 female, mean age: 53.2 years) and were retrospectively evaluated for the following parameters (as related to the distinct age groups and causes of death): tonsillar herniation, the width of the outer and inner cerebrospinal fluid spaces and the radiodensity measurements (in Hounsfield Units) of the gray and white matter. The results were compared with the findings of subsequent autopsies as the gold standard for diagnosing cerebral edema. p-Values <0.05 were considered statistically significant. RESULTS Cerebellar edema (despite normal postmortem swelling) can be reliably assessed using postmortem computed tomography and is indicated by narrowed temporal horns and symmetrical herniation of the cerebellar tonsils (p<0.001). There was a significant difference (p<0.001) between intoxication (or asphyxia) and all other causes of death; the former causes demonstrated higher deviations of the attenuation between white and gray matter (>20 Hounsfield Units), and the gray to white matter ratio was >1.58 when leukoencephalopathy was excluded. CONCLUSIONS Despite normal postmortem changes, generalized brain edema can be differentiated on postmortem computed tomography, and white and gray matter Hounsfield measurements help to determine the cause of death in cases of intoxication or asphyxia. Racking the brain about feasible applications for a precise and reliable brain diagnostic forensic radiology method has just begun.
Resumo:
The aim of this survey was to investigate clinicians' current approach to the haemodynamic management and resuscitation endpoints in septic shock.
Resumo:
Refinement in microvascular reconstructive techniques over the last 30 years has enabled an increasing number of patients to be rehabilitated for both functional and aesthetic reasons. The purpose of this study was to evaluate different microsurgical practice, including perioperative management, in Germany, Austria, and Switzerland. The DÖSAK collaborative group for Microsurgical Reconstruction developed a detailed questionnaire which was circulated to units in the three countries. The current practice of the departments was evaluated. Thirty-eight questionnaires were completed resulting in a 47.5% response rate. A considerable variation in the number of microsurgical reconstructions per year was noted. In relation to the timing of bony reconstruction, 10 hospitals did reconstructions primarily (26.3%), 19 secondarily (50%) and 9 (23.7%) hospitals used both concepts. In the postoperative course, 15.8% of hospitals use inhibitors of platelet aggregation, most hospitals use low molecular heparin (52.6%) or other heparin products (44.7%). This survey shows variation in the performance, management, and care of microsurgical reconstructions of patients. This is due in part to the microvascular surgeons available in the unit but it is also due to different types of hospitals where various types of care can be performed in these patients needing special perioperative care.