42 resultados para Horizontal alignment
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
AIMS: To study if minimally invasive strabismus surgery (MISS) is suitable for rectus muscle reoperations. METHODS: The study presents a series of consecutive patients operated on by the same surgeon at Kantonsspital St Gallen, Switzerland with a novel MISS rectus muscle reoperation technique. Surgery is done by applying two small radial cuts along the muscle insertion. Through the tunnel obtained after muscle separation from surrounding tissue, a recession, advancement or plication is performed. RESULTS: In 62 eyes of 51 patients (age 35.4 (SD 16.3) years) a total of 86 horizontal rectus muscles were reoperated. On the average, the patients had 2.1 strabismus surgeries previously. Preoperative logMAR visual acuity was 0.38 (0.82) compared with 0.37 (0.83) at 6 months (p>0.1). On the first postoperative day, in the primary gaze position conjunctival and lid swelling and redness was hardly visible in 11 eyes, discrete in 15 eyes, moderate in 11 eyes and severe in 15 eyes. One corneal dellen and one corneal erosion occurred, which both quickly resolved. The preoperative deviation at distance for esodeviations (n = 15) of 12.5 (8.5) degrees decreased to 2.6 (7.8) degrees at 6 months (p<0.001). For near, a decrease from 12.0 (10.1) degrees to 2.9 (1.6) degrees was observed (p<0.001). The preoperative deviation at distance for exodeviations (n = 35) of -16.4 (8.5) degrees decreased to -7.9 (6.5) degrees at 6 months (p<0.005). For near, a decrease from -16.5 (11.4) degrees to -2.9 (1.5) degrees was observed (p<0.005). Within the first 6 months, only one patient had a reoperation. At month 6, in four patients a reoperation was planned or suggested by us because of unsatisfactory alignment. No patient experienced persistent diplopia or necessitated a reoperation because of double vision. Stereovision improved at month 6 compared with preoperatively (p<0.01). CONCLUSIONS: The study demonstrates that a small-cut, minimal dissection technique allows to perform rectus muscle reoperations. The MISS technique seems to reduce conjunctival and lid swelling in the direct postoperative period.
Resumo:
PURPOSE Dyslexia is the most common developmental reading disorder that affects language skills. Latent strabismus (heterophoria) has been suspected to be causally involved. Even though phoria correction in dyslexic children is commonly applied, the evidence in support of a benefit is poor. In order to provide experimental evidence on this issue, we simulated phoria in healthy readers by modifying the vergence tone required to maintain binocular alignment. METHODS Vergence tone was altered with prisms that were placed in front of one eye in 16 healthy subjects to induce exophoria, esophoria, or vertical phoria. Subjects were to read one paragraph for each condition, from which reading speed was determined. Text comprehension was tested with a forced multiple choice test. Eye movements were recorded during reading and subsequently analyzed for saccadic amplitudes, saccades per 10 letters, percentage of regressive (backward) saccades, average fixation duration, first fixation duration on a word, and gaze duration. RESULTS Acute change of horizontal and vertical vergence tone does neither significantly affect reading performance nor reading associated eye movements. CONCLUSION Prisms in healthy subjects fail to induce a significant change of reading performance. This finding is not compatible with a role of phoria in dyslexia. Our results contrast the proposal for correcting small angle heterophorias in dyslexic children.
Resumo:
Accurate placement of lesions is crucial for the effectiveness and safety of a retinal laser photocoagulation treatment. Computer assistance provides the capability for improvements to treatment accuracy and execution time. The idea is to use video frames acquired from a scanning digital ophthalmoscope (SDO) to compensate for retinal motion during laser treatment. This paper presents a method for the multimodal registration of the initial frame from an SDO retinal video sequence to a retinal composite image, which may contain a treatment plan. The retinal registration procedure comprises the following steps: 1) detection of vessel centerline points and identification of the optic disc; 2) prealignment of the video frame and the composite image based on optic disc parameters; and 3) iterative matching of the detected vessel centerline points in expanding matching regions. This registration algorithm was designed for the initialization of a real-time registration procedure that registers the subsequent video frames to the composite image. The algorithm demonstrated its capability to register various pairs of SDO video frames and composite images acquired from patients.
Resumo:
The purpose of the present retrospective study was to evaluate the post-traumatic healing of the pulp and periodontium of 32 permanent teeth with horizontal root fractures. Twenty-nine patients, 8-48 years old, who presented at our department with a root fracture between January 2001 and April 2007, participated in the study. Root-fractured teeth with a loosened or dislocated coronal fragment were repositioned and splinted for 14-49 days (average: 34 days). In cases of severe dislocation of the coronal fragment, prophylactic endodontic treatment was performed. Follow-up examinations were conducted routinely after 1,2,3,6, and 12 months. For this study, follow-up took place for up to 7 years post trauma. Of 32 root-fractured teeth, 29 (91%) survived. 10 teeth (31%) exhibited pulpal healing; 13 teeth (41%) were prophylactically endodontically treated within 2 weeks of injury. At the fracture line, interposition of calcified tissue was evident in 6 teeth (19%), and interposition of granulation tissue was observed in 8 teeth (25%). The prognosis of the root-fractured teeth was good, and one-third of the teeth with root fractures possessed a vital pulp at the final examination.
Resumo:
During development and regeneration of the mammalian nervous system, directional signals guide differentiating neurons toward their targets. Soluble neurotrophic molecules encode for preferential direction over long distances while the local topography is read by cells in a process requiring the establishment of focal adhesions. The mutual interaction between overlapping molecular and topographical signals introduces an additional level of control to this picture. The role of the substrate topography was demonstrated exploiting nanotechnologies to generate biomimetic scaffolds that control both the polarity of differentiating neurons and the alignment of their neurites. Here PC12 cells contacting nanogratings made of copolymer 2-norbornene ethylene (COC), were alternatively stimulated with Nerve Growth Factor, Forskolin, and 8-(4-chloro-phenylthio)-2'-O-methyladenosine-3',5'-cyclic (8CPT-2Me-cAMP) or with a combination of them. Topographical guidance was differently modulated by the alternative stimulation protocols tested. Forskolin stimulation reduced the efficiency of neurite alignment to the nanogratings. This effect was linked to the inhibition of focal adhesion maturation. Modulation of neurite alignment and focal adhesion maturation upon Forskolin stimulation depended on the activation of the MEK/ERK signaling but were PkA independent. Altogether, our results demonstrate that topographical guidance in PC12 cells is modulated by the activation of alternative neuronal differentiation pathways.
Resumo:
Computer navigation in total knee arthroplasty is somewhat controversial. We have previously shown that femoral component positioning is more accurate with computed navigation than with conventional implantation techniques, but the clinical impact of this is unknown. We now report the 5-year outcome of our previously reported 2-year outcome study.
High accuracy alignment facility for the receiver and transmitter of the BepiColombo Laser Altimeter
Resumo:
The accurate co-alignment of the transmitter to the receiver of the BepiColombo Laser Altimeter is a challenging task for which an original alignment concept had to be developed. We present here the design, construction and testing of a large collimator facility built to fulfill the tight alignment requirements. We describe in detail the solution found to attenuate the high energy of the instrument laser transmitter by an original beam splitting pentaprism group. We list the different steps of the calibration of the alignment facility and estimate the errors made at each of these steps. We finally prove that the current facility is ready for the alignment of the flight instrument. Its angular accuracy is 23 μrad.