26 resultados para High Reliability

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Osteoarticular allograft is one possible treatment in wide surgical resections with large defects. Performing best osteoarticular allograft selection is of great relevance for optimal exploitation of the bone databank, good surgery outcome and patient’s recovery. Current approaches are, however, very time consuming hindering these points in practice. We present a validation study of a software able to perform automatic bone measurements used to automatically assess the distal femur sizes across a databank. 170 distal femur surfaces were reconstructed from CT data and measured manually using a size measure protocol taking into account the transepicondyler distance (A), anterior-posterior distance in medial condyle (B) and anterior-posterior distance in lateral condyle (C). Intra- and inter-observer studies were conducted and regarded as ground truth measurements. Manual and automatic measures were compared. For the automatic measurements, the correlation coefficients between observer one and automatic method, were of 0.99 for A measure and 0.96 for B and C measures. The average time needed to perform the measurements was of 16 h for both manual measurements, and of 3 min for the automatic method. Results demonstrate the high reliability and, most importantly, high repeatability of the proposed approach, and considerable speed-up on the planning.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The original 'Örebro Musculoskeletal Pain Questionnaire' (original-ÖMPQ) has been shown to have limitations in practicality, factor structure, face and content validity. This study addressed these concerns by modifying its content producing the 'Örebro Musculoskeletal Screening Questionnaire' (ÖMSQ). The ÖMSQ and original-ÖMPQ were tested concurrently in acute/subacute low back pain working populations (pilot n = 44, main n = 106). The ÖMSQ showed improved face and content validity, which broadened potential application, and improved practicality with two-thirds less missing responses. High reliability (0.975, p < 0.05, ICC: 2.1), criterion validity (Spearman's r = 0.97) and internal consistency (α = 0.84) were achieved, as were predictive ability cut-off scores from ROC curves (112-120 ÖMSQ-points), statistically different ÖMSQ scores (p < 0.001) for each outcome trait, and a strong correlation with recovery time (Spearman's, r = 0.71). The six-component factor structure reflected the constructs originally proposed. The ÖMSQ can be substituted for the original-ÖMPQ in this population. Further research will assess its applicability in broader populations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Low back pain (LBP) is currently the most prevalent and costly musculoskeletal problem in modern societies. Screening instruments for the identification of prognostic factors in LBP may help to identify patients with an unfavourable outcome. In this systematic review screening instruments published between 1970 and 2007 were identified by a literature search. Nine different instruments were analysed and their different items grouped into ten structures. Finally, the predictive effectiveness of these structures was examined for the dependent variables including "work status", "functional limitation", and "pain". The strongest predictors for "work status" were psychosocial and occupational structures, whereas for "functional limitation" and "pain" psychological structures were dominating. Psychological and occupational factors show a high reliability for the prognosis of patients with LBP. Screening instruments for the identification of prognostic factors in patients with LBP should include these factors as a minimum core set.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND AND AIMS: Internet-based surveys provide a potentially important tool for Inflammatory Bowel Disease (IBD) research. The advantages include low cost, large numbers of participants, rapid study completion and less extensive infrastructure than traditional methods. The aim was to determine the accuracy of patient self-reporting in internet-based IBD research and identify predictors of greater reliability. METHODS: 197 patients from a tertiary care center answered an online survey concerning personal medical history and an evaluation of disease specific knowledge. Self-reported medical details were compared with data abstracted from medical records. Agreement was assessed by kappa (κ) statistics. RESULTS: Participants responded correctly with excellent agreement (κ=0.96-0.97) on subtype of IBD and history of surgery. The agreement was also excellent for colectomy (κ=0.88) and small bowel resection (κ=0.91), moderate for abscesses and fistulas (κ=0.60 and 0.63), but poor regarding partial colectomy (κ=0.39). Time since last colonoscopy was self-reported with better agreement (κ=0.84) than disease activity. For disease location/extent, moderate agreements at κ=69% and 64% were observed for patients with Crohn's disease and ulcerative colitis, respectively. Subjects who scored higher than the average in the IBD knowledge assessment were significantly more accurate about disease location than their complementary group (74% vs. 59%, p=0.02). CONCLUSION: This study demonstrates that IBD patients accurately report their medical history regarding type of disease and surgical procedures. More detailed medical information is less reliably reported. Disease knowledge assessment may help in identifying the most accurate individuals and could therefore serve as validity criteria. Internet-based surveys are feasible with high reliability about basic disease features only. However, the participants in this study were engaged at a tertiary center, which potentially leads to a bias and compromises generalization to an unfiltered patient group.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The proliferation of multimedia content and the demand for new audio or video services have fostered the development of a new era based on multimedia information, which allowed the evolution of Wireless Multimedia Sensor Networks (WMSNs) and also Flying Ad-Hoc Networks (FANETs). In this way, live multimedia services require real-time video transmissions with a low frame loss rate, tolerable end-to-end delay, and jitter to support video dissemination with Quality of Experience (QoE) support. Hence, a key principle in a QoE-aware approach is the transmission of high priority frames (protect them) with a minimum packet loss ratio, as well as network overhead. Moreover, multimedia content must be transmitted from a given source to the destination via intermediate nodes with high reliability in a large scale scenario. The routing service must cope with dynamic topologies caused by node failure or mobility, as well as wireless channel changes, in order to continue to operate despite dynamic topologies during multimedia transmission. Finally, understanding user satisfaction on watching a video sequence is becoming a key requirement for delivery of multimedia content with QoE support. With this goal in mind, solutions involving multimedia transmissions must take into account the video characteristics to improve video quality delivery. The main research contributions of this thesis are driven by the research question how to provide multimedia distribution with high energy-efficiency, reliability, robustness, scalability, and QoE support over wireless ad hoc networks. The thesis addresses several problem domains with contributions on different layers of the communication stack. At the application layer, we introduce a QoE-aware packet redundancy mechanism to reduce the impact of the unreliable and lossy nature of wireless environment to disseminate live multimedia content. At the network layer, we introduce two routing protocols, namely video-aware Multi-hop and multi-path hierarchical routing protocol for Efficient VIdeo transmission for static WMSN scenarios (MEVI), and cross-layer link quality and geographical-aware beaconless OR protocol for multimedia FANET scenarios (XLinGO). Both protocols enable multimedia dissemination with energy-efficiency, reliability and QoE support. This is achieved by combining multiple cross-layer metrics for routing decision in order to establish reliable routes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Falling on the outstretched hand is a common trauma mechanism. In contrast to fractures of the distal radius, which usually are diagnosed on plain film radiographs, identifying wrist injuries requires further diagnostic methods, e.g., MRI or CT. This article provides a review of the use of MRI in the most common traumatic wrist injuries, including scaphoid fractures, TFCC lesions, and tears of the scapholunate ligament. Early and selective use of MRI as a further diagnostic method in cases of adequate clinical suspicion helps to initiate the correct treatment and, thus, prevents long-term arthrotic injuries and reduces unnecessary absence due to illness. MRI shows a high reliability in the diagnosis of scaphoid fractures and the America College of Radiology recommends MRI as method of choice after X-ray images have been made. In the diagnosis of ligament and discoid lesions, MR arthrography (MRA) using intraarticular contrast agent has considerably higher accuracy than i.v.-enhanced and especially unenhanced MRI.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND Intravenous anaesthetic drugs are the primary means for producing general anaesthesia in equine practice. The ideal drug for intravenous anaesthesia has high reliability and pharmacokinetic properties indicating short elimination and lack of accumulation when administered for prolonged periods. Induction of general anaesthesia with racemic ketamine preceded by profound sedation has already an established place in the equine field anaesthesia. Due to potential advantages over racemic ketamine, S-ketamine has been employed in horses to induce general anaesthesia, but its optimal dose remains under investigation. The objective of this study was to evaluate whether 2.5 mg/kg S-ketamine could be used as a single intravenous bolus to provide short-term surgical anaesthesia in colts undergoing surgical castration, and to report its pharmacokinetic profile. RESULTS After premedication with romifidine and L-methadone, the combination of S-ketamine and diazepam allowed reaching surgical anaesthesia in the 28 colts. Induction of anaesthesia as well as recovery were good to excellent in the majority (n = 22 and 24, respectively) of the colts. Seven horses required additional administration of S-ketamine to prolong the duration of surgical anaesthesia. Redosing did not compromise recovery quality. Plasma concentration of S-ketamine decreased rapidly after administration, following a two-compartmental model, leading to the hypothesis of a consistent unchanged elimination of the parent compound into the urine beside its conversion to S-norketamine. The observed plasma concentrations of S-ketamine at the time of first movement were various and did not support the definition of a clear cut-off value to predict the termination of the drug effect. CONCLUSIONS The administration of 2.5 mg/kg IV S-ketamine after adequate premedication provided good quality of induction and recovery and a duration of action similar to what has been reported for racemic ketamine at the dose of 2.2 mg/kg. Until further investigations will be provided, close monitoring to adapt drug delivery is mandatory, particularly once the first 10 minutes after injection are elapsed. Taking into account rapid elimination of S-ketamine, significant inter-individual variability and rapid loss of effect over a narrow range of concentrations a sudden return of consciousness has to be foreseen.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

High-resolution ultrasound is becoming increasingly important in the diagnosis of carpal tunnel syndrome (CTS). Most studies define cut-off values of the cross-sectional area (CSA) of the median nerve in different locations. The individual range of nerve swelling, the size of the nerve, and its CSA are not addressed. The aim of the study is to define the intra- and interobserver reliability of diagnostic ultrasound using two different cross-sectional areas of the median nerve at the carpal tunnel in predefined locations.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECT: Ultrasound may be a reliable but simpler alternative to intraoperative MR imaging (iMR imaging) for tumor resection control. However, its reliability in the detection of tumor remnants has not been definitely proven. The aim of the study was to compare high-field iMR imaging (1.5 T) and high-resolution 2D ultrasound in terms of tumor resection control. METHODS: A prospective comparative study of 26 consecutive patients was performed. The following parameters were compared: the existence of tumor remnants after presumed radical removal and the quality of the images. Tumor remnants were categorized as: detectable with both imaging modalities or visible only with 1 modality. RESULTS: Tumor remnants were detected in 21 cases (80.8%) with iMR imaging. All large remnants were demonstrated with both modalities, and their image quality was good. Two-dimensional ultrasound was not as effective in detecting remnants<1 cm. Two remnants detected with iMR imaging were missed by ultrasound. In 2 cases suspicious signals visible only on ultrasound images were misinterpreted as remnants but turned out to be a blood clot and peritumoral parenchyma. The average time for acquisition of an ultrasound image was 2 minutes, whereas that for an iMR image was approximately 10 minutes. Neither modality resulted in any procedure-related complications or morbidity. CONCLUSIONS: Intraoperative MR imaging is more precise in detecting small tumor remnants than 2D ultrasound. Nevertheless, the latter may be used as a less expensive and less time-consuming alternative that provides almost real-time feedback information. Its accuracy is highest in case of more confined, deeply located remnants. In cases of more superficially located remnants, its role is more limited.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Pulmonary Embolism Severity Index (PESI) is a validated clinical prognostic model for patients with acute pulmonary embolism (PE). Our goal was to assess the PESI's inter-rater reliability in patients diagnosed with PE. We prospectively identified consecutive patients diagnosed with PE in the emergency department of a Swiss teaching hospital. For all patients, resident and attending physician raters independently collected the 11 PESI variables. The raters then calculated the PESI total point score and classified patients into one of five PESI risk classes (I-V) and as low (risk classes I/II) versus higher-risk (risk classes III-V). We examined the inter-rater reliability for each of the 11 PESI variables, the PESI total point score, assignment to each of the five PESI risk classes, and classification of patients as low versus higher-risk using kappa ( ) and intra-class correlation coefficients (ICC). Among 48 consecutive patients with an objective diagnosis of PE, reliability coefficients between resident and attending physician raters were > 0.60 for 10 of the 11 variables comprising the PESI. The inter-rater reliability for the PESI total point score (ICC: 0.89, 95% CI: 0.81-0.94), PESI risk class assignment ( : 0.81, 95% CI: 0.66-0.94), and the classification of patients as low versus higher-risk ( : 0.92, 95% CI: 0.72-0.98) was near perfect. Our results demonstrate the high reproducibility of the PESI, supporting the use of the PESI for risk stratification of patients with PE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Many medical exams use 5 options for multiple choice questions (MCQs), although the literature suggests that 3 options are optimal. Previous studies on this topic have often been based on non-medical examinations, so we sought to analyse rarely selected, 'non-functional' distractors (NF-D) in high stakes medical examinations, and their detection by item authors as well as psychometric changes resulting from a reduction in the number of options. Methods Based on Swiss Federal MCQ examinations from 2005-2007, the frequency of NF-D (selected by <1% or <5% of the candidates) was calculated. Distractors that were chosen the least or second least were identified and candidates who chose them were allocated to the remaining options using two extreme assumptions about their hypothetical behaviour: In case rarely selected distractors were eliminated, candidates could randomly choose another option - or purposively choose the correct answer, from which they had originally been distracted. In a second step, 37 experts were asked to mark the least plausible options. The consequences of a reduction from 4 to 3 or 2 distractors - based on item statistics or on the experts' ratings - with respect to difficulty, discrimination and reliability were modelled. Results About 70% of the 5-option-items had at least 1 NF-D selected by <1% of the candidates (97% for NF-Ds selected by <5%). Only a reduction to 2 distractors and assuming that candidates would switch to the correct answer in the absence of a 'non-functional' distractor led to relevant differences in reliability and difficulty (and to a lesser degree discrimination). The experts' ratings resulted in slightly greater changes compared to the statistical approach. Conclusions Based on item statistics and/or an expert panel's recommendation, the choice of a varying number of 3-4 (or partly 2) plausible distractors could be performed without marked deteriorations in psychometric characteristics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The German version of the Conners Adult ADHD Rating Scales (CAARS) has proven to show very high model fit in confirmative factor analyses with the established factors inattention/memory problems, hyperactivity/restlessness, impulsivity/emotional lability, and problems with self-concept in both large healthy control and ADHD patient samples. This study now presents data on the psychometric properties of the German CAARS-self-report (CAARS-S) and observer-report (CAARS-O) questionnaires.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Acetabular retroversion has been proposed to contribute to the development of osteoarthritis of the hip. For the diagnosis of this condition, conventional AP pelvic radiographs may represent a reliable, easily available diagnostic modality as they can be obtained with a reproducible technique allowing the anterior and posterior acetabular rims to be visible for assessment. This study was designed to: (i) determine cranial, central, and caudal anatomic acetabular version (AV) from cadaveric specimens; (ii) establish the validity and reliability of the radiographic measurements of central acetabular anteversion; and (iii) determine the validity and reliability of the radiographic "cross-over-sign" to detect acetabular retroversion. Using 43 desiccated pelvises (86 acetabuli) the anatomic AVs were measured at three different transverse planes (cranially, centrally, and caudally). From these pelvises, standardized AP pelvic radiographs were obtained. To directly measure central AV, a modified radiographic method is introduced for the use of AP pelvic radiographs. The validity and reliability of this radiographic method and of the radiographic cross-over-sign to detect cranial acetabular retroversion were determined. The mean central and caudal anatomic AVs were approximately 20 degrees , and the mean cranial AV was 8 degrees . Cranial retroversion (AV < 0 degrees ) was present in 19 of 86 hips (22%). A linear correlation was found between the central and cranial AV. Below 10 degrees of central AV, all acetabuli were cranially retroverted. Between 10 degrees and 20 degrees , 30% of the acetabuli were cranially retroverted, and above 20 degrees , only 1 of 45 acetabuli was cranially retroverted. The radiographic measurement of the central AV (20.3 +/- 6.5 degrees ) correlated strongly with the anatomic AV (20.1 +/- 6.4 degrees ). The sensitivity of the cross-over-sign to detect a cranial acetabular anteversion of less than 4 degrees was 96%, its specificity 95%, and the positive predictive and negative predictive values 90% and 98%, respectively. Both the modified radiographic anteversion measurements and the cross-over-sign demonstrated substantial inter- and intraobserver reliability. Retroversion is almost exclusively a problem of the cranial acetabulum. The cranial AV is on average 12 degrees lower than the central AV, with the latter directly measurable from AP pelvic radiographs. A central AV of less than 10 degrees was associated with cranial retroversion. The presence of a positive cross-over-sign is a highly reliable indicator of cranial AV of <4 degrees.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dental identification is the most valuable method to identify human remains in single cases with major postmortem alterations as well as in mass casualties because of its practicability and demanding reliability. Computed tomography (CT) has been investigated as a supportive tool for forensic identification and has proven to be valuable. It can also scan the dentition of a deceased within minutes. In the present study, we investigated currently used restorative materials using ultra-high-resolution dual-source CT and the extended CT scale for the purpose of a color-encoded, in scale, and artifact-free visualization in 3D volume rendering. In 122 human molars, 220 cavities with 2-, 3-, 4- and 5-mm diameter were prepared. With presently used filling materials (different composites, temporary filling materials, ceramic, and liner), these cavities were restored in six teeth for each material and cavity size (exception amalgam n = 1). The teeth were CT scanned and images reconstructed using an extended CT scale. Filling materials were analyzed in terms of resulting Hounsfield units (HU) and filling size representation within the images. Varying restorative materials showed distinctively differing radiopacities allowing for CT-data-based discrimination. Particularly, ceramic and composite fillings could be differentiated. The HU values were used to generate an updated volume-rendering preset for postmortem extended CT scale data of the dentition to easily visualize the position of restorations, the shape (in scale), and the material used which is color encoded in 3D. The results provide the scientific background for the application of 3D volume rendering to visualize the human dentition for forensic identification purposes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: High intercoder reliability (ICR) is required in qualitative content analysis for assuring quality when more than one coder is involved in data analysis. The literature is short of standardized procedures for ICR procedures in qualitative content analysis. OBJECTIVE: To illustrate how ICR assessment can be used to improve codings in qualitative content analysis. METHODS: Key steps of the procedure are presented, drawing on data from a qualitative study on patients' perspectives on low back pain. RESULTS: First, a coding scheme was developed using a comprehensive inductive and deductive approach. Second, 10 transcripts were coded independently by two researchers, and ICR was calculated. A resulting kappa value of .67 can be regarded as satisfactory to solid. Moreover, varying agreement rates helped to identify problems in the coding scheme. Low agreement rates, for instance, indicated that respective codes were defined too broadly and would need clarification. In a third step, the results of the analysis were used to improve the coding scheme, leading to consistent and high-quality results. DISCUSSION: The quantitative approach of ICR assessment is a viable instrument for quality assurance in qualitative content analysis. Kappa values and close inspection of agreement rates help to estimate and increase quality of codings. This approach facilitates good practice in coding and enhances credibility of analysis, especially when large samples are interviewed, different coders are involved, and quantitative results are presented.