33 resultados para Haptic guidance

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

60.00% 60.00%

Publicador:

Resumo:

We have developed a haptic-based approach for retraining of interjoint coordination following stroke called time-independent functional training (TIFT) and implemented this mode in the ARMin III robotic exoskeleton. The ARMin III robot was developed by Drs. Robert Riener and Tobias Nef at the Swiss Federal Institute of Technology Zurich (Eidgenossische Technische Hochschule Zurich, or ETH Zurich), in Zurich, Switzerland. In the TIFT mode, the robot maintains arm movements within the proper kinematic trajectory via haptic walls at each joint. These arm movements focus training of interjoint coordination with highly intuitive real-time feedback of performance; arm movements advance within the trajectory only if their movement coordination is correct. In initial testing, 37 nondisabled subjects received a single session of learning of a complex pattern. Subjects were randomized to TIFT or visual demonstration or moved along with the robot as it moved though the pattern (time-dependent [TD] training). We examined visual demonstration to separate the effects of action observation on motor learning from the effects of the two haptic guidance methods. During these training trials, TIFT subjects reduced error and interaction forces between the robot and arm, while TD subject performance did not change. All groups showed significant learning of the trajectory during unassisted recall trials, but we observed no difference in learning between groups, possibly because this learning task is dominated by vision. Further testing in stroke populations is warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

to report acute and late toxicity in prostate cancer patients treated by high-dose intensity-modulated radiation therapy (IMRT) with daily image-guidance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Little is known about the learning of the skills needed to perform ultrasound- or nerve stimulator-guided peripheral nerve blocks. The aim of this study was to compare the learning curves of residents trained in ultrasound guidance versus residents trained in nerve stimulation for axillary brachial plexus block. Ten residents with no previous experience with using ultrasound received ultrasound training and another ten residents with no previous experience with using nerve stimulation received nerve stimulation training. The novices' learning curves were generated by retrospective data analysis out of our electronic anaesthesia database. Individual success rates were pooled, and the institutional learning curve was calculated using a bootstrapping technique in combination with a Monte Carlo simulation procedure. The skills required to perform successful ultrasound-guided axillary brachial plexus block can be learnt faster and lead to a higher final success rate compared to nerve stimulator-guided axillary brachial plexus block.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The role of low-level stimulus-driven control in the guidance of overt visual attention has been difficult to establish because low- and high-level visual content are spatially correlated within natural visual stimuli. Here we show that impairment of parietal cortical areas, either permanently by a lesion or reversibly by repetitive transcranial magnetic stimulation (rTMS), leads to fixation of locations with higher values of low-level features as compared to control subjects or in a no-rTMS condition. Moreover, this unmasking of stimulus-driven control crucially depends on the intrahemispheric balance between top-down and bottom-up cortical areas. This result suggests that although in normal behavior high-level features might exert a strong influence, low-level features do contribute to guide visual selection during the exploration of complex natural stimuli.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper is meant to provide guidance to anyone wishing to write a neurological guideline for diagnosis or treatment, and is directed at the Scientist Panels and task forces of the European Federation of Neurological Societies (EFNS). It substitutes the previous guidance paper from 2004. It contains several new aspects: the guidance is now based on a change of the grading system for evidence and for the resulting recommendations, and has adopted The Grading of Recommendations, Assessment, Development and Evaluation system (GRADE). The process of grading the quality of evidence and strength of recommendations can now be improved and made more transparent. The task forces embarking on the development of a guideline must now make clearer and more transparent choices about outcomes considered most relevant when searching the literature and evaluating their findings. Thus, the outcomes chosen will be more critical, more patient-oriented and easier to translate into simple recommendations. This paper also provides updated practical recommendations for planning a guideline task force within the framework of the EFNS. Finally, this paper hopes to find the approval also by the relevant bodies of our future organization, the European Academy of Neurology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the feasibility and effectiveness of IVUS-guided puncture for gaining controlled target lumen reentry in subintimal recanalization of chronic iliac/femoral artery occlusions and in fenestration of aortic dissections. MATERIALS AND METHODS: Between 5/2004 and 12/2005 12 consecutive patients (7 male, 5 female; mean age 64.6 +/- 12.0 years) with chronic critical limb ischemia and ischemic complications of aortic dissection were treated using the Pioneer catheter. This 6.2-F dual-lumen catheter combines a 20-MHz IVUS transducer with a pre-shaped extendable, hollow 24-gauge nitinol needle. This coaxial needle allows real-time IVUS-guided puncture of the target lumen and after successful reentry a 0.014" guidewire may be advanced through the needle into the target lumen. 7 patients were treated for aortic dissection and 5 patients (with failed previous attempts at subintimal recanalization) for chronic arterial occlusion. Patients with aortic dissection (5 type A dissections, 2 type B dissections) had developed renal ischemia (n = 2), renal and mesenteric ischemia (n = 2), or low extremity ischemia (n = 3). Patients with chronic arterial occlusions (2 common iliac artery occlusions, 3 superficial femoral artery occlusions) experienced ischemic rest pain (n = 4), and a non-healing foot ulcer (n = 1). RESULTS: The technical success rate using the Pioneer catheter was 100%. The recanalization/fenestration time was 37 +/- 12 min. Procedure-related complications did not occur. In 10 cases a significant improvement of clinical symptoms was evident. One patient with aortic dissection and ischemic paraplegia required subsequent surgical intervention. One patient had persistent ischemic rest pain despite successful recanalization of a superficial femoral artery occlusion. CONCLUSION: The Pioneer catheter is a reliable device which may be helpful for achieving target lumen reentry in subintimal recanalization of chronic occlusions and in fenestration of aortic dissections.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Currently, in forensic medicine cross-sectional imaging gains recognition and a wide use as a non-invasive examination approach. Today, computed tomography (CT) or magnetic resonance imaging that are available for patients are unable to provide tissue information on the cellular level in a non-invasive manner and also diatom detection, DNA, bacteriological, chemical toxicological and other specific tissue analyses are impossible using radiology. We hypothesised that post-mortem minimally invasive tissue sampling using needle biopsies under CT guidance might significantly enhance the potential of virtual autopsy. The purpose of this study was to test the use of a clinically approved biopsy needle for minimally invasive post-mortem sampling of tissue specimens under CT guidance. MATERIAL AND METHODS: ACN III biopsy core needles 14 gauge x 160 mm with automatic pistol device were used on three bodies dedicated to research from the local anatomical institute. Tissue probes from the brain, heart, lung, liver, spleen, kidney and muscle tissue were obtained under CT fluoroscopy. RESULTS: CT fluoroscopy enabled accurate placement of the needle within the organs and tissues. The needles allowed for sampling of tissue probes with a mean width of 1.7 mm (range 1.2-2 mm) and the maximal length of 20 mm at all locations. The obtained tissue specimens were of sufficient size and adequate quality for histological analysis. CONCLUSION: Our results indicate that, similar to the clinical experience but in many more organs, the tissue specimens obtained using the clinically approved biopsy needle are of a sufficient size and adequate quality for a histological examination. We suggest that post-mortem biopsy using the ACN III needle under CT guidance may become a reliable method for targeted sampling of tissue probes of the body.