6 resultados para Handgrip dynamometry

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The optimal testing position for hand grip strength, which is a useful functional measure of nutritional status, is open to debate. We therefore examined the systematic difference between different postures in order to establish a methodology that is clinically relevant, easy to perform and reproducible.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To investigate whether body sodium content and blood volume contribute to the pathogenesis of orthostatic hypotension in patients with diabetes mellitus. SUBJECTS AND METHODS: Exchangeable sodium, plasma and blood volumes, and catecholamine, renin, and aldosterone levels were assessed in 10 patients with Type II diabetes mellitus who had orthostatic hypotension and control groups of 40 diabetic patients without orthostatic hypotension and 40 normal subjects of similar age and sex. In subgroups, clinical tests of autonomic function and cardiovascular reactivity to norepinephrine and angiotensin II infusions were performed. RESULTS: In diabetic patients with orthostatic hypotension, mean (+/- SD) supine blood pressure was 165/98 +/- 27/12 mm Hg (P <0.05 compared with other groups) and mean upright blood pressure was 90/60 +/- 38/18 mm Hg. Compared with controls, diabetic patients with orthostatic hypotension had a 10% lower blood volume. They also had less exchangeable sodium than patients with diabetes who did not have orthostatic hypotension (P <0.01). Compared with both groups of controls, diabetic patients with orthostatic hypotension had decreased 24-hour urinary norepinephrine excretion and a reduced diastolic blood pressure response to handgrip (P <0.05). Moreover, they displayed reduced products of exchangeable sodium or blood volume and sympathetic function indexes. Cardiovascular pressor reactivity to norepinephrine was enhanced (P <0.01) and beat-to-beat variation decreased (P <0.01) in both groups of diabetic patients. Microvascular complications were more prevalent in the diabetic patients with orthostatic hypotension (90% vs 35%). CONCLUSIONS: Patients who have Type II diabetes mellitus and orthostatic hypotension are hypovolemic and have sympathoadrenal insufficiency; both factors contribute to the pathogenesis of orthostatic hypotension.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Both anthropometric and functional measurements have been used in nutritional assessment and monitoring. Hand dynamometry is a predictor of surgical outcome and peak expiratory flow rate has been used as an index of respiratory muscle function. This study aims to measure in normal subjects the relationship between anthropometric measurements, voluntary muscle strength by hand grip dynamometry and respiratory muscle function by peak expiratory flow rate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The clinical demand for a device to monitor Blood Pressure (BP) in ambulatory scenarios with minimal use of inflation cuffs is increasing. Based on the so-called Pulse Wave Velocity (PWV) principle, this paper introduces and evaluates a novel concept of BP monitor that can be fully integrated within a chest sensor. After a preliminary calibration, the sensor provides non-occlusive beat-by-beat estimations of Mean Arterial Pressure (MAP) by measuring the Pulse Transit Time (PTT) of arterial pressure pulses travelling from the ascending aorta towards the subcutaneous vasculature of the chest. In a cohort of 15 healthy male subjects, a total of 462 simultaneous readings consisting of reference MAP and chest PTT were acquired. Each subject was recorded at three different days: D, D+3 and D+14. Overall, the implemented protocol induced MAP values to range from 80 ± 6 mmHg in baseline, to 107 ± 9 mmHg during isometric handgrip maneuvers. Agreement between reference and chest-sensor MAP values was tested by using intraclass correlation coefficient (ICC = 0.78) and Bland-Altman analysis (mean error = 0.7 mmHg, standard deviation = 5.1 mmHg). The cumulative percentage of MAP values provided by the chest sensor falling within a range of ±5 mmHg compared to reference MAP readings was of 70%, within ±10 mmHg was of 91%, and within ±15mmHg was of 98%. These results point at the fact that the chest sensor complies with the British Hypertension Society (BHS) requirements of Grade A BP monitors, when applied to MAP readings. Grade A performance was maintained even two weeks after having performed the initial subject-dependent calibration. In conclusion, this paper introduces a sensor and a calibration strategy to perform MAP measurements at the chest. The encouraging performance of the presented technique paves the way towards an ambulatory-compliant, continuous and non-occlusive BP monitoring system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS Skeletal muscle wasting affects 20% of patients with chronic heart failure and has serious implications for their activities of daily living. Assessment of muscle wasting is technically challenging. C-terminal agrin-fragment (CAF), a breakdown product of the synaptically located protein agrin, has shown early promise as biomarker of muscle wasting. We sought to investigate the diagnostic properties of CAF in muscle wasting among patients with heart failure. METHODS AND RESULTS We assessed serum CAF levels in 196 patients who participated in the Studies Investigating Co-morbidities Aggravating Heart Failure (SICA-HF). Muscle wasting was identified using dual-energy X-ray absorptiometry (DEXA) in 38 patients (19.4%). Patients with muscle wasting demonstrated higher CAF values than those without (125.1 ± 59.5 pmol/L vs. 103.8 ± 42.9 pmol/L, P = 0.01). Using receiver operating characteristics (ROC), we calculated the optimal CAF value to identify patients with muscle wasting as >87.5 pmol/L, which had a sensitivity of 78.9% and a specificity of 43.7%. The area under the ROC curve was 0.63 (95% confidence interval 0.56-0.70). Using simple regression, we found that serum CAF was associated with handgrip (R = - 0.17, P = 0.03) and quadriceps strength (R = - 0.31, P < 0.0001), peak oxygen consumption (R = - 0.5, P < 0.0001), 6-min walk distance (R = - 0.32, P < 0.0001), and gait speed (R = - 0.2, P = 0.001), as well as with parameters of kidney and liver function, iron metabolism and storage. CONCLUSION CAF shows good sensitivity for the detection of skeletal muscle wasting in patients with heart failure. Its assessment may be useful to identify patients who should undergo additional testing, such as detailed body composition analysis. As no other biomarker is currently available, further investigation is warranted.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Protein-energy-malnutrition (PEM) is common in people with end stage kidney disease (ESKD) undergoing maintenance haemodialysis (MHD) and correlates strongly with mortality. To this day, there is no gold standard for detecting PEM in patients on MHD. Aim of Study The aim of this study was to evaluate if Nutritional Risk Screening 2002 (NRS-2002), handgrip strength measurement, mid-upper arm muscle area (MUAMA), triceps skin fold measurement (TSF), serum albumin, normalised protein catabolic rate (nPCR), Kt/V and eKt/V, dry body weight, body mass index (BMI), age and time since start on MHD are relevant for assessing PEM in patients on MHD. Methods The predictive value of the selected parameters on mortality and mortality or weight loss of more than 5% was assessed. Quantitative data analysis of the 12 parameters in the same patients on MHD in autumn 2009 (n = 64) and spring 2011 (n = 40) with paired statistical analysis and multivariate logistic regression analysis was performed. Results Paired data analysis showed significant reduction of dry body weight, BMI and nPCR. Kt/Vtot did not change, eKt/v and hand grip strength measurements were significantly higher in spring 2011. No changes were detected in TSF, serum albumin, NRS-2002 and MUAMA. Serum albumin was shown to be the only predictor of death and of the combined endpoint “death or weight loss of more than 5%”. Conclusion We now screen patients biannually for serum albumin, nPCR, Kt/V, handgrip measurement of the shunt-free arm, dry body weight, age and time since initiation of MHD.