71 resultados para Hand-held cameras
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
BACKGROUND Cold atmospheric plasma (CAP, i.e. ionized air) is an innovating promising tool in reducing bacteria. OBJECTIVE We conducted the first clinical trial with the novel PlasmaDerm(®) VU-2010 device to assess safety and, as secondary endpoints, efficacy and applicability of 45 s/cm(2) cold atmospheric plasma as add-on therapy against chronic venous leg ulcers. METHODS From April 2011 to April 2012, 14 patients were randomized to receive standardized modern wound care (n = 7) or plasma in addition to standard care (n = 7) 3× per week for 8 weeks. The ulcer size was determined weekly (Visitrak(®) , photodocumentation). Bacterial load (bacterial swabs, contact agar plates) and pain during and between treatments (visual analogue scales) were assessed. Patients and doctors rated the applicability of plasma (questionnaires). RESULTS The plasma treatment was safe with 2 SAEs and 77 AEs approximately equally distributed among both groups (P = 0.77 and P = 1.0, Fisher's exact test). Two AEs probably related to plasma. Plasma treatment resulted in a significant reduction in lesional bacterial load (P = 0.04, Wilcoxon signed-rank test). A more than 50% ulcer size reduction was noted in 5/7 and 4/7 patients in the standard and plasma groups, respectively, and a greater size reduction occurred in the plasma group (plasma -5.3 cm(2) , standard: -3.4 cm(2) ) (non-significant, P = 0.42, log-rank test). The only ulcer that closed after 7 weeks received plasma. Patients in the plasma group quoted less pain compared to the control group. The plasma applicability was not rated inferior to standard wound care (P = 0.94, Wilcoxon-Mann-Whitney test). Physicians would recommend (P = 0.06, Wilcoxon-Mann-Whitney test) or repeat (P = 0.08, Wilcoxon-Mann-Whitney test) plasma treatment by trend. CONCLUSION Cold atmospheric plasma displays favourable antibacterial effects. We demonstrated that plasma treatment with the PlasmaDerm(®) VU-2010 device is safe and effective in patients with chronic venous leg ulcers. Thus, larger controlled trials and the development of devices with larger application surfaces are warranted.
Resumo:
We propose a method to acquire 3D light fields using a hand-held camera, and describe several computational photography applications facilitated by our approach. As our input we take an image sequence from a camera translating along an approximately linear path with limited camera rotations. Users can acquire such data easily in a few seconds by moving a hand-held camera. We include a novel approach to resample the input into regularly sampled 3D light fields by aligning them in the spatio-temporal domain, and a technique for high-quality disparity estimation from light fields. We show applications including digital refocusing and synthetic aperture blur, foreground removal, selective colorization, and others.
Resumo:
BACKGROUND/AIMS: Rebound tonometry (RT) is performed without anaesthesia with a hand held device. The primary aim was to compare RT with Goldmann applanation tonometry (GAT) and to correlate with central corneal thickness (CCT). The secondary aim was to prove tolerability and practicability of RT under "study conditions" and "routine practice conditions." METHODS: In group 1 (52 eyes/28 patients), all measurements were taken by the same physician, in the same room and order: non-contact optical pachymetry, RT, slit lamp inspection, GAT. Patients were questioned about discomfort or pain. In group 2 (49 eyes/27 patients), tonometry was performed by three other physicians during routine examinations. RESULTS: RT was well tolerated and safe. Intraocular pressure (IOP) ranged between 6 mm Hg and 48 mm Hg. No different trends were found between the groups. RT tended to give slightly higher readings: n = 101, mean difference 1.0 (SD 2.17) mm Hg; 84.1% of RT readings within plus or minus 3 mm Hg of GAT; 95% confidence interval in the Bland-Altman analysis -3.2 mm Hg to +5.2 mm Hg. Both RT and GAT showed a weak positive correlation with CCT (r2 0.028 and 0.025, respectively). CONCLUSIONS: RT can be considered a reliable alternative for clinical screening and in cases where positioning of the head at the slit lamp is impossible or topical preparations are to be avoided.
Resumo:
When a hand-held object is moved, grip and load force are accurately coordinated for establishing grasp stability. In the present work, the question was raised whether patients with Gilles de la Tourette syndrome (TS), who show tic-like movements, are impaired in grip-load force control when executing a manipulative task. To this end, we assessed force regulation during action patterns that required rhythmical unimanual or bimanual (iso-directional/anti-directional) movements. Results showed that the profile of grip-load force ratio was characterized by maxima and minima that were realized at upward and downward hand positions, respectively. TS patients showed increased force ratios during unimanual and bimanual movements, compared with control subjects, indicative of an inaccurate specification of the precision grip. Functional imaging data complemented the behavioural results and revealed that secondary motor areas showed no (or greatly reduced) activation in TS patients when executing the movement tasks as compared with baseline conditions. This indicates that the metabolic level in the secondary motor areas was equal during rest and task performance. At the neuronal level, this observation suggests that these cortical areas were continuously involved in movement preparation. Based on these data, we conclude that the ongoing activation of secondary motor areas may be explained by the TS patients' involuntary urges to move. Accordingly, interference will prevent an accurate planning of voluntary behaviour. Together, these findings reveal modulations in movement organization in patients with TS and exemplify degrading consequences for manual function.
Resumo:
The paper showcases the field- and lab-documentation system developed for Kinneret Regional Project, an international archaeological expedition to the Northwestern shore of the Sea of Galilee (Israel) under the auspices of the University of Bern, the University of Helsinki, Leiden University and Wofford College. The core of the data management system is a fully relational, server-based database framework, which also includes time-based and static GIS services, stratigraphic analysis tools and fully indexed document/digital image archives. Data collection in the field is based on mobile, hand-held devices equipped with a custom-tailored stand-alone application. Comprehensive three-dimensional documentation of all finds and findings is achieved by means of total stations and/or high-precision GPS devices. All archaeological information retrieved in the field – including tachymetric data – is synched with the core system on the fly and thus immediately available for further processing in the field lab (within the local network) or for post-excavation analysis at remote institutions (via the WWW). Besides a short demonstration of the main functionalities, the paper also presents some of the key technologies used and illustrates usability aspects of the system’s individual components.
Resumo:
This thesis covers a broad part of the field of computational photography, including video stabilization and image warping techniques, introductions to light field photography and the conversion of monocular images and videos into stereoscopic 3D content. We present a user assisted technique for stereoscopic 3D conversion from 2D images. Our approach exploits the geometric structure of perspective images including vanishing points. We allow a user to indicate lines, planes, and vanishing points in the input image, and directly employ these as guides of an image warp that produces a stereo image pair. Our method is most suitable for scenes with large scale structures such as buildings and is able to skip the step of constructing a depth map. Further, we propose a method to acquire 3D light fields using a hand-held camera, and describe several computational photography applications facilitated by our approach. As the input we take an image sequence from a camera translating along an approximately linear path with limited camera rotations. Users can acquire such data easily in a few seconds by moving a hand-held camera. We convert the input into a regularly sampled 3D light field by resampling and aligning them in the spatio-temporal domain. We also present a novel technique for high-quality disparity estimation from light fields. Finally, we show applications including digital refocusing and synthetic aperture blur, foreground removal, selective colorization, and others.
Resumo:
Computed ultrasound tomography in echo-mode (CUTE) allows imaging the speed of sound inside tissue using hand-held pulse-echo ultrasound. This technique is based on measuring the changing local phase of beamformed echoes when changing the transmit beam steering angle. Phantom results have shown a spatial resolution and contrast that could qualify CUTE as a promising novel diagnostic modality in combination with B-mode ultrasound. Unfortunately, the large intensity range of several tens of dB that is encountered in clinical images poses difficulties to echo phase tracking and results in severe artefacts. In this paper we propose a modification to the original technique by which more robust echo tracking can be achieved, and we demonstrate in phantom experiments that dynamic range artefacts are largely eliminated. Dynamic range artefact reduction also allowed for the first time a clinical implementation of CUTE with sufficient contrast to reproducibly distinguish the different speed of sound in different tissue layers of the abdominal wall and the neck.
Resumo:
Root canal treatment is a frequently performed dental procedure and is carried out on teeth in which irreversible pulpitis has led to necrosis of the dental pulp. Removal of the necrotic tissue remnants and cleaning and shaping of the root canal are important phases of root canal treatment. Treatment options include the use of hand and rotary instruments and methods using ultrasonic or sonic equipment. OBJECTIVES: The objectives of this systematic review of randomized controlled trials were to determine the relative clinical effectiveness of hand instrumentation versus ultrasonic instrumentation alone or in conjunction with hand instrumentation for orthograde root canal treatment of permanent teeth. MATERIAL AND METHODS: The search strategy retrieved 226 references from the Cochrane Oral Health Group Trials Register (7), the Cochrane Central Register of Controlled Trials (CENTRAL) (12), MEDLINE (192), EMBASE (8) and LILACS (7). No language restriction was applied. The last electronic search was conducted on December 13th, 2007. Screening of eligible studies was conducted in duplicate and independently. RESULTS: Results were to be expressed as fixed-effect or random-effects models using mean differences for continuous outcomes and risk ratios for dichotomous outcomes with 95% confidence intervals. Heterogeneity was to be investigated including both clinical and methodological factors. No eligible randomized controlled trials were identified. CONCLUSIONS: This review illustrates the current lack of published or ongoing randomized controlled trials and the unavailability of high-level evidence based on clinically relevant outcomes referring to the effectiveness of ultrasonic instrumentation used alone or as an adjunct to hand instrumentation for orthograde root canal treatment. In the absence of reliable research-based evidence, clinicians should base their decisions on clinical experience, individual circumstances and in conjunction with patients' preferences where appropriate. Future randomized controlled trials might focus more closely on evaluating the effectiveness of combinations of these interventions with an emphasis on not only clinically relevant, but also patient-centered outcomes.
Resumo:
Purpose: In a prospective study, we assessed if a diagnosis of osteoporosis and periodontitis could predict hip and hand fractures in older persons. Materials and methods: Bone density was assessed by a Densitometer. Periodontitis was defined by evidence of alveolar bone loss. Results: 788 Caucasians (52.4% women, overall mean age: 76 years, S.D. +/- 9.0, range: 62 to 96) were enrolled and 7.4% had a hip/hand fracture in 3 years. Calcaneus PIXI T-values < - 1.6 identified osteoporosis in 28.2% of the older persons predicting a hip/hand fracture with an odds ratio of 3.3:1 (95% CI: 1.9, 5.7, p < 0.001). Older persons with osteoporosis had more severe periodontitis (p < 0.01). Periodontitis defined by >= 30% of sites with >= 5 mm distance between the cemento-enamel junction (CEJ) and bone level (ABL) was found in 18.7% of the older persons predicting a hip/hand fracture with an odds ratio of 1.8:1 (95% CI: 1.0, 3.3, p < 0.05). Adjusted for age, the odds ratio of a hip/hand fracture in older persons with osteoporosis (PIXI T-value <-2.5) and periodontitis was 12.2:1 (95% CI: 3.5, 42.3, p < 0.001). Conclusions: Older persons with osteoporosis and periodontitis have an increased risk for hip/hand fractures