50 resultados para HYBRID ELECTRIC VEHICLE IN LOW SCALE (HELVIS) MINI-HEV

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper we present results on measurements of the dielectric strength of liquid argon near its boiling point and cathode-anode distances in the range of 0.1 mm to 40 mm with spherical cathode and plane anode. We show that at such distances the applied electric field at which breakdowns occur is as low as 40 kV/cm. Flash-overs across the ribbed dielectric of the high voltage feed-through are observed for a length of 300 mm starting from a voltage of 55 kV. These results contribute to set reference for the breakdown-free design of ionization detectors, such as Liquid Argon Time Projection Chambers (LAr TPC).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Small animal models are widely used in basic research. However, experimental systems requiring extracorporeal circuits are frequently confronted with limitations related to equipment size. This is particularly true for oxygenators in systems with limited volumes. Thus we aimed to develop and validate an ultra mini-oxygenator for low-volume, buffer-perfused systems. Methods: We have manufactured a series of ultra mini-oxygenators with approximately 175 aligned, microporous, polypropylene hollow fibers contained inside a shell, which is sealed at each of the two extremities to isolate perfusate and gas compartments. With this construction, gas passes through hollow fibers, while perfusate circulates around fibers. Performance of ultra mini-oxygenators (oxygen partial pressure (PO2 ), gas and perfusate flow, perfusate pressure and temperature drop) were assessed with modified Krebs-Henseleit buffer in an in vitro perfusion circuit and an ex vivo rat heart preparation. Results: Mean priming volume of ultra mini-oxygenators was 1.2±0.5 mL and, on average, 86±6% of fibers were open (n=17). In vitro, effective oxygenation (PO2=400-500 mmHg) was achieved for all flow rates up to 50 mL/min and remained stable for at least 2 hours (n=5). Oxygenation was also effective and stable (PO2=456±40 mmHg) in the isolated heart preparation for at least 60 minutes ("venous" PO2=151±11 mmHg; n=5). Conclusions: We have established a reproducible procedure for fabrication of ultra mini-oxygenators, which provide reliable and stable oxygenation for at least 60-120 min. These oxygenators are especially attractive for pre-clinical protocols using small, rather than large, animals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a study on the dependence of electric breakdown discharge properties on electrode geometry and the breakdown field in liquid argon near its boiling point. The measurements were performed with a spherical cathode and a planar anode at distances ranging from 0.1 mm to 10.0 mm. A detailed study of the time evolution of the breakdown volt-ampere characteristics was performed for the first time. It revealed a slow streamer development phase in the discharge. The results of a spectroscopic study of the visible light emission of the breakdowns complement the measurements. The light emission from the initial phase of the discharge is attributed to electro-luminescence of liquid argon following a current of drifting electrons. These results contribute to set benchmarks for breakdown-safe design of ionization detectors, such as Liquid Argon Time Projection Chambers (LAr TPC).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new generation of high definition computed tomography (HDCT) 64-slice devices complemented by a new iterative image reconstruction algorithm-adaptive statistical iterative reconstruction, offer substantially higher resolution compared to standard definition CT (SDCT) scanners. As high resolution confers higher noise we have compared image quality and radiation dose of coronary computed tomography angiography (CCTA) from HDCT versus SDCT. Consecutive patients (n = 93) underwent HDCT, and were compared to 93 patients who had previously undergone CCTA with SDCT matched for heart rate (HR), HR variability and body mass index (BMI). Tube voltage and current were adapted to the patient's BMI, using identical protocols in both groups. The image quality of all CCTA scans was evaluated by two independent readers in all coronary segments using a 4-point scale (1, excellent image quality; 2, blurring of the vessel wall; 3, image with artefacts but evaluative; 4, non-evaluative). Effective radiation dose was calculated from DLP multiplied by a conversion factor (0.014 mSv/mGy × cm). The mean image quality score from HDCT versus SDCT was comparable (2.02 ± 0.68 vs. 2.00 ± 0.76). Mean effective radiation dose did not significantly differ between HDCT (1.7 ± 0.6 mSv, range 1.0-3.7 mSv) and SDCT (1.9 ± 0.8 mSv, range 0.8-5.5 mSv; P = n.s.). HDCT scanners allow low-dose 64-slice CCTA scanning with higher resolution than SDCT but maintained image quality and equally low radiation dose. Whether this will translate into higher accuracy of HDCT for CAD detection remains to be evaluated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Viral load and CD4% are often not available in resource-limited settings for monitoring children's responses to antiretroviral therapy (ART). We aimed to construct normative curves for weight gain at 6, 12, 18, and 24 months following initiation of ART in children, and to assess the association between poor weight gain and subsequent responses to ART. DESIGN Analysis of data from HIV-infected children younger than 10 years old from African and Asian clinics participating in the International epidemiologic Databases to Evaluate AIDS. METHODS The generalized additive model for location, scale, and shape was used to construct normative percentile curves for weight gain at 6, 12, 18, and 24 months following ART initiation. Cox proportional models were used to assess the association between lower percentiles (< 50th) of weight gain distribution at the different time points and subsequent death, virological suppression, and virological failure. RESULTS Among 7173 children from five regions of the world, 45% were underweight at baseline. Weight gain below the 50th percentile at 6, 12, 18, and 24 months of ART was associated with increased risk of death, independent of baseline characteristics. Poor weight gain was not associated with increased hazards of virological suppression or virological failure. CONCLUSION Monitoring weight gain on ART using age-specific and sex-specific normative curves specifically developed for HIV-infected children on ART is a simple, rapid, sustainable tool that can aid in the identification of children who are at increased risk of death in the first year of ART.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Experiments searching for weak interacting massive particles with noble gases such as liquid argon require very low detection thresholds for nuclear recoils. A determination of the scintillation efficiency is crucial to quantify the response of the detector at low energy. We report the results obtained with a small liquid argon cell using a monoenergetic neutron beam produced by a deuterium-deuterium fusion source. The light yield relative to electrons was measured for six argon recoil energies between 11 and 120 keV at zero electric drift field.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIM: To assess the prevalence of mild cognitive impairment (MCI) in medical inpatients aged 55-85 years without known cognitive deficits, and how often ward physicians mentioned MCI in their discharge notes. Moreover, we aimed to identify variables associated with MCI and to assess the sensitivity and specificity of the Mini-Mental State Examination (MMSE) for MCI. METHODS: Two neuropsychologists administered a 60-min battery of validated tests to evaluate different cognitive domains. The diagnosis of MCI was based on a prespecified algorithm. The sensitivity and specificity of the MMSE for MCI were calculated. RESULTS: Fifteen patients showed a normal cognitive profile (21.4%), while 55 patients (78.6%) showed MCI. Ward physicians, blinded to the results of the neuropsychological evaluation, did not mention MCI in their discharge notes of any of the evaluated patients. The only variable independently associated with MCI was the MMSE. A MMSE score of < or =28 showed a sensitivity of 85.5% and a specificity of 66.7% for MCI. CONCLUSION: MCI is frequent albeit overlooked in elderly medical inpatients without previously known cognitive deficits. In view of therapies preventing the progression of MCI to dementia, MCI screening will be crucial. The MMSE represents a promising screening tool for MCI in medical inpatients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is some controversy around the value of sentinel lymph node excision (SLNE). Especially SLNE of cutaneous head and neck malignancies has been debated intensively, in part because of the complexity of the lymphatic drainage in this region associated with potential high morbidity. In order to improve preoperative three-dimensional mapping of sentinel lymph nodes (SLN), in the head and neck region, by means of hybrid single photon emission computed tomography/computed tomography (SPECT/CT) is gaining significance. Our study seeks to identify the potential medical and economic advantages of preoperative SPECT/CT in direct comparison to standard SLNE without SPECT/CT in patients with cutaneous head and neck malignancies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The progress in molecular genetics in animal breeding is moderately effective as compared to traditional animal breeding using quantitative genetic approaches. There is an extensive disparity between the number of reported quantitative trait loci (QTLs) and their linked genetic variations in cattle, pig, and chicken. The identification of causative mutations affecting quantitative traits is still very challenging and hampered by the cloudy relationship between genotype and phenotype. There are relatively few reports in which a successful identification of a causative mutation for an animal production trait was demonstrated. The examples that have attracted considerable attention from the animal breeding community are briefly summarized and presented in a table. In this mini-review, the recent progress in mapping quantitative trait nucleotides (QTNs) are reviewed, including the ABCG2 gene mutation that underlies a QTL for fat and protein content and the ovine MSTN gene mutation that causes muscular hypertrophy in Texel sheep. It is concluded that the progress in molecular genetics might facilitate the elucidation of the genetic architecture of QTLs, so that also the high-hanging fruits can be harvested in order to contribute to efficient and sustainable animal production.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We examined the incidence of and risk factors for tuberculosis during the first year of highly active antiretroviral therapy in low-income (4540 patients) and high-income (22,217 patients) countries. Although incidence was much higher in low-income countries, the reduction in the incidence of tuberculosis associated with highly active antiretroviral therapy was similar: the rate ratio for months 7-12 versus months 1-3 was 0.48 (95% confidence interval, 0.36-0.64) in low-income countries and 0.36 (95% confidence interval, 0.26-0.50) in high-income countries. A low CD4 cell count at the start of therapy was the most important risk factor in both settings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To assess the frequency of and risk factors for discordant responses at 6 months on highly active antiretroviral therapy (HAART) in previously treatment-naive HIV patients from resource-limited countries. METHODS: The Antiretroviral Therapy in Low-Income Countries Collaboration is a network of clinics providing care and treatment to HIV-infected patients in Africa, Latin America, and Asia. Patients who initiated therapy between 1996 and 2004, were aged 16 years or older, and had a baseline CD4 cell count were included in this analysis. Responses were defined based on plasma viral load (PVL) and CD4 cell count at 6 months as complete virologic and immunologic (VR(+)IR(+)), virologic only (VR(+)IR(-)), immunologic only (VR(-)IR(+)), and nonresponse (VR(-)IR(-)). Multinomial logistic regression was used to assess the association between therapy responses and clinical and demographic variables. RESULTS: Of the 3111 patients eligible for analysis, 1914 had available information at 6 months of therapy: 1074 (56.1%) were VR(+)IR(+), 364 (19.0%) were VR(+)IR(-), 283 (14.8%) were (VR(-)IR(+)), and 193 (10.1%) were VR(-)IR(-). OF THE 3111 patients eligible for analysis, 1914 had available information at 6 months of therapy: 1074 (56.1%) were VRIR, 364 (19.0%) were VRIR, 283 (14.8%) were (VRIR), and 193 (10.1%) were VRIR. Compared with complete responders, virologic-only responders were older, had a higher baseline CD4 cell count, had a lower baseline PVL, and were more likely to have received a nonstandard HAART regimen; immunologic-only responders were younger, had a lower baseline CD4 cell count, had a higher baseline PVL, and were more likely to have received a protease inhibitor-based regimen. CONCLUSIONS: The frequency of and risk factors for discordant responses were comparable to those observed in developed countries. Longer follow-up is needed to assess the long-term impact of discordant responses on mortality in these resource-limited settings.